486 resultados para espectrometria de absorção atômica com fonte contínua e de alta resolução


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical method for the isolation based on matrix solid-phase dispersion technique and gas chromatographic determination of pesticides in cattle plasma is presented. It was fortified 0.25 g of plasma with pesticides and blended with 1 g each C18 and Na2SO4. The homogenized matter was transferred to a SPE cartridge, which contained 1 g of activated florisil with 5 mL acetonitrile. The analites were eluted under vaccum with 15 mL acetonitrile, the extract was analyzed by gas chromatography-mass spectrometry. The limit of quantification of the method was 0.04 mg L-1 for chlorphenvinfos and fipronil and 0.02 mg L-1 for cypermethrin..

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiovascular diseases are responsible for the largest number of deaths among humans worldwide, including heart attacks, strokes, and thrombosis. The treatment of thrombosis is generally through the administration of anticoagulant and/or antiplatelet drugs, which have some clinical limitations. Plants synthesize a wide variety of bioactive metabolites in response to different stimuli. This review focuses on a number of molecules of vegetal origin belonging to different chemical classes, with significant anticoagulant and antiplatelet effects. Their promising antithrombotic profile confirms the potential of natural products as a source of lead molecules for drug development in the prevention and treatment of thrombosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The synthesis and characterization of crosslinked chitosan microbeads and their application in the removal of Cr(VI) are described. New kinetic and thermodynamic parameters of Cr(VI) adsorptions processes were found using continuous isothermal calorimetry. All adsorption processes are exothermic in nature. However, a multivariate statistical analysis have pointed out that adsorption enthalpies were affected by important binary interactions of the initial Cr(VI) in solution and temperature. The adsorption energetic data were well fitted to a kinetic exponential model, which have indicated fractionary adsorption kinetic orders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to evaluate the chemical elements levels in soil, submitted to different management systems and use by the Energy Dispersive X-Ray Fluorescence Spectrometry - EDXRF. The systems were T1 - agro forestry (SAF), T2 - Native Field (CN), T3 - Native Forest (NM), T4 - Tillage Forest (PF); T5 - conventional tillage system (SPC) and T6 - System tillage (NT). Samples were collected at 0-10 and 10-20 cm, dried and ground for analysis in EDX-720. The soil showed no difference in the average concentrations of chemical elements analyzed in the profiles, but the systems presented different concentrations of metal elements, and T3 had the highest K, Ca and Zn at 0-10 cm and higher contents of K, Ca, Cu, Zn and Mn in the layer of 10-20 cm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microcystins are non-ribosomal peptides that must be detected for its health concern. Here, microcystin LR and its specific antibody were respectively tethered to the substrate and to the tip of an atomic force microscope, after surface functionalization using 3-aminopropyltriethoxysilane and glutaraldehyde. Functionalization was confirmed comparing topographic images taken on bare and modified tips. Force versus distance curves were successfully used to measure the specific antibody-antigen interactions comparing with a control in which microcystin was initially blocked by incubation with free antibodies. The results showed unequivocally the specific recognition of MLR, suggesting that this method could be useful for biosensor development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is here discussed the development of a low cost analytical instrument with capacity for metals determination using atomic emission measurements in an electrothermal atomization system with a tungsten coil atomizer. The main goal was to show a new frontier for using this atomizer and to demonstrate that the simple instrumental arrangement here proposed has potential for portability and for solving analytical tasks related to metals determination. Atomic emission of calcium was selected for the adjustment of instrumental parameters and to evaluate the main characteristics of the lab-built instrument. Cobalt was determined in medicines and one alloy to demonstrate its feasibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the organic compounds of cigar samples from different brands were analyzed. The compound extraction was made using the matrix solid-phase dispersion (MSPD) technique, followed by gas chromatography and identification by mass spectrometry (GC-MS) and standards, when available. Thirty eight organic compounds were found in seven different brands. Finally, with the objective of characterizing and discriminating the cigar samples, multivariate statistical analyses were applied to data, e.g.; principal component analysis (PCA) and hierarchical cluster analysis (HCA). With such analyses, it was possible to discriminate three main groups of three quality levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The processing of national petroleums causes many operational problems due to the asphaltene aggregation phenomena. To evaluate the behavior of these phenomena, a study based on optical scan technique was carried out to understand the behavior of pure oils and their mixtures. The evaluation according to criteria established by ASTM D7061-06¹ gives a result of asphaltene flocculation of according to the separability number. In this study, the aspects related to the existence of colloidal forms of peptized asphaltenes in distinct solvents present in petroleums can cause changes in the kinetics of asphaltene flocculation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method based on headspace - solid phase microextraction coupled with gas chromatography - mass spectrometry was validated for the quantitative determination of 18 organochlorine pesticides in water. For the extraction conditioning some parameters as the best type of coating fiber, time and temperature of extraction, pH and ionic strength were evaluated. The method HS-SPME/GC-MS/MS showed linear coefficient above 0.9948. The repeatability of the measurements were lower than 7.6%. Relative recoveries were between 88 and 110%. Limits of detection from 0.5 x 10-3 to 1.0 mg L-1 were obtained. A total of 31 samples were analyzed and 16 presented from 1 to 5 pesticides.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Systematic studies were undertaken in the intra zeolitic media to better understand the ability of zeolite type LTA in occluded nitrogen used in fertilizer and soil conditioning. We have measured the dry matter production from the cultivation of corn in a greenhouse for about 40 days, and also the amounts of nitrogen absorbed, retained and lost by leaching. The dry matter production in the cultivation with different concentrations of nitrogen occluded in the zeolite, was more efficient than the traditional fertilizer, which demonstrated better use of nitrogen to reduce leaching losses, which implies a possible reduction of costs for nitrogen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of pesticide residues in water samples by Liquid Chromatography require sample preparation for extraction and enrichment of the analytes with the minimization of interferences to achieve adequate detection limits. The Solid Phase Extraction (SPE), Solid Phase Microextraction (SPME), Stir Bar Sorptive Extraction (SBSE) and Dispersive Liquid-Liquid Microextraction (DLLME) techniques have been widely used for extraction of pesticides in water. In this review, the principles of these sample preparation techniques associated with the analysis by Liquid Chromatography with Diode Array Detection (LC-DAD) or Mass Spectrometry (LC-MS) are described and an overview of several applications were presented and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In commemoration of the International Year of Chemistry this article presents the normalization and standardization of key terms used in mass spectrometry in Portuguese Language.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An absolute method is described via mass spectrometry (MS) for the structural assignment of isomers within the class of methylpiperidines. The method explores both the unimolecular and bimolecular gas phase behavior of structurally diagnostic fragment ions (SDFI). For the methylpiperidnes, the isomeric 2-methyl, 3-methyl and 4-methyl 2-azabutadienyl cations are found to function as SDFI. These fragment ions are expected to be formed from all members within the class, to be stable and to retain the structural information of the precursor molecule, and to not interconvert into one another. To characterize these SDFI, both the collision induced dissociation (CID) in argon and bimolecular ion/molecule chemistry with ethyl vinyl ether were compared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes an analytical method for analyzing polychlorinated biphenyls in corn samples using solid phase extraction (SPE) followed by determination by GC-MS. All calibration curves proved linear (r> 0.99). Recoveries ranged between 74.1 and 110.6% with relative standard deviation lower than 20% for all compounds. The limits of quantitation for the method were between 0.025 and 0.1 ng g-1. Of the 51 samples analyzed, PCB 180 showed the highest frequency, being detected in more than 39%, followed by PCB 138, detected in more than 33% of samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of multivariate analysis to spectrophotometric (UV) data was explored for distinguishing extracts of cachaça woods commonly used in the manufacture of casks for aging cachaças (oak, cabreúva-parda, jatobá, amendoim and canela-sassafrás). Absorbances close to 280 nm were more strongly correlated with oak and jatobá woods, whereas absorbances near 230 nm were more correlated with canela-sassafrás and cabreúva-parda. A comparison between the spectrophotometric model and the model based on chromatographic (HPLC-DAD) data was carried out. The spectrophotometric model better explained the variance data (PC1 + PC2 = 91%) exhibiting potential as a routine method for checking aged spirits.