Extraction and clean-up are essential points in polycyclic aromatic hydrocarbon (PAHs) analysis in a solid matrix. This work compares extraction techniques and clean-up procedures for PAH analysis. PAH levels, their toxicological significance and source were also evaluated in the waters of the Cocó and Ceará rivers. The efficiency of PAH recovery was higher for the soxhlet and ultrasonic techniques. PAH recovery varied from 69.3 to 99.3%. Total PAH concentration (ΣHPA) varied from 720.73 to 2234.76 µg kg-1 (Cocó river) and 96.4 to 1859.21 µg kg-1 (Ceará river). The main PAH sources are pyrolytic processes and the levels were classified as medium so that adverse effects are possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work optimized the HPLC conditions for the simultaneous determination of luteolin, apigenin, myricetin, quercetin and kaempferol in aglycone form, as well defined the best conditions for hydrolysis/extraction of these flavonoids in fruits, using the statistical central composite design and response surface analysis. A reverse phase method was developed using a gradient of methanol/water acidified with 0.3% formic acid as mobile phase and a photodiode array detector. The samples were extracted with methanol/water (50:50 v/v) at 90 ºC. The optimum time and HCl concentration varied for the different fruits investigated, demonstrating the necessity of optimizing these conditions for each fruit analyzed. Good recovery (87.1 to 96.3%), repeatability and linearity were obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of square-wave voltammetry in conjunction with a cathodically pre-treated diamond electrode for the analytical determination of sodium cyclamate is described. The samples were analyzed as received in a 0.5 mol L-1 H2SO4 solution in the concentration range from 5.0 × 10-5 mol L-1 to 4.1 × 10-4 mol L-1, with a detection limit of 4.8 × 10-6 mol L-1. The RSD was smaller than 1.2 % and the proposed method was applied with success in the determination of sodium cyclamate in several dietary products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A chromatographic method was developed for cholesterol determination in feed for ruminants using response surface methodology. Among the five approaches of sample preparation methods tested, the saponification of the sample without heating presented less interference in the gas chromatography. The method presented a relative standard deviation (RSD) of 4.3%, recoveries between 84 and 87% and detection limit of 0.001 mg of cholesterol per g of feed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

2,4,6-trinitrotoluene (TNT) is an energetic material that shows scarce crystalline properties that can be improved by addition of 2,2',4,4',6,6'-hexanitrostilbene (HNS) in the crystallization process. HNS is a very important high explosive used in a variety of military, aerospace and industrial formulations owing to its suitable properties. It is an insensitive and thermal stable explosive that can be produced from 2,4,6-trinitrotoluene (TNT). The purpose of this work is the quantitative determination of HNS and TNT in explosives by thermogravimetric analysis (TG) and Fourier transform infrared spectroscopy (FT-IR).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polymeric materials are widely used in the chemical industry and are part of our daily lives. Inorganic species may be added to them as additives, anti-oxidizing agents, stabilizers, plasticizers, colorants and catalysts and may be present in a wide range of concentrations. Their determination demands the development of analytical methods considering different kinds of polymeric materials, their composition and the final use of the material. Although many different analytical techniques may be used, this review emphasizes those based on atomic absorption and emission spectrometry. Solid sampling techniques and digestion methods are described and discussed and compared considering published results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative analysis of colored substances is generally performed using a spectrophotometer for detection of radiation. However, the combination of digital images and mathematical conversion of colors is an alternative for quantitative procedures based on colored chemical reactions. This work proposes a didactic experiment using a scanner for determination of ascorbic acid in medicines based on the formation of the Prussian blue complex. Results were in good agreement with a conventional spectrophotometer method and the procedure is attractive for instrumental analysis undergraduate courses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work purposes the development of an analytical method for amitriptyline determination in pharmaceutical formulations using FIA system. It was based on interaction of amitriplyline with sodium lauryl sulphate in acid medium (pH 2.5) resulting in the ion-pair formation turbidimetrically detected at 410 nm. The fitting regression equation for range curve from 2.0 x 10-3 up to 3.2 x 10-3 mol L-1 was found to be analytical signal = -2.7417 + 0.1538 [amitriptyline] (r = 0.99991) with a detection limit of 1.8 x 10-3 mol L-1. The precision assessed as relative standard deviation (n = 10) was found to be 2.40 and 1.94%, for the respective concentration of amitriplyline 2.0 x 10-3 and 3.2 x 10-3 mol L-1 and the sample throughout was 60 h-1. The accuracy of method was successfully assessed in pharmaceutical formulation after comparison with a reference analytical method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A UV spectrophotometric method was developed and validated and a chromatographic method was adapted from the American Pharmacopeia for the analysis of Fluoxetine Hydrochloride capsules. Ethanol was used as solvent for the spectrophotometric method, with detection and determination at 276 nm. The separation for the chromatographic method was carried out using the reversed-phase column LC-8, triethylamine buffer, stabilizer free tetrahydrofuran and methanol (5:3.5:1.5), pH 6.0 as mobile phase and detection at 227 nm. The results obtained for both methods showed to be accurate, precise, robust and linear over the concentration range 100.00 - 300.00 µg/mL and 40.00 - 80.00 µg/mL of fluoxetine hydrochloride for the spectrophotometric and chromatographic methods, respectively. The accuracy of the methods was evaluated by a recovery test and showed results between 98.89 and 101.10%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A HPLC method was developed to quantify thymine and thymidine impurities in stavudine bulk drug. The separation was carried out in isocratic mode using methanol/water (20:80) as mobile phase, a C18 column and UV detection at 266 nm. The method provided selectivity based on peak purities and resolution among peaks. It was linear over the range of 0.5-5.0 µg/mL. The quantitation limits were 0.021 µg/mL for thymine and 0.134 µg/mL for thymidine. The average accuracies of three concentrations ranged from 97.06 to 102.61% and precision was close to 1%. The method showed robustness, remaining unaffected by deliberate variations in relevant parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work was developed a method for the determination of saccharin in dietary products by a biamperometric titration, using two silver electrodes as working electrodes and silver nitrate as titrant. It were used products as juices (light) and sweeteners with saccharin in concentrations ranged from 8.73 x 10-5 mol L-1 to 1.0 x 10-2 mol L-1, and the results were in close agreement with those data found using a HPLC method at a confidence level of 95%. The main advantages of the proposed method are its simplicity, rapid and low cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, specific and sensitive GC-MS procedure with ion m/z 62 was validated for the determination of ethyl carbamate (EC) in spirits. It exhibited linearity over the concentration of 30 to 600 μg/L with 30 μg/L limit of quantification. EC was detected in 70 of the 71 samples analyzed with levels from 33 to 2609 μg/L (mean level = 893 μg/L). 35% of the samples contained 500 to 1000 μg/L and 23% contained 150 to 500 and 1000 to 1500 μg/L. No significant correlation was found between EC and the levels of copper, pH and alcohol content of the samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple liquid chromatographic method for the simultaneous determination of creatinine, hippuric acid, mandelic acid, phenylglyoxylic acid and o, m and p-methylhippuric acids was developed and validated. Sample preparation was only dilution with water (1:10), followed by centrifugation. Analysis was performed in a reversed phase column (Lichrospher RP 8ec), 250 x 4.0 mm, with isocratic elution with phosphate buffer pH 2.3 and acetonitrile (90:10, v/v). The method presents adequate linearity, precision and accuracy and allows the simultaneous determination of the biomarkers of exposure to toluene, xylene and styrene together with creatinine, reducing cost and laboratory time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work, a method was developed and validated for the quantification of benzyl isothiocyanate (BITC) in the fruits of Carica papaya. The quantification of this compound was carried out by gas chromatography (GC) with selective detectors - nitrogen phosphorus detector (NPD) and flame photometric detector (FPD). The performance of these detectors showed a higher sensitivity of the NPD with a broader linear range of detection. The LOD/LOQ were 0.038/0.100 µg/mL for NPD and 5.78/19.29 µg/mL for FPD. The recovery of the method for BITC was 90,64%. An average value of BITC concentration in all the analyzed samples was 16,23 µg BITC/g.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser-induced fluorescence spectroscopy was used to determine the humification degree of the organic matter of a whole soil, that is, soil without any physical or chemical treatment. Particle size was determined in physically separated fractions. The humification of organic matter, the depth of the soil and the planting system can be correlated. On the surface of the soil, no tillage provided the smallest humification in comparison with the conventional tillage and reduced tillage. The fractions of the superficial layer of the soil (0-20 cm) indicated larger humification in the fraction from 20 to 53 µm and the smallest in the fraction of <2 µm.