Exchangeable Al has been used as a criterion for the calculation of lime requirement in several Brazilian States. However, the laboratory method with extraction by a 1 mol L-1 KCl solution followed by indirect alkaline titration is not accurate for some Brazilian soils, mainly in the case of soils with high organic matter content. The objective of this study was therefore to evaluate the stoichiometry of H+/Al3+ in KCl soil extracts. The results suggested that organically complexed Al is the main contributor to exchangeable acidity in soils enriched with organic matter. Liming recommendations for organic soils based exclusively on exchangeable Al determined by the NaOH titration method should therefore be revised.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tobacco farmers of southern Brazil use high levels of fertilizers, without considering soil and environmental attributes, posing great risk to water resources degradation. The objective of this study was to monitor nitrate and ammonium concentrations in the soil solution of an Entisol in and below the root zone of tobacco under conventional tillage (CT), minimum tillage (MT) and no-tillage (NT). The study was conducted in the small-watershed Arroio Lino, in Agudo, State of Rio Grande do Sul, Brazil. A base fertilization of 850 kg ha-1 of 10-18-24 and topdressing of 400 kg ha-1 of 14-0-14 NPK fertilizer were applied. The soil solution was sampled during the crop cycle with a tension lysimeter equipped with a porous ceramic cup. Ammonium and nitrate concentrations were analyzed by the distillation and titration method. Nitrate concentrations, ranging from 8 to 226 mg L-1, were highest after initial fertilization and decreased during the crop cycle. The average nitrate (N-NO3-) concentration in the root zone was 75 in NT, 95 in MT, and 49 mg L-1 in CT. Below the root zone, the average nitrate concentration was 58 under NT, 108 under MT and 36 mg L-1 under CT. The nitrate and ammonium concentrations did not differ significantly in the management systems. However, the nitrate concentrations measured represent a contamination risk to groundwater of the watershed. The ammonium concentration (N-NH4+) decreased over time in all management systems, possibly as a result of the nitrification process and root uptake of part of the ammonium by the growing plants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The rate of carbon dioxide production is commonly used as a measure of microbial activity in the soil. The traditional method of CO2 determination involves trapping CO2 in an alkali solution and then determining CO2 concentration indirectly by titration of the remaining alkali in the solution. This method is still commonly employed in laboratories throughout the world due to its relative simplicity and the fact that it does not require expensive, specific equipment. However, there are several drawbacks: the method is time-consuming, requires large amounts of chemicals and the consistency of results depends on the operator's skills. With this in mind, an improved method was developed to analyze CO2 captured in alkali traps, which is cheap and relatively simple, with a substantially shorter sample handling time and reproducibility equivalent to the traditional titration method. A comparison of the concentration values determined by gas phase flow injection analysis (GPFIA) and titration showed no significant difference (p > 0.05), but GPFIA has the advantage that only a tenth of the sample volume of the titration method is required. The GPFIA system does not require the purchase of new, costly equipment but the device was constructed from items commonly found in laboratories, with suggestions for alternative configurations for other detection units. Furthermore, GPFIA for CO2 analysis can be equally applied to samples obtained from either the headspace of microcosms or from a sampling chamber that allows CO2 to be released from alkali trapping solutions. The optimised GPFIA method was applied to analyse CO2 released from degrading hydrocarbons from a site contaminated by diesel spillage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Acid Mine Drainage (AMD) is one of the main environmental impacts caused by mining. Thus, innovative mitigation strategies should be exploited, to neutralize acidity and prevent mobilization of trace elements in AMD. The use of industrial byproducts has been considered an economically and environmentally effective alternative to remediate acid mine drainage. Therefore, the objective of this study was to evaluate the use of steel slag to mitigate acid mine drainage in a sulfidic material from a uranium mine, as an alternative to the use of limestone. Thus, increasing doses of two neutralizing agents were applied to a sulfidic material from the uranium mine Osamu Utsumi in Caldas, Minas Gerais State. A steel slag from the company ArcelorMittal Tubarão and a commercial limestone were used as neutralizing agents. The experiment was conducted in leaching columns, arranged in a completely randomized, [(2 x 3) + 1] factorial design, consisting of two neutralizing agents, three doses and one control, in three replications, totaling 21 experimental units. Electrical conductivity (EC), pH and the concentrations of Al, As, Ca, Cd, Cu, Fe, Mn, Ni, S, Se, and Zn were evaluated in the leached solutions. The trace element concentration was evaluated by ICP-OES. Furthermore, the CO2 emission was measured at the top of the leaching columns by capturing in NaOH solution and titration with HCl, in the presence of BaCl2. An increase in the pH of the leachate was observed for both neutralizing agents, with slightly higher values for steel slag. The EC was lower at the higher lime dose at an early stage of the experiment, and CO2 emission was greater with the use of limestone compared to steel slag. A decrease in trace element mobilization in the presence of both neutralizing agents was also observed. Therefore, the results showed that the use of steel slag is a suitable alternative to mitigate AMD, with the advantage of reducing CO2 emissions to the atmosphere compared to limestone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The variety of soils in the State of Acre is wide and their chemical profiles are still not fully understood. The nature of the material of origin of these soils is indicated by the high aluminium (Al) content, commonly associated with high calcium (Ca) and magnesium (Mg) contents. The study objective was to use different methods to quantify Al in soils from toposequences formed from material of a sedimentary nature originating from the Solimões Formation, in Acre, Brazil. Trenches were opened at three distinct points in the landscape: shoulder, backslope and footslope positions. Soil samples were collected for physical, chemical, mineralogical analyses. The Al content was quantified using different methods. High Al contents were found in most of these horizons, associated with high Ca and Mg levels, representing the predominant cations in the sum of exchangeable bases. The mineralogy indicates that the soils are still in a low weathering phase, with the presence of significant quantities of 2:1 minerals. Similar Al contents were determined by the methods of NaOH titration, xylenol orange spectrometry and inductively coupled plasma optical emission spectrometry. However, no consistent data were obtained by the pyrocatechol violet method. Extraction with KCl overestimated the exchangeable Al content due to its ability to extract the non-exchangeable Al present in the smectite interlayers. It was observed that high Al contents are related to the instability of the hydroxyl-Al smectite interlayers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ABSTRACT Humic acids (HA) are a component of humic substances (HS), which are found in nearly all soils, sediments, and waters. They play a key role in many, if not most, chemical and physical properties in their environment. Despite the importance of HA, their high complexity makes them a poorly understood system. Therefore, understanding the physicochemical properties and interactions of HA is crucial for determining their fundamental role and obtaining structural details. Cationic surfactants are known to interact electrostatically and hydrophobically with HA. Because they are a very well-known and characterized system, they offer a good choice as molecular probes for studying HA. The objective of this study was to evaluate the interaction between cationic surfactants and HA through isothermal titration calorimetry in a thermodynamic manner, aiming to obtain information about the basic structure of HA, the nature of this interaction, and if HA from different origins show different basic structures. Contrary to what the supramolecular model asserts, HA structure is not loosely held, though it may separate depending on the conditions the HA are subjected to in their milieu. It did not show any division or conformational change when interacting with surfactants. The basic structure of the HA remains virtually the same regardless of the different sources and compositions of these HA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes an experiment to be performed in both instrumental analysis and experimental physical-chemistry curricular disciplines in order to open options to develop challenging basic research activities. Thus the experimental procedures and the results obtained in the preparation of electrodeposited lead dioxide onto graphite and its evaluation as potentiometric sensor for H3O+ and Pb2+ ions, are presented. The data obtained in acid-base titrations were compared with those of the traditional combination glass electrode at the same conditions. Although a linear sub-Nernstian response to free hydrogen ions was observed for the electrodeposited PbO2 electrode, a good agreement was obtained between them. Working as lead(II) sensing electrode, the PbO2 showed a linear sub-Nernstian behavior at total Pb2+ concentrations ranging from 3,5 x 10-4 to 3,0 x 10-2 mol/L in nitrate media. For the redox couple PbO2/Pb(II) the operational slope converges to the theoretical one, as the acidity of the working solution increases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The classical volumetric titration of Fe2+ with MnO4-, used in some routine analysis as well as in undergraduate courses was improved. SnCl2 (to reduce Fe3+ to Fe2+) and HgCl2 (to oxidize excess SnCl2) were substituted by metallic zinc in boiling solutions, thus avoiding the toxic HgCl2 and Hg2Cl2; nitrate ions do not interfere in the improved methodology (it is an interference in the classical one) and the reproducibility of the determinations is increased by using metallic zinc. Determinations by students of undergraduate courses are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new automated system for acid-base flow titrations is proposed. In the operation mode, several sample to titrant volumetric ratios are injected in an air segmented plug. Five three way solenoid valves and three acrilic junctions, assembled in a hidrodynamic injection system, were accountable for the monosegmented reagents plug formation. A turbulent flow reactor was used for a perfect mix of reagents in the plug. The detector system employed a glass combined electrode fitted in an acrilic holder. Titrations of hydrochloric, nitric and acetic acids, in several concentrations, were performed with standard sodium hidroxide, for evaluation of the efficiency of the system. The relative standard deviation of the determinations was about ±0,5% and each titration was carried out in 3-4 minutes. A Quick BASIC 4.5® program was developed for the titrator control.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

'Cachaça' is the Brazilian name for the spirit obtained from sugarcane. According to Brazilian regulations, it may be sold raw or with addition of sugar and may contain up to 5 mg/L of copper. Copper in "cachaça" was determined by titration with EDTA, using a homemade copper membrane electrode for end-point detection. It was found a pooled standard deviation of 0,057 mg/L and there was no significant difference between the results obtained by the potentiometric method and by flame atomic absorption spectrometry with standard addition. Among the 21 'cachaça' samples from 16 different brands analyzed, three overpassed the legal copper limit. For its characteristics of accuracy, precision, and speed, the potentiometric method may be employed advantageously in routine analysis, specially when low cost is a major concern.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Acid base properties of mixed species of the microalgae Spirulina were studied by potentiometric titration in medium of 0.01 and 0.10 mols L-1 NaNO3 at 25.0±0.10 C using modified Gran functions or nonlinear regression techniques for data fitting. The discrete site distribution model was used, permitting the characterization of five classes of ionizable sites in both ionic media. This fact suggests that the chemical heterogeneity of the ionizable sites on the cell surface plays a major role on the acid-base properties of the suspension in comparison to electrostatic effects due to charge-charge interactions. The total of ionizable sites were 1.75±0.10 and 1.86±0.20 mmolsg-1 in ionic media of 0.01 and 0.10 mols L-1 NaNO3, respectively. A major contribution of carboxylic groups was observed with an average 34 and 22% of ionizable sites being titrated with conditional pcKa of 4.0 and 5.4, respectively. The remaining 44% of ionizable sites were divided in three classes with averaged conditional pcKa of 6.9, 8.7 and 10.12, which may be assigned respectively to imidazolic, aminic, and phenolic functionalities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The acidity determinations method of humic acids (HA) content was developed by Schnitzer and Gupta and is a very well known procedure. Nevertheless, care is necessary to prevent measure errors due to non-controlled BaCO3 production, during the filtration and titration of HA total acidity. To overcome this problem, we developed in our laboratory a simple filtration and titration system for the determination of HA acidity under inert atmosphere. This system enables a better reproducibility and accuracy of total, carboxylic and phenolic acidity measures than those by Schnitzer and Gupta method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to show an experiment from which students can learn some of the main characteristics of buffer solutions. A mixture of some acid-base indicators, named as Yamada's indicator, can be used to estimate pH values in an acid-base titration of a buffer, with good approximation. In the experiment it is also possible to verify the relationship between the buffer capacity and the concentrations and the molar ratio of the components of a NH3 / NH4+ buffer solution. The shortage of experiments associated with the relative small importance given to many aspects of buffer solutions, is now explored with simplicity. In the proposed experiments, students prepare buffer solutions by themselves, calculate the pH, understand how acid-base indicators act and learn how buffer solutions work through graph constructed by sharing experimental data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The precise nature of the reaction between chromium chloride and potassium niobate at specific pH levels 12.0, 10.8 and 7.6 has been studied by means of electrometric techniques involving pH and conductometric titrations. The well defined breaks and inflections in the titration curves provide cogent evidence for the formation and precipitation of chromium ortho-Cr2O3.3Nb2 O5, hexa-4Cr2O3.9Nb2 O5 and meta-Cr2O3.3Nb2 O5 niobates in the vicinity of pH 7.5, 6.8 and 5.6, respectively. Analytical investigations of the precipitates have also been carried out which substantiate the results of the electrometric study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The data analyzed in this work were generated following the methodology developed by Molina et al.(J. Electroanal. Chem., 1979) for the calibration of a potentiometric system of measurement of hydrogen-ion concentrations resulting from neutralizations, at 25 ºC, of acidic or alkaline solutions at constant ionic strength (0.1 mol.l-1) held with NaClO4. The observed data present a serious deviation in relation to the mathematical model derived from the Nernst equation, for pH values ranging from 3 to 11, where pH=-log[H+]. We show that the minimization of the sum of the absolute values of the residuals gives estimates that are not influenced by outlying values.