63 resultados para supplied air


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The air included in droplets generated by spray nozzles directly int0erferes in transport, deposition and retention of the droplets after its impact on the target. The objective of this study was to analyze the interference of adjuvants in the amount of air included in droplets generated by spray nozzles. The treatments were composed by four spray solutions containing mineral oil, vegetable oil, surfactant and water, and three spray nozzles, two air induction type and one pre-orifice. The air included was calculated by the difference between the volume of spray mix (air plus liquid) and only the liquid, which was made by means of sprayed samples captured in a funnel and collected in a graduated cylinder. The surface tension was estimated by the gravimetric method using a precision scale and a graduated pipette. The surfactant provided the largest percentage of air included in the spray. For the surface tension, the mineral oil and the surfactant had the lowest values. It was concluded that the use of adjuvants had a direct influence on the percentage of air included. In addition, products with greater ability to reduce surface tension and to form homogeneous solutions provided the increase in the percentage of air included in the droplet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The air-assisted ground spray is fairly widespread. However, due to the unpredictable weather conditions, the operational efficiency is impaired by stops on grounds of low humidity and high temperatures. The aim of this work was to assess an air humidification method and evaluate its impact on temperature and air humidity for the air curtain of the air-assisted sprayer. With respect to relative air humidity, it has increased in 6.59%, being the maximum change when inserting 1.92 L min-1. So, it is concluded that the pipeline humidification might significantly reduce temperature and enhance air humidity. The treatments performed in this study consisted of a varied flow of a humidity device, related to weather conditions. Temperature and relative air humidity were measured at 1.0 m height from right to left of middle point of the machine, corresponding to the end of the spray boom, in the middle and end of right spray boom. The readings were also performed at three different distances from the end of the pipeline and at 0.25 and 0.50 m from that to the soil. The results show that 0.48 L min-1 in the humidification system has promoted a better efficiency in reducing air-temperature, on average 2.52 ºC when compared to the non-humidified one.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT A portable flow board system was developed in the present study with the aim to facilitate lab-scale experiments of controlled atmosphere (CA) with fruits and vegetables. This sturdy flow board combines ease fabrication, low cost and gas economy. Its functionality is provided by manifolds and gas mixers. Each gaseous component is supplied by a gas cylinder through a differential valve of adjusted pressure control, generally at 6 kPa, and forced through 13 standardized restrictors coupled to each manifold output. Controlled atmospheres are then formed with one, two or three gases in 13 gas mixers affixed to the flow board base, which are further conducted through flexible tubes to storage mini-chambers that can also be used to study metabolic consumption and production of gaseous components. The restrictors used in the flow gaseous components were manufactured from microhematocrit test-type capillary glass tubes following the hot forming method under continuous air flow. The portable flow board showed to be low cost and simple post-harvest equipment that allows preparing controlled atmospheres in open systems with stable composition and flow, in a manner similar to traditional flow boards with control of gas escape by barostats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considering acute and chronic toxicity effects on human and animal health caused by pesticide residues in food, this study aimed to analyze organophosphorate (OP) and carbamate (CB) in feedstuff and water destined for dairy cattle, as well as in the milk produced by these animals, through gas chromatography (GC). In the Agreste region of Pernambuco, Brazil, 30 raw milk samples and all components of the animals' diet were collected from several farms. Out of the 30 milk of milk analyzed, six (20%) were contaminated with OP, five (16.7%) with CB, and one sample with both pesticides. From 48 analyzed feed samples, 15 (31.25%) were contaminated with residues of OP, six (12.50%) with CB, and one sample was contaminated with both pesticides. Out of 16 water samples analyzed, six (37.50%) were contaminated with OP residues, but non with CB. In four dairy farms the pesticides detected in milk were compatible with the active principles found in water and/or foodstuff, suggesting them to be the source of contamination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental investigation is performed in a turbulent flow in a seven wire-wrapped rod bundle, mounted in an open air facility. Static pressure distributions are measured on central and peripheral rods. By using a Preston tube, the wall shear stress profiles are experimentally obtained along the perimeter of the rods. The geometric parameters of the test section are P/D=1.20 and H/D=15. The measuring section is located at L/D=40 from the air inlet. It is observed that the dimensionless static pressure and wall shear stress profiles are nearly independent of the Reynolds number and strongly dependent of the wire-spacer position, with abrupt variations of the parameters in the neighborhood of the wires.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Atlantic Forest on the slopes of Serra do Mar around Cubatão (São Paulo, Brazil) has been affected by massive emissions of pollutants from the local growing industrial complex. The effects of air pollution on the amounts of leaf nitrogen, total soluble phenols and total tannins of Tibouchina pulchra Cogn., a common species in the area of Cubatão, were investigated, as well as the possible influence of the altered parameters on the leaf area damaged by herbivores. Fully expanded leaves were collected at two sites: the valley of Pilões river (VP), characterized by a vegetation virtually not affected by air pollution and taken as a reference; and valley of Mogi river (VM), close to the core region of the industrial complex, and severely affected by air pollution. No differences were observed for any parameters between samples collected in the summer and winter in both sites. On the other hand, compared to VP, individuals growing in VM presented higher amounts of nitrogen and lower amounts of total soluble phenols and total tannins, as well as higher percentages of galls per leaf and higher leaf area lost to herbivores. Regression analysis revealed that the increase in leaf area lost to herbivores can be explained by the increase of the content of nitrogen and decrease in the contents of total soluble phenols and total tannins. Although significant, the coefficients of explanation found were low for all analyses, suggesting that other biotic or abiotic factors are likely to influence leaf attack by herbivores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several aspects of nutrient cycling were studied at two sites of Atlantic Forest, in São Paulo State, Southeast Brazil (23o46’ S; 46o18’ W), which exhibited different degrees of forest structure decline caused by the air pollution emitted by the industrial complex of Cubatão, being referred here as the most and least affected sites (MAS and LAS, respectively). These investigations were developed during 1984 - 1986, a period in which the most severe negative effects of air pollution could be observed. Concentrations and amounts of N, P, K, Ca, Mg and S in four ecosystem compartments (leaves, litter layer, soil and roots) and in rainfall, throughfall and litterfall are briefly presented. At each site, the content of mineral elements generally decreased from leaves to litterfall and litter layer on the forest floor. Soil surface layer (0 - 5 cm) in both sites was the richest in mineral elements. Soil fertility was greater at LAS. In general, nutrient amounts remaining in the compartments and cycling through the ecosystem were greater at LAS as well, which could be due to the higher complexity of the forest structure at this site. Rainfall contributed more to soil inputs of K, Ca, Mg and S than litterfall at both sites. The nutrient residence times in the litter layer were higher and the index of nutrient use efficiency was lower at the most affected site. It was concluded that nutrient cycling was disturbed by air pollution at both sites, but to a greater extent at MAS. The main consequences of the air pollution stress were detected in the flux of nutrients through litterfall and in the litter layer on the forest floor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fruits were collected from trees of Coffea arabica cv. Obatã grown at Mococa and Adamantina in São Paulo State, Brazil, which are regions with marked differences in air temperature that produce coffee with distinct qualities. Mococa is a cooler location that produces high-quality coffee, whereas coffee from Adamantina is of lower quality. The amino acid and protein contents, amino acid profile, and proteinase activity and type in endosperm protein extracts were analysed. Proteinase genes were identified, and their expression was assayed. All results indicate that temperature plays a role in controlling proteinase activity in coffee endosperm. Proteinase activity was higher in the endosperm of immature fruits from Adamantina, which was correlated with higher amino acid content, changes in the amino acid profile, and increased gene expression. Cysteine proteinases were the main class of proteinases in the protein extracts. These data suggest that temperature plays an important role in coffee quality by altering nitrogen compound composition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increasing use of alcohol as an alternative fuel to gasoline or diesel can increase emission of formaldehyde, an organic gas that is irritant to the mucous membranes. The respiratory system is the major target of air pollutants and its major defense mechanism depends on the continuous activity of the cilia and the resulting constant transportation of mucous secretion. The present study was designed to evaluate the effects of formaldehyde on the ciliated epithelium through a relative large dose range around the threshold limit value adopted by the Brazilian legislation, namely 1.6 ppm (1.25 to 5 ppm). For this purpose, the isolated frog palate preparation was used as the target of toxic injury. Four groups of frog palates were exposed to diluted Ringer solution (control, N = 8) and formaldehyde diluted in Ringer solution at three different concentrations (1.25, 2.5 and 5.0 ppm, N = 10 for each group). Mucociliary clearance and ciliary beat frequency decreased significantly in contact with formaldehyde at the concentrations of 2.5 and 5.0 ppm after 60 min of exposure (P<0.05). We conclude that relatively low concentrations of formaldehyde, which is even below the Brazilian threshold limit value, are sufficient to cause short-term mucociliary impairment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to determine if exposure of cervical mucus to air during specular examination could modify mucus pH. Detection of changes is justified because of their possible interference with sperm-mucus interaction, since an acidic pH is unfavorable to sperm penetration and is associated with infertility due to the cervical factor. Twenty women with good quality mucus were evaluated. pH measurements of ecto- and endocervical mucus were made in situ using a glass electrode after 0-, 5- and 10-min exposure to air. There was a progressive alkalinization of mucus pH. Mean values of ectocervical mucus pH were 6.91, 7.16 and 7.27, while mean values of endocervical mucus pH were 7.09, 7.34 and 7.46 at 0, 5 and 10 min, respectively. Significant differences were found between the mean values obtained at 0 and 5 min, and at 0 and 10 min (P<0.05), whereas the differences in mean values at 5 and 10 min were not significant at either site. We conclude that 5 to 10 min of exposure to atmospheric air affects cervical mucus pH in a significant way. Since tests used to evaluate sperm-mucus interaction generally have not considered this possibility, we suggest that they should be performed immediately after mucus collection in order to avoid misinterpretation of the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The exposure of fish to air is normally expected to interfere with the nitrogen excretion process. Hoplias malabaricus and Hoplerythrinus unitaeniatus, two teleost species, display distinct behaviors in response to decreases in natural reservoir water levels, although they may employ similar biochemical strategies. To investigate this point, plasma levels of ammonia, urea, uric acid, and the two urea cycle enzymes, ornithine carbamoyl transferase (OCT) and arginase (ARG), as well as glutamine synthetase (GS) were determined for both species after exposure to air. Plasma ammonia increased gradually during exposure to air, but only H. malabaricus showed increased concentrations of urea. Plasma uric acid remained very low in both fish. Enzymatic activities (mean ± SD, µmol min-1 g protein-1) of H. malabaricus showed significant increases (P<0.05, N = 6) in OCT from 0.84 ± 0.05 to 1.42 ± 0.03, in ARG from 8.07 ± 0.47 to 9.97 ± 0.53 and in GS from 1.15 ± 0.03 to 2.39 ± 0.04. The OCT and ARG enzymes remained constant in H. unitaeniatus (N = 6), but GS increased from 1.49 ± 0.02 to 2.06 ± 0.03. Although these species are very closely related and share the same environment, their biochemical strategies in response to exposure to air or to increased plasma ammonia are different.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Air pollution has been associated with health effects on different age groups. The present study was designed to assess the impact of daily changes in air pollutants (NO2, SO2, CO, O3, and particle matter (PM10)) on total number of daily neonatal deaths (those that occur between the first and the 28th days of life) in São Paulo, from January 1998 to December 2000, since adverse outcomes such as neonatal deaths associated with air pollution in Brazil have not been evaluated before. Generalized additive Poisson regression models were used and nonparametric smooth functions (loess) were adopted to control long-term trend, temperature, humidity, and short-term trends. A linear term was used for holidays. The association between air pollutants and neonatal deaths showed a short time lag. Interquartile range increases in PM10 (23.3 µg/m³) and SO2 (9.2 µg/m³) were associated with increases of 4% (95% CI, 2-6) and 6% (95% CI, 4-8), respectively. Instead of adopting a two-pollutant model we created an index to represent PM10 and SO2 effects. For an interquartile range increase in the index an increase of 6.3% (95% CI, 6.1-6.5) in neonatal deaths was observed. These results agree with previous studies performed by our group showing the deleterious effects of air pollutants during the perinatal period. The method reported here represents an alternative approach to analyze the relationship between highly correlated pollutants and public health problems, reinforcing the idea of the synergic effects of air pollutants in public health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An increase in daily mortality from myocardial infarction has been observed in association with meteorological factors and air pollution in several cities in the world, mainly in the northern hemisphere. The objective of the present study was to analyze the independent effects of environmental variables on daily counts of death from myocardial infarction in a subtropical region in South America. We used the robust Poisson regression to investigate associations between weather (temperature, humidity and barometric pressure), air pollution (sulfur dioxide, carbon monoxide, and inhalable particulate), and the daily death counts attributed to myocardial infarction in the city of São Paulo in Brazil, where 12,007 fatal events were observed from 1996 to 1998. The model was adjusted in a linear fashion for relative humidity and day-of-week, while nonparametric smoothing factors were used for seasonal trend and temperature. We found a significant association of daily temperature with deaths due to myocardial infarction (P < 0.001), with the lowest mortality being observed at temperatures between 21.6 and 22.6ºC. Relative humidity appeared to exert a protective effect. Sulfur dioxide concentrations correlated linearly with myocardial infarction deaths, increasing the number of fatal events by 3.4% (relative risk of 1.03; 95% confidence interval = 1.02-1.05) for each 10 µg/m³ increase. In conclusion, this study provides evidence of important associations between daily temperature and air pollution and mortality from myocardial infarction in a subtropical region, even after a comprehensive control for confounding factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to assess the effect of air pollution on pediatric respiratory morbidity, we carried out a time series study using daily levels of PM10, SO2, NO2, ozone, and CO and daily numbers of pediatric respiratory emergency room visits and hospital admissions at the Children's Institute of the University of São Paulo Medical School, from August 1996 to August 1997. In this period there were 43,635 hospital emergency room visits, 4534 of which were due to lower respiratory tract disease. The total number of hospital admissions was 6785, 1021 of which were due to lower respiratory tract infectious and/or obstructive diseases. The three health end-points under investigation were the daily number of emergency room visits due to lower respiratory tract diseases, hospital admissions due to pneumonia, and hospital admissions due to asthma or bronchiolitis. Generalized additive Poisson regression models were fitted, controlling for smooth functions of time, temperature and humidity, and an indicator of weekdays. NO2 was positively associated with all outcomes. Interquartile range increases (65.04 µg/m³) in NO2 moving averages were associated with an 18.4% increase (95% confidence interval, 95% CI = 12.5-24.3) in emergency room visits due to lower respiratory tract diseases (4-day moving average), a 17.6% increase (95% CI = 3.3-32.7) in hospital admissions due to pneumonia or bronchopneumonia (3-day moving average), and a 31.4% increase (95% CI = 7.2-55.7) in hospital admissions due to asthma or bronchiolitis (2-day moving average). The study showed that air pollution considerably affects children's respiratory morbidity, deserving attention from the health authorities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to determine the impact of acute short-term exposure to air pollution on the cardiorespiratory performance of military fireman living and working in the city of Guarujá, São Paulo, Brazil. Twenty-five healthy non-smoking firemen aged 24 to 45 years had about 1 h of exposure to low and high levels of air pollution. The tests consisted of two phases: phase A, in Bertioga, a town with low levels of air pollution, and phase B, in Cubatão, a polluted town, with a 7-day interval between phases. The volunteers remained in the cities (Bertioga/Cubatão) only for the time required to perform the tests. Cumulative load 10 ± 2 min-long exertion tests were performed on a treadmill, consisting of a 2-min stage at a load of 7 km/h, followed by increasing exertion of 1 km h-1 min-1 until the maximum individual limit. There were statistically significant differences (P < 0.05) in anaerobic threshold (AT) between Cubatão (35.04 ± 4.91 mL kg-1 min-1) and Bertioga (36.98 ± 5.62 mL kg-1 min-1; P = 0.01), in the heart rate at AT (AT HR; Cubatão 152.08 ± 14.86 bpm, Bertioga 157.44 ± 13.64 bpm; P = 0.001), and in percent maximal oxygen consumption at AT (AT%VO2max; Cubatão 64.56 ± 6.55%, Bertioga 67.40 ± 5.35%; P = 0.03). However, there were no differences in VO2max, maximal heart rate or velocity at AT (ATvel) observed in firemen between towns. The acute exposure to pollutants in Cubatão, SP, caused a significant reduction in the performance at submaximal levels of physical exertion.