106 resultados para simultaneous graphite furnace atomic absorption spectrometry
Resumo:
A sorption concentration method using impregnated silica has been developed to determine small concentration of lead in water by Atomic Absorption Spectrometry.
Resumo:
The complex interaction between hepatitis C virus infection, iron homeostasis and the response to antiviral treatment remains controversial. The aim of this study was to evaluate the influence of hepatic iron concentration (HIC) on the sustained virological response (SVR) to antiviral therapy in patients with chronic hepatitis C. A total of 50 patients who underwent pretreatment liver biopsy with assessment of HIC by graphite furnace atomic absorption spectroscopy and were subsequently submitted to antiviral treatment with interferon/peginterferon and ribavirin were included in the study. Patients with alcoholism, history of multiple blood transfusion, chronic kidney disease, hemolytic anemia and parenteral iron therapy were excluded. The iron related markers and HIC were compared between those who achieved an SVR and non-responders (NR) patients. The mean age was 45.7 years and the proportion of patients' gender was not different between SVR and NR patients. The median serum iron was 138 and 134 µg/dL (p = 0.9), the median serum ferritin was 152.5 and 179.5 ng/mL (p = 0.87) and the median HIC was 9.9 and 8.2 µmol/g dry tissue (p = 0.51), for SVR and NR patients, respectively. Thus, hepatic iron concentration, determined by a reliable quantitative method, was not a negative predictive factor of SVR in patients with chronic hepatitis C presenting mild to moderate hepatic iron accumulation.
Resumo:
Thermospray flame furnace Atomic Absorption Spectrometry (TS-FF-AAS) was used for the total determination of Cd, Pb and Zn in fresh water and seawater samples at µg L-1 levels, and in marine sediment samples at µg g-1 levels. Using a sample loop of 50 µL and a peristaltic pump the samples were transported into the metallic tube placed over an air/acetylene flame, through a ceramic capillary (o.d. = 3.2 mm) containing two parallel internal orifices (i.d = 0.5 mm). The detection limits determined for Cd, Pb and Zn using a synthetic water matrix (2.5% m/v NaCl, 0.5% m/v MgCl2 and 0.8% m/v CaCl2) were 0.32 µg L-1; 2.6 µg L-1 and 0.21 µg L-1 respectively. The methodology by TS-FF-AAS was validated by determination of Cd, Pb and Zn in certified reference materials of water and marine sediment, and the t-test for differences between means was applied. No statistically significant differences were established in fresh water and seawater (p>0.05), whereas differences became apparent in marine sediment (p<0.03).
Resumo:
Adsorptive stripping voltammetry carried out in a homogeneous ternary solvent composed of N,N-dimethylformamide, water and ethanol, with alpha-benzoinoxime (alphaBO) as the complexing agent for Mo(VI) and a 0.5 mol L-1 acetic acid - sodium acetate buffer as supporting electrolyte was successfully used for the determination of molybdenum in polyvitamin-polymineral tablets. Tablet samples were analyzed and the results were compared with those obtained both by graphite furnace atomic absorption and by recovery tests, with good correlations, indicating that this may be considered as an alternative procedure for routine determination of Mo(VI) in pharmaceutical samples.
Resumo:
A flow injection on-line pre-concentration system coupled to thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) for cadmium determination at sub μg L-1 levels in seawater samples was developed. The on-line system was evaluated by analysing cadmium containing in a synthetic seawater matrix (2.5% m/v NaCl, 0.5% m/v MgCl2 and 0.8% m/v CaCl2). A sample volume of 2 mL allows determining Cd with a detection limits of 30 ng L-1 (3* σblank/slope), pre-concentration factor of 34 and repeatability of 1,8% (calculated as RSD, N=8 and containing 200 ng L-1 of Cd ).
Resumo:
This study evaluated the level of the metals Pb mg kg-1 and Cd mg kg-1 found in plant species and the contribution of the levels detected in contaminated soils located in the urban area of the city of Santo Amaro, Bahia. Levels were determined by graphite furnace and flame atomic absorption spectrometry. The results showed the presence of Pb and Cd in plant species at levels ranging from 0.18 to 118.2 mg kg-1 and 0.04 to 7.29 mg kg-1, respectively. The concentration values obtained varied according to the plant species and were not strongly influenced by the concentration values detected in the soil.
Resumo:
The application of multivariate calibration techniques to multicomponent analysis by UV-VIS molecular absorption spectrometry is a powerful tool for simultaneous determination of several chemical species. However, when this methodology is accomplished manually, it is slow and laborious, consumes high amounts of reagents and samples, is susceptible to contaminations and presents a high operational cost. To overcome these drawbacks, a flow-batch analyser is proposed in this work. This analyser was developed for automatic preparation of standard calibration and test (or validation) mixtures. It was applied to the simultaneous determination of Cu2+, Mn2+ and Zn2+ in polyvitaminic and polymineral pharmaceutical formulations, using 4-(2-piridilazo) resorcinol as reagent and a UV-VIS spectrophotometer with a photodiode array detector. The results obtained with the proposed system are in good agreement with those obtained by flame atomic absorption spectrometry, which was employed as reference method. With the proposed analyser, the preparation of calibration and test mixtures can be accomplished about four hours, while the manual procedure requires at least two days. Moreover, it consumes smaller amounts of reagents and samples than the manual procedure. After the preparation of calibration and test mixtures, 60 samples h-1 can be carried out with the proposed flow-batch analyser.
Resumo:
The elements called heavy metals when ingested are not completely eliminated from animal bodies and are responsible for chronic and acute intoxications. Sixty-three samples of beer, produced in the states of São Paulo, Paraná, Rio de Janeiro, Rio Grande do Sul, Minas Gerais, and Pará, were analysed for lead and cadmium content by atomic absorption spectrometry with graphite furnace atomization and Zeeman correction. The concentrations of Pb and Cd of dark differed significantly from light beers, being higher in the former. No significant difference was found between the beers produced in predominantly rural areas and the ones produced in industrialized areas. The concentrations of lead and cadmium in all samples were bellow the maximum accepted by present Brazilian regulations and ranged from not detected to 290mugPb/L and from not detected to 14.3mugCd/L. The average concentrations were 37mugPb/L and 1.6mugCd/L.
Resumo:
This study proposes a method of direct and simultaneous determination of the amount of Ca2+ and Mg2+ present in soil extracts using a Calcium Ion-Selective Electrode and by Complexometric Titration (ISE-CT). The results were compared to those obtained by conventional analytical techniques of Complexometric Titration (CT) and Flame Atomic Absorption Spectrometry (FAAS). There were no significant differences in the determination of Ca2+ and Mg2+ in comparison with CT and FAAS, at a 95 % confidence level. Additionally, results of this method were more precise and accurate than of the Interlaboratorial Control (IC).
Resumo:
A tungsten coil atomizer was used to investigate the effect of heating programs with constant or variable drying temperatures on the atomization of Al, Cd, Cr and Pb. The variation of the surface temperature in the tungsten coil furnace can occur during each heating step due to the design of the power supply, that may apply constant voltages during a programmed time. For volatile elements (Cd), losses in sensitivity were observed when the program with a variable temperature was used. On the other hand, these effects are negligible for less volatile elements (Al and Cr) and any tested program, in different acidic media, could be used without appreciable changes in sensitivities. The results allow the establishment of proper heating programs for elements with different thermochemical behavior in the tungsten coil atomizer.
Resumo:
A flow cell assembled on the original geometry of a graphite tube to achieve permanent chemical modifier is proposed. The graphite tube operates as the working electrode. A stainless steel tube, positioned downstream from the working electrode, was used as the auxiliary electrode. The potential value applied on the graphite electrode was measured against a micro reference electrode (Ag/AgCl) inserted into the auxiliary electrode. Palladium solutions in acetate buffer (100 mmol L-1, pH = 4.8), flowing at 0.5 mL min-1 for 60 min was used to perform the electrochemical modification. A mercury solution (1 ng) was used to evaluate the performance of the permanent palladium modifier.
Resumo:
The historical development of atomic spectrometry techniques based on chemical vapor generation by both batch and flow injection sampling formats is presented. Detection via atomic absorption spectrometry (AAS), microwave induced plasma optical emission spectrometry (MIP-OES), inductively coupled plasma optical emission spectrometry (ICP-OES) , inductively coupled plasma mass spectrometry (ICP-MS) and furnace atomic nonthermal excitation spectrometry (FANES) are considered. Hydride generation is separately considered in contrast to other methods of generation of volatile derivatives. Hg ¾ CVAAS (cold vapor atomic absorption spectrometry) is not considered here. The current state-of-the-art, including extension, advantages and limitations of this approach is discussed.
Resumo:
A tubular electrochemical flow-cell for iridium deposition on the inner surface of pyrolytic graphite tube for permanent chemical modification is proposed. A transversal heated graphite tube was used as working electrode, a cylindrical piece of graphite inserted into the graphite tube as auxiliary electrode, and a micro Ag/AgCl(sat) as reference electrode. Iridium solution in 1.0 mol L-1 HCl, flowing at 0.55 mL min-1 for 60 min was used to perform the electrochemical modification. The applied potential to the flow-cell was - 0.700 V vs Ag/AgCl. Scanning electron microscopy images were taken for thermal and electrochemical modified graphite surface in order to evaluate the iridium distribution. Selenium hydride trapping was used to verify the performance of the proposed permanent chemical modifier.
Resumo:
Ultra-trace amounts of Cu(II) were separated and preconcentrated by solid phase extraction on octadecyl-bonded silica membrane disks modified with a new Schiff,s base (Bis- (2-Hydroxyacetophenone) -2,2-dimethyl-1,3-propanediimine) (SBTD) followed by elution and inductively coupled plasma atomic emission spectrometric detection. The method was applied as a separation and detection method for copper(II) in environmental and biological samples. Extraction efficiency and the influence of sample matrix, flow rate, pH, and type and minimum amount of stripping acid were investigated. The concentration factor and detection limit of the proposed method are 500 and 12.5 pg mL-1, respectively.
Resumo:
The atomization behavior of Au, Ag, Bi, Cd, Pb, and Sn from pyrolitic graphite coating (L'vov platform) with the use Pd and Mg solutions, and zirconium coated platform with the analytes in nitric acid 0.2% v/v and in ethanol was investigated. In ethanol medium, the sensitivity gain was three-fold for Bi and Cd using Zr as modifier. Without modifier, the ethanol medium is appropriate only for Au and Cd. In nitric acid medium, the Zr coated platform elevates sensitivity at least two-fold for Bi and Cd. The method was applied to the determination of Ag, Au and Bi of certified steel samples, after on-line preconcentration, sorption on a minicolumn filled with C-18 bonded to silica gel and elution with ethanol. The concentrations obtained agreed with the recommended values.