99 resultados para indirect quantification


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Limiting dilution analysis was used to quantify Trypanosoma cruzi in the lymph nodes, liver and heart of Swiss and C57 B1/10 mice. The results showed that, in Swiss and B1/10 mice infected with T. cruzi Y strain, the number of parasites/mg of tissue increased during the course of the infection in both types of mice, although a grater number of parasites were observed in heart tissue from Swiss mice than from B1/10. With regard to liver tissue, it was observed that the parasite load in the initial phase of infection was higher than in heart. In experiments using T. cruzi Colombian strain, the parasite load in the heart of Swiss and B1/10 mice increased relatively slowly, although high levels of parasitization were nonetheless observable by the end of the infection. As for the liver and lymph nodes, the concentration of parasites was lower over the entire course of infection than in heart. Both strains thus maintained their characteristic tissue tropisms. The limiting dilution assay (LDA) proved to be an appropriate method for more precise quantification of T. cruzi, comparing favorably with other direct microscopic methods that only give approximate scores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An enzyme-linked immunosorbent assay was standardized for the detection of cryptococcal antigen in serum and cerebrospinal fluid. The system was evaluated in clinical samples from patients infected by human immunodeficiency virus with and without previous cryptococcosis diagnosis. The evaluated system is highly sensitive and specific, and when it was compared with latex agglutination there were not significant differences. A standard curve with purified Cryptococcus neoformans antigen was settled down for the antigen quantification in positive samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comparative study of the indirect haemagglutination (IHA), immunofluorescence (IFAT) and immunoenzymatic (ELISA) tests was carried out to determine the prevalence of Toxoplasma gondii antibodies in goats. One hundred seventy-four serum samples were obtained from four goat herds from the region of Uberlândia, State of Minas Gerais. The distribution of the animals, according to their origin, was as follow: 71 from herd I; 39 from herd II; 37 from herd III; and 27 from herd IV. Serum samples were analyzed by IHA, IFAT and ELISA, considering the reactivity of the serum samples at dilution ≥ 1:64 as cut off titer for the three tests. A global seroprevalence of 18.4% was observed, with significantly higher positivity rate in the herd II (66.7%) and older animals (> 36 months). A high and significant positive correlation was found between the titers obtained by the IHA versus IFAT, IHA versus ELISA, and ELISA versus IFAT. Therefore, it can be concluded that the three analyzed tests have shown to be highly concordant and appropriate for epidemiological surveys of Toxoplasma infection in goats. Although the seroprevalence of T. gondii infection in goats is relatively low in this region as compared to other regions of the country, adequate management might be useful and essential to control the infection in the goat herds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to evaluate the Organon Teknika MB/BacT system used for testing indirect susceptibility to the alternative drugs ofloxacin (OFLO), amikacin (AMI), and rifabutin (RIF), and to the usual drugs of standard treatment regimes such as rifampin (RMP), isoniazid (INH), pyrazinamide (PZA), streptomycin (SM), ethambutol (EMB), and ethionamide (ETH), cultures of clinical specimens from 117 patients with pulmonary tuberculosis under multidrug-resistant investigation, admitted sequentially for examination from 2001 to 2002, were studied. Fifty of the Mycobacterium tuberculosis cultures were inoculated into the gold-standard BACTEC 460 TB (Becton Dickinson) for studying resistance to AMI, RIF, and OFLO, and the remaining 67 were inoculated into Lowenstein Jensen (LJ) medium (the gold standard currently used in Brazil) for studying resistance to RMP, INH, PZA, SM, EMB, and ETH. We observed 100% sensitivity for AMI (80.8-100), RIF (80.8-100), and OFLO (78.1-100); and 100% specificity for AMI (85.4-100), RIF (85.4-100), and OFLO (86.7-100) compared to the BACTEC system. Comparing the results obtained in LJ we observed 100% sensitivity for RMP (80-100), followed by INH - 95% (81.8-99.1), EMB - 94.7% (71.9-99.7), and 100% specificity for all drugs tested except for PZA - 98.3 (89.5-99.9) at 95% confidence interval. The results showed a high level of accuracy and demonstrated that the fully automated, non-radiometric MB/BacT system is indicated for routine use in susceptibility testing in public health laboratories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A highly specific pattern of immunofluorescence was noted when sera from Capillaria hepatica-infected rats were tested against the homologous worms and eggs present either in paraffin or cryostat sections from mouse liver. The pattern was represented by a combined apple green fluorescence of the internal contents of worms and eggs, which persisted in serum-dilutions of 1:400 up to 1:1600. Unequivocal fluorescent pattern was observed from 15 days up to 3 months following inoculation of rats with embryonated C. hepatica eggs and such result was confirmed by the ELISA. After the 4th month of infection, the indirect immunofluorescence test turned negative, probably revealing the extinction of parasitism, however the ELISA was contradictory, disclosing high levels of antibodies in this period . The IIF was also negative when control normal rat sera and sera from rats administered by gavage with immature C. hepatica eggs (spurious infection), or for reactions made against Schistosoma mansoni eggs, although a weakly positive pattern occurred with Fasciola hepatica eggs. The indirect immunofluorescence test may be recommended for use with human sera to detect early C. hepatica infection in special clinical instances and in epidemiological surveys, since it is a simple, inexpensive, and reliable test, presenting excellent sensitivity and specificity. Although the diagnosis is positive only during early infection, this is the period when the symptoms are usually more severe and the need for differential diagnosis is greater.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the indirect immunoperoxidase virus neutralization (IPVN) and mouse neutralization test (MNT) to detect antibodies against rabies virus from vaccinated dogs and cattle. The IPVN was set up for the ability to measure 0.5 International Units/ml (IU) of antibody required by the World Health Organization and the Office International des Epizooties as the minimum response for proof of rabies immunization. IPVN was developed and standardized in chicken embryo related (CER) cell line when 141 dog and 110 cattle sera were applied by serial five-fold dilutions (1:5, 1:25, 1:125) as well as the positive and negative reference controls, all added in four adjacent wells, of 96-well microplates. A 50 µl amount of CVS32 strain dilution containing 50-200 TCID50/ml was mixed to each serum dilution, and after 90 min 50 µl of 3 x 10(5) cells/mlcell suspension added to each well. After five days of incubation, the monolayers were fixed and the IPVN test performed. The correlation coefficient between the MNT and IPVN performed in CER cells was r = 0.9949 for dog sera (n = 100) and r = 0.9307 for cattle sera (n = 99), as well as good specificity (94.7%), sensitivity (87.5%), and agreement (96.6%) were also obtained. IPVN technique can adequately identify vaccinated and unvaccinated animals, even from low-responding vaccinated animals, with the advantage of low cost and faster then MNT standard test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Indirect enzyme-linked immunosorbent assays (ELISAs) based on recombinant major surface protein 5 (rMSP5) and initial body (IB) antigens from a Brazilian isolate of Anaplasma marginale were developed to detect antibodies against this rickettsia in cattle. Both tests showed the same sensitivity (98.2%) and specificities (100% for rMSP5 and 93.8% for IB ELISA) which did not differ statistically. No cross-reactions were detected with Babesia bigemina antibodies, but 5 (rMSP5 ELISA) to 15% (IB ELISA) of cross-reactions were detected with B. bovis antibodies. However, such difference was not statistically significant. Prevalences of seropositive crossbred beef cattle raised extensively in Miranda county, state of Mato Grosso do Sul, Brazil, were 78.1% by rMSP5 ELISA and 79.7% by IB ELISA. In the analysis of sera from dairy calves naturally-infected with A. marginale, the dynamics of antibody production was very similar between both tests, with maternal antibodies reaching the lowest levels at 15-30 days, followed by an increase in the mean optical densities in both ELISAs, suggesting the development of active immunity against A. marginale. Results showed that all calves were seropositive by one-year old, characterizing a situation of enzootic stability. The similar performances of the ELISAs suggest that both tests can be used in epidemiological surveys for detection of antibodies to A. marginale in cattle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comparison of the use of indirect immunofluorescence assay (IFA), immunochromatography assay (ICA-BD) and reverse transcription-polymerase chain reaction (RT-PCR) for detecting human respiratory syncytial virus (HRSV) in 306 nasopharyngeal aspirates samples (NPA) was performed in order to assess their analytical performance. By comparing the results obtained using ICA-BD with those using IFA, we found relative indices of 85.0% for sensitivity and 91.2% for specificity, and the positive (PPV) and negative (NPV) predictive values were 85.0% and 91.2%, respectively. The relative indices for sensitivity and specificity as well as the PPV and NPV for RT-PCR were 98.0%, 89.0%, 84.0% and 99.0%, respectively, when compared to the results of IFA. In addition, comparison of the results of ICA-BD and those of RT-PCR yielded relative indices of 79.5% for sensitivity and 95.4% for specificity, as well as PPV and NPV of 92.9% and 86.0%, respectively. Although RT-PCR has shown the best performance, the substantial agreement between the ICA-BD and IFA results suggests that ICA-BD, also in addition to being a rapid and facile assay, could be suitable as an alternative diagnostic screening for HRSV infection in children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous studies have reported genetic differences between wild-caught sylvatic, domestic and laboratory pop-ulations of several Triatominae species. The differences between sylvatic and laboratory colonies parallel are similar to the differences observed between sylvatic and domestic populations. Laboratory colonies are frequently used as references for field populations, but the consequences of founder events on the genetic makeup of laboratory or domestic populations are rarely quantified. Our goal was to quantify the genetic change in Rhodnius pallescens populations artificially submitted to founder effects via laboratory colonization. We compared the genetic makeup of two sylvatic populations and their laboratory descendants using a panel of 10 microsatellite markers. Both sylvatic populations were initially collected from palm trees, but the colonies differed in the number of founder insects and amount of time kept in the laboratory. We evaluated allelic polymorphism, differences between expected and observed heterozygosity, estimates of population differentiation (Fst) and inbreeding (Fis, Fit) and cluster analyses based on Nei's distances. We found a unique genetic structure for each sample population, with significant differentiation between the field insects and each of the laboratory generations. These analyses showed strong founder effects and showed that genetic drift had led to a genetic equilibrium over several generations of isolation. Our results suggest that laboratory colonies of R. pallescens have a different genetic structure than their wild relatives and similar processes likely affect other Triatominae laboratory stocks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to quantify Toxoplasma gondii in tissue samples of serologically positive chickens using real-time polymerase chain reaction (PCR). Of 65 chickens evaluated, 28 were positive for T. gondii antibodies. Brain and heart samples were collected from 26 seropositive chickens and DNA was extracted using Trizol® and amplified using real-time PCR with SYBR® Green. Parasite DNA was detected in 24 of the 26 samples analyzed; the number of positive tissue samples and the parasite quantity did not differ between tissue types. The results confirmed the analytical sensitivity of parasite detection in chicken tissue samples and demonstrated the possibility of using other molecular systems for genotypic analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abdominal angiostrongyliasis is a potentially fatal zoonotic disease with a broad geographical distribution throughout Central and South America. This study assessed the performance of Angiostrongylus costaricensis eggs as the antigen in an indirect immunofluorescence assay for the determination of parasite-specific IgG and IgG1 antibodies. For prevalence studies, an IgG antibody titre > 16 was identified as the diagnostic threshold with the best performance, providing 93.7% sensitivity and 84.6% specificity. Cross reactivity was evaluated with 65 additional samples from patients with other known parasitic infections. Cross reactivity was observed only in samples from individuals infected with Strongyloides stercoralis. For clinical diagnosis, we recommend the determination of IgG only as a screening test. IgG1 determination may be used to increase the specificity of the results for patients with a positive screening test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hepatitis C virus (HCV) can be detected in blood and other bodily fluids, such as saliva, semen and gastric juices. The aim of this study was to compare the HCV viral loads in the serum and saliva of infected patients. Twenty-nine patients with detectable HCV RNA in their serum and saliva were included in this study. The HCV viral loads were determined through quantitative real-time polymerase chain reactions. The median viral RNA levels were 5.78 log10 copies in the serum and 3.32 log10 copies in the saliva. We observed that the salivary HCV viral load was significantly lower than the viral load in the serum. Further studies are required to understand the role of saliva in the diagnosis, management and potential transmission of HCV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Histology is the gold standard for diagnosing acute rejection and hepatitis C recurrence after liver transplantation. However, differential diagnosis between the two can be difficult. We evaluated the role of C4d staining and quantification of hepatitis C virus (HCV) RNA levels in liver tissue. This was a retrospective study of 98 liver biopsy samples divided into four groups by histological diagnosis: acute rejection in patients undergoing liver transplant for hepatitis C (RejHCV+), HCV recurrence in patients undergoing liver transplant for hepatitis C (HCVTx+), acute rejection in patients undergoing liver transplant for reasons other than hepatitis C and chronic hepatitis C not transplanted (HCVTx-). All samples were submitted for immunohistochemical staining for C4d and HCV RNA quantification. Immunoexpression of C4d was observed in the portal vessels and was highest in the HCVTx- group. There was no difference in C4d expression between the RejHCV+ and HCVTx+ groups. However, tissue HCV RNA levels were higher in the HCVTx+ group samples than in the RejHCV+ group samples. Additionally, there was a significant correlation between tissue and serum levels of HCV RNA. The quantification of HCV RNA in liver tissue might prove to be an efficient diagnostic test for the recurrence of HCV infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human herpesvirus 6 (HHV-6) may cause severe complications after haematopoietic stem cell transplantation (HSCT). Monitoring this virus and providing precise, rapid and early diagnosis of related clinical diseases, constitute essential measures to improve outcomes. A prospective survey on the incidence and clinical features of HHV-6 infections after HSCT has not yet been conducted in Brazilian patients and the impact of this infection on HSCT outcome remains unclear. A rapid test based on real-time quantitative polymerase chain reaction (qPCR) has been optimised to screen and quantify clinical samples for HHV-6. The detection step was based on reaction with TaqMan® hydrolysis probes. A set of previously described primers and probes have been tested to evaluate efficiency, sensitivity and reproducibility. The target efficiency range was 91.4% with linearity ranging from 10-106 copies/reaction and a limit of detection of five copies/reaction or 250 copies/mL of plasma. The qPCR assay developed in the present study was simple, rapid and sensitive, allowing the detection of a wide range of HHV-6 loads. In conclusion, this test may be useful as a practical tool to help elucidate the clinical relevance of HHV-6 infection and reactivation in different scenarios and to determine the need for surveillance.