66 resultados para electric variables measurement
Resumo:
Studies have shown that the age of 12 was determined as the age of global monitoring of caries for international comparisons and monitoring of disease trends. The aimed was to evaluate the prevalence of dental caries, fluorosis and periodontal condition and their relation with socioeconomic factors among schoolchildren aged twelve in the city of Manaus, AM. This study with a probabilistic sample of 661 children was conducted, 609 from public and 52 from private schools, in 2008. Dental caries, periodontal condition and dental fluorosis were evaluated. In order to obtain the socioeconomic classification of each child (high, upper middle, middle, lower middle, low and lower low socioeconomic classes), the guardians were given a questionnaire. The mean decayed teeth, missing teeth, and filled teeth (DMFT) found at age twelve was 1.89. It was observed that the presence of dental calculus was the most severe periodontal condition detected in 39.48%. In relation to dental fluorosis, there was a low prevalence in the children examined, i.e., the more pronounced lines of opacity only occasionally merge, forming small white areas. The study showed a significant association of 5% among social class with dental caries and periodontal condition. In schoolchildren of Manaus there are low mean of DMFT and fluorosis, but a high occurrence of gingival bleeding.
Resumo:
Species distribution modeling has relevant implications for the studies of biodiversity, decision making about conservation and knowledge about ecological requirements of the species. The aim of this study was to evaluate if the use of forest inventories can improve the estimation of occurrence probability, identify the limits of the potential distribution and habitat preference of a group of timber tree species. The environmental predictor variables were: elevation, slope, aspect, normalized difference vegetation index (NDVI) and height above the nearest drainage (HAND). To estimate the distribution of species we used the maximum entropy method (Maxent). In comparison with a random distribution, using topographic variables and vegetation index as features, the Maxent method predicted with an average accuracy of 86% the geographical distribution of studied species. The altitude and NDVI were the most important variables. There were limitations to the interpolation of the models for non-sampled locations and that are outside of the elevation gradient associated with the occurrence data in approximately 7% of the basin area. Ceiba pentandra (samaúma), Castilla ulei (caucho) and Hura crepitans (assacu) is more likely to occur in nearby water course areas. Clarisia racemosa (guariúba), Amburana acreana (cerejeira), Aspidosperma macrocarpon (pereiro), Apuleia leiocarpa (cumaru cetim), Aspidosperma parvifolium (amarelão) and Astronium lecointei (aroeira) can also occur in upland forest and well drained soils. This modeling approach has potential for application on other tropical species still less studied, especially those that are under pressure from logging.
Resumo:
OBJECTIVE: Risk stratification of patients with nonsustained ventricular tachycardia (NSVT) and chronic chagasic cardiomyopathy (CCC). METHODS: Seventy eight patients with CCC and NSVT were consecutively and prospectively studied. All patients underwent to 24-hour Holter monitoring, radioisotopic ventriculography, left ventricular angiography, and electrophysiologic study. With programmed ventricular stimulation. RESULTS: Sustained monomorphic ventricular tachycardia (SMVT) was induced in 25 patients (32%), NSVT in 20 (25.6%) and ventricular fibrillation in 4 (5.1%). In 29 patients (37.2%) no arrhythmia was inducible. During a 55.7-month-follow-up, 22 (28.2%) patients died, 16 due to sudden death, 2 due to nonsudden cardiac death and 4 due to noncardiac death. Logistic regression analysis showed that induction was the independent and main variable that predicted the occurrence of subsequent events and cardiac death (probability of 2.56 and 2.17, respectively). The Mantel-Haenszel chi-square test showed that survival probability was significantly lower in the inducible group than in the noninductible group. The percentage of patients free of events was significantly higher in the noninducible group. CONCLUSION: Induction of SMVT during programmed ventricular stimulation was a predictor of arrhythmia occurrence cardiac death and general mortality in patients with CCC and NSVT.
Resumo:
OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.
Resumo:
OBJECTIVE: To determine technical procedures and criteria used by Brazilian physicians for measuring blood pressure and diagnosing hypertension. METHODS: A questionnaire with 5 questions about practices and behaviors regarding blood pressure measurement and the diagnosis of hypertension was sent to 25,606 physicians in all Brazilian regions through a mailing list. The responses were compared with the recommendations of a specific consensus and descriptive analysis. RESULTS: Of the 3,621 (14.1%) responses obtained, 57% were from the southeastern region of Brazil. The following items were reported: use of an aneroid device by 67.8%; use of a mercury column device by 14.6%; 11.9% of the participants never calibrated the devices; 35.7% calibrated the devices at intervals < 1 year; 85.8% measured blood pressure in 100% of the medical visits; 86.9% measured blood pressure more than once and on more than one occasion. For hypertension diagnosis, 55.7% considered the patient's age, and only 1/3 relied on consensus statements. CONCLUSION: Despite the adequate frequency of both practices, it was far from that expected, and some contradictions between the diagnostic criterion for hypertension and the number of blood pressure measurements were found. The results suggest that, to include the great majority of the medical professionals, disclosure of consensus statements and techniques for blood pressure measurement should go beyond the boundaries of medical events and specialized journals.
Resumo:
OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.
Resumo:
OBJECTIVE: To assess blood pressure measurement by health professionals of a public hospital in São Paulo State. METHODS: Semi-structured interviews and direct observation were performed with a verification list according to the criteria reported by Perloff et al. One hundred and five health professionals took part in the study. After measuring blood pressure, the level of concordance between the way the procedure was performed and the recommended one was assessed. RESULTS: Nurses and nurse's aides abided by 40% of the recommended procedures for adequate blood pressure measurement. The other categories of health professionals (nursing and medicine teachers, physicians, residents, and nursing students) abided by approximately 70%. CONCLUSION: Permanent educational activities aiming at standardizing blood pressure measurement should be implemented among the different categories of health professionals.
Resumo:
OBJECTIVE: To assess the behavior of cardiac variables in animals exposed to cigarette smoke. METHODS: Two groups of Wistar rats were studied as follows: control group (C), comprising 28 animals; and smoking group (S), comprising 23 animals exposed to cigarette smoke for 30 days. Left ventricular cardiac function was assessed in vivo with transthoracic echocardiography, and myocardial performance was analyzed in vitro in preparations of isolated left ventricular papillary muscle. The cardiac muscle was assessed in isometric contractions with an extracellular calcium concentration of 2.5 mmol/L. RESULTS: No statistical difference was observed in the values of the body variables of the rats and in the mechanical data obtained from the papillary muscle between the control and smoking groups. The values of left ventricular systolic diameter were significantly greater in the smoking animals than in the control animals (C= 3.39 ± 0.4 mm and S= 3.71 ± 0.51 mm, P=0.02). A significant reduction was observed in systolic shortening fraction (C= 56.7 ± 4.2% and S= 53.5 ± 5.3%, P=0.02) and in ejection fraction (C= 0.92 ± 0.02 and S= 0.89 ± 0.04, P=0.01). CONCLUSION: The rats exposed to cigarette smoke had a reduction in left ventricular systolic function, although their myocardial function was preserved.
Association between Angiotensin-Converting Enzyme Inhibitors and Troponin in Acute Coronary Syndrome
Resumo:
Background:Cardiovascular disease is the leading cause of mortality in the western world and its treatment should be optimized to decrease severe adverse events.Objective:To determine the effect of previous use of angiotensin-converting enzyme inhibitors on cardiac troponin I measurement in patients with acute coronary syndrome without ST-segment elevation and evaluate clinical outcomes at 180 days.Methods:Prospective, observational study, carried out in a tertiary center, in patients with acute coronary syndrome without ST-segment elevation. Clinical, electrocardiographic and laboratory variables were analyzed, with emphasis on previous use of angiotensin-converting enzyme inhibitors and cardiac troponin I. The Pearson chi-square tests (Pereira) or Fisher's exact test (Armitage) were used, as well as the non-parametric Mann-Whitney's test. Variables with significance levels of <10% were submitted to multiple logistic regression model.Results:A total of 457 patients with a mean age of 62.1 years, of whom 63.7% were males, were included. Risk factors such as hypertension (85.3%) and dyslipidemia (75.9%) were the most prevalent, with 35% of diabetics. In the evaluation of events at 180 days, there were 28 deaths (6.2%). The statistical analysis showed that the variables that interfered with troponin elevation (> 0.5 ng / mL) were high blood glucose at admission (p = 0.0034) and ST-segment depression ≥ 0.5 mm in one or more leads (p = 0.0016). The use of angiotensin-converting inhibitors prior to hospitalization was associated with troponin ≤ 0.5 ng / mL (p = 0.0482). The C-statistics for this model was 0.77.Conclusion:This study showed a correlation between prior use of angiotensin-converting enzyme inhibitors and reduction in the myocardial necrosis marker troponin I in patients admitted for acute coronary syndrome without ST-segment elevation. However, there are no data available yet to state that this reduction could lead to fewer severe clinical events such as death and re-infarction at 180 days.
Resumo:
Background: Heart failure prediction after acute myocardial infarction may have important clinical implications. Objective: To analyze the functional echocardiographic variables associated with heart failure in an infarction model in rats. Methods: The animals were divided into two groups: control and infarction. Subsequently, the infarcted animals were divided into groups: with and without heart failure. The predictive values were assessed by logistic regression. The cutoff values predictive of heart failure were determined using ROC curves. Results: Six months after surgery, 88 infarcted animals and 43 control animals were included in the study. Myocardial infarction increased left cavity diameters and the mass and wall thickness of the left ventricle. Additionally, myocardial infarction resulted in systolic and diastolic dysfunction, characterized by lower area variation fraction values, posterior wall shortening velocity, E-wave deceleration time, associated with higher values of E / A ratio and isovolumic relaxation time adjusted by heart rate. Among the infarcted animals, 54 (61%) developed heart failure. Rats with heart failure have higher left cavity mass index and diameter, associated with worsening of functional variables. The area variation fraction, the E/A ratio, E-wave deceleration time and isovolumic relaxation time adjusted by heart rate were functional variables predictors of heart failure. The cutoff values of functional variables associated with heart failure were: area variation fraction < 31.18%; E / A > 3.077; E-wave deceleration time < 42.11 and isovolumic relaxation time adjusted by heart rate < 69.08. Conclusion: In rats followed for 6 months after myocardial infarction, the area variation fraction, E/A ratio, E-wave deceleration time and isovolumic relaxation time adjusted by heart rate are predictors of heart failure onset.
Resumo:
Abstract Background: Metabolic syndrome (MetS) is associated with a higher risk of all-cause mortality. High-sensitivity C-reactive protein (hsCRP) is a prototypic marker of inflammation usually increased in MetS. Women with MetS-related diseases present higher hsCRP levels than men with MetS-related diseases, suggesting sex differences in inflammatory markers. However, it is unclear whether serum hsCRP levels are already increased in men and/or women with MetS risk factors and without overt diseases or under pharmacological treatment. Objective: To determine the impact of the number of MetS risk factors on serum hsCRP levels in women and men. Methods One hundred and eighteen subjects (70 men and 48 women; 36 ± 1 years) were divided into four groups according to the number of MetS risk factors: healthy group (CT; no risk factors), MetS ≤ 2, MetS = 3, and MetS ≥ 4. Blood was drawn after 12 hours of fasting for measurement of biochemical variables and hsCRP levels, which were determined by immunoturbidimetric assay. Results: The groups with MetS risk factors presented higher serum hsCRP levels when compared with the CT group (p < 0.02). There were no differences in hsCRP levels among groups with MetS risk factors (p > 0.05). The best linear regression model to explain the association between MetS risk factors and hsCRP levels included waist circumference and HDL cholesterol (r = 0.40, p < 0.01). Women with MetS risk factors presented higher hsCRP levels when compared with men (psex < 0.01). Conclusions: Despite the absence of overt diseases and pharmacological treatment, subjects with MetS risk factors already presented increased hsCRP levels, which were significantly higher in women than men at similar conditions.
Resumo:
Abstract Background: Tobacco smoke exposure is an important risk factor for cardiac remodeling. Under this condition, inflammation, oxidative stress, energy metabolism abnormalities, apoptosis, and hypertrophy are present. Pentoxifylline has anti‑inflammatory, anti-apoptotic, anti-thrombotic and anti-proliferative properties. Objective: The present study tested the hypothesis that pentoxifylline would attenuate cardiac remodeling induced by smoking. Methods: Wistar rats were distributed in four groups: Control (C), Pentoxifylline (PX), Tobacco Smoke (TS), and PX-TS. After two months, echocardiography, invasive blood pressure measurement, biochemical, and histological studies were performed. The groups were compared by two-way ANOVA with a significance level of 5%. Results: TS increased left atrium diameter and area, which was attenuated by PX. In the isolated heart study, TS lowered the positive derivate (+dp/dt), and this was attenuated by PX. The antioxidants enzyme superoxide dismutase and glutathione peroxidase were decreased in the TS group; PX recovered these activities. TS increased lactate dehydrogenase (LDH) and decreased 3-hydroxyacyl Coenzyme A dehydrogenases (OH-DHA) and citrate synthase (CS). PX attenuated LDH, 3-OH-DHA and CS alterations in TS-PX group. TS increased IL-10, ICAM-1, and caspase-3. PX did not influence these variables. Conclusion: TS induced cardiac remodeling, associated with increased inflammation, oxidative stress, apoptosis, and changed energy metabolism. PX attenuated cardiac remodeling by reducing oxidative stress and improving cardiac bioenergetics, but did not act upon cardiac cytokines and apoptosis.
Resumo:
We studied the reproductive biology of a population of Pseudis minuta Günther, 1858 from Reserva Biológica do Lami (30º 15' S; 51º 05' W), Porto Alegre, southern Brazil. We assessed the spatial and temporal distribution of individuals (males, females, juveniles) and explored potential relationships with environmental variables. Field activities encompassed bimonthly surveys in three semi-permanent ponds, each one during approximately two days and two nights, from August 2004 to July 2005. We recorded differences in the sites used by males, females and juveniles, with males occupying deeper and more distant places from the border. The temporal distributions of individuals, calling sites and amplectant pairs indicated that the reproductive activity of P. minuta is related to some of the studied abiotic factors. Calling males presented statistical differences in relation to non-calling males for all daily abiotic variables analyzed (air temperature, water temperature, relative humidity and rainfall), as well as to monthly temperature and rainfall. The number of active males, females and juveniles was influenced by at least one of the daily or monthly environmental variables analyzed. We conclude that the reproduction in this species is seasonal and may be partially determined by abiotic factors.
Resumo:
Between January and March 1998, a cross-sectional survey was carried out in four rural communities in Honduras, Central America. We examined the prevalence and intensity of Ascaris lumbricoides and Trichuris trichiura infections among 240 fecal specimens, and the association between selected socio-demographic variables and infection for 62 households. The overall prevalence of A. lumbricoides and T. trichiura was 45% (95% CI 39.0-51.9) and 38% (95% CI 31.8-44.4) respectively. The most intense infections for Ascaris and Trichuris were found in children aged 2-12 years old. By univariate analysis variables associated with infections of A. lumbricoides were: number of children 2-5 years old (p=0.001), level of formal education of respondents (p=0.01), reported site of defecation of children in households (p=0.02), households with children who had a recent history of diarrhea (p=0.002), and the location of households (p=0.03). Variables associated with both A. lumbricoides and T. trichiura infection included: number of children 6-14 years old (p=0.01, p=0.04, respectively), ownership of a latrine (p=0.04, p=0.03, respectively) and coinfection with either helminth (p=0.001, p=0.001, respectively). By multivariate analysis the number of children 2-5 years living in the household, (p=0.01, odds ratio (OR)=22.2), children with a recent history of diarrhea (p=0.0, OR=39.8), and infection of household members with T. trichiura (p=0.02, OR=16.0) were associated with A. lumbricoides infection. The number of children 6-14 years old in the household was associated with both A. lumbricoides and T. trichiura infection (p=0.04, p=0.01, OR=19.2, OR=5.2, respectively).
Resumo:
The immature stages of Ochlerotatus albifasciatus develop in temporary pools. The present study aims at evaluating the seasonal dynamics of the aquatic stages of this mosquito, also analyzing the relationship among their presence and breeding success to some relevant climatic and environmental variables in the ephemeral rain pools of an urban park. Nineteen cohorts of O. albifasciatus that developed synchronously after rain events were recorded in all seasons. The proportions of mosquito-positive pools were significantly higher during the fall-winter period than in the spring-summer months (p < 0.001). The presence of this mosquito species was positively related to the amount of rain (p < 0.001), whereas negatively correlated to air temperature (p < 0.05) within a 5.2 to 29.7ºC range. The distribution of the number of cohorts per pool throughout the year was grouped (variance/mean: 3.96), indicating that these habitats were not equally suitable as breeding sites. The immature stages of O. albifasciatus were detected in pools belonging to all of the categories of surface area, depth, duration, vegetation cover, and insolation. However, the proportion of pools where immature mosquitoes were detected was positively and significantly related to surface, depth, duration, and vegetation cover. On the other hand, the proportion of mosquito-positive pools was higher at an intermediate insolation degree. Our results suggest that although preimaginal stages were present in all seasons, high temperatures may be unfavorable to larval development, and substrate vegetation may regulate water temperature. The positive relationship between the proportion of mosquito-positive pools and pool size and duration might reflect a strategy of O. albifasciatus to accomplish immature development.