70 resultados para Validation of measures
Resumo:
This work describes a validation of an analytical procedure for the analysis of petroleum hydrocarbons in marine sediment samples. The proposed protocol is able to measure n-alkanes and polycyclic aromatic hydrocarbons (PAH) in samples at concentrations as low as 30 ng/g, with a precision better than 15% for most of analytes. The extraction efficiency of fortified sediments varied from 65.1 to 105.6% and 59.7 to 97.8%, for n-alkanes and PAH in the ranges: C16 - C32 and fluoranthene - benzo(a)pyrene, respectively. The analytical protocol was applied to determine petroleum hydrocarbons in sediments collected from a marine coastal zone.
Resumo:
This work reports the validation of an analytical UV spectrophotometric method to assay dexamethasone in tablets (assay and dissolution studies). The method was linear in the range between 1 and 30 µg mL-1 presenting a good correlation coefficient (r = 0.9998, n = 7). Precision and accuracy analysis showed low relative standard deviation (< 2.00%) and good percentual recoveries (95-105%). The procedure was linear, accurate, precise, and robust. The method is simple, and it has low cost. It does not use polluting reagents and can be applied in dissolution studies, being an adequate alternative to assay dexamethasone in tablets.
Resumo:
A dissolution test for telithromycin tablets was validated and developed. In order to choose the most discriminatory one, the conditions to carry out are 900 mL of sodium phosphate buffer at pH 7.5, paddles at 50 rpm stirring speed, time test set to 60 min and using USP apparatus 2 with paddles. The UV spectrophotometric method for determination of telithromycin released was developed and validated. The method presents linearity (r = 1) in the concentration range of 20-60 µg/mL. Precision and recoveries were good, 100.62 and 97.06%, respectively. The method was successfully used for the dissolution test of telithromycin tablets.
Resumo:
A gas chromatographic method has been developed for the assay of fluvastatin sodium (FLU). FLU was silylated with N,O-bis(trimethylsilyl)trifluoroacetamide-1% trimethylchlorosilane at 90 ºC for 30 min and analysed in a DB-1 column by capillary gas chromatograph with a flame ionization detector. The method was validated. The assay was linear over the concentration range at 10.0 to 50.0 µg mL-1. The limit of detection and the limit of quantitation were 1.0 and 3.0 µg mL-1, respectively. The recoveries of FLU derivatives were in the range of 99.25-99.80%. In inter-day and intra-day analysis, the values of relative standard deviation (%) and the relative mean error (%) were found between 0.20-0.80% and -0.20-0.75%, respectively. The developed method was succesfully applied to analyze the FLU content in tablet formulation. The results were statistically compared with those obtained by the official method, and no significant difference was found between the two methods. Therefore, it can be recommended for the quality control assay of FLU in pharmaceutical industry.
Resumo:
A reversed-phase liquid chromatographic (LC) and ultraviolet (UV) spectrophotometric methods were developed and validated for the assay of bromopride in oral and injectable solutions. The methods were validated according to ICH guideline. Both methods were linear in the range between 5-25 μg mL-1 (y = 41837x - 5103.4, r = 0.9996 and y = 0.0284x - 0.0351, r = 1, respectively). The statistical analysis showed no significant difference between the results obtained by the two methods. The proposed methods were found to be simple, rapid, precise, accurate, and sensitive. The LC and UV methods can be used in the routine quantitative analysis of bromopride in oral and injectable solutions.
Resumo:
The objective of this research was to develop and validate an alternative analytical method for quantitative determination of levofloxacin in tablets and injection preparations. The calibration curves were linear over a concentration range from 3.0 to 8.0 μg mL-1. The relative standard deviation was below 1.0% for both formulations and average recovery was 101.42 ± 0.45% and 100.34 ± 0.85% for tablets and injection formulations, respectively. The limit of detection and limit of quantitation were 0.08 and 0.25 μg mL-1, respectively. It was concluded that the developed method is suitable for the quality control of levofloxacin in pharmaceuticals formulations.
Resumo:
A sensitive RP-HPLC method with UV detection successfully measured phenol(s) in an ointment containing 3% Stryphnodendron adstringens extract. Chromatography used acetonitrile (0.05% trifluoroacetic acid):water (0.05% trifluoroacetic acid) (v/v), flow rate 0.8 mL min-1. Quantitation was accomplished by the external-standard method. Linearity for 2.00 to 16.00 μg mL-1 (gallic acid) and 1.14 to 18.24 μg mL-1 (gallocatechin) was established. Intra- and inter-day precision levels were under 5%. LOD and LOQ were 0.231 and 0.770 μg mL-1 (gallic acid) and 0.151 and 0.504 μg mL-1 (gallocatechin), respectively. Determination of phenols was unaffected by product excipients.
Resumo:
A dissolution test for in vitro evaluation of tablet dosage forms containing 10 mg of rupatadine was developed and validated by RP-LC. A discriminatory dissolution method was established using apparatus paddle at a stirring rate of 50 rpm with 900 mL of deaerated 0.01 M hydrochloric acid. The proposed method was validated yielding acceptable results for the parameters evaluated, and was applied for the quality control analysis of rupatadine tablets, and to evaluate the formulation during an accelerated stability study. Moreover, quantitative analyses were also performed, to compare the applicability of the RP-LC and the LC-MS/MS methods.
Resumo:
For determination of aliskiren in commercial samples, an analytical UV spectrophotometric method was developed and validate according to ICH guideline. The method was linear in the range between 40 and 100 μg mL-1 (r² = 0.9997, n = 7) and exhibited suitable specificity, accuracy, precision, and robustness. It is simple, it has low cost, and it has low use polluting reagents. Therefore, the proposed method was successfully applied for the assay and dissolution studies of aliskiren in tablet dosage forms, and the results were compared to a validated RP-LC method, showing non-significant difference (P > 0.05).
Resumo:
A LC-ESI-MS/MS method was developed and validated according to the European Union decision 2002/657/EC, for the determination of tetracyclines (TCs) in chicken-muscle since Europe is one of the main markets for Brazilian products. Linearity of r > 0.9979, limits of quantification in the range of 7.0-35.0 ng/g, average recoveries of 89.38 - 106.27%, within-day and between-day precision were adequate for all TCs. The decision limit and the detection capability were 93.00-106.46 ng/g and 95.84-114.38 ng/g, respectively. This method is suitable for application in surveillance programmes of residues of TCs in chicken-muscle samples.
Resumo:
An HPLC method was developed and validated aiming to quantify the cyclosporine-A incorporated into intraocular implants, released from them; and in direct contact with the degradation products of PLGA. The separation was carried out in isocratic mode using acetonitrile/water (70:30) as mobile phase, a C18 column at 80 ºC and UV detection at 210 nm. The method provided selectivity based on resolution among peaks. It was linear over the range of 2.5-40.0 µg/mL. The quantitation and detection limits were 0.8 and 1.2 µg/mL, respectively. The recovery was 101.8% and intra-day and inter-day precision was close to 2%.
Resumo:
The present work describes a novel stability-indicating reversed-phase ultra performance liquid chromatography method for the separation and quantification of rosuvastatin (RSV) and its related impurities in the pharmaceutical dosage forms under forced degradation conditions. An unknown degradation impurity detected in the acid degradation was identified by using quadrupole time-of-flight mass spectrometry. The chromatographic separation was carried out on C-18 column (100 x 2.1 mm, 1.7 μm) using isocratic elution with methanol and 0.1% trifluoroacetic acid (50:50). The total run time was 12 min within which RSV as well as all related impurities and degradation products were separated. The developed method was validated for RSV and related impurities in pharmaceutical dosage forms.
Resumo:
This work describes the development and validation of a dissolution test for 60 mg of diltiazem hydrochloride in immediate release capsules. The best dissolution in vitro profile was achieved using potassium phosphate buffer at pH 6.8 as the dissolution medium and paddle as the apparatus at 50 rpm. The drug concentrations in the dissolution media were determined by UV spectrophotometry and HPLC and a statistical analysis revealed that there were significant differences between HPLC and spectrophotometry. This study illustrates the importance of an official method for the dissolution test, since there is no official monograph for diltiazem hydrochloride in capsules.
Resumo:
This study describes the validation of a spectrophotometric method to estimate oligonucleotides association with cationic nanoemulsions. Phosphodiester and phosphorothioate oligonucleotides targeting Plasmodium falciparum topoisomerase II were analyzed at 262 nm. Linear response (r > 0.998) was observed from 0.4 to 1.0 nmol/mL, the relative standard deviation values for the intra- and inter-days precision were lower than 2.6% and the recovery ranged from 98.8 to 103.6% for both oligonucleotides. The association efficiency was estimated based on an ultrafiltration/centrifugation method. Oligonucleotides recovery through 30 kDa-membranes was higher than 92%. The extent of oligonucleotides association (42 to 98%) varied with the composition of nanoemulsions
Resumo:
A method using LC/ESI-MS/MS for the quantitative analysis of Ochratoxin A in roasted coffee was described. Linearity was demonstrated (r = 0.9175). The limits of detection and quantification were 1.0 and 3.0 ng g-1, respectively. Trueness, repeatability and intermediate precision values were 89.0-108.8%; 2.4-13.7%; 12.5-17.8%, respectively. To the best of our knowledge, this is the first report in which Ochratoxin A in roasted coffee is analysed by LC/ESI-MS/MS, contributing to the field of mycotoxin analysis, and it will be used for future production of Certified Reference Material.