42 resultados para Single-Photon Emission-Computed


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract:INTRODUCTION:The therapeutic scheme of triclabendazole (TCBZ), the recommended anthelmintic against Fasciola hepatica , involves 10mg/kg of body weight administered in a single dose; however, clinical trials in children are scarce. We evaluated the efficacy and tolerability of 2 schemes of TCBZ.METHODS: Eighty-four Peruvian children with F. hepatica eggs in their stools were allocated into 2 groups: 44 received 2 dosages of 7.5mg/kg each with a 12-h interval (Group I), and 40 received a single 10-mg/kg dose (Group II). Evaluation of efficacy was based on the presence of eggs in stools, and tolerability was based on the presence of symptoms and signs post-treatment.RESULTS: A parasitological cure was obtained in 100% of individuals from Group I and 95% of individuals from Group II. The most common adverse event was biliary colic.CONCLUSIONS: The tested scheme was efficacious and tolerable, and it might be an optimal scheme in the region. To the best of our knowledge, this represents the largest series of children treated with TCBZ in a non-hospital setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract: INTRODUCTION : Molecular analyses are auxiliary tools for detecting Koch's bacilli in clinical specimens from patients with suspected tuberculosis (TB). However, there are still no efficient diagnostic tests that combine high sensitivity and specificity and yield rapid results in the detection of TB. This study evaluated single-tube nested polymerase chain reaction (STNPCR) as a molecular diagnostic test with low risk of cross contamination for detecting Mycobacterium tuberculosis in clinical samples. METHODS: Mycobacterium tuberculosis deoxyribonucleic acid (DNA) was detected in blood and urine samples by STNPCR followed by agarose gel electrophoresis. In this system, reaction tubes were not opened between the two stages of PCR (simple and nested). RESULTS: STNPCR demonstrated good accuracy in clinical samples with no cross contamination between microtubes. Sensitivity in blood and urine, analyzed in parallel, was 35%-62% for pulmonary and 41%-72% for extrapulmonary TB. The specificity of STNPCR was 100% in most analyses, depending on the type of clinical sample (blood or urine) and clinical form of disease (pulmonary or extrapulmonary). CONCLUSIONS: STNPCR was effective in detecting TB, especially the extrapulmonary form for which sensitivity was higher, and had the advantage of less invasive sample collection from patients for whom a spontaneous sputum sample was unavailable. With low risk of cross contamination, the STNPCR can be used as an adjunct to conventional methods for diagnosing TB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aims of this study were to evaluate the role of high resolution computed tomography of the torax in detecting abnormalities in chronic asthmatic patients and to determine the behavior of these lesions after at least one year. METHOD: Fourteen persistent asthmatic patients with a mean forced expiratory volume in 1-second that was 63% of predicted and a mean forced expiratory volume in 1-second /forced vital capacity of 60% had two high resolution computed tomographys separated by an interval of at least one year. RESULTS: All 14 patients had abnormalities on both scans. The most common abnormality was bronchial wall thickening, which was present in all patients on both computed tomographys. Bronchiectasis was suggested on the first computed tomography in 5 of the 14 (36%) patients, but on follow-up, the bronchial dilatation had disappeared in 2 and diminished in a third. Only one patient had any emphysematous changes; a minimal persistent area of paraseptal emphysema was present on both scans. In 3 patients, a "mosaic" appearance was observed on the first scan, and this persisted on the follow-up computed tomography. Two patients had persistent areas of mucoid impaction. In a third patient, mucus plugging was detected only on the second computed tomography. CONCLUSIONS: We conclude that there are many abnormalities on the high resolution computed tomography of patients with persistent asthma. Changes suggestive of bronchiectasis, namely bronchial dilatation, frequently resolve spontaneously. Therefore, the diagnosis of bronchiectasis by high resolution computed tomography in asthmatic patients must be made with caution, since bronchial dilatation can be reversible or can represent false dilatation. Nonsmoking chronic asthmatic subjects in this study had no evidence of centrilobular or panacinar emphysema.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report the experience of a radiology department in the use of computed tomography - guided cutting needle biopsy of pulmonary nodules, by evaluating diagnostic yield and incidence of complications. METHODS: This is a retrospective analysis of 52 consecutive patients who underwent lung lesion biopsy guided by computed tomography, performed between May 1997 and May 2000. Thirty-five patients were male and 17 were female, with ages ranging from 5 to 85 years (median, 62 years). The size of the lesions ranged from 1.8 to 15 cm (median, 5.4 cm). RESULTS: In a total of 52 biopsies of lung lesions, 51 biopsies (98.1%) supplied appropriate material for histopathological diagnosis, with 9 diagnosed (17.3%) as benign and 42 (80.8%) as malignant lesions. Specific diagnosis was obtained in 44 (84.6%) biopsies: 4 benign (9.1%) and 40 (90.9%) malignant lesions. The sensitivity, specificity, and accuracy of the cutting needle biopsies for determining presence of malignancy were 96.8%, 100%, and 97.2%, respectively. Complications occurred in 9 cases (17.3%), including 6 cases (11.5%) of small pneumothorax, 1 (1.9%) of hemoptysis, 1 (1.9%) of pulmonary hematoma, and 1 (1.9%) of thoracic wall hematoma. All had spontaneous resolution. There were no complications requiring subsequent intervention. CONCLUSION: The high sensitivity and specificity of the method and the low rate of complications have established cutting needle biopsy as an efficient and safe tool for the diagnosis of lung lesions. In our hospital, cutting needle biopsy is considered a reliable procedure for the evaluation of indeterminate pulmonary nodules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Pleuropulmonary changes are common following coronary artery bypass grafting surgery performed with a saphenous vein graft, with or without an internal mammary artery. The presence of atelectasis or pleural effusions reflects the thoracic trauma. PURPOSE: To define the postoperative incidence of changes in the lung and in the pleural space and to evaluate the influence of the trauma. METHODS: Thirty patients underwent elective coronary artery bypass grafting surgery (8 saphenous vein grafts and 22 saphenous vein grafts and internal mammary artery grafts with pleurotomy). Chest tubes in the left pleural space were used in all internal mammary artery patients. On the second (day 2) and seventh (day 7) postoperative day, patients underwent a computed tomography, and pleural effusions were rated as follows: grade 0 = no fluid to grade 4 = fluid in more than 75% of the hemithorax. Atelectasis was rated as follows: laminar = 1, segmental = 3, and lobar = 10 points. RESULTS: All patients had pleural effusion or atelectasis. Between day 2 and day 7, the number of patients with effusions or atelectasis on the right side decreased (P < 0.05). The incidence of effusions on day 2 in the saphenous vein graft group (87.5%) was higher (P < 0.05) than in the internal mammary artery group (52.3%). The incidence of atelectasis in the lower right lobe decreased (P < 0.05) from 86.7% (day 2) to 26.7% (day 7). The degree of atelectasis in both sides did not differ on day 2 (P = 0.42) but did on day 7 (P < 0.0001). There was a decrease in the atelectasis from day 2 to day 7 on the right side (P < 0.001), but not on the left (P = 0.21). On day 2 there was a relationship between atelectasis and effusion on the right (P = 0.04), but not on the left (P = 0.113). CONCLUSION: The present series demonstrates that there is a high incidence of both minimal pleural effusion and atelectasis after coronary artery bypass grafting surgery, which drops on the right side from day 2 to day 7 post surgery. Factors that contribute to the persistence of changes on the left side include the thoracic trauma and the presence of chest tubes and pericardial effusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report the experience of a radiology department in the use of computed tomography guided biopsies of mediastinal lesions with fine and cutting needles, describing the differences between them. The results of adequacy of the sample and histologic diagnoses are presented according to the type of needle used. METHODS: We present a retrospective study of mediastinal biopsies guided by computed tomography performed from January 1993 to December 1999. Eighty-six patients underwent mediastinal biopsy in this period, 37 with cutting needles, 38 with fine needles, and 11 with both types (total of 97 biopsies). RESULTS: In most cases, it was possible to obtain an adequate sample (82.5%) and specific diagnosis (67.0%). Cutting-needle biopsy produced a higher percentage of adequate samples (89.6% versus 75.5%, P = 0.068) and of specific diagnosis (81.3% versus 53.1%, P = 0.003) than fine-needle biopsy. There were no complications that required intervention in either group. CONCLUSION: Because they are practical, safe, and can provide accurate diagnoses, image-guided biopsies should be considered the procedure of choice in the initial exploration of patients with mediastinal masses. In our experience, cutting needles gave higher quality samples and diagnostic rates. We recommend the use of cutting needles as the preferred procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To analyze surgical and pathological parameters and outcome and prognostic factors of patients with nonsmall cell lung cancer (NSCLC) who were admitted to a single institution, as well as to correlate these findings to the current staging system. METHOD: Seven hundred and thirty seven patients were diagnosed with NSCLC and admitted to Hospital do Cancer A. C. Camargo from 1990 to 2000. All patients were included in a continuous prospective database, and their data was analyzed. Following staging, a multidisciplinary team decision on adequate management was established. Variables included in this analysis were age, gender, histology, Karnofsky index, weight loss, clinical stage, surgical stage, chemotherapy, radiotherapy, and survival rates. RESULTS: 75.5% of patients were males. The distribution of histologic type was squamous cell carcinoma 51.8%, adenocarcinoma 43.1%, and undifferentiated large cell carcinoma 5.1%. Most patients (73%) presented significant weight loss and a Karnofsky index of 80%. Clinical staging was IA 3.8%, IB 9.2%, IIA 1.4%, IIB 8.1%, IIIA 20.9%, IIIB 22.4%, IV 30.9%. Complete tumor resection was performed in 24.6% of all patients. Surgical stage distribution was IA 25.3%, IB 1.4%, IIB 17.1%, IIIA 16.1%, IIIB 20.3%, IV 11.5%. Chemotherapy and radiotherapy were considered therapeutic options in 43% and 72%, respectively. The overall 5-year survival rate of nonsmall cell lung cancer patients in our study was 28%. Median survival was 18.9 months. CONCLUSIONS: Patients with NSCLC who were admitted to our institution presented with histopathologic and clinical characteristics that were similar to previously published series in cancer hospitals. The best prognosis was associated with complete tumor resection with lymph node dissection, which is only achievable in earlier clinical stages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polygyny, characterized by the presence of several egg-laying queens, is considered as a temporary colony status. In stingless bees it is rarely observed. This paper reports the first case of natural polygyny in Melipona scutellaris colony, with five egg-laying queens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Isoprene emission from plants accounts for about one third of annual global volatile organic compound emissions. The largest source of isoprene for the global atmosphere is the Amazon Basin. This study aimed to identify and quantify the isoprene emission and photosynthesis at different levels of light intensity and leaf temperature, in three phenological phases (young mature leaf, old mature leaf and senescent leaf) of Eschweilera coriacea (Matamatá verdadeira), the species with the widest distribution in the central Amazon. In situ photosynthesis and isoprene emission measurements showed that young mature leaf had the highest rates at all light intensities and leaf temperatures. Additionally, it was observed that isoprene emission capacity (Es) changed considerably over different leaf ages. This suggests that aging leads to a reduction of both leaf photosynthetic activity and isoprene production and emission. The algorithm of Guenther et al. (1999) provided good fits to the data when incident light was varied, however differences among E S of all leaf ages influenced on quantic yield predicted by model. When leaf temperature was varied, algorithm prediction was not satisfactory for temperature higher than ~40 °C; this could be because our data did not show isoprene temperature optimum up to 45 °C. Our results are consistent with the hypothesis of the isoprene functional role in protecting plants from high temperatures and highlight the need to include leaf phenology effects in isoprene emission models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the relation between coronary artery disease and the calcification index on helical computed tomography. METHOD: We studied 22 patients (ages ranging from 40 to 70 years) who underwent coronary angiography because of chest pain suggestive of angina pectoris. Findings on coronary angiography were classified as follows: significant obstructive disease (stenosis > or = 50%), nonobstructive disease (stenosis <50%), and no disease. With no previous knowledge of the results of the coronary angiography and within 7 days, helical computed tomography of the chest was performed. Then, data of the coronary angiography were correlated with the calcification index obtained by helical computed tomography. RESULTS: The sensitivity of helical computed tomography to the presence of significant obstructive lesions on coronary angiography was 87.5%, specificity was 100%, and negative and positive predictive values were 75% and 100%, respectively. The mean calcification index was greater in patients with severe coronary lesions, mainly when involvement of 2 or 3 vessels occurred, than that in patients with no coronary artery disease or with nonobstructive coronary artery lesions (p<0.05). CONCLUSION: Helical computed tomography is an effective method for detecting and quantifying coronary artery calcification, and it has proved to be sensitive to and specific for the noninvasive diagnosis of coronary artery stenosis.