39 resultados para Search-based technique


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The formal calibration procedure of a phase fraction meter is based on registering the outputs resulting from imposed phase fractions at known flow regimes. This can be straightforwardly done in laboratory conditions, but is rarely the case in industrial conditions, and particularly for on-site applications. Thus, there is a clear need for less restrictive calibration methods regarding to the prior knowledge of the complete set of inlet conditions. A new procedure is proposed in this work for the on-site construction of the calibration curve from total flown mass values of the homogeneous dispersed phase. The solution is obtained by minimizing a convenient error functional, assembled with data from redundant tests to handle the intrinsic ill-conditioned nature of the problem. Numerical simulations performed for increasing error levels demonstrate that acceptable calibration curves can be reconstructed, even from total mass measured within a precision of up to 2%. Consequently, the method can readily be applied, especially in on-site calibration problems in which classical procedures fail due to the impossibility of having a strict control of all the input/output parameters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to optimize and validate the solid-liquid extraction (ESL) technique for determination of picloram residues in soil samples. At the optimization stage, the optimal conditions for extraction of soil samples were determined using univariate analysis. Ratio soil/solution extraction, type and time of agitation, ionic strength and pH of extraction solution were evaluated. Based on the optimized parameters, the following method of extraction and analysis of picloram was developed: weigh 2.00 g of soil dried and sieved through a sieve mesh of 2.0 mm pore, add 20.0 mL of KCl concentration of 0.5 mol L-1, shake the bottle in the vortex for 10 seconds to form suspension and adjust to pH 7.00, with alkaline KOH 0.1 mol L-1. Homogenate the system in a shaker system for 60 minutes and then let it stand for 10 minutes. The bottles are centrifuged for 10 minutes at 3,500 rpm. After the settlement of the soil particles and cleaning of the supernatant extract, an aliquot is withdrawn and analyzed by high performance liquid chromatography. The optimized method was validated by determining the selectivity, linearity, detection and quantification limits, precision and accuracy. The ESL methodology was efficient for analysis of residues of the pesticides studied, with percentages of recovery above 90%. The limits of detection and quantification were 20.0 and 66.0 mg kg-1 soil for the PVA, and 40.0 and 132.0 mg kg-1 soil for the VLA. The coefficients of variation (CV) were equal to 2.32 and 2.69 for PVA and TH soils, respectively. The methodology resulted in low organic solvent consumption and cleaner extracts, as well as no purification steps for chromatographic analysis were required. The parameters evaluated in the validation process indicated that the ESL methodology is efficient for the extraction of picloram residues in soils, with low limits of detection and quantification.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to identify restriction fragment length polymorphism (RFLP) markers linked to QTLs that control aluminum (Al) tolerance in maize. The strategy used was bulked segregant analysis (BSA) and the genetic material utilized was an F2 population derived from a cross between the Al-susceptible inbred line L53 and Al-tolerant inbred line L1327. Both lines were developed at the National Maize and Sorghum Research Center - CNPMS/EMBRAPA. The F2 population of 1554 individuals was evaluated in a nutrient solution containing a toxic concentration of Al and relative seminal root length (RSRL) was used as a phenotypic measure of tolerance. The RSRL frequency distribution was continuous, but skewed towards Al-susceptible individuals. Seedlings of the F2 population which scored the highest and the lowest RSRL values were transplanted to the field and subsequently selfed to obtain F3 families. Thirty F3 families (15 Al-susceptible and 15 Al-tolerant) were evaluated in nutrient solution, using an incomplete block design, to identify those with the smallest variances for aluminum tolerance and susceptibility. Six Al-susceptible and five Al-tolerant F3 families were chosen to construct one pool of Al-susceptible individuals, and another of Al-tolerant, herein referred as "bulks", based on average values of RSRL and genetic variance. One hundred and thirteen probes were selected, with an average interval of 30 cM, covering the 10 maize chromosomes. These were tested for their ability to discriminate the parental lines. Fifty-four of these probes were polymorphic, with 46 showing codominance. These probes were hybridized with DNA from the two contrasting bulks. Three RFLPs on chromosome 8 distinguished the bulks on the basis of band intensity. DNA of individuals from the bulks was hybridized with these probes and showed the presence of heterozygous individuals in each bulk. These results suggest that in maize there is a region related to aluminum tolerance on chromosome 8

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Genotyping techniques are valuable tools for the epidemiologic study of Staphylococcus aureus infections in the hospital setting. Pulsed-field gel electrophoresis (PFGE) is the current method of choice for S. aureus strain typing. However, the method is laborious and requires expensive equipment. In the present study, we evaluated the natural polymorphism of the genomic 16S-23S rRNA region for genotyping purpose, by PCR-based ribotyping. Three primer pairs were tested to determine the size of amplicons produced and to obtain better discrimination with agar gel electrophoresis and ethidium bromide staining. The resolution of the typing system was determined using sets of bacteria obtained from clinical specimens from a large tertiary care hospital. These included DNA from three samples obtained from a bacteremic patient, six strains with known and diverse PGFE patterns, and 88 strains collected over a 3-month period in the same hospital. Amplification patterns obtained from samples from the same patient were identical, and PFGE from samples known to be different produced three genotypes. Amplification of DNA from 61 methicillin-resistant isolates produced only one pattern. Methicillin-sensitive strains yielded a diversity of patterns, pointing to a true polyclonal distribution throughout the hospital (22 unique patterns from 27 strains). Computer-based software can be used to differentiate among identifiable strains, given the low number of bands and good characterization of PCR products. PCR-based ribotyping can be a useful technique for genotyping methicillin-sensitive S. aureus strains, but is of limited value for methicillin-resistant strains.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coronary artery disease (CAD) is a worldwide leading cause of death. The standard method for evaluating critical partial occlusions is coronary arteriography, a catheterization technique which is invasive, time consuming, and costly. There are noninvasive approaches for the early detection of CAD. The basis for the noninvasive diagnosis of CAD has been laid in a sequential analysis of the risk factors, and the results of the treadmill test and myocardial perfusion scintigraphy (MPS). Many investigators have demonstrated that the diagnostic applications of MPS are appropriate for patients who have an intermediate likelihood of disease. Although this information is useful, it is only partially utilized in clinical practice due to the difficulty to properly classify the patients. Since the seminal work of Lotfi Zadeh, fuzzy logic has been applied in numerous areas. In the present study, we proposed and tested a model to select patients for MPS based on fuzzy sets theory. A group of 1053 patients was used to develop the model and another group of 1045 patients was used to test it. Receiver operating characteristic curves were used to compare the performance of the fuzzy model against expert physician opinions, and showed that the performance of the fuzzy model was equal or superior to that of the physicians. Therefore, we conclude that the fuzzy model could be a useful tool to assist the general practitioner in the selection of patients for MPS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since there are some concerns about the effectiveness of highly active antiretroviral therapy in developing countries, we compared the initial combination antiretroviral therapy with zidovudine and lamivudine plus either nelfinavir or efavirenz at a university-based outpatient service in Brazil. This was a retrospective comparative cohort study carried out in a tertiary level hospital. A total of 194 patients receiving either nelfinavir or efavirenz were identified through our electronic database search, but only 126 patients met the inclusion criteria. Patients were included if they were older than 18 years old, naive for antiretroviral therapy, and had at least 1 follow-up visit after starting the antiretroviral regimen. Fifty-one of the included patients were receiving a nelfinavir-based regimen and 75 an efavirenz-based regimen as outpatients. Antiretroviral therapy was prescribed to all patients according to current guidelines. By intention-to-treat (missing/switch = failure), after a 12-month period, 65% of the patients in the efavirenz group reached a viral load <400 copies/mL compared to 41% of the patients in the nelfinavir group (P = 0.01). The mean CD4 cell count increase after a 12-month period was also greater in the efavirenz group (195 x 10(6) cells/L) than in the nelfinavir group (119 x 10(6) cells/L; P = 0.002). The efavirenz-based regimen was superior compared to the nelfinavir-based regimen. The low response rate in the nelfinavir group might be partially explained by the difficulty of using a regimen requiring a higher patient compliance (12 vs 3 pills a day) in a developing country.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mimic biological structures such as the cell wall of plant tissues may be an alternative to obtain biodegradable films with improved mechanical and water vapor barrier properties. This study aims to evaluate the mechanical properties and water vapor permeability (WVP) of films produced by using the solvent-casting technique from blended methylcellulose, glucomannan, pectin and gelatin. First, films from polysaccharides at pH 4 were produced. The film with the best mechanical performance (tensile strength = 72.63 MPa; elongation = 9.85%) was obtained from methylcellulose-glucomannan-pectin at ratio 1:4:1, respectively. Then, gelatin was added to this polysaccharide blend and the pH was adjusted to 4, 5 and 6. Results showed significant improvement in WVP when films were made at pH 5 and at polysaccharides/gelatin ratio of 90/10 and 10/90, reaching 0.094 and 0.118 g.mm/h.m².kPa as values, respectively. Films with the best mechanical properties were obtained from the blend of polysaccharides, whereas WVP was improved from the blend of polysaccharides and gelatin at pH 5.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Salted lamb meat blanket, originated from boning, salting, and drying of whole lamb carcass, was studied aiming at obtaining information that support the search for guarantees of origin for this typical regional product from the city of Petrolina-Pernambuco-Brazil. Data from three processing units were obtained, where it was observed the use of a traditional local technology that uses salting, an ancient preservation method; however, with a peculiar boning technique, resulting in a meat product with great potential for exploitation in the form of meat blanket. Based on the values of pH (6.22 ± 0.22), water activity (0.97 ± 0.02), and moisture (69.86 ± 2.26) lamb meat blanket is considered a perishable product, and consequently it requires the use of other preservation methods combined with salt, which along with the results of the microbiological analyses (absence of Salmonella sp, score <10 MPN/g of halophilic bacteria, total coliforms between 6.7 × 10³ and 5.2 × 10(6) FUC/g, and Staphylococcus from 8.1 × 10³ CFU/g at uncountable) reinforce the need of hygienic practices to ensure product safety. These results, together with the product notoriety and the organization of the sector are important factors in achieving Geographical Indication of the Salted lamb Meat blanket of Petrolina.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Brazilian wine production is characterized by Vitis labrusca grape varieties, especially the economically important Isabel cultivar, with over 80% of its production destined for table wine production. The objective of this study was to optimize and validate the conditions for extracting volatile compounds from wine with the solid-phase microextraction technique, using the response surface method. Based on the response surface analysis, it can be concluded that the central point values maximize the process of extracting volatile compounds from wine, i.e., an equilibrium time of 15 minutes, an extraction time of 35 minutes, and an extraction temperature of 30 °C. Esters were the most numerous compounds found under these extraction conditions, indicating that wines made from Isabel cultivar grapes are characterized by compounds that confer a fruity aroma; this finding corroborates the scientific literature.