38 resultados para Photothermal spectroscopy of liquids
Resumo:
Doripenem was characterized through physicochemical and spectroscopic techniques, as well as thermal analysis. TLC (Rf = 0.62) and HPLC (rt = 7.4 min) were found to be adequate to identify the drug. UV and infrared spectra showed similar profile between doripenem bulk and standard. The ¹H and 13C NMR analysis revealed chemical shifts that allowed identifying the drug. Thermal analysis demonstrated three steps with mass loss, at 128, 178 and 276 ºC. The work was successfully applied to qualitative analysis of doripenem, showing the reported methods can be used for physicochemical characterization of doripenem
Resumo:
We propose an analytical method based on fourier transform infrared-attenuated total reflectance (FTIR-ATR) spectroscopy to detect the adulteration of petrodiesel and petrodiesel/palm biodiesel blends with African crude palm oil. The infrared spectral fingerprints from the sample analysis were used to perform principal components analysis (PCA) and to construct a prediction model using partial least squares (PLS) regression. The PCA results separated the samples into three groups, allowing identification of those subjected to adulteration with palm oil. The obtained model shows a good predictive capacity for determining the concentration of palm oil in petrodiesel/biodiesel blends. Advantages of the proposed method include cost-effectiveness and speed; it is also environmentally friendly.
Resumo:
This work shows the application of ¹H NMR spectroscopy and chemometrics for quality control of grape juice. A wide range of quality assurance parameters were assessed by single ¹H NMR experiments acquired directly from juice. The investigation revealed that conditions and time of storage should be revised and indicated on all labels. The sterilization process of homemade grape juices was efficient, making it possible to store them for long periods without additives. Furthermore, chemometric analysis classified the best commercial grape juices to be similar to homemade grape juices, indicating that this approach can be used to determine the authenticity after adulteration.
Resumo:
This paper describes a method for quantitative spot test analysis of hydrochlorothiazide using diffuse reflectance spectroscopy. The reflectance measurements were performed analyzing the colored compound (l = 585 nm) produced from the reaction between hydrochlorothiazide and p-dimethylaminocinnamaldehyde (PDAC) in acid medium. This reaction occurred on filter paper after heating to 80ºC for 8 minutes. Factorial designs allowed varying multiple reaction factors simultaneously in order to obtain the best reaction conditions. These factors included heating temperature, heating time, acid volume and PDAC volume. The linearity was studied in the range of 3.36x10-2 to 1.01x10-1 mol L-1 with a correlation coefficient of 0.998. The limit of detection was estimated to be 1.32x10² mol L-1. Commercial samples were analyzed using the proposed method and the results were favorably compared with those of the United States Pharmacopeia method, showing that quantitative spot test analysis by diffuse reflectance could be successfully used to determine hydrochlorothiazide in medicines.
Resumo:
A simple analytical method for quantification of atenolol in pharmaceutical formulations by diffuse reflectance spectroscopy is described. The method is based on the reaction, on the filter paper surface, between the drug and p-chloranil producing a colored compound. The best reaction conditions were obtained with 20 µL of atenolol solution and 20 µL of p-chloranil. All reflectance measurements were carried out at 550 nm and the linear range was from 1.13x10-2 to 7.88x10-2 mol L-1 (r = 0.9992). The limit of detection was 2.80 x 10-3 mol L-1. The proposed method was successfully applied to analysis of different commercial brands of pharmaceutical formulations and the results obtained by the proposed method were in good agreement with those obtained using the British Pharmacopoeia method.
Resumo:
The physical characteristics of a spray liquid are important in getting a good droplet formation and control efficiency over a particular target. As a function of these characteristics, it is possible to decipher which is the best adjuvant based on the respective concentration used during the spray. Therefore, ten spraying liquids were prepared, which varied in concentrations of pesticide lufenuron + profenofos, mineral oil, water and manganese sulfate. Pendant droplets formed from these mixtures were measured to examine their impact on surface tension. Droplets were applied to the surface of coffee leaves and the surface tension, contact angle formed and the leaf area wetted by the droplet, were measured. A smooth glass surface was taken as a comparative to the coffee leaves. The highest concentrations of oil resulted in lower surface tension, smaller contact angles of droplets on leaf surfaces and larger areas wetted by the droplets. Both surfaces showed hydrophilic behavior.
Resumo:
The widespread use of ³H and 14C in research has generated a large volume of waste mixed with scintillation liquid, requiring an effective control and appropriate storage of liquid radioactive waste. In the present study, we compared the efficacy of three commercially available scintillation liquids, Optiphase HiSafe 3, Ultima-Gold™ AB (biodegradable) and Insta-Gel-XF (non-biodegradable), in terms of [14C]-glucose and [³H]-thymidine counting efficiency. We also analyzed the effect of the relative amount of water (1.6 to 50%), radioisotope concentration (0.1 to 100 nCi/ml), pH (2 to 10) and color of the solutions (samples containing 0.1 to 1.0 mg/ml of Trypan blue) on the counting efficiency in the presence of these scintillation liquids. There were few significant differences in the efficiency of 14C and ³H counting obtained with biodegradable or non-biodegradable scintillation liquids. However, there was an 83 and 94% reduction in the efficiency of 14C and ³H counting, respectively, in samples colored with 1 mg/ml Trypan blue, but not with 0.1 mg/ml, independent of the scintillation liquid used. Considering the low cost of biodegradable scintillation cocktails and their efficacy, these results show that traditional hazardous scintillation fluids may be replaced with the new safe biodegradable fluids without impairment of ³H and 14C counting efficiency. The use of biodegradable scintillation cocktails minimizes both human and environmental exposure to hazardous solvents. In addition, some biodegradable scintillation liquids can be 40% less expensive than the traditional hazardous cocktails.
Resumo:
The assessment of fluid volume in neonates by a noninvasive, inexpensive, and fast method can contribute significantly to increase the quality of neonatal care. The objective of the present study was to calibrate an acquisition system and software to estimate the bioelectrical impedance parameters obtained by a method of bioelectrical impedance spectroscopy based on step response and to develop specific equations for the neonatal population to determine body fluid compartments. Bioelectric impedance measurements were performed by a laboratory homemade instrument. The volumes were estimated in a clinical study on 30 full-term neonates at four different times during the first month of life. During the first 24 hours of life the total body water, extracellular water and intracellular water were 2.09 ± 0.25, 1.20 ± 0.19, and 0.90 ± 0.25 liters, respectively. By the 48th hour they were 1.87 ± 0.27, 1.08 ± 0.17, and 0.79 ± 0.21 liters, respectively. On the 10th day they were 2.02 ± 0.25, 1.29 ± 0.21, and 0.72 ± 0.14 liters, respectively, and after 1 month they were 2.34 ± 0.27, 1.62 ± 0.20, and 0.72 ± 0.13 liters, respectively. The behavior of the estimated volume was correlated with neonatal body weight changes, leading to a better interpretation of such changes. In conclusion, this study indicates the feasibility of bioelectrical impedance spectroscopy as a method to help fluid administration in intensive care neonatal units, and also contribute to the development of new equations to estimate neonatal body fluid contents.