76 resultados para Age, lower confidence level


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow injection spectrophotometric procedure is proposed for the determination of paracetamol (acetaminophen) in pharmaceutical formulations. Powdered and liquid samples were previously dissolved/diluted in 0.05 mol L-1 hydrochloric acid solution and a volume of 250 µL was injected directly into a carrier stream of this same acid solution, flowing at 2.5 mL min-1. Paracetamol reacts with sodium hypochlorite forming N-acetyl-p-benzoquinoneimine which then reacts with sodium salicylate in sodium hydroxide solution yielding a blue indophenol dye which was measured at 640 nm in the pH range of 9.5-10.0. Paracetamol was determined in pharmaceutical products in the 1.0 to 100.0 mg L-1 (3.3x10-6 a 6.6x10-4 mol L-1) concentration range, with a detection limit of 0.5 mg L-1 (1.6x10-6 mol L-1). The recovery of this analyte in five samples ranged from 98.0 to 103.6 %. The analytical frequency was 80 determinations per hour and the RSDs were less than 1% for paracetamol concentrations of 25.0, 50.0 and 75.0 mg L-1 (n=10). A paired t-test showed that all results obtained for paracetamol in commercial formulations using the proposed flow injection procedure and a spectrophotometric batch procedure agree at the 95% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow injection spectrophotometric procedure was developed for the determination of metamizol in pharmaceutical formulations. The system is based on the reaction between metamizol and triiodide generated in the system by mixing iodate and iodide-starch solutions. The absorbance of triiodide-starch complex giving a steady-state baseline value which was monitored at 580 nm. The inverse peaks caused by metamizol samples were measured and there was a direct relationship between absorbance decreasing and metamizol concentration from 1.4 x 10-4 to 7.0 x 10-4 mol L-1. The RSD was 0.45 % for a metamizol solution 4.2 x 10-4 mol L-1 (n = 10) with a detection limit (three-fold blank standard deviation/slope) of 6.0 x 10-5 mol L-1 The feasibility of the system was demonstrated for the determination of metamizol in commercial samples with sixty results obtained per hour. The results obtained for metamizol in pharmaceutical formulations using the proposed flow procedure and those obtained using an iodimetric procedure are in agreement at the 95% confidence level and within an acceptable range of error.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The goal of this study was to evaluate the feasibility of direct introduction of clay slurries in an inductively coupled plasma optical emission spectrometer with axial view configuration. Calibration was performed using a certified reference material with a mean particle size of 13 µm (IPT-42) and the analytical curve was applied for quantification of two others reference materials (IPT-28 and IPT-32) and four samples. It was demonstrated that the analytical curve thus obtained was not completely suitable for IPT-28 and samples due to different mineralogical phases determined by X-ray diffraction. After considering this effect, it was possible for most elements to obtain results in agreement with certified values or with values obtained by a conventional technique at a 95% confidence level. It was demonstrated that the ICP-OES with axial view configuration did not present any incompatibility with the direct introduction of a complex inorganic suspension.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Crude extracts of several vegetables such as peach (Prunus persica), yam (Alocasia macrorhiza), manioc (Manihot utilissima), artichoke (Cynara scolymus L), sweet potato (Ipomoea batatas (L.) Lam.), turnip (Brassica campestre ssp. rapifera), horseradish (Armoracia rusticana) and zucchini (Cucurbita pepo) were investigated as the source of peroxidase (POD: EC 1.11.1.7). Among those, zucchini (Cucurbita pepo) crude extract was found to be the best one. This enzyme in the presence of hydrogen peroxide catalyses the oxidation of paracetamol to N-acetyl-p-benzoquinoneimine which the electrochemical reduction back to paracetamol was obtained at a peak potential of ¾0.10V. A cyclic voltammetric study was performed by scanning the potential from + 0.5 to ¾ 0.5 V. The recovery of paracetamol from two samples ranged from 97.3 to 106% and a rectilinear calibration curve for paracetamol concentration from 1.2x10-4 to 2.5x10-3 mol L-1 (r=0.9965) were obtained. The detection limit was 6.9x10-5 mol L-1 and the relative standard deviation was less than 1.1% for a solution containing 2.5x10-3 mol L-1 paracetamol and 2.0x10-3 mol L-1 hydrogen peroxide (n=12). The results obtained for paracetamol in pharmaceutical products using the proposed biosensor and Pharmacopoeial procedures are in agreement at the 95% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work two procedures were proposed for analytical curves construction using a single standard solution employing a flow injection system with solid phase spectrophotometric detection (FI-SPS). A flow cell contends the chromogenic reagent 1-(2-tiazolylazo)-2-naphtol was positioned on the optical path. The first procedure was based on controlled concentration of analyte on solid phase and the relations between absorbance and the total volume of injected allowed the calculation of analyte concentration. The second procedure was developed employing controlled dispersion/retention in flow system where analyte concentration was obtained by exploiting the relation between transient signals of samples and single standard solution at equivalent reading time. The procedures were successfully applied for zinc determination in synthetic solutions with good precision and accuracy at 95% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work a micro-heater device to be used as an integral part of the flow analysis manifold is described. The usefulness of the device was demonstrated using it in the development of a multicommutated flow analysis procedure for the spectrophotometric determination of manganese in plant digest. The method was based on the manganese oxidation by periodate in phosphoric acid medium to form the permanganate anion. The reaction development is dependent on the temperature and it was observed that at 25 °C a time interval of ca. 15 min was necessary for the reaction to attain equilibrium. Setting the temperature to 70 ºC, this time interval could be decreased to ca. 30 s. This condition was easily attained employing the proposed micro-heater device coupled to the manifold. The procedure was applied to manganese determination in soybean digests and results compared with those obtained by inductively coupled argon plasma optical emission spectrometry (ICP-OES). No significant difference at 90% confidence level was observed. A linear response for sample concentrations ranging from 5.0 to 30.00 mg L-1 Mn2+; a relative standard deviation of 1.3% (n = 6) for a typical sample containing 6.3 mg L-1 Mn2+; a sampling rate of 22 determinations per hour; a low reagent consumption, of 12.0 mg NaIO4 per determination; and a detection limit of 1.2 mg L-1 were achieved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work a closed-vessel microwave-assisted acid decomposition procedure for clays was developed. Aluminum, Ca, Fe, K, Mg, Na, Si, and Ti were determined in clay digestates by inductively coupled plasma optical emission spectrometry. The most critical parameter for total decomposition of clays was the composition of the reagent mixture. The applied power and the heating time exerted a less critical influence. Best decomposition conditions were attained using a reagent mixture containing 4 mL aqua regia plus 3 mL HF and the heating program was implemented in 12 min. The accuracy of the results was demonstrated using two standard reference materials and a paired t-test showed a good agreement between determined and certified values at a 95% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The applicability of the recently proposed procedure based on gradual sample addition to microwave-assisted pre-heated concentrated acid is limited by the sample viscosity. In this work, lubricating oil samples with high viscosity were encapsulated and manually added to the microwave-assisted pre-heated concentrated digestion mixture. The procedure was applied for determination of Al, Ca, Cr, Cu, Fe, Mg, Ni, P, Pb, Si, Sn, Sr, V, W, and Zn in lubricating oil by inductively coupled plasma optical emission spectrometry (ICP OES). Determined and certified values for Ca, Mg, P, and Zn in lubricating oil were in agreement at a 95% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new titrimetric method for the determination of phosphite in fertilizer samples, based on reaction of H3PO3 with standard iodine solution in neutral media, is proposed. Diluted samples containing ca. 0.4% m/v P2O5 are heated and titrated with 0.05 mol L-1 iodine standard until the solution becomes faint yellow. Back titration is also feasible: a slight excess of titrant is added followed by starch indicator and titration is completed taking as the end point the change in color from blue to colorless. The influence of chemical composition and pH of buffers, temperature and foreign species on waiting time and end-point detection were investigated. For the Na2HPO4/NaH2PO4 buffer (pH 6.8) at 70 °C, the titration time was 10 min, corresponding to about 127 mg iodine, 200 mg KI and 174 mg Na2HPO4 and 176 mg NaH2PO4 consumed per determination. Accuracy was checked for phosphite determination in seven fertilizer samples. Results obtained by the proposed procedure were in agreement with those obtained by spectrophotometry at 95% confidence level. The R.S.D. (n=10) for direct and back titration was 0.4% and 1.3% respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work was developed a method for the determination of saccharin in dietary products by a biamperometric titration, using two silver electrodes as working electrodes and silver nitrate as titrant. It were used products as juices (light) and sweeteners with saccharin in concentrations ranged from 8.73 x 10-5 mol L-1 to 1.0 x 10-2 mol L-1, and the results were in close agreement with those data found using a HPLC method at a confidence level of 95%. The main advantages of the proposed method are its simplicity, rapid and low cost.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes methods for the simultaneous determination of Cd and Pb by graphite furnace atomic absorption spectrometry and As by hydride generation atomic absorption spectrometry in Brazilian nuts. The samples (~ 0.300 g) were digested to clear solutions in a closed vessel microwave oven. The pyrolysis and atomization temperatures for simultaneous determinations of Cd and Pb were 1100 and 2100 °C, respectively, using 0.5% (w v-1) NH4H2PO4 + 0.03% (w v-1) Mg(NO3)2 as chemical modifier. The limits of detection (3Δ) were 3.8 μg kg-1 for As, 0.86 μg kg-1 for Cd and 13 μg kg-1 for Pb. The reliability of the entire procedures was confirmed by peach leaves (No. 1547 - NIST) certified reference material analysis and addition and recovery tests. The found concentrations presented no statistical differences at the 95% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports an analytical method for the determination of ambroxol in micellar medium by spot test-diffuse reflectance spectroscopy. The reflectance measurements were performed analyzing the colored compound (λ= 520 nm) produced from the reaction between ambroxol and p-dimethylaminocinnamaldehyde on the surface filter paper. The linear range was from 1.21 × 10"3 to 9.65 × 10"3 mol L-1 (500 - 4000 μg mL-1). The limit of detection and quantification were 3.50 x 10-4 mol L-1 (145 μg mL-1) and 1.16 x 10-3 mol L-1 (481 μg mL-1), respectively. Five commercial samples were analysed and the results obtained by the proposed method were in good agreement with those obtained by the literature method at 95% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow-injection (FI) spectrophotometric procedure is proposed for tetracycline (TC) and doxycycline (DXC) determination in pharmaceuticals. The method is based on the reaction of oxidation of these drugs by chloramine-T in alkaline medium producing red color products (λmax = 535 and 525 nm). Beer´s law is obeyed in the concentration range from 6.62 x 10-5 to 7.72 x 10-4 mol L-1 and 5.37 x 10-5 to 7.16 x 10-4 mol L-1 for TC and DXC, respectively. The analytical frequency was 50 h"1 and 45 h-1 for TC and DXC, respectively. The results obtained by the proposed method were in good agreement with those obtained by the official method at 95% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, precise, rapid and low-cost conductometric titration method for the determination of metformin hydrochloride (MET) in pharmaceuticals using silver nitrate as titrant is proposed. The method was based on the chemical reaction between the chloride of metformin hydrochloride molecule and Ag(I) ions, yielding the precipitate AgCl(s). The method was applied for MET determination in three pharmaceuticals and the obtained results with proposed method were in close agreement with those results obtained using an official method of the British Pharmacopoeia, at a 95% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work proposes an analytical procedure for direct determination of calcium, magnesium, manganese and zinc in buffalo milk by flame atomic absorption spectrometry (FAAS). Samples were diluted with a solution containing 10% (v/v) of water-soluble tertiary amines (CFA-C) at pH 8. For comparison, buffalo milk samples were digested with HNO3 and H2O2. According to a paired t-test, the results obtained in the determination of Ca, Mg, Mn and Zn in digested samples and in 10% (v/v) CFA-C medium were in agreement at a 95% confidence level. The developed procedure is simple, rapid, decrease the possibility of contamination and can be applied for the routine determination of Ca, Mg, Mn and Zn in buffalo milk samples without any difficulty caused by matrix constituents, such as fat content, and particle size distribution in the milk emulsion.