43 resultados para 3D Stripixel Detector
Resumo:
The analysis of fatty acid (FA) esters by gas chromatography and flame ionization detector (FID) normally uses the normalization method. However, if one FA is wrongly estimated, the results could be greatly affected. In this study, methodologies using internal standards and correction factors for the FID response are described. The results show that by using theoretical correction factors associated to the internal standardization, the quantitative analyses of the FAs are expressed in mass, increasing the accuracy and facilitating the interpretation and comparison of the results for foods and biodiesels.
Resumo:
A simple and fast method for determination of 40 basic drugs in human plasma employing gas-chromatography with nitrogen-phosphorus detection was developed and validated. Drugs were extracted from 800 µL of plasma with 250 µL of butyl acetate at basic pH. Aliquots of the organic extract were directly injected on a column with methylsilicone stationary phase. Total chromatographic run time was 25 min. All compounds were detected in concentrations ranging from therapeutic to toxic levels, with intermediate precision CV% below 11.2 and accuracy in the range of 92-114%.
Resumo:
A high performance liquid chromatographic-diode array detection method for the determination of busulfan in plasma was developed and validated. Sample preparation consisted of protein precipitation followed by derivatization with sodium diethyldithiocarbamate and liquid-liquid extraction with methyl-tert-butyl ether. Chromatograms were monitored at 277 nm. Separation was carried out on a Lichrospher RP 18 column (5 µm, 250 x 4 mm). The mobile phase consisted of water and acetonitrile (20:80, v/v). The method presented adequate specificity, linearity, precision and accuracy and allowed reliable determination of busulfan in clinical plasma samples, being applied to three patients submitted to bone marrow transplantation.
Resumo:
This paper regards the implementation of the QuEChERS method for the analysis by GC-FPD of 53 different pesticides from the organophosphate class, in whole UHT and pasteurized milk. Selectivity, linearity, repeatability, recovery and limits of detection and quantification were evaluated. Of all pesticide recoveries, 51 were considered satisfactory since the values ranged from 70 to 120% with RSD < 20%. The quantification limits ranged from 0.005 to 0.4 mg kg-1. The QuEChERS method was suitable for determination of 52 pesticides, presenting several advantages - quick, cheap, easy, effective, rugged and safe - with regard to other traditional methodologies.
Resumo:
Imide compounds have shown biological activity. These compounds can be easily synthesized with good yields. The objective of this paper was the rational planning of imides and sulfonamides with antinociceptive activity using the 3D-QSAR/CoMFA approach. The studies were performed using two data sets. The first set consisted of 39 cyclic imides while the second set consisted of 39 imides and 15 sulfonamides. The 3D- QSAR/CoMFA models have shown that the steric effect is important for the antinociceptive activity of imide and sulphonamide compounds. Ten new compounds with improved potential antinociceptive activity have been proposed by de novo design leapfrog simulations.
Resumo:
Topiramate and the other frequently co-administered antiepileptic drugs carbamazepine, phenytoin and phenobarbital were determined in 100 µL plasma samples by gas chromatography with nitrogen phosphorus detection (GC-NPD), after a one-step liquid-liquid extraction with ethyl acetate, followed by flash methylation with trimethylphenylammonium hydroxide. Total chromatographic run time was 12.5 min. Intra-assay and inter-assay precision was 2.5-7.3% and 1.6-5.2%, respectively. Accuracy was 100.1-104.2%. The limit of quantitation was 1 µg mL-1 for all analytes, proving suitable for routine application in therapeutic drug monitoring of antiepileptic drugs.
Resumo:
Um método simples e eficiente para determinação simultânea de quatro ácidos carboxílicos de cadeia curta (acético, propiônico, butírico e valérico) em resíduos sólidos urbanos (RSU) é descrito no presente trabalho. Estes ácidos são considerados fitotóxicos na literatura e a variabilidade das suas concentrações durante o processo pode ser usada como parâmetro da maturação do composto de resíduos sólidos urbanos (RSU). A determinação dos ácidos carboxílicos presentes no composto de RSU envolve uma extração em água e filtração em membranas de polifluoreto de vinilideno (PVDF), seguida da injeção direta em um cromatográfo a gás com detector por ionização em chama (CG-DIC). Foram analisados três tipos de leira. Boas linearidades e coeficientes de correlação foram obtidas para todos os ácidos, e os limites de detecção e quantificação foram baixos, resultando em um método sensível para monitoramento desses ácidos em composto de RSU.
Resumo:
A novel heteronuclear 3d-4f compound having formula NdCu3L3·13H2O (where H3L = Schiff base derived from 5-bromosalicylaldehyde and glycylglycine and L³ = C11H8 N2O4Br) was obtained. It was characterized by elemental and thermal analyses and magnetic measurements. The Cu(II)-Nd(III) compound is stable up to 323 K. During dehydration process the water molecules are lost in two stages. The magnetic susceptibility data for this complex change with temperature according to the Curie-Weiss law with theta = -35 K. The magnetic moment values decrease from 5.00µB at 303 K to 4.38µB at 76 K.
Resumo:
A técnica de CLAE com detecção UV-Vis foi empregada na análise do teor de cocaína em amostras apreendidas de cocaína e crack. Uma fase móvel de acetonitrila/água (95:5v/v) possibilitou um sinal de pico para a cocaína em 3,5 minutos. O sinal espectrofotométrico otimizado foi obtido em um comprimento de onda de 224 nm. A curva analítica de 1,0 a 40,0 ppm para cocaína foi obtida, exibindo um coeficiente de correlação linear de 0,9989, com limites de detecção e quantificação de 0,75 e 3,78 ppm, respectivamente. Esta metodologia foi aplicada na dosagem de amostras confiscadas de cocaína e crack no Laboratório de Polícia Científica de Ribeirão Preto-SP.
Resumo:
By coupling the Boundary Element Method (BEM) and the Finite Element Method (FEM) an algorithm that combines the advantages of both numerical processes is developed. The main aim of the work concerns the time domain analysis of general three-dimensional wave propagation problems in elastic media. In addition, mathematical and numerical aspects of the related BE-, FE- and BE/FE-formulations are discussed. The coupling algorithm allows investigations of elastodynamic problems with a BE- and a FE-subdomain. In order to observe the performance of the coupling algorithm two problems are solved and their results compared to other numerical solutions.
Resumo:
A non isotropic turbulence model is extended and applied to three dimensional stably stratified flows and dispersion calculations. The model is derived from the algebraic stress model (including wall proximity effects), but it retains the simplicity of the "eddy viscosity" concept of first order models. The "modified k-epsilon" is implemented in a three dimensional numerical code. Once the flow is resolved, the predicted velocity and turbulence fields are interpolated into a second grid and used to solve the concentration equation. To evaluate the model, various steady state numerical solutions are compared with small scale dispersion experiments which were conducted at the wind tunnel of Mitsubishi Heavy Industries, in Japan. Stably stratified flows and plume dispersion over three distinct idealized complex topographies (flat and hilly terrain) are studied. Vertical profiles of velocity and pollutant concentration are shown and discussed. Also, comparisons are made against the results obtained with the standard k-epsilon model.
Resumo:
The Shadow Moiré fringe patterns are level lines of equal depth generated by interference between a master grid and its shadow projected on the surface. In simplistic approach, the minimum error is about the order of the master grid pitch, that is, always larger than 0,1 mm, resulting in an experimental technique of low precision. The use of a phase shift increases the accuracy of the Shadow Moiré technique. The current work uses the phase shifting method to determine the surfaces three-dimensional shape using isothamic fringe patterns and digital image processing. The current study presents the method and applies it to images obtained by simulation for error evaluation, as well as to a buckled plate, obtaining excellent results. The method hands itself particularly useful to decrease the errors in the interpretation of the Moiré fringes that can adversely affect the calculations of displacements in pieces containing many concave and convex regions in relatively small areas.
Resumo:
This work presents the implementation and comparison of three different techniques of three-dimensional computer vision as follows: • Stereo vision - correlation between two 2D images • Sensorial fusion - use of different sensors: camera 2D + ultrasound sensor (1D); • Structured light The computer vision techniques herein presented took into consideration the following characteristics: • Computational effort ( elapsed time for obtain the 3D information); • Influence of environmental conditions (noise due to a non uniform lighting, overlighting and shades); • The cost of the infrastructure for each technique; • Analysis of uncertainties, precision and accuracy. The option of using the Matlab software, version 5.1, for algorithm implementation of the three techniques was due to the simplicity of their commands, programming and debugging. Besides, this software is well known and used by the academic community, allowing the results of this work to be obtained and verified. Examples of three-dimensional vision applied to robotic assembling tasks ("pick-and-place") are presented.