436 resultados para Climatologia - Métodos de simulação


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chromatographic methods are commonly used for analysis of small molecules in different biological matrices. An important step to be considered upon a bioanalytical method's development is the capacity to yield reliable and reproducible results. This review discusses validation procedures adopted by different governmental agencies, such as Food and Drug Administration (USA), European Union (EU) and Agência Nacional de Vigilância Sanitária (BR) for quantification of small molecules by bioanalytical chromatographic methods. The main parameters addressed in this review are: selectivity, linearity, precision, accuracy, quantification and detection limits, recovery, dilution integrity, stability and robustness. Also, the acceptance criterions are clearly specified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analysis at microenvironments, like single cells or in minute volumes (nL), is an area of great interest for analytical and biological sciences. Measurements at these experimental conditions demand analytical tools (microelectrodes) capable of monitoring with rapid response, good resolution and minimal perturbation of the system. The major drawbacks in producing these microscopic electrodes have been largely overcome, principally due to the development of new fabrication methods. In this review, these procedures are described with emphasis to those devoted to the construction of microelectrodes for application in microenvironments. Examples of our efforts to use these devices as effective electrochemical sensors are also addressed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes an experiment designed to teach quantitative determination in gas chromatography (GC) in Organic and Analytical Chemistry practical classes. The experiment consisted of extracting and analyzing eugenol from clove seeds to perform a quantitative approach aimed at comparing results obtained by external and internal calibration procedures. Therefore, this experiment proved to be very effective tool to enhance students awareness on the need to understand different types of calibration in GC and on how to avoid common experimental errors, and to find the best ways to eliminate their interference during the quantitative analysis phase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The establishment of quality standards for biodiesel was a key step to win the confidence of the market and the automotive industry, thus ensuring the success of the new fuel. In this review are presented standard methods and other analytical methods suggested for analysis of biodiesel. The methods of analysis were divided into groups according to information that may be provided on the contaminants from the raw material of the production process, the molecular structures of biodiesel and its degradation during storage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review attempts to provide an updated overview of the Quick, Easy, Cheap, Effective, Ruged and Safe (QuEChERS) multiresidue extraction method, that involves initial extraction in acetonitrile, an extraction/partition step after the addition of salt, and a cleanup step utilizing dispersive solid phase extraction. QuEChERS method is nowadays the most applied extraction method for the determination of pesticide residues in food samples, providing acceptable recoveries for acidic, neutral and basic pesticides. Several applications for various food matrices (fruits, vegetables, cereals and others) in combination with chromatographic mass spectrometry analysis were presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the combustion process of ammonium dinitramide, ADN, has been modeled in two different situations: decomposition in open environment, with abundant air and decomposition in a rocket motor internal environmental conditions. The profiles of the two processes were achieved, based on molar fractions of the species that compose the products of ADN combustion. The velocity of formation and quantity of species in the open environment was bigger than the ones in the rocket motor environment, showing the effect of the different atmosphere in the reactions kinetics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Water loss and sugar gain were modelling during the osmotic dehydration process of pieces of pineaplle. The transfer of solute to the fruit and the water to the solution was based on Fick's 2nd law. The three dimensional model was solved by the finite element method with the usage of the software COMSOL Multiphysics 3.2. The main and cross diffusion coefficients and the Biot number were determined on the simulation and the deviation between the experimental and the simulated data were 4,28% to sucrose and 1,66 to the water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A laboratory experiment that enables the professor to introduce the problematic of sustainable development in pharmaceutical chemistry to undergraduate students is proposed, using a simple synthetic procedure. Cholesteryl acetate is prepared by the esterification of cholesterol using Montmorillonite K10 as heterogeneous catalyst. Cholesterol and cholesteryl acetate are characterized by spectroscopic (¹H RMN, 13C RMN, FTIR) and thermal analysis techniques. The thermal methods are used to introduce the concepts of polymorphism and the nature of mesophases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The validation of analytical methods is an important step in quality control. The main objective of this study is to propose an HPLC experiment to verify the parameters of validation of chromatographic methods, based on green chemistry principles, which can be used in experimental courses of chemistry and related areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The CBS-4M, CBS-QB3, G2, G2(MP2), G3 and G3(MP2) model chemistry methods have been used to calculate proton and electron affinities for a set of molecular and atomic systems. Agreement with the experimental value for these electronic properties is quite good considering the uncertainty in the experimental data. A comparison among the six theories using statistical analysis (average value, standard deviation and root-mean-square) showed a better performance of CBS-QB3 to obtain these properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A software based in the Monte Carlo method have been developed aiming the teaching of important cases of mechanisms found in luminescence and in excited states decay kinetics, including: multiple decays, consecutive decays and coupled systems decays. The Monte Carlo Method allows the student to easily simulate and visualize the luminescence mechanisms, focusing on the probabilities of the related steps. The software CINESTEX was written for FreeBASIC compiler; it assumes first-order kinetics and any number of excited states, where the pathways are allowed with probabilities assigned by the user.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three analytical methods for the determination of BTEX in water were optimized and validated. With the best method the analytes were extracted of 10 mL of sample with 2.50 g of NaCl in headspace vial of 20 mL by HS and SPME to 40 ºC for 30 min for adsorption and to 250 ºC for 4 min for desorption and were analyzed by GC-MS. The recovery was between 97.9% and 104.3%, and the limit of detection was 2.4 ng L-1 for o-xylene. This method was using to analyze BTEX in water supply and surface water in Ouro Preto city. No sample had concentrations of BTEX above the legislation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of analytical methods for determination of eight pesticides of different chemical classes (trichlorfon, propanil, fipronil, propiconazole, trifloxystrobin, permethrin, difenoconazole and azoxystrobin) in sediments with gas chromatography-micro-electron capture detector (GC/µECD) and comprehensive two-dimensional gas chromatography with micro-electron capture detector (GCxGC/µECD) is described. These methods were applied to real sediment samples, and the best results were obtained using a 5% diphenyl-methylpolysiloxane column for 1D-GC. For GCxGC the same column was employed in the first dimension and a 50%-phenyl-methylpolysiloxane stationary phase was placed in the second dimension. Due to the superior peak capacity and selectivity of GCxGC, interfering matrix peaks were separated from analytes, showing a better performance of GCxGC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this work is the development and validation of an analytical method for fast quantification of sibutramine in pharmaceutical formulations, using diffuse reflectance infrared spectroscopy and partial least square regression. The multivariate model was elaborated from 22 mixtures containing sibutramine and excipients (lactose, microcrystalline cellulose, colloidal silicon dioxide and magnesium stearate) and using fragmented (750-1150/ 1350-1500/ 1850-1950/ 2600-2900 cm-1) and smoothing spectral data. Using 10 latent variables, excellent predictive capacity were observed in the calibration (n=20, RMSEC=0.004, R= 0.999) and external validation (n=5, RMSEC= 9.36, R=0.999) phases. In the analysis of synthetic mixtures the precision (SD=3,47%) was compatible with the rules of the Agencia Nacional de Vigilância Sanitária (ANVISA-Brazil). In the analysis of commercial drugs good agreement was observed between spectroscopic and chromatographic methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A computational method to simulate the changes in the electronic structure of Ga1-xMn xN was performed in order to improve the understanding of the indirect contribution of Mn atoms. This periodic quantum-mechanical method is based on density functional theory at B3LYP level. The electronic structures are compared with experimental data of the absorption edge of the GaMnN. It was observed that the indirect influence of Mn through the structural parameters can account for the main part of the band gap variation for materials in the diluted regime (x<0.08), and is still significant for higher compositions (x~0.18).