78 resultados para reliability measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Patients' perception about their health condition, mainly involving chronic diseases, has been investigated in many studies and it has been associated to depression, compliance with the treatment, quality of life and prognosis. The Illness Effects Questionnaire (IEQ) is a tool which makes the standardized evaluation of patients' perception about their illness possible, so that it is brief and accessible to the different clinical settings. This work aims to begin the transcultural adaptation of the IEQ to Brazil through the validated translation and the reliability study. METHODS: The back-translation method and the test-retest reliability study were used in a sample of 30 adult patients under chronic hemodialysis. The reliability indexes were estimated using the Pearson, Spearman, Weighted Kappa and Cronbach's alpha coefficients. RESULTS: The semantic equivalence was reached through the validated translation. In this study, the reliability indexes obtained were respectively: 0.85 and 0.75 (p < 0.001); 0.68 and 0.92 (p < 0.0001). DISCUSSION: The reliability indexes obtained attest to the stability of responses in both evaluations. Additional procedures are necessary for the transcultural adaptation of the IEQ to be complete. CONCLUSION: The results indicate the translation validity and the reliability of the Brazilian version of the IEQ for the sample studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to examine the reliability and the convergent validity of the Children Anxiety Sensitivity Index (CASI) with DSM-IV anxiety disorder symptoms, by comparison with the Screen for Child Anxiety Related Emotional Disorders (SCARED), in a community sample of Brazilian children and adolescents. METHODS: Children and adolescents from five schools were selected from a larger study that aimed to assess different aspects of childhood anxiety disorders. All participants completed the CASI and the SCARED. RESULTS: This study supported the reliability of the CASI total score. Girls reported higher total anxiety sensitivity scores than boys and there were no differences in total anxiety sensitivity scores between children and adolescents. This study showed moderate to high correlations between the CASI scores with SCARED scores, all correlations coefficients being positive and significant. CONCLUSIONS: Our findings demonstrate an appropriate reliability and evidence of convergent validity in the CASI in a sample of Brazilian children and adolescents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the intraobserver reliability of the information about the history of diagnosis and treatment of hypertension. METHODS: A multidimensional health questionnaire, which was filled out by the interviewees, was applied twice with an interval of 2 weeks, in July '99, to 192 employees of the University of the State of Rio de Janeiro (UERJ), stratified by sex, age, and educational level. The intraobserver reliability of the answers provided was estimated by the kappa statistic and by the coefficient of intraclass correlation (CICC). RESULTS: The general kappa (k) statistic was 0.75 (95% CI=0.73-0.77). Reliability was higher among females (k=0.88, 95% CI=0.85-0.91) than among males (k=0.62, 95% CI=0.59-0.65).The reliability was higher among individuals 40 years of age or older (k=0.79; 95% CI=0.73-0.84) than those from 18 to 39 years (k=0.52; 95% CI=0.45-0.57). Finally, the kappa statistic was higher among individuals with a university educational level (k=0.86; 95% CI=0.81-0.91) than among those with high school educational level (k=0.61; 95% CI=0.53-0.70) or those with middle school educational level (k=0.68; 95% CI=0.64-0.72). The coefficient of intraclass correlation estimated by the intraobserver agreement in regard to age at the time of the diagnosis of hypertension was 0.74. A perfect agreement between the 2 answers (k=1.00) was observed for 22 interviewees who reported prior prescription of antihypertensive medication. CONCLUSION: In the population studied, estimates of the reliability of the history of medical diagnosis of hypertension and its treatment ranged from substantial to almost perfect reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine technical procedures and criteria used by Brazilian physicians for measuring blood pressure and diagnosing hypertension. METHODS: A questionnaire with 5 questions about practices and behaviors regarding blood pressure measurement and the diagnosis of hypertension was sent to 25,606 physicians in all Brazilian regions through a mailing list. The responses were compared with the recommendations of a specific consensus and descriptive analysis. RESULTS: Of the 3,621 (14.1%) responses obtained, 57% were from the southeastern region of Brazil. The following items were reported: use of an aneroid device by 67.8%; use of a mercury column device by 14.6%; 11.9% of the participants never calibrated the devices; 35.7% calibrated the devices at intervals < 1 year; 85.8% measured blood pressure in 100% of the medical visits; 86.9% measured blood pressure more than once and on more than one occasion. For hypertension diagnosis, 55.7% considered the patient's age, and only 1/3 relied on consensus statements. CONCLUSION: Despite the adequate frequency of both practices, it was far from that expected, and some contradictions between the diagnostic criterion for hypertension and the number of blood pressure measurements were found. The results suggest that, to include the great majority of the medical professionals, disclosure of consensus statements and techniques for blood pressure measurement should go beyond the boundaries of medical events and specialized journals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess blood pressure measurement by health professionals of a public hospital in São Paulo State. METHODS: Semi-structured interviews and direct observation were performed with a verification list according to the criteria reported by Perloff et al. One hundred and five health professionals took part in the study. After measuring blood pressure, the level of concordance between the way the procedure was performed and the recommended one was assessed. RESULTS: Nurses and nurse's aides abided by 40% of the recommended procedures for adequate blood pressure measurement. The other categories of health professionals (nursing and medicine teachers, physicians, residents, and nursing students) abided by approximately 70%. CONCLUSION: Permanent educational activities aiming at standardizing blood pressure measurement should be implemented among the different categories of health professionals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background: Studies have shown the impact of atrial fibrillation (AF) on the patients' quality of life. Specific questionnaires enable the evaluation of relevant events. We previously developed a questionnaire to assess the quality of life of patients with AF (AFQLQ version 1), which was reviewed in this study, and new domains were added. Objective: To demonstrate the reproducibility of the AFQLQ version 2 (AFQLQ v.2), which included the domains of fatigue, illness perception and well-being. Methods: We applied 160 questionnaires (AFQLQ v.2 and SF-36) to 40 patients, at baseline and 15 days after, to measure inter- and intraobserver reproducibility. The analysis of quality of life stability was determined by test-retest, applying the Bartko intraclass correlation coefficient (ICC). Internal consistency was assessed by Cronbach's alpha test. Results: The total score of the test-retest (n = 40) had an ICC of 0.98 in the AFQLQ v.2, and of 0.94 in the SF36. In assessing the intra- and interobserver reproducibility of the AFQLQ v.2, the ICC reliability was 0.98 and 0.97, respectively. The internal consistency had a Cronbach's alpha coefficient of 0.82, compatible with good agreement of the AFQLQ v.2. Conclusion: The AFQLQ v.2 performed better than its previous version. Similarly, the domains added contributed to make it more comprehensive and robust to assess the quality of life of patients with AF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to upgrade the reliability of xenodiagnosis, attention has been directed towards population dynamics of the parasite, with particular interest for the following factors: 1. Parasite density which by itself is not a research objective, but by giving an accurate portrayal of parasite development and multiplication, has been incorporated in screening of bugs for xenodiagnosis. 2. On the assumption that food availability might increase parasite density, bugs from xenodiagnosis have been refed at biweekly intervals on chicken blood. 3. Infectivity rates and positives harbouring large parasite yields were based on gut infections, in which the parasite population comprised of all developmental forms was more abundant and easier to detect than in fecal infections, thus minimizing the probability of recording false negatives. 4. Since parasite density, low in the first 15 days of infection, increases rapidly in the following 30 days, the interval of 45 days has been adopted for routine examination of bugs from xenodiagnosis. By following the enumerated measures, all aiming to reduce false negative cases, we are getting closer to a reliable xenodiagnostic procedure. Upgrading the efficacy of xenodiagnosis is also dependent on the xenodiagnostic agent. Of 9 investigated vector species, Panstrongylus megistus deserves top priority as a xenodiagnostic agent. Its extraordinary capability to support fast development and vigorous multiplication of the few parasites, ingested from the host with chronic Chagas' disease, has been revealed by the strikingly close infectivity rates of 91.2% vs. 96.4% among bugs engorged from the same host in the chronic and acute phase of the disease respectively (Table V), the latter comporting an estimated number of 12.3 x 10[raised to the power of 3] parasites in the circulation at the time of xenodiagnosis, as reported previously by the authors (1982).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A direct agglutination test (DAT) and an immunofluorescence technique (IFAT) were compared for detection of Leishmania infantum infection in 43 dogs and five foxes from Alto-Douro and Arrábida, two known endemic areas in Portugal. In four dogs with proved canine leishmaniasis, both DAT and IFAT showed positive readings (titres >1:320 and >1:128). Of 34 samples collected from apparently healthy dogs, ten were positive by both serological tests and eight were serologically positive by one test or the other. Three foxes out of five captured in this area, scored titres indicative of leishmaniasis in both DAT and IFAT. The concordance between DAT and IFAT in all collected samples (48) was 81.25%. Considering these and previous studies in the adjacent Mediterranean areas, the seroprevalence of L. infantum infection in the canine and vulpine populations appear to be of high magnitude.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Primary cultures of cardiomyocytes represent a useful model for analyzing cardiac cell biology as well as pathogenesis of several cardiovascular disorders. Our aim was to standardize protocols for determining the damage of cardiac cells cultured in vitro by measuring the creatine kinase and its cardiac isotype and lactate dehydrogenase activities in the supernatants of mice cardiomyocytes submitted to different protocols of cell lysis. Our data showed that due to its higher specificity, the cardiac isotype creatine kinase was the most sensitive as compared to the others studied enzymatic markers, and can be used to monitor and evaluate cardiac damage in in vitro assays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Program for Schistosomiasis Control within the Unified Health System (PCE-SUS) was implemented by 1999 in the Rainforest Zone or "Zona da Mata" of Pernambuco (ZMP) aiming to carry out biennial stool surveys of whole populations through municipal health organs followed by treatment of the positives through the local units of the Family Health Program (PSF). Yearly reports from the Health Department of Pernambuco State (SES/PE) from 2002 to 2004 on the PCE-SUS surveys were assessed to evaluate whether the current estimates of prevalence in the municipalities of the ZMP are based on reliable samples so as to allow considerations on the real situation of schistosomiasis in that area. The surveys carried out in that period did not follow the major principles underlying sampling design, thus posing problems in both precision and validity of the estimates. Only 12 out of 43 municipalities had minimally reliable estimates: five with moderate prevalence (10-50%) and seven with low prevalence (< 10%). Surveys with appropriate sampling procedures aimed either at representative target groups (school-aged children) or communities are recommended for the ZMP and other endemic areas not only to provide reliable information on the current situation of schistosomiasis but also to plan adequate control strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Leprosy is an infectious and contagious spectral disease accompanied by a series of immunological events triggered by the host response to the aetiologic agent, Mycobacterium leprae . The induction and maintenance of the immune/inflammatory response in leprosy are linked to multiple cell interactions and soluble factors, primarily through the action of cytokines. The purpose of the present study was to evaluate the serum levels of tumour necrosis factor (TNF)-α and its soluble receptors (sTNF-R1 and sTNF-R2) in leprosy patients at different stages of multidrug treatment (MDT) in comparison with non-infected individuals and to determine their role as putative biomarkers of the severity of leprosy or the treatment response. ELISA was used to measure the levels of these molecules in 30 healthy controls and 37 leprosy patients at the time of diagnosis and during and after MDT. Our results showed increases in the serum levels of TNF-α and sTNF-R2 in infected individuals in comparison with controls. The levels of TNF-α, but not sTNF-R2, decreased with treatment. The current results corroborate previous reports of elevated serum levels of TNF-α in leprosy and suggest a role for sTNF-R2 in the control of this cytokine during MDT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many patients with Chagas disease live in remote communities that lack both equipment and trained personnel to perform a diagnosis by conventional serology (CS). Thus, reliable tests suitable for use under difficult conditions are required. In this study, we evaluated the ability of personnel with and without laboratory skills to perform immunochromatographic (IC) tests to detect Chagas disease at a primary health care centre (PHCC). We examined whole blood samples from 241 patients and serum samples from 238 patients. Then, we calculated the percentage of overall agreement (POA) between the two groups of operators for the sensitivity (S), specificity (Sp) and positive (PPV) and negative (NPV) predictive values of IC tests compared to CS tests. We also evaluated the level of agreement between ELISAs and indirect haemagglutination (IHA) tests. The readings of the IC test results showed 100% agreement (POA = 1). The IC test on whole blood showed the following values: S = 87.3%; Sp = 98.8%; PPV = 96.9% and NPV = 95.9%. Additionally, the IC test on serum displayed the following results: S = 95.7%; Sp = 100%; PPV = 100% and NPV = 98.2%. Using whole blood, the agreement with ELISA was 96.3% and the agreement with IHA was 94.1%. Using serum, the agreement with ELISA was 97.8% and the agreement with IHA was 96.6%. The IC test performance with serum samples was excellent and demonstrated its usefulness in a PHCC with minimal equipment. If the IC test S value and NPV with whole blood are improved, then this test could also be used in areas lacking laboratories or specialised personnel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study had as its objective to analyze the intraclass reliability of the Alberta Infant Motor Scale (AIMS), in the Brazilian version, in preterm and term infants. It was a methodological study, conducted from November 2009 to April 2010, with 50 children receiving care in two public institutions in Fortaleza, Ceará, Brazil. Children were grouped according to gestational age as preterm and term, and evaluated by three evaluators in the communication laboratory of a public institution or at home. The intraclass correlation indices for the categories prone, supine, sitting and standing ranged from 0.553 to 0.952; most remained above 0.800, except for the standing category of the third evaluator, in which the index was 0.553. As for the total score and percentile, rates ranged from 0.843 to 0.954. The scale proved to be a reliable instrument for assessing gross motor performance of Brazilian children, particularly in Ceará, regardless of gestational age at birth.