69 resultados para reaction atmosphere process
Resumo:
Abstract: The aim of this study was to characterize the trajectory of answerability in Brazil. In the light of studies based on the historical neo-institutionalism approach, formal institutional changes adopted at federal level between 1985 and 2014, and which favor the typical requirements of answerability - information and justification - were identified and analyzed through the content analysis technique. The conclusion is that the trajectory of answerability in contemporary Brazil can be characterized as continuous, primarily occurring through the layering strategy, and whose leitmotif, since its origin, has consisted of matters of financial and budgetary nature. Nevertheless, a recent influence of deeper democratic subjects on it has been observed.
Resumo:
OBJETIVO: Analisar a qualidade dos serviços oferecidos por empresas operadoras de planos de saúde, segundo a percepção de usuários. MÉTODOS: Estudo transversal com 360 usuários de sete operadoras de planos de saúde da cidade de Curitiba, PR, e região metropolitana em 2008. Foi aplicado questionário sobre as preferências dos usuários em relação a seis atributos (localização dos pontos de atendimento; efetividade da ação dos médicos, clínicas e hospitais; rapidez e amabilidade no atendimento; facilidade na liberação de guias; preço; abrangência da rede credenciada) de cada uma das empresas operadoras. Para a análise das respostas foi utilizado o método Analytic Hierarchy Process (AHP, ou Processo Analítico de Hierarquia), ferramenta de análise de decisão e planejamento de múltiplos critérios. RESULTADOS: O atributo mais valorizado pelos usuários foi "preço". As empresas foram agrupadas em dois conjuntos de preferências em relação aos atributos: dos sete planos de saúde, dois apresentaram menor preferência (entre 23% e 19%) e cinco, maior preferência (em torno de 10%). CONCLUSÕES: Com esse tipo de pesquisa, as empresas operadoras de planos de saúde poderiam reformular suas estruturas, processos, preços e redes credenciadas com o objetivo de melhorar seu posicionamento no mercado.
Resumo:
OBJECTIVE To assess the determinants of exclusive breastfeeding abandonment. METHODS Longitudinal study based on a birth cohort in Viçosa, MG, Southeastern Brazil. In 2011/2012, 168 new mothers accessing the public health network were followed. Three interviews, at 30, 60, and 120 days postpartum, with the new mothers were conducted. Exclusive breastfeeding abandonment was analyzed in the first, second, and fourth months after childbirth. The Edinburgh Postnatal Depression Scale was applied to identify depressive symptoms in the first and second meetings, with a score of ≥ 12 considered as the cutoff point. Socioeconomic, demographic, and obstetric variables were investigated, along with emotional conditions and the new mothers’ social network during pregnancy and the postpartum period. RESULTS The prevalence of exclusive breastfeeding abandonment at 30, 60, and 120 days postpartum was 53.6% (n = 90), 47.6% (n = 80), and 69.6% (n = 117), respectively, and its incidence in the fourth month compared with the first was 48.7%. Depressive symptoms and traumatic delivery were associated with exclusive breastfeeding abandonment in the second month after childbirth. In the fourth month, the following variables were significant: lower maternal education levels, lack of homeownership, returning to work, not receiving guidance on breastfeeding in the postpartum period, mother’s negative reaction to the news of pregnancy, and not receiving assistance from their partners for infant care. CONCLUSIONS Psychosocial and sociodemographic factors were strong predictors of early exclusive breastfeeding abandonment. Therefore, it is necessary to identify and provide early treatment to nursing mothers with depressive symptoms, decreasing the associated morbidity and promoting greater duration of exclusive breastfeeding. Support from health professionals, as well as that received at home and at work, can assist in this process.
Resumo:
ABSTRACT OBJECTIVE To describe different approaches to promote adverse drug reaction reporting among health care professionals, determining their cost-effectiveness. METHODS We analyzed and compared several approaches taken by the Northern Pharmacovigilance Centre (Portugal) to promote adverse drug reaction reporting. Approaches were compared regarding the number and relevance of adverse drug reaction reports obtained and costs involved. Costs by report were estimated by adding the initial costs and the running costs of each intervention. These costs were divided by the number of reports obtained with each intervention, to assess its cost-effectiveness. RESULTS All the approaches seem to have increased the number of adverse drug reaction reports. We noted the biggest increase with protocols (321 reports, costing 1.96 € each), followed by first educational approach (265 reports, 20.31 €/report) and by the hyperlink approach (136 reports, 15.59 €/report). Regarding the severity of adverse drug reactions, protocols were the most efficient approach, costing 2.29 €/report, followed by hyperlinks (30.28 €/report, having no running costs). Concerning unexpected adverse drug reactions, the best result was obtained with protocols (5.12 €/report), followed by first educational approach (38.79 €/report). CONCLUSIONS We recommend implementing protocols in other pharmacovigilance centers. They seem to be the most efficient intervention, allowing receiving adverse drug reactions reports at lower costs. The increase applied not only to the total number of reports, but also to the severity, unexpectedness and high degree of causality attributed to the adverse drug reactions. Still, hyperlinks have the advantage of not involving running costs, showing the second best performance in cost per adverse drug reactions report.
Resumo:
The Montenegro skin test is widely used as a diagnostic method for American cutaneous leishmaniasis (ACL) but little is known about the histological changes that occur in the skin after administration of the antigen. This report is based on histological studies of biopsied material obtained, from inoculation sites, 48 hours after individuals had been given intradermal injections with a standardized Montenegro antigen. The material examined was obtained from four distinctly different test groups: naturally infected patients with parasitologically proved ACL and with positive Montenegro's reaction; individuals without previous history of ACL and not previously tested with Montenegro antigen; participants in anti-ACL vaccine trials who developed positive reactions to Montenegro antigen after vaccination; other participants in vaccine trials who had negative Montenegro responses after vaccination or had served as controls in the trials. The histological pictures of each group are described and discussed. Histologically, the reactions of vaccinated individuals were indistinguishable from those with naturally acquired infections.
Resumo:
Detection of HBV-DNA by PCR was compared with other serological markers (HBsAg, HBeAg and anti-HBe) in a series of49 Chronic Hepatitis B patients, including 12 with a spontaneous clearance of HBsAg. None of these HBsAg negative cases were PCR positive, but 33/37 (89.2%) HBsAg positive cases were PCR positive (p < 0.0001). Among HBsAg positive samples, nine cases were HBeAg positive and anti-HBe negative, all of them PCR positive. Other 3 patients were HBeAg and anti-HBe positive and these cases were also found PCR positive. A third group included 21 patients anti-HBe positive and HBeAg negative: 19 of them were PCR positive and 2 were PCR negative. The last 4 cases were HBeAg and anti-HBe negative, two of them were PCR positive. The detection of anti-HBe viremic cases in the present series suggest that preC variants could occur in our country. In conclusion, the integrated phase o f chronic hepatitis B seems to be less frequent than it was assumed, when only HBeAg or dot blot hybridization techniques were used. The new term "low replication phase" might favorably replace the former "integrated phase".
Resumo:
Faeces of 138 chickens were inoculated on Blaser agar plates. One set of plates was incubated in jars with CampyPak envelopes. The others were incubated in "Zip-lock" plastic bags (7 x X in.) and a microaerophilic atmosphere was generated exhaling into the "Zip-lock" plastic bag, after holding the breath for 20 sec. Then, the bag was pressed to evacuate its atmosphere, inflated again, and pressed (4 times), and finally sealed. Campylobacter was isolated from 127 (96.2%) of samples incubated in jars with gas generator envelopes and from 129 (98%) of the specimens incubated into the bags. The proposed methodology offers good savings for cost-conscious laboratories.
Resumo:
We show here a simplified RT-PCR for identification of dengue virus types 1 and 2. Five dengue virus strains, isolated from Brazilian patients, and yellow fever vaccine 17DD as a negative control, were used in this study. C6/36 cells were infected and supernatants were collected after 7 days. The RT-PCR, done in a single reaction vessel, was carried out following a 1/10 dilution of virus in distilled water or in a detergent mixture containing Nonidet P40. The 50 µl assay reaction mixture included 50 pmol of specific primers amplifying a 482 base pair sequence for dengue type 1 and 210 base pair sequence for dengue type 2. In other assays, we used dengue virus consensus primers having maximum sequence similarity to the four serotypes, amplifying a 511 base pair sequence. The reaction mixture also contained 0.1 mM of the four deoxynucleoside triphosphates, 7.5 U of reverse transcriptase, 1U of thermostable Taq DNA polymerase. The mixture was incubated for 5 minutes at 37ºC for reverse transcription followed by 30 cycles of two-step PCR amplification (92ºC for 60 seconds, 53ºC for 60 seconds) with slow temperature increment. The PCR products were subjected to 1.7% agarose gel electrophoresis and visualized by UV light after staining with ethidium bromide solution. Low virus titer around 10 3, 6 TCID50/ml was detected by RT-PCR for dengue type 1. Specific DNA amplification was observed with all the Brazilian dengue strains by using dengue virus consensus primers. As compared to other RT-PCRs, this assay is less laborious, done in a shorter time, and has reduced risk of contamination
Resumo:
A polymerase chain reaction was carried out to detect pathogenic leptospires isolated from animals and humans in Argentina. A double set of primers (G1/G2, B64-I/B64-II), described before, were used to amplify by PCR a DNA fragment from serogroups belonging to Leptospira interrogans but did not allow to detect saprophytic strains isolated from soil and water (L. biflexa). This fact represents an advantage since it makes possible the differentiation of pathogenic from non-pathogenic leptospires in cultures. The sensitivity of this assay has been determined, allowing to detect just only 10 leptospires in the reaction tube. Those sets of primers generated either a 285 bp or 360 bp fragment, depending on the pathogenic strain
Resumo:
This work was planned by taking into account all the knowledge accumulated from the immunological study of paracoccidioidomycosis. It aimed at comparing a polysaccharide antigen from Histoplasma capsulatum to a classic histoplasmin with the help of intradermal tests of delayed type of hypersensitivity. Tests were applied to 115 individuals in Santo Amaro, a town in the state of São Paulo. Positive results using classic histoplasmin were obtained in 46.0% cases whereas positive results using the polysaccharide antigen at its hightest concentration were obtained in 51.30% cases. The major conclusion in this investigation is that it is possible to use the polysaccharide antigen as histoplasmin instead of the filtrate antigen
Resumo:
The objective of the present study was to determine the prevalence of certain mycoplasma species, i.e., Mycoplasma hominis, Ureaplasma urealyticum and Mycoplasma penetrans, in urethral swabs from HIV-1 infected patients compared to swabs from a control group. Mycoplasmas were detected by routine culture techniques and by the Polymerase Chain Reaction (PCR) technique, using 16SrRNA generic primers of conserved region and Mycoplasma penetrans specific primers. The positivity rates obtained with the two methods were comparable. Nevertheless, PCR was more sensitive, while the culture techniques allowed the quantification of the isolates. The results showed no significant difference (p < 0.05) in positivity rates between the methods used for mycoplasma detection.
Resumo:
Treatment of mucosal leishmaniasis (ML) can be controlled by clinical examination and by serologic titers by the indirect immunofluorescence serologic reaction (IISR). We studied the correlation between the presence of antigen in tissue determined by immunohistochemistry, the IISR titers and the anatomopathologic findings in fifteen patients with ML before and after healing of the lesions as determined by otorhinolaryngologic evaluation, and evaluated these parameters to determine which of them could be useful during follow-up. Tissue antigens became negative in four patients (group A) after treatment, with a statistically significant reduction or negativity of IISR titers (p<0.05). This did not occur in patients in whom the antigen persisted after treatment (group B), suggesting that serologic follow-up should be performed together with the search for tissue antigen, a combination which, to our knowledge, has not been used in previous studies. The negativity of tissue antigens and the behavior of IIRS titers in group A patients probably indicate a lower possibility of recurrence. Upon anatomopathologic examination the inflammatory process was found to persist after treatment even in group A, suggesting that the permanence of inflammatory activity even in clinically healed lesions is possibly correlated with the presence of the antigen or of some unknown factor.
Resumo:
Screening blood donations for anti-HCV antibodies and alanine aminotransferase (ALT) serum levels generally prevents the transmission of hepatitis C virus (HCV) by transfusion. The aim of the present study was to evaluate the efficiency of the enzyme immunoassay (EIA) screening policy in identifying potentially infectious blood donors capable to transmit hepatitis C through blood transfusion. We have used a reverse transcriptase (RT)-nested polymerase chain reaction (PCR) to investigate the presence of HCV-RNA in blood donors. The prevalence of HCV-RNA positive individuals was compared with the recombinant immunoblot assay (RIBA-2) results in order to assess the usefulness of both tests as confirmatory assays. Both tests results were also compared with the EIA-2 OD/C ratio (optical densities of the samples divided by the cut off value). ALT results were expressed as the ALT quotient (qALT), calculated dividing the ALT value of the samples by the maximum normal value (53UI/l) for the method. Donors (n=178) were divided into five groups according to their EIA anti-HCV status and qALT: group A (EIA > or = 3, ALT<1), group B (EIA > or = 3, ALT>1), group C (1<=EIA<3, ALT<1), group D (1<=EIA<3, ALT>1) and group E (EIA<=0.7). HCV sequences were detected by RT-nested PCR, using primers for the most conserved region of viral genome. RIBA-2 was applied to the same samples. In group A (n=6), all samples were positive by RT-nested PCR and RIBA-2. Among 124 samples in group B, 120 (96.8%) were RIBA-2 positive and 4 (3.2%) were RIBA-2 indeterminate but were seropositive for antigen c22.3. In group B, 109 (87.9%) of the RIBA-2 positive samples were also RT-nested PCR positive, as well as were all RIBA-2 indeterminate samples. In group C, all samples (n=9) were RT-nested PCR negative: 4 (44.4%) were also RIBA-2 negative, 4 (44.4%) were RIBA-2 positive and 1 (11.1%) was RIBA-2 indeterminate. HCV-RNA was detected by RT-nested PCR in 3 (37.5%) out of 8 samples in group D. Only one of them was also RIBA-2 positive, all the others were RIBA-2 indeterminate. All of the group E samples (controls) were RT- nested PCR and RIBA-2 negative. Our study suggests a strong relation between anti-HCV EIA-2 ratio > or = 3 and detectable HCV-RNA by RT-nested PCR. We have also noted that blood donors with RIBA-2 indeterminate presented a high degree of detectable HCV-RNA using RT-nested PCR (75%), especially when the c22.3 band was detected.