37 resultados para potentiometric precipitation titrations
Resumo:
Potentiometric studies of sulfathiazole (HST) in the presence and absence of cobalt(II) were performed. Equilibrium constants for the formation of the detected species, [Co(ST)]+ and [Co(ST)(OH)], are reported. UV-Vis spectrophotometric measurements suggest that the coordination Co(II)-sulfathiazole might be through a N atom, which, in agreement with MO calculations, could be a thiazolic one. In spite of sulfonamides being better ligands at pH >7, [Co(ST)]+ was found at pH » 3.
Resumo:
In potentiometric titrations of metal cations with EDTA the Hg/HgY2- system is usually used to detect the end point. However, the use of mercury has been discouraged in analytical procedures due to its toxicity. In this work the Cu/CuY2- system was used as indicator electrode for potentiometric titrations of some metal cations with EDTA. The solutions of Cu2+, Cd2+, Mn2+, Co2+ and Zn2+ were titrated with Na2EDTA solution in the presence of a small concentration of the CuY2- complex using a copper wire as indicator electrode. The potentiometric titrations with the Cu/CuY2- system showed good correlation when compared with an Hg/HgY2- system.
Resumo:
This works proposes a homemade construction of a lead(II) ISE of solid membrane (Ag2S/PbS) to determine Pb2+ ions in potentiometric titrations, using damaged combined glass electrodes. This electrode can be constructed in teaching laboratories, using it as a learning tool related to the theoretical principle of ISE. The analytical curve obtained (y = 27.056x + 337.58; R = 0.996) was linear on the range of 1 x 10-5 to 1 mol L-1 and has presented a very close behavior of the Nernstian. The homemade ISE has presented a similar selectivity to the commercial electrodes, showing to be a good alternative to the experimental activities on teaching laboratories.
pH effect on the synthesis of magnetite nanoparticles by the chemical reduction-precipitation method
Resumo:
This work aimed at putting in evidence the influence of the pH on the chemical nature and properties of the synthesized magnetic nanocomposites. Saturation magnetization measurements evidenced a marked difference of the magnetic behavior of samples, depending on the final pH of the solution after reaction. Magnetite and maghemite in different proportions were the main magnetic iron oxides actually identified. Synthesis with final pH between 9.7-10.6 produced nearly pure magnetite with little or no other associated iron oxide. Under other synthetic conditions, goethite also appears in proportions that depended upon the pH of the synthesis medium.
Resumo:
The determination of acetic acid in vinegar adulterated sample using simultaneous potentiometric and condutometric titrations was used as an example of integrated experiment in instrumental analysis. An Excel® spreadsheet, which allows the entry of simultaneous data and the construction of the superimposed experimental curves (condutometric, potentiometric, first and second derivative potentiometric curve and, distribution diagrama of the acetic species as function of pH), was used as powerful tool to discuss the fundamental concepts involved in each technique and choose the best of them to quantify, without mutual interference, H3CCOOH and HCl in vinegar adulterated sample.
Resumo:
This work describes the creation of an very simple calculation algorithm, based in basic chemical and mathematic principles, for the calculation of weak diprotic acid dissociation constants as, for example, amino acids, from potentiometric titrations. For an easier understanding of the algorithm the logical reasoning of this calculus is schematized in a diagram of blocks. In the second part of the work the algorithm is applied to an Excel calculation sheet to determine the dissociation constants of Nicotinic Acid and Glycine, from the respective potentiometric titration curves. The values obtained using this algorithm are compared with those estimated by Hyperquad2008 (program generally used for this type of calculus) and also with the values of a stability constants database.
Resumo:
This paper reports the development and validation of a new analytical method using UV spectrophotometry to quantify carvedilol (CRV) in hydrophilic matrices and raw material. This method was shown to be linear, accurate, precise, robust and to have adequate limits of quantification and detection (LQ and LD, respectively), allowing its use in the dissolution test of hydrophilic matrices. The content of CRV determined through this method was compared with two previously validated methods based on the reference techniques of High Performance Liquid Chromatography (HPLC) and Potentiometric Titrations (PT). ANOVA confirmed the equivalence of these methods, showing no significant differences.
Resumo:
Previous studies have verified that free radicals such as quinone moieties in organic matter participate in the redox reactions in natural systems. These functional groups were positively correlated with the increase in aromaticity and hydrophobicity of the humic substances. As an alternative to relatively complex and expensive spectroscopic methods, the redox properties of the humic substances, determined by potentiometric titrations, have been used to evaluate organic carbon stability in soil and sediments. The present study aimed to perform organic matter fractionation and isolation of humic substances from deep oceans in different isobaths (750; 1,050; 1,350; 1,650; 1,950 m) to determine their redox properties by iodimetric titrations under an inert atmosphere and specified conditions of pH and ionic strength. Sediment samples were collected to the North and South of platforms of petroleum exploration located in the North of Rio de Janeiro State, Brazil. Fractions of organic carbon and redox properties of humic substances varied with origin and depth of the samples and with position North and South of the petroleum exploration area.
Resumo:
A potentiometric Nickel sensor was prepared using 2-hydroxy-1-naphthylidene-N-cyanoacetohydrazone as electro-active material and epoxy resin as a binding material. A membrane composed of 40% Schiff's base and 60% epoxy resin exhibited the best performance. The membrane showed excellent response in the concentration range of 0.15 ppm to 0.1 mol L- 1 Ni+2 ions with non-Nernstian slope of 22.0 mV/decade, had a rapid response time (less than 10 s), and can be used for three months without any considerable loss of potential. The sensor was useful within the pH range of 1.3 to 9.6, and was able to discriminate between Ni2+ and a large number of alkaline earth and transition metal ions. The practical utility of the sensor has been demonstrated by using it successfully as an indicator electrode in the potentiometric titration of Ni2+ with EDTA and oxalic acid.
Resumo:
The synthesis of polyacrylamide-cellulose acetate hydrogels by precipitation polymerization in acetone solution is reported herein. These hydrogels exhibit smaller swelling ratios and larger compression moduli than homo polyacrylamide hydrogels. For cellulose acetate concentrations above 20 wt.%, hydrogels with N,N'-methylenebisacrylamide as a crosslinker exhibit swelling ratios and compression moduli similar to those of the hydrogels without the crosslinker. A possible explanation for this behavior is that cellulose acetate crosslinks polyacrylamide via free-radical reaction. The hydrogels obtained without the N,N'-methylenebisacrylamide crosslinker exhibit compression moduli up to 1.7 MPa, making them suitable for tissue engineering applications such as cartilage replacement.
Resumo:
The ligand di-2-pyridyl ketone benzoylhydrazone (DPKBH) is widely used for the determination of transition metal ions in environmental samples. Due to its low solubility in water it is used in aqueous-ethanol (1:1) solvent and for higher sensitivity the pH must be properly adjusted. The properties of DPKBH solutions must be known at different ethanol-water percentages in order to achieve higher sensitivity and/or selectivity for metal analysis. The acid-base behavior of this reagent in aqueous-ethanol solvent and the dissociation/ionization constants (pK1 and pK2) of DPKBH have been determined in different aqueous-ethanol solvent mixtures (10, 20, 30 and 50 % V/V of ethanol) from potentiometric titrations at 25.0 ± 0.1° C. As the amount of ethanol increases from 10 to 30% the pK1 and pK2 values increased, but they decreased in 50% of the organic solvent. The results are correlated with the medium composition and its effects.
Resumo:
A simple, precise, rapid and low-cost potentiometric method for captopril determination in pure form and in pharmaceutical preparations is proposed. Captopril present in tablets containing known quantity of drug was potentiometrically titrated in aqueous solution with NaOH using a glass pH electrode, coupled to an autotitrator. No interferences were observed in the presence of common components of the tablets as lactose, microcrystalline cellulose, croscarmellose sodium, starch and magnesium stearate. The analytical results obtained by applying the proposed method compared very favorably with those obtained by the United States Pharmacopoeia Standard procedure. Recovery of captopril from various tablet dosage formulations range from 98.0 to 102.0%.
Resumo:
A direct potentiometric titration method was applied to commercial and soil humic acids in order to determine their carboxyl and phenol group concentrations and apparent and intrinsic pK. In that context, acid-base properties of humic acids are interpreted by selective blocking of carboxylic and phenolic groups by esterification and acetylation. Differences in underivatized and derivatized HA's acid-base properties are ascribed to carboxyl and phenol groups influence on total humic acidity. Potentiometric data were treated with the modified Henderson-Hasselbalch equation. Infra red results, the acidic group contents and the average values of apparent and intrinsic pK for underivatized and derivatized HAs confirmed the selectivity of esterification derivatization method. After blocking of the functional groups, the values of acidic group contents decreased, while the value of apparent pK increased after derivatization. Phenol groups cannot be specifically identified by the acetylation method, due to low selectivity of the acetylation method.
Resumo:
A potentiometric titration method for the determination of minoxidil based on its redox reaction with K2Cr2O7 is described. The best results were observed using 1.00 x 10-3 mol L-1 K2Cr2O7 and 1.00 x 10-2 mol L-1 minoxidil solutions, and the minoxidil as titrant in 2.00 mol L-1 H2SO4 medium. The method was applied to commercial samples and compared with the results from a chromatographic procedure. Recoveries from 97.4 to 98.7 % were observed depending on the sample. Comparison with the chromatographic procedure reveled agreement within 90% confidence level.
Resumo:
In this study the BEST7 software was employed to quantify different classes of functional groups and to model the proton titration behavior of humic substances. To illustrate the process, the Suwannee River fulvic acid of the IHSS (International Humic Substances Society) was used. Five categories - two classes of phenolic groups (phenol and cathecol), two classes of carboxylic groups (benzoic and phtalic) and the combination between them (salicylic) - of oxygenated groups were considered as being responsible for the potentiometric behavior of the sample and were quantitatively determined. The most and the least abundant groups were cathecol (3.300 ± 0.010 mmol g-1) and phenol (1.225 ± 0.070 mmol g-1), respectively. The estimated equilibrium constants were also determined and were in good agreement with the literature values for phenol and cathecol groups and for benzoic, phtalic and salicylic acids. Distribution diagrams of the species were generated with the software SPE and SPEPLOT.