27 resultados para pacemaker, defibrillatore, cuore, evoluzione, dispositivi


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To study the effect of propafenone on the contractile function of latissimus dorsi muscle isolated from rats in an organ chamber. METHODS: We studied 20 latissimus dorsi muscles of Wistar rats and divided them into 2 groups: group I (n=10), or control group - we studied the feasibility of muscle contractility; group II (n=10), in which the contralateral muscles were grouped - we analyzed the effect of propafenone on muscle contractility. After building a muscle ring, 8 periods of sequential 2-minute baths were performed, with intervals of preprogrammed electrical stimulation using a pacemaker of 50 stimuli/min. In group II, propafenone, at the concentration of 9.8 µg/mL, was added to the bath in period 2 and withdrawn in period 4. RESULTS: In group I, no significant depression in muscle contraction occurred up to period 5 (p>0.05). In group II, a significant depression occurred in all periods, except between the last 2 periods (p<0.05). Comparing groups I and II only in period 1, which was a standard period for both groups, we found no significant difference (p>0.05). CONCLUSION: Propafenone had a depressing effect on the contractile function of latissimus dorsi muscle isolated from rats and studied in an organ chamber.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Glossopharyngeal neuralgia is an uncommon condition that has rarely been described in association with syncope. We report here 2 cases of glossopharyngeal neuralgia in elderly patients. Both were male and underwent temporary pacemaker insertion to prevent syncopal episodes. We discuss the clinical and surgical treatment of glossopharyngeal neuralgia, the role of cardiac stimulation, and the possible physiopathological mechanism of the associated cardiac disturbances.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chloroquine has been widely used in rheumatological treatment, but potential severe side effects require careful follow-up. Cardiac damage is not a common consequence, but its clinical relevance has not yet been described. We report the case of a 58-year-old woman with rheumatoid arthritis, in whom chronic chloroquine use resulted in major irreversible cardiac damage. She presented with syncopal episodes due to complete atrioventricular block confirmed by electrophysiological study whose changes were concluded to be irreversible and a permanent pacemaker was indicated. Endomyocardial biopsy was also performed to search for histopathological and ultrastructural cardiac damage. We also reviewed the 22 cases of chloroquine-induced cardiopathy described to date as well as its pathophysiology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 61 year-old Chagasic woman, with previous left ventricular systolic disfunction, ventricular tachychardia and cardiac pacemaker, presented cardiac arrest in asystolia after surgical ressection of apical aneurysm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AbstractIn children with structural congenital heart disease (CHD), the effects of chronic ventricular pacing on diastolic function are not well known. On the other hand, the beneficial effect of septal pacing over apical pacing is still controversial.The aim of this study was to evaluate the influence of different right ventricular (RV) pacing site on left ventricular (LV) diastolic function in children with cardiac defects.Twenty-nine pediatric patients with complete atrioventricular block (CAVB) and CHD undergoing permanent pacing were prospectively studied. Pacing sites were RV apex (n = 16) and RV septum (n = 13). Echocardiographic assessment was performed before pacemaker implantation and after it, during a mean follow‑up of 4.9 years.Compared to RV septum, transmitral E-wave was significantly affected in RV apical pacing (95.38 ± 9.19 vs 83 ± 18.75, p = 0.038). Likewise, parameters at the lateral annular tissue Doppler imaging (TDI) were significantly affected in children paced at the RV apex. The E´ wave correlated inversely with TDI lateral myocardial performance index (Tei index) (R2= 0.9849, p ≤ 0.001). RV apex pacing (Odds ratio, 0.648; confidence interval, 0.067-0.652; p = 0.003) and TDI lateral Tei index (Odds ratio, 31.21; confidence interval, 54.6-177.4; p = 0.025) predicted significantly decreased LV diastolic function.Of the two sites studied, RV septum prevents pacing-induced reduction of LV diastolic function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AbstractBackground:30-40% of cardiac resynchronization therapy cases do not achieve favorable outcomes.Objective:This study aimed to develop predictive models for the combined endpoint of cardiac death and transplantation (Tx) at different stages of cardiac resynchronization therapy (CRT).Methods:Prospective observational study of 116 patients aged 64.8 ± 11.1 years, 68.1% of whom had functional class (FC) III and 31.9% had ambulatory class IV. Clinical, electrocardiographic and echocardiographic variables were assessed by using Cox regression and Kaplan-Meier curves.Results:The cardiac mortality/Tx rate was 16.3% during the follow-up period of 34.0 ± 17.9 months. Prior to implantation, right ventricular dysfunction (RVD), ejection fraction < 25% and use of high doses of diuretics (HDD) increased the risk of cardiac death and Tx by 3.9-, 4.8-, and 5.9-fold, respectively. In the first year after CRT, RVD, HDD and hospitalization due to congestive heart failure increased the risk of death at hazard ratios of 3.5, 5.3, and 12.5, respectively. In the second year after CRT, RVD and FC III/IV were significant risk factors of mortality in the multivariate Cox model. The accuracy rates of the models were 84.6% at preimplantation, 93% in the first year after CRT, and 90.5% in the second year after CRT. The models were validated by bootstrapping.Conclusion:We developed predictive models of cardiac death and Tx at different stages of CRT based on the analysis of simple and easily obtainable clinical and echocardiographic variables. The models showed good accuracy and adjustment, were validated internally, and are useful in the selection, monitoring and counseling of patients indicated for CRT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Background: Cardiac resynchronization therapy (CRT) is the recommended treatment by leading global guidelines. However, 30%-40% of selected patients are non-responders. Objective: To develop an echocardiographic model to predict cardiac death or transplantation (Tx) 1 year after CRT. Method: Observational, prospective study, with the inclusion of 116 patients, aged 64.89 ± 11.18 years, 69.8% male, 68,1% in NYHA FC III and 31,9% in FC IV, 71.55% with left bundle-branch block, and median ejection fraction (EF) of 29%. Evaluations were made in the pre‑implantation period and 6-12 months after that, and correlated with cardiac mortality/Tx at the end of follow-up. Cox and logistic regression analyses were performed with ROC and Kaplan-Meier curves. The model was internally validated by bootstrapping. Results: There were 29 (25%) deaths/Tx during follow-up of 34.09 ± 17.9 months. Cardiac mortality/Tx was 16.3%. In the multivariate Cox model, EF < 30%, grade III/IV diastolic dysfunction and grade III mitral regurgitation at 6‑12 months were independently related to increased cardiac mortality or Tx, with hazard ratios of 3.1, 4.63 and 7.11, respectively. The area under the ROC curve was 0.78. Conclusion: EF lower than 30%, severe diastolic dysfunction and severe mitral regurgitation indicate poor prognosis 1 year after CRT. The combination of two of those variables indicate the need for other treatment options.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Evidence has indicated that the sarcoplasmic reticulum (SR) might be involved in the generation of spontaneous electrical activity in atrial pacemaker cells. We report the effect of disabling the SR with ryanodine (0.1 µM) on the sinus node recovery time (SNRT) measured in isolated right atria from 4-6-month-old male Wistar rats. Electrogram and isometric force were recorded at 36.5oC. Two methods for sinus node resetting were used: a) pulse: a single stimulus pulse interpolated at coupling intervals of 50, 65 or 80% of the regular spontaneous cycle length (RCL), and b) train: a 2-min train of pulses at intervals of 50, 65 or 80% of RCL. Corrected SNRT (cSNRT) was calculated as the difference between SNRT (first spontaneous cycle length after stimulation interruption) and RCL. Ryanodine only slightly increased RCL (<10%), but decreased developed force by 90%. When the pulse method was used, cSNRT (~40 ms), which represents intranodal/atrial conduction time, was independent of the coupling interval and unaffected by ryanodine. However, cSNRT obtained by the train method was significantly higher for shorter intervals between pulses, indicating the occurrence of overdrive suppression. In this case, ryanodine prolonged cSNRT in a rate-dependent fashion, with a greater effect at shorter intervals. These results indicate that: a) a functional SR, albeit important for force development, does not seem to play a major role in atrial automaticity in the rat; b) disruption of cell Ca2+ homeostasis by inhibition of SR function does not appear to affect conduction; however, it enhances overdrive-induced depression of sinusal automaticity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Circadian timing is structured in such a way as to receive information from the external and internal environments, and its function is the timing organization of the physiological and behavioral processes in a circadian pattern. In mammals, the circadian timing system consists of a group of structures, which includes the suprachiasmatic nucleus (SCN), the intergeniculate leaflet and the pineal gland. Neuron groups working as a biological pacemaker are found in the SCN, forming a biological master clock. We present here a simple model for the circadian timing system of mammals, which is able to reproduce two fundamental characteristics of biological rhythms: the endogenous generation of pulses and synchronization with the light-dark cycle. In this model, the biological pacemaker of the SCN was modeled as a set of 1000 homogeneously distributed coupled oscillators with long-range coupling forming a spherical lattice. The characteristics of the oscillator set were defined taking into account the Kuramoto's oscillator dynamics, but we used a new method for estimating the equilibrium order parameter. Simultaneous activities of the excitatory and inhibitory synapses on the elements of the circadian timing circuit at each instant were modeled by specific equations for synaptic events. All simulation programs were written in Fortran 77, compiled and run on PC DOS computers. Our model exhibited responses in agreement with physiological patterns. The values of output frequency of the oscillator system (maximal value of 3.9 Hz) were of the order of magnitude of the firing frequencies recorded in suprachiasmatic neurons of rodents in vivo and in vitro (from 1.8 to 5.4 Hz).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The atrioventricular (AV) node is permanently damaged in approximately 3% of congenital heart surgery operations, requiring implantation of a permanent pacemaker. Improvements in pacemaker design and in alternative treatment modalities require an effective in vivo model of complete heart block (CHB) before testing can be performed in humans. Such a model should enable accurate, reliable, and detectable induction of the surgical pathology. Through our laboratory’s efforts in developing a tissue engineering therapy for CHB, we describe here an improved in vivo model for inducing chronic AV block. The method employs a right thoracotomy in the adult rabbit, from which the right atrial appendage may be retracted to expose an access channel for the AV node. A novel injection device was designed, which both physically restricts needle depth and provides electrical information via electrocardiogram interface. This combination of features provides real-time guidance to the researcher for confirming contact with the AV node, and documents its ablation upon formalin injection. While all animals tested could be induced to acute AV block, those with ECG guidance were more likely to maintain chronic heart block >12 h. Our model enables the researcher to reproduce both CHB and the associated peripheral fibrosis that would be present in an open congenital heart surgery, and which would inevitably impact the design and utility of a tissue engineered AV node replacement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La differenza tra i concetti di saṃsāra e nirvāṇastabilita dal Buddha (VI-V sec. a.C.) nel suo primo sermone sembra essere messa in discussione dall'equiparazione dei due termini effettuata da Nāgārjuna (II sec. d.C.) in un passaggio-chiave delle sue MK. Questo articolo, in primo luogo, difende la tesi che la contraddizione sia soltanto apparente e che la relazione, di differenza o di identità, tra le due dimensioni dipende dal registro filosofico, rispettivamente epistemologico e ontologico, usato - in entrambi i casi per finalità soteriologiche - dal Buddha e da Nāgārjuna. In secondo luogo, cercheremo di provare che, in ogni caso, l'ontologia di Nāgārjuna, lungi dall'essere una novità filosofica o un'evoluzione rispetto al pensiero del fondatore del buddhismo è, al contrario, una delle possibili applicazioni della dottrina del non-sé (anātma-vāda) - probabilmente il contributo più importante e originale del pensiero buddhista alla storia della filosofia universale - esposta dal Buddha nel suo secondo sermone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Il saggio, attraverso un'analisi delle riflessioni di Husserl e Scheler, si propone di esaminare la loro concezione sull'Europa e la tradizione culturale europea, mettendo in rilievo l'evoluzione e lo sviluppo delle loro posizioni avanti e dopo la prima Guerra mondiale.