122 resultados para bacteremia-catheter
Resumo:
OBJECTIVE: To identify useful clinical characteristics for selecting patients eligible for mapping and ablation of atrial fibrillation. METHODS: We studied 9 patients with atrial fibrillation, without structural heart disease, associated with: 1) antiarrhythmic drugs, 2) symptoms of low cardiac output, and 3) intention to treat. Seven patients had paroxysmal atrial fibrillation and 2 had recurrent atrial fibrillation. RESULTS: In the 6 patients who underwent mapping (all had paroxysmal atrial fibrillation), catheter ablation was successfully carried out in superior pulmonary veins in 5 patients (the first 3 in the left superior pulmonary vein and the last 2 in the right superior pulmonary vein). One patient experienced a recurrence of atrial fibrillation after 10 days. We observed that patients who had short episodes of atrial fibrillation on 24-hour Holter monitoring before the procedure were those in whom mapping the focus of tachycardia was possible. Tachycardia was successfully suppressed in 4 of 6 patients. The cause of failure was due to the impossibility of maintaining sinus rhythm long enough for efficient mapping. CONCLUSION: Patients experiencing short episodes of atrial fibrillation during 24-hour Holter monitoring were the most eligible for mapping and ablation, with a final success rate of 66%, versus the global success rate of 44%. Patients with persistent atrial fibrillation were not good candidates for focal ablation.
Resumo:
OBJECTIVE: To determine whether recording of the activation potential may be used as an isolated criterion to guide catheter ablation of atriofascicular Mahaim fibers. METHODS: We studied 6 patients (5 females, mean age of 26±7.3 years) with paroxysmal tachycardias with a wide QRS complex, whose electrophysiological study diagnosed atriofascicular Mahaim fibers. Mapping and catheter ablation were performed in sinus rhythm, guided only by the recording of the activation potential of the fiber. RESULTS: Efficacy in ablation was achieved in all patients. The fibers were located in the right lateral region of the tricuspid ring in 3 patients, right posterolateral region in 2, and right anterolateral region in 1. A mean of 5.3±3 radiofrequency applications was performed. The mean fluoroscopy time was 46.6±25 minutes, and the mean duration of the procedure was 178.6±108 minutes. No complication occurred. In a mean 20-month follow-up, all patients were asymptomatic and receiving no antiarrhythmic drugs. CONCLUSION: Catheter ablation of Mahaim fibers may be performed with good safety and efficacy by mapping the activation potential of the tricuspid ring in sinus rhythm.
Resumo:
OBJECTIVE: To report short and midtem follow-up results of balloon aortic valvuloplasty to treat congenital aortic stenosis. METHODS: Seventy-five patients (median age: 8 years) underwent the procedure through the retrograde femoral or carotid route. RESULTS: The procedure was completed in 74 patients (98.6%). The peak-to-peak systolic gradient dropped from 79.6±27.7 to 22.3±17.8 mmHg (P<0.001), the left ventricular systolic pressure dropped from 164±39.1 to 110±24.8 mmHg (P<0.001), and the left ventricular end diastolic pressure dropped from 13.3±5.5 to 8.5±8.3 mmHg (P< 0.01). Four patients (5.3%) died due to the procedure. Aortic regurgitation (AoR) appeared or worsened in 27/71 (38%) patients, and no immediate surgical intervention was required. A mean follow-up of 50±38 months was obtained in 37 patients. Restenosis and significant AoR were observed in 16.6% of the patients. The estimates for being restenosis-free and for having significant AoR in 90 months were 60% and 50%, respectively. CONCLUSION: Aortic valvuloplasty was considered the initial palliative method of choice in managing congenital aortic stenosis, with satisfactory short- and midterm results.
Resumo:
Over the past two decades, nosocomial infections caused by extended-spectrum beta-lactamase (ESBL)-producing Klebsiella spp. have become a major problem all around the world. This situation is of concern because there are limited antimicrobial options to treat patients infected with these pathogens, and also because this kind of resistance can spread to a wide variety of Gram-negative bacilli. Our objectives wereto evaluate among in-patients at a publicuniversity tertiary-care hospital with documented infection due to Klebsiella spp., which were the risk factors (cross-sectional analysis) and the clinical impact (prospective cohort) associated with an ESBL-producing strain. Study subjects were all patients admitted at the study hospital between April 2002 and October 2003, with a clinically and microbiologically confirmed infection caused by Klebsiella spp. at any body site, except infections restricted to the urinary tract. Of the 104 patients studied, 47 were infected with an ESBL-producing strain and 57 with a non-ESBL-producing strain. Independent risk factors associated with infection with an ESBL-producing strain were young age, exposure to mechanical ventilation, central venous catheter, use of any antimicrobial agent, and particularly use of a 4th generation cephalosporin or a quinolone. Length of stay was significant longer for patients infected with ESBL-producing strains than for those infected with non-ESBL-producing strains, although fatality rate was not significantly affected by ESBL-production in this cohort. In fact, mechanical ventilation and bacteremia were the only variables withindependent association withdeath detected in this investigation.
Resumo:
Abstract OBJECTIVE To evaluate the incidence of complications related to the use of peripheral intravenous catheter in neonates and identify the associated risk factors. METHOD Prospective cohort study conducted in a Neonatal Intensive Care Unit. Participants were the hospitalized neonates undergoing peripheral intravenous puncture in the period from February to June 2013. RESULTS The incidence of complications was 63.15%, being infiltration/extravasation (69.89%), phlebitis (17.84%) and obstruction (12.27%). The risk factors were the presence of infection (p = 0.0192) and weight at the puncture day (p = 0.0093), type of intermittent infusion associated with continuous infusion (p <0.0001), endotracheal intubation (p = 0.0008), infusion of basic plan (p = 0.0027), total parenteral nutrition (P = 0.0002), blood transfusion associated with other infusions (p = 0.0003) and other drugs (p = 0.0004). Higher risk of developing complications in the first 48 hours after puncture. CONCLUSION A high rate of complications related to the use of peripheral intravenous catheter, and risk factors associated with infection, weight, drugs and infused solutions, and type of infusion.
Resumo:
Objective Comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and Methods Simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT were performed with the MCNP5 code, modeling the treatment of a brain tumor on a voxel computational phantom representing a human head. Absorbed dose rates were converted into biologically weighted dose rates. Results Intracavitary balloon catheter brachytherapy with I-125 produced biologically weighted mean dose rates of 3.2E-11, 1.3E-10, 1.9E-11 and 6.9E-13 RBE.Gy.h-1.p-1.s, respectively, on the healthy tissue, on the balloon periphery and on the I 1 and I 2 tumor infiltration zones. On the other hand, Cf-252 brachytherapy combined with BNCT produced a biologically weighted mean dose rate of 5.2E-09, 2.3E-07, 8.7E-09 and 2.4E-09 RBE.Gy.h-1.p-1.s, respectively on the healthy tissue, on the target tumor and on the I 1 and I 2 infiltration zones. Conclusion Cf-252 brachytherapy combined with BNCT delivered a selective irradiation to the target tumor and to infiltration zones, while intracavitary balloon catheter brachytherapy with I-125 delivered negligible doses on the tumor infiltration zones.
Resumo:
Complications from central venous catheterization include infectious conditions, pneumothorax, hemothorax and venous thrombosis. Pericardial effusion with cardiac tamponade hardly occurs, and in infants is generally caused by umbilical catheterization. The authors describe the case of cardiac tamponade occurred in an infant during chest computed tomography with contrast infusion through a central venous catheter inserted into the right internal jugular vein.
Resumo:
The authors report a case of umbilical venous catheter malposition with air in the portal venous system in a preterm neonate. Initially, the hypothesis of necrotizing enterocolitis was considered, but the newborn progressed with no finding of disease and the air disappeared at follow-up radiography. The differential diagnosis of such a finding can avoid unnecessary clinical treatments.
Resumo:
Enterococcus spp bacteremia is associated with high mortality and the appearance of high-level gentamicin resistance (HLGR) created additional challenges for the treatment of these infections. We evaluated the epidemiological and clinical characteristics of patients with bacteremias caused by HLGR and non_HLGR Enterococcus faecalis isolates at a teaching hospital in the State of São Paulo, Brazil. Patients with bacteremia due to E. faecalis diagnosed between January 1999 and December 2003 were included in the study. We collected clinical, epidemiological, and microbiological data from medical records. Banked isolates were typed using pulsed-field gel electrophoresis. We identified 145 cases of E. faecalis bacteremia: 66 (45.5%) were caused by HLGR isolates and 79 (54.5%) by non_HLGR. In the univariate analysis, patients with HLGR infection were older, had higher rates of bladder catheterization, and more often had treatment with cephalosporin, quinolone, and/or carbapenem compared with patients with non_HLGR infection (P < 0.05). Multivariate analysis indicated that older age, hematological malignancy, and previous use of vancomycin were independently associated with HLGR (P < 0.05). Mortality rates were not significantly different among patients with HLGR (50%) and non_HLGR (43%) infections (P = 0.40). Of the 32 genotyped isolates, 16 were distributed into 6 main electrophoresis patterns and 16 others had distinct patterns. E. faecalis bacteremia is associated with high mortality and is frequently caused by HLGR isolates at this teaching hospital. The variability among genotyped isolates suggests that endogenous infections, rather than patient-to-patient transmission of E. faecalis, are more common at this institution.
Resumo:
The epidemiology of bacteremia developing during neutropenia has changed in the past decade, with the re-emergence of Gram-negative (GN) bacteria and the development of multidrug resistance (MDR) among GN bacteria. We conducted a case-control study in order to identify factors associated with bacteremia due to multidrug-resistant Gram-negative (MDRGN) isolates in hematopoietic stem cell transplant recipients. Ten patients with MDRGN bacteremia were compared with 44 patients with GN bacteremia without MDR. Bacteremia due to Burkholderia or Stenotrophomonas sp was excluded from analysis (3 cases), because the possibility of intrinsical resistance. Infection due to MDRGN bacteria occurred in 2.9% of 342 hematopoietic stem cell transplant recipients. Klebsiella pneumoniae was the most frequent MDRGN (4 isolates), followed by Pseudomonas aeruginosa (3 isolates). Among non-MDRGN, P. aeruginosa was the most frequent agent (34%), followed by Escherichia coli (30%). The development of GN bacteremia during the empirical treatment of febrile neutropenia (breakthrough bacteremia) was associated with MDR (P < 0.001, odds ratio = 32, 95% confidence interval = 5_190) by multivariate analysis. Bacteremia due to MDRGN bacteria was associated with a higher death rate by univariate analysis (40 vs 9%; P = 0.03). We were unable to identify risk factors on admission or at the time of the first fever, but the occurrence of breakthrough bacteremia was strongly associated with MDRGN bacteria. An immediate change in the antibiotic regimen in such circumstances may improve the prognosis of these patients.
Resumo:
Infection with Bartonella spp may cause cardiac arrhythmias, myocarditis and endocarditis in humans. The aim of the present study was to evaluate a possible association between Bartonella spp bacteremia and endocarditis, arrhythmia and Chagas cardiomyopathy in patients from Brazil and Argentina. We screened for the presence of bacterial 16S rRNA in human blood by PCR using oligonucleotides to amplify a 185-bp bacterial DNA fragment. Blood samples were taken from four groups of subjects in Brazil and Argentina: i) control patients without clinical disease, ii) patients with negative blood-culture endocarditis, iii) patients with arrhythmias, and iv) patients with chronic Chagas cardiomyopathy. PCR products were analyzed on 1.5% agarose gel to visualize the 185-bp fragment and then sequenced to confirm the identity of DNA. Sixty of 148 patients (40.5%) with cardiac disease and 1 of 56 subjects (1.8%) from the control group presented positive PCR amplification for Bartonella spp, suggesting a positive association of the bacteria with these diseases. Separate analysis of the four groups showed that the risk of a Brazilian patient with endocarditis being infected with Bartonella was 22 times higher than in the controls. In arrhythmic patients, the prevalence of infection was 45 times higher when compared to the same controls and 40 times higher for patients with Chagas cardiomyopathy. To the best of our knowledge this is the first report of the association between Bartonella spp bacteremia and Chagas disease. The present data may be useful for epidemiological and prevention studies in Brazil and Argentina.
Resumo:
Most of the knowledge of the virulence determinants of extraintestinal pathogenicEscherichia coli (ExPEC) comes from studies with human strains causing urinary tract infections and neonatal meningitis and animal strains causing avian colibacillosis. In this research, we analyzed the phylogenetic background, the presence of 20 ExPEC virulence factors, and the intrinsic virulence potential of 74 E. coli strains isolated in São Paulo, Brazil, from 74 hospitalized patients (43 males and 31 females) with unknown-source bacteremia. Unlike other places in the world, the bacteremic strains originated equally from phylogroups B2 (35%) and D (30%). A great variability in the profiles of virulence factors was noted in this survey. Nevertheless, 61% of the strains were classified as ExPEC, meaning that they possessed intrinsic virulent potential. Accordingly, these strains presented high virulence factor scores (average of 8.7), and were positively associated with 12 of 17 virulence factors detected. On the contrary, the non-ExPEC strains, isolated from 39% of the patients, presented a generally low virulence capacity (medium virulence factor score of 3.1), and were positively associated with only the colicin cvaC gene. These results show the importance of discriminating E. coli isolates that possess characteristics of true pathogens from those that may be merely opportunistic in order to better understand the virulence mechanisms involved in extraintestinalE. coli infections. Such knowledge is essential for epidemiological purposes as well as for development of control measures aimed to minimize the incidence of these life-threatening and costly infections.
Resumo:
Contact force (CF) sensing technology allows real-time monitoring during catheter ablation for atrial fibrillation (AF). However, the effect of CF sensing technology on procedural parameters and clinical outcomes still needs clarification. Because of the inconsistent results thus far in this area, we performed a meta-analysis to determine whether CF sensing technology can improve procedural parameters and clinical outcomes for the treatment of AF. Studies examining the benefits of CF sensing technology were identified in English-language articles by searching the MEDLINE, Web of Science, and Cochrane Library databases (inception to May 2015). Ten randomized, controlled trials involving 1834 patients (1263 males, 571 females) were included in the meta-analysis (681 in the CF group, 1153 in the control group). Overall, the ablation time was significantly decreased by 7.34 min (95%CI=-12.21 to -2.46; P=0.003, Z test) in the CF group compared with the control group. CF sensing technology was associated with significantly improved freedom from AF after 12 months (OR=1.55, 95%CI=1.20 to 1.99; P=0.0007) and complications were significantly lower in the CF group than in the control group (OR=0.50, 95%CI=0.29 to 0.87; P=0.01). However, fluoroscopy time analysis showed no significantly decreased trend associated with CF-guided catheter ablation (weighted mean difference: -2.59; 95%CI=-9.06 to 3.88; P=0.43). The present meta-analysis shows improvement in ablation time and freedom from AF after 12 months in AF patients treated with CF-guided catheter ablation. However, CF-guided catheter ablation does not decrease fluoroscopy time.