96 resultados para UV-VIS spectrophotometry


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple experiment for the preparation of transparent conducting glass electrodes by deposition of pure and fluorine doped SnO2 films is described. This procedure was tested in the undergraduate inorganic course at IQ-UNICAMP. The success in achieving a conducting layer was easily checked using the standard probes of a volt-ohm meter. The optical transmittance and thickness were studied by UV-vis spectrophotometry. To discuss the experimental results we place significant emphasis on molecular orbital and energy band model theories. The undergraduate students can also discuss the concepts related to the electronic properties of solids and to interesting new materials, such as transparent conducting films, which are the subject of significant current research and technological applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tiquira is a traditional homemade alcoholic distillate produced in the Maranhão State (Brazil), gotten from cassava (Manihot esculenta, Crantz.). It can be normally found on street markets. Due to the addition of tangerine leaves, the original tiquira has a bluish color. Samples of this beverage were acquired in the local trade and analyzed from the spectroanalytical point of view. The results indicated that these drinks had been adulterated by the addition of crystal violet, a potencialy hazardous compound. The identification and quantification of crystal violet in 10 spiked samples was accomplished by UV-Vis spectrophotometry through the standard addition method. In order to verify the efficiency of the proposed method, experiments on the quantification and recovery were carried out and the results indicated a content of crystal violet in the 10-6 to 10-7 mol L-1 range.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

TiO2 thin films were prepared by the sol-gel method using different acids (HCl and HAc), with a parallel evaluation of the gel ageing effects on the film properties. After the thermal treatments, the resulting materials were characterized through gravimetric analysis, UV-VIS spectrophotometry (from which optical parameters such as band gap was derived), XRD, morphological surface analysis (AFM) and photocatalytic activity. The majority of the obtained thin films parameters were similar independent of the acid type and the ageing time of the gel. Nevertheless, a visible effect of the surface morphology properties on the films and their photocatalytic activity was observed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple analytical method for extraction and quantification of lutein colorant added to yogurt was developed and validated. The method allowed complete extraction of carotenoids using tetrahydrofuran in vortex, followed by centrifugation, partition to diethyl ether/petroleum ether, and drying. The carotenoids dissolved in ethanol were quantified by UV-Vis spectrophotometry. This method showed linearity in the range tested (1.41-13.42 µg g-1), limits of detection and quantification of 0.42 and 1.28 µg g-1, respectively, low relative standard deviation (3.4%) and recovery ranging from 95 to 103%. The method proved reliable for quantification of lutein added to yogurt.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work aimed to adapt the analysis of methemoglobin recommended by Evelyn - Malloy (visible spectrophotometry), in order to facilitate its application in the field, or to analysis in clinical laboratory, of existing sites of diflubenzuron application. The parameters changed included: centrifuge rotation speed; time between the collection of biological sample and analysis, and storage temperature of the samples; and the volume of reagents. The comparison of the rotation speed (rpm) of the reference methodology with the rpm of a "clinical centrifuge" did not reveal a statistically significant difference in the levels of methemoglobin. The time between the collection of biological sample and analysis was extended for a period of up to 48 hours for both conservation by refrigeration and ambient temperature, producing no statistically significant difference when compared to the standard duration of 2 hours. Regarding the reagents, the reference methodology already uses the volume necessary to ensure complete reaction, whereas a wider range from the recommended volume to a 5-fold reduction in comparison to the reference methodology could be used. It was concluded that the proposed changes to the methodology for adapting the analysis are applicable to studies of field / workplace exposure and ensure the reliability of results. The adapted methodology was inter-laboratory validated and the parameters changed can be selected according to the requirements of the laboratory at which the methemoglobin is to be measured.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The application of multivariate calibration techniques to multicomponent analysis by UV-VIS molecular absorption spectrometry is a powerful tool for simultaneous determination of several chemical species. However, when this methodology is accomplished manually, it is slow and laborious, consumes high amounts of reagents and samples, is susceptible to contaminations and presents a high operational cost. To overcome these drawbacks, a flow-batch analyser is proposed in this work. This analyser was developed for automatic preparation of standard calibration and test (or validation) mixtures. It was applied to the simultaneous determination of Cu2+, Mn2+ and Zn2+ in polyvitaminic and polymineral pharmaceutical formulations, using 4-(2-piridilazo) resorcinol as reagent and a UV-VIS spectrophotometer with a photodiode array detector. The results obtained with the proposed system are in good agreement with those obtained by flame atomic absorption spectrometry, which was employed as reference method. With the proposed analyser, the preparation of calibration and test mixtures can be accomplished about four hours, while the manual procedure requires at least two days. Moreover, it consumes smaller amounts of reagents and samples than the manual procedure. After the preparation of calibration and test mixtures, 60 samples h-1 can be carried out with the proposed flow-batch analyser.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Residual fibers from palm oil production are a good source of carotene, since they contain more than 5% of the original oil, with about 5000 ppm of carotenoids. As carotenoids are thermosensitive molecules, supercritical CO2 can be used for oil recovery, because this technique employs low temperatures. In this work results of oil extraction experiments from pressed palm oil fibers are shown. Fibers were from AGROPALMA, an industry which is located in Tailândia (Pará, Brazil). Extractions were carried out at 200, 250 and 300 bar and at temperatures of 45 and 55oC. Oil was analyzed by UV/vis spectrophotometry for total carotene determination. Results showed a large increase in extraction rate from 200 to 250 bar and a small variation from 250 to 300 bar. The total amount of carotenes did not increase in the course of extraction at 300 bar, but it showed a large increase at 200 and at 250 bar. Free fatty acids are present in amounts larger than those found in commercial oils.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study describes the validation of UV spectrophotometric method for quantitative determination of gemifloxacin mesylate (GFM) in tablets using methanol as solvent. The method was specific, linear, precise, exact and robust at 272 and 343 nm. The results confirmed that the method in both wavelengths is valid and useful to the routine quality control of GFM in coated tablets. The validate method was compared to liquid chromatography (HPLC), microbiological assay and visible (VIS) spectrophotometry, which were previously developed and validated to the same drug. There was not significative difference between the methods for GFM quantitation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The determination of fractal dimension (D) of humic particles was achieved by the turbidimetric technique where diluted suspensions of humic acids, in different experimental conditions, were analyzed by spectrophotometry UV-Vis. The slope of the lines (beta) was taken from the graphics (logtauvs loglambda) to obtain D. The results show that the values of D changed according to pH (3.0, 5.0 and 7.0), temperature (25 and 5 ºC) and shaking (magnetic and horizontal). In general, the value of D decreased with the increment of pH, increase of shaking and decrease of temperature.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

These films were obtained by dip coating. Parameters like dislocation velocity; number of deposits, suspension concentration, and number of deposits followed or not by heat treatment between each deposit and calcination temperature were evaluated for establishing the best homogeneity. The obtained films were characterized in terms of their morphology, optical quality and photoluminescence by scanning electron microscopy (SEM), UV-vis absorption spectrophotometry and luminescence spectroscopy, respectively. The morphologic and luminescent characteristics showed dip coating as good laboratory technique for development of thin films for optical applications.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this work, a partial least squares regression routine was used to develop a multivariate calibration model to predict the chemical oxygen demand (COD) in substrates of environmental relevance (paper effluents and landfill leachates) from UV-Vis spectral data. The calibration models permit the fast determination of the COD with typical relative errors lower by 10% with respect to the conventional methodology.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The present work purposes the preparation of a silica gel sorbent organically modified with 2-aminoethyl-3-aminobutylmethyldimethoxysilane (AAMDMS) and imprinted with Cu2+ ions by means surface imprinting technique and its use for selective on-line sorbent preconcentration of Cu2+ ions with further UV-VIS spectrophotometric determination by flow injection analysis. The Cu2+-imprinted silica gel, when compared with non imprinted silica gel and silica gel, showed from the binary mixture of Cu2+/Ni2+ relative selectivity coefficient (k') of 6.84 and 5.43 and 6.64 and 19.83 for the mixture Cu2+/Pb2+, thus demonstrating higher selectivity of Cu2+-imprinted silica gel towards Cu2+ ions. Under optimized condition, the on-line preconcentration method provided detection limit of 3.4 μg L-1 and linear range ranging from 30.0 up to 300.0 μg L-1 (r = 0.995). The accuracy of method was successfully assessed by analyzing different kind of spiked water samples with recovery values ranging from 92.2 up to 103.0%.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Interest in analytical methods for quality control of herbal drugs has grown sharply due to the scarcity of monographs in official manuals. Thus, the aim of the present study was to evaluate analytical procedures for quantitative determination of flavonoids from leaves of Bauhinia forficata Link (pata-de-vaca). Two procedures for quantification of total flavonoids (with and without acid hydrolysis) by spectrophotometry were tested. The proposed methods proved to be specific, sensitive, precise, accurate and robust, being suitable for routine laboratory use.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An experiment was proposed applying the Chemometric approach of Multivariate Analysis for inclusion in undergraduate Chemistry courses to promote and expand the use of this analytical-statistical tool. The experiment entails the determination of the acid dissociation constant of dyes via UV-Vis electronic spectrophotometry. The dyes used show from simple equilibrium to very complex systems involving up to four protolytic species with high spectral overlap. The Chemometric methodology was more efficient than univariate methods. For use in classes, it is up to the teacher to decide which systems should be utilized given the time constraints and laboratory conditions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Drug trafficking and the introduction of new drugs onto the illicit market are one of the main challenges of the forensic community. In this study, the chemical profile of a new designer drug, 2-(4-iodine-2,5-dimethoxyphenyl)-n-[(2-methoxyphenyl)methyl]etamine or 25I-NBOMe was explored using thin layer chromatography (TLC), ultraviolet-visible spectrophotometry (UV-Vis), attenuated total reflection with Fourier transform infrared spectroscopy(ATR-FTIR), gas chromatography mass spectrometry (GC-MS) and electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FT-ICR MS). First, the TLC technique was effective for identifying spots related to 25C-, 25B- and 25I-NBOMe compounds, all with the same retention factor, Rf ≈ 0.50. No spot was detected for 2,5-dimethoxy-4-bromoamphetamine, 2,5-Dimethoxy-4-chloroamphetamine or lysergic acid diethylamide compounds. ATR-FTIR preserved the physical-chemical properties of the material, whereas GC-MS and ESI-MS showed better analytical selectivity. ESI(+)FT-ICR MS was used to identify the exact mass (m/z428.1706 for the [M + H]+ ion), molecular formula (M = C18H22INO3), degree of unsaturation (DBE = 8) and the chemical structure (from collision induced dissociation, CID, experiments) of the 25I-NBOMe compound. Furthermore, the ATR-FTIR and CID results suggested the presence of isomers, where a second structure is proposed as an isomer of the 25I-NBOMe molecule.