33 resultados para Teaching performance on-line


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A liquid chromatography-tandem mass spectrometry method with atmospheric pressure chemical ionization (LC-APCI/MS/MS) was validated for the determination of etoricoxib in human plasma using antipyrin as internal standard, followed by on-line solid-phase extraction. The method was performed on a Luna C18 column and the mobile phase consisted of acetonitrile:water (95:5, v/v)/ammonium acetate (pH 4.0; 10 mM), run at a flow rate of 0.6 mL/min. The method was linear in the range of 1-5000 ng/mL (r²>0.99). The lower limit of quantitation was 1 ng/mL. The recoveries were within 93.72-96.18%. Moreover, method validation demonstrated acceptable results for the precision, accuracy and stability studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and sensitive on-line flow injection system for determination of zinc with FAAS has been described. The method is based on the separation and preconcentration of zinc on a microcolumn of immobilized Alizarin Red S on alumina. The adsorbed analyte is then eluted with 250 µL of nitric acid (1 mol L-1) and is transported to flame atomic absorption spectrometer for quantification. The effect of pH, sample and eluent flow rates and presence of various cations and anions on the retention of zinc was investigated. The sorption of zinc was quantitative in the pH range of 5.5-8.5. For a sample volume of 25 mL an enrichment factor of 144 and a detection limit (3S) of 0.2 µg L-1 was obtained. The precision (RSD, n=7) was 3.0% at the 20 µg L-1 level. The developed system was successfully applied to the determination of zinc in water samples, hair, urine and saliva.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present work purposes the preparation of a silica gel sorbent organically modified with 2-aminoethyl-3-aminobutylmethyldimethoxysilane (AAMDMS) and imprinted with Cu2+ ions by means surface imprinting technique and its use for selective on-line sorbent preconcentration of Cu2+ ions with further UV-VIS spectrophotometric determination by flow injection analysis. The Cu2+-imprinted silica gel, when compared with non imprinted silica gel and silica gel, showed from the binary mixture of Cu2+/Ni2+ relative selectivity coefficient (k') of 6.84 and 5.43 and 6.64 and 19.83 for the mixture Cu2+/Pb2+, thus demonstrating higher selectivity of Cu2+-imprinted silica gel towards Cu2+ ions. Under optimized condition, the on-line preconcentration method provided detection limit of 3.4 μg L-1 and linear range ranging from 30.0 up to 300.0 μg L-1 (r = 0.995). The accuracy of method was successfully assessed by analyzing different kind of spiked water samples with recovery values ranging from 92.2 up to 103.0%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A portable microcontrolled system is proposed to monitor conductivity, temperature and pH in on-line, in situ and remote way from a water reservoir faraway 200 m. The system comprises two modules: one for data reception (located in laboratory) and another for data acquisition/transmission (located near water reservoir). It uses a microcontroller and a transceiver to remote data transmission/reception by radio frequency. Variations of water parameters were simultaneously monitored without interruption during a period of ten hours with a relative error about 4.0 %. The developed system showed simple, stable, accurate, robust and low-cost to determine parameters of water in field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Foi testar a validade e a confiabilidade de uma versão on-line do Female Sexual Function Index (FSFI). MÉTODOS: Uma versão on-line do FSFI foi comparada à versão tradicional, em papel. Para tanto, estudantes de Fisioterapia de três cidades foram alocadas randomicamente em dois grupos - G-pp/ol (n=126) e G-ol/pp (n=147). As mulheres do G-pp/ol responderam ao FSFI do modo tradicional, em papel e caneta, enquanto o G-ol/pp respondeu a uma versão on-line do mesmo questionário. Após 15 dias de intervalo, houve nova coleta, quando o G-pp/ol respondeu a versão on-line enquanto o G-ol/pp respondeu no papel. Todos os dados foram transportados para o software estatístico SPSS. Diferenças demográficas entre os dois grupos foram reveladas pelo teste t de Student ou pelo teste exato de Fischer (IC95%; p>0,05). A associação e a correlação entre as respostas entre G-pp/ol e G-ol/pp durante cada coleta foram acessadas pelo teste t e o coeficiente de Pearson. Estratégia idêntica foi utilizada para as comparações intragrupo. RESULTADOS: Um total de 273 mulheres participou do estudo e 28 (10,2%) desistiram da segunda coleta. Não houve diferenças demográficas entre os grupos. Houve associação entre 15 das 19 questões do FSFI entre os dois grupos, tanto no teste quanto no reteste. A análise intragrupo revelou que todas as questões e os escores do FSFI estiveram associados, mas fracamente correlacionados para um mesmo grupo durante as duas coletas. CONCLUSÃO: A versão on-line do FSFI apresentou validade e confiabilidade aceitáveis quando comparada à versão em papel, o que pode justificar a opção por essa modalidade, especialmente em estudos envolvendo sexualidade.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Drug-resistant tuberculosis (TB) threatens global TB control and is a major public health concern in several countries. We therefore developed a multiplex assay (LINE-TB/MDR) that is able to identify the most frequent mutations related to rifampicin (RMP) and isoniazid (INH) resistance. The assay is based on multiplex polymerase chain reaction, membrane hybridisation and colorimetric detection targeting of rpoB and katG genes, as well as the inhA promoter, which are all known to carry specific mutations associated with multidrug-resistant TB (MDR-TB). The assay was validated on a reference panel of 108 M. tuberculosis isolates that were characterised by the proportion method and by DNA sequencing of the targets. When comparing the performance of LINE-TB/MDR with DNA sequencing, the sensitivity, specificity and agreement were 100%, 100% and 100%, respectively, for RMP and 77.6%, 90.6% and 88.9%, respectively, for INH. Using drug sensibility testing as a reference standard, the performance of LINE-TB/MDR regarding sensitivity, specificity and agreement was 100%, 100% and 100% (95%), respectively, for RMP and 77%, 100% and 88.7% (82.2-95.1), respectively, for INH. LINE-TB/MDR was compared with GenoType MTBDRplus for 65 isolates, resulting in an agreement of 93.6% (86.7-97.5) for RIF and 87.4% (84.3-96.2) for INH. LINE-TB/MDR warrants further clinical validation and may be an affordable alternative for MDR-TB diagnosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pattern of attack of a galling insect reveals an unexpected preference-performance linkage on medium-sized resources. The Plant Vigor Hypothesis (PVH) predicts oviposition preference and higher offspring performance on longer and fast-growing shoots, and although several studies have tested its predictions, long-term studies concerning the patterns of host selection by galling species are still lacking. The PVH was tested in this study using Bauhinia brevipes (Fabaceae) as the host of a leaf gall midge, Asphondylia microcapillata (Diptera, Cecidomyiidae) during three consecutive years. Shoots were collected from the same 80 plants between 2001 and 2003 and shoot length, number of healthy and galled leaves, gall number, and mortality factors were recorded. Nearly 600 galls were found on the 5,800 shoots collected. Medium-sized shoots supported from 46 to 70% of all galls, with greater gall survival rate in 2002 and 2003. A decrease in parasitism rate coupled with an increase in gall predation lead to a constant similar gall survivorship rate in all years (x = 22.7%). Although gall abundance varied among years (122 in 2001, 114 in 2002 and 359 in 2003) preference for longer shoots was not observed because the percentage of galled shoots and galled leaves were higher on medium shoot length classes in all years. The observed distribution of gall abundance and galled shoots were always greater than the expected distribution on medium shoot length classes. These findings do not support the PVH, and show that A. microcapillata can maximize the female preference and larval performance on medium-sized shoots of B. brevipes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Academic evaluation has been an essential component of modern science since its inception, as science has moved away from personalized patronage toward its contemporary role as an essential enterprise of contemporary, democratic societies. In recent years, Brazil has experienced sustained growth in its scientific output, which is nowadays fully compatible with its status as a high middle-income country striving to become a fully developed, more equitable country in the years to come. Growth usually takes place amidst challenges and dilemmas and, in Brazil as elsewhere, academic evaluation is not exempt from such difficulties. In a large, profoundly heterogeneous country with a national evaluation system and nationwide on-line platforms disseminating information on the most disparate fields of knowledge, the main challenges refer to how to pay attention to detail without losing sight of comprehensiveness and how to handle social and regional diversity while preserving academic excellence as the fundamental benchmark.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Long pepper (Piper hispidinervum) is an Amazonian species of commercial interest due to the production of safrole. Drying long pepper biomass to extract safrole is a time consuming and costly process that can also result in the contamination of the material by microorganisms. The objective of this study was to analyze the yield of essential oil and safrole content of fresh and dried biomass of long pepper accessions maintained in the Active Germoplasm Bank of Embrapa Acre, in the state of Acre, Brazil, aiming at selecting genotypes with best performance on fresh biomass to recommend to the breeding program of the species. Yield of essential oil and safrole content were assessed in 15 long pepper accessions. The essential oil extraction was performed by hydrodistillation and analyzed by gas chromatography. A joint analysis of experiments was performed and the means of essential oil yield and safrole content for each biomass were compared by Student's t-test. There was variability in the essential oil yield and safrole content. There was no difference between the types of biomass for oil yield; however to the safrole content there was difference. Populations 9, 10, 12 and 15 had values of oil yield between 4.1 and 5.3%, and safrole content between 87.2 and 94.3%. The drying process does not interfere in oil productivity. These populations have potential for selection to the long pepper breeding program using oil extraction in the fresh biomass

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Neuroimaging studies suggest that obese people might show hyperactivity of brain areas regarding reward processing, and hypoactivity of brain areas concerning cognitive control, when exposed to food cues. Although the effects of bariatric surgery on the central nervous system and eating behavior are well known, few studies have used neuroimage techniques with the aim of investigating the central effects of bariatric surgery in humans. OBJECTIVES: This paper systematically and critically reviews studies using functional neuroimaging to investigate changes on the patterns of activation of central areas related to the regulation of eating behavior after bariatric surgery. METHOD: A search on the databases Medline, Web of Science, Lilacs and Science Direct on Line, was conducted in February 2013, using the keywords "Neuroimaging", "Positron-Emission Tomography", "Magnetic Resonance Imaging", "Gastric Bypass", "Gastroplasty", "Jejunoileal Bypass", "Bariatric Surgery". RESULTS: Seven manuscripts were included; the great majority studied the central effects of Roux en Y gastric bypass, using positron emission tomography or functional magnetic resonance. CONCLUSIONS: Bariatric surgery might normalize the activity of central areas concerned with reward and incentive salience processing, as the nucleus accumbens and mesencephalic tegmental ventral area, as well as circuitries processing behavioral inhibition, as the dorsolateral prefrontal cortex.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An automatic dispenser based on a flow-injection system used to introduce sample and analytical solution into an inductively coupled plasma mass spectrometer through a spray chamber is proposed. Analytical curves were constructed after the injection of 20 to 750 µL aliquots of a multielement standard solution (20.0 µg L-1 in Li, Be, Al, V, Cr, Mn, Ni, Co, Cu, Zn, As, Se, Sr, Ag, Cd, Ba, Tl, Pb) and the acquisition of the integrated transient signals. The linear concentration range could be extended to ca. five decades. The performance of the system was checked by analyzing a NIST 1643d reference material. Accuracy could be improved by the proper selection of the injected volume. Besides good precision (r.s.d. < 2%), the results obtained with the proposed procedure were closer to the certified values of the reference material than those obtained by direct aspiration or by injecting 125 µL of several analytical solutions and samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A on-line thermostatization system that use simples materials, for flow injection and continuous flow analysis is described. The proposed system showed good performance between 10 to 40ºC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An on-line electrodissolution procedure implemented in a flow injection system for determination of copper, zinc and lead in brasses alloys by ICP-AES is described. Sample dissolution procedure was carried out by using a PTFE chamber and a DC power supply with constant current. Solid sample was attached to chamber as anode and a gold tubing coupled in the chamber was used as cathode. An electrolytic solution flowing through the gold tubing closed the electric circuit with sample, in order to provide condition for electric dissolution when the DC power supply was switched on. The best results were achieved by using a 1.5 mol l-1 nitric acid solution as electrolyte and a 2.5 A current intensity. The procedure presented a good performance characterized by a relative standard deviation better than < 5% (n=5) and a sample throughput of 180 determinations per hour for Cu, Zn and Pb. Results were in agreement with those obtained by conventional acid dissolution (99% confidence level).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Different methods have been applied to solve special problems of metal analysis. First, the solid samples of tool steels were analyzed by X-ray fluorescence. Alternatively, an on-line electrodissolution implemented in a flow injection system and conventional dissolution procedure for determination of W, Mo, V and Cr in tool steels by ICP-AES is described. The resulting analyte solutions were compared with conventional dissolution procedure and determination by ICP-AES. The electrolytic procedure presented a good performance characterized by a sample throughput of 164 determinations per hour. Results were in agreement with those obtained by conventional acid dissolution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new solid phase microextraction (SPME) system, known as in-tube SPME, was recently developed using an open tubular fused-silica capilary column, instead of an SPME fiber, as the SPME device. On-line in-tube SPME is usually used in combination with high performance liquid chromatography. Drugs in biological samples are directly extracted and concentrated in the stationary phase of capillary columns by repeated draw/eject cycles of sample solution, and then directly transferred to the liquid chromatographic column. In-tube SPME is suitable for automation. Automated sample handling procedures not only shorten the total analysis time, but also usually provide better accuracy and precision relative to manual techniques. In-tube SPME has been demonstrated to be a very effective and highly sensitive technique to determine drugs in biological samples for various purposes such as therapeutic drug monitoring, clinical toxicology, bioavailability and pharmacokinetics.