99 resultados para Swan-Ganz catheter
Resumo:
OBJECTIVE: To identify useful clinical characteristics for selecting patients eligible for mapping and ablation of atrial fibrillation. METHODS: We studied 9 patients with atrial fibrillation, without structural heart disease, associated with: 1) antiarrhythmic drugs, 2) symptoms of low cardiac output, and 3) intention to treat. Seven patients had paroxysmal atrial fibrillation and 2 had recurrent atrial fibrillation. RESULTS: In the 6 patients who underwent mapping (all had paroxysmal atrial fibrillation), catheter ablation was successfully carried out in superior pulmonary veins in 5 patients (the first 3 in the left superior pulmonary vein and the last 2 in the right superior pulmonary vein). One patient experienced a recurrence of atrial fibrillation after 10 days. We observed that patients who had short episodes of atrial fibrillation on 24-hour Holter monitoring before the procedure were those in whom mapping the focus of tachycardia was possible. Tachycardia was successfully suppressed in 4 of 6 patients. The cause of failure was due to the impossibility of maintaining sinus rhythm long enough for efficient mapping. CONCLUSION: Patients experiencing short episodes of atrial fibrillation during 24-hour Holter monitoring were the most eligible for mapping and ablation, with a final success rate of 66%, versus the global success rate of 44%. Patients with persistent atrial fibrillation were not good candidates for focal ablation.
Resumo:
OBJECTIVE: To determine whether recording of the activation potential may be used as an isolated criterion to guide catheter ablation of atriofascicular Mahaim fibers. METHODS: We studied 6 patients (5 females, mean age of 26±7.3 years) with paroxysmal tachycardias with a wide QRS complex, whose electrophysiological study diagnosed atriofascicular Mahaim fibers. Mapping and catheter ablation were performed in sinus rhythm, guided only by the recording of the activation potential of the fiber. RESULTS: Efficacy in ablation was achieved in all patients. The fibers were located in the right lateral region of the tricuspid ring in 3 patients, right posterolateral region in 2, and right anterolateral region in 1. A mean of 5.3±3 radiofrequency applications was performed. The mean fluoroscopy time was 46.6±25 minutes, and the mean duration of the procedure was 178.6±108 minutes. No complication occurred. In a mean 20-month follow-up, all patients were asymptomatic and receiving no antiarrhythmic drugs. CONCLUSION: Catheter ablation of Mahaim fibers may be performed with good safety and efficacy by mapping the activation potential of the tricuspid ring in sinus rhythm.
Resumo:
OBJECTIVE: To report short and midtem follow-up results of balloon aortic valvuloplasty to treat congenital aortic stenosis. METHODS: Seventy-five patients (median age: 8 years) underwent the procedure through the retrograde femoral or carotid route. RESULTS: The procedure was completed in 74 patients (98.6%). The peak-to-peak systolic gradient dropped from 79.6±27.7 to 22.3±17.8 mmHg (P<0.001), the left ventricular systolic pressure dropped from 164±39.1 to 110±24.8 mmHg (P<0.001), and the left ventricular end diastolic pressure dropped from 13.3±5.5 to 8.5±8.3 mmHg (P< 0.01). Four patients (5.3%) died due to the procedure. Aortic regurgitation (AoR) appeared or worsened in 27/71 (38%) patients, and no immediate surgical intervention was required. A mean follow-up of 50±38 months was obtained in 37 patients. Restenosis and significant AoR were observed in 16.6% of the patients. The estimates for being restenosis-free and for having significant AoR in 90 months were 60% and 50%, respectively. CONCLUSION: Aortic valvuloplasty was considered the initial palliative method of choice in managing congenital aortic stenosis, with satisfactory short- and midterm results.
Resumo:
Abstract OBJECTIVE To evaluate the incidence of complications related to the use of peripheral intravenous catheter in neonates and identify the associated risk factors. METHOD Prospective cohort study conducted in a Neonatal Intensive Care Unit. Participants were the hospitalized neonates undergoing peripheral intravenous puncture in the period from February to June 2013. RESULTS The incidence of complications was 63.15%, being infiltration/extravasation (69.89%), phlebitis (17.84%) and obstruction (12.27%). The risk factors were the presence of infection (p = 0.0192) and weight at the puncture day (p = 0.0093), type of intermittent infusion associated with continuous infusion (p <0.0001), endotracheal intubation (p = 0.0008), infusion of basic plan (p = 0.0027), total parenteral nutrition (P = 0.0002), blood transfusion associated with other infusions (p = 0.0003) and other drugs (p = 0.0004). Higher risk of developing complications in the first 48 hours after puncture. CONCLUSION A high rate of complications related to the use of peripheral intravenous catheter, and risk factors associated with infection, weight, drugs and infused solutions, and type of infusion.
Resumo:
Objective Comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and Methods Simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT were performed with the MCNP5 code, modeling the treatment of a brain tumor on a voxel computational phantom representing a human head. Absorbed dose rates were converted into biologically weighted dose rates. Results Intracavitary balloon catheter brachytherapy with I-125 produced biologically weighted mean dose rates of 3.2E-11, 1.3E-10, 1.9E-11 and 6.9E-13 RBE.Gy.h-1.p-1.s, respectively, on the healthy tissue, on the balloon periphery and on the I 1 and I 2 tumor infiltration zones. On the other hand, Cf-252 brachytherapy combined with BNCT produced a biologically weighted mean dose rate of 5.2E-09, 2.3E-07, 8.7E-09 and 2.4E-09 RBE.Gy.h-1.p-1.s, respectively on the healthy tissue, on the target tumor and on the I 1 and I 2 infiltration zones. Conclusion Cf-252 brachytherapy combined with BNCT delivered a selective irradiation to the target tumor and to infiltration zones, while intracavitary balloon catheter brachytherapy with I-125 delivered negligible doses on the tumor infiltration zones.
Resumo:
Complications from central venous catheterization include infectious conditions, pneumothorax, hemothorax and venous thrombosis. Pericardial effusion with cardiac tamponade hardly occurs, and in infants is generally caused by umbilical catheterization. The authors describe the case of cardiac tamponade occurred in an infant during chest computed tomography with contrast infusion through a central venous catheter inserted into the right internal jugular vein.
Resumo:
The authors report a case of umbilical venous catheter malposition with air in the portal venous system in a preterm neonate. Initially, the hypothesis of necrotizing enterocolitis was considered, but the newborn progressed with no finding of disease and the air disappeared at follow-up radiography. The differential diagnosis of such a finding can avoid unnecessary clinical treatments.
Resumo:
Conyza spp. are widely responsible for yield losses in agriculture due to its worldwide occurrence, resistance to herbicides and other traits which turn these species into first grade weeds. Since the 1980's, these species started to be cited on books both related to the ecology and the weed science, being usually classified as ruderals. Occurrence of Conyza in crops shows that these species are highly adaptable due to its recent evolutionary origin and occur in environments prone concomitantly to a moderate set of competition, disturbance and stress. There are also limitations in Grime's theory which may lead us to mistakes about the behavior of Conyza. Thus, simple and isolated recommendations certainly will not solve the problem of Conyza. Neither soil tillage nor tolerant crops to 2,4-D will free the agriculture from this weed, being necessary an integrated approach to solve this problem which demands qualified human resources in weed science and planning.
Resumo:
This study reviewed the use of the Strengths and Weaknesses of Attention-Deficit/Hyperactivity-symptoms and Normal-behaviors (SWAN) rating scale in diagnostic and evolutive approaches to attention deficit hyperactivity disorder (ADHD) and in correlational studies of the disorder. A review of articles published in indexed journals from electronic databases was conducted and 61 articles on the SWAN scale were analyzed. From these, 27 were selected to a) examine use of SWAN in research on attention disorders and b) verify evidence of its usefulness in the areas of genetics, neuropsychology, diagnostics, psychiatric comorbidities, neuroimaging, pharmacotherapy, and to examine its statistical reliability and validity in studies of diverse populations. This review of articles indicated a growing use of the SWAN scale for diagnostic purposes, for therapy, and in research on areas other than ADHD, especially when compared with other reliable scales. Use of the scale in ADHD diagnosis requires further statistical testing to define its psychometric properties.
Resumo:
Contact force (CF) sensing technology allows real-time monitoring during catheter ablation for atrial fibrillation (AF). However, the effect of CF sensing technology on procedural parameters and clinical outcomes still needs clarification. Because of the inconsistent results thus far in this area, we performed a meta-analysis to determine whether CF sensing technology can improve procedural parameters and clinical outcomes for the treatment of AF. Studies examining the benefits of CF sensing technology were identified in English-language articles by searching the MEDLINE, Web of Science, and Cochrane Library databases (inception to May 2015). Ten randomized, controlled trials involving 1834 patients (1263 males, 571 females) were included in the meta-analysis (681 in the CF group, 1153 in the control group). Overall, the ablation time was significantly decreased by 7.34 min (95%CI=-12.21 to -2.46; P=0.003, Z test) in the CF group compared with the control group. CF sensing technology was associated with significantly improved freedom from AF after 12 months (OR=1.55, 95%CI=1.20 to 1.99; P=0.0007) and complications were significantly lower in the CF group than in the control group (OR=0.50, 95%CI=0.29 to 0.87; P=0.01). However, fluoroscopy time analysis showed no significantly decreased trend associated with CF-guided catheter ablation (weighted mean difference: -2.59; 95%CI=-9.06 to 3.88; P=0.43). The present meta-analysis shows improvement in ablation time and freedom from AF after 12 months in AF patients treated with CF-guided catheter ablation. However, CF-guided catheter ablation does not decrease fluoroscopy time.
Resumo:
Há vários aspectos controversos no tratamento da paralisia facial traumática. Um destes é a natureza precisa da intervenção cirúrgica a ser usada, uma vez que a decisão de ser realizada tenha sido feita. FORMA DE ESTUDO: Clínico retrospectivo. OBJETIVOS E MÉTODOS: Entre o período de junho de 1984 e junho de 1993, 220 casos de paralisia facial traumática com boa função coclear foram tratados na Universidade de São Paulo pela seguinte técnica cirúrgica: descompressão dos segmentos mastóideo e timpânico através do acesso transmastoídeo e descompressão do gânglio geniculado e dos 50% distais do segmento labiríntico, usando-se o acesso pela fossa média. Apresentamos uma revisão de literatura e a discussão e resultados de nosso trabalho.
Resumo:
Pacientes com zumbido e audiometria normal constituem um grupo importante, pois seus achados não sofrem influência da perda auditiva. Apesar disso, este grupo é pouco estudado e não sabemos se suas características clínicas e repercussões são semelhantes às dos indivíduos com perda auditiva. OBJETIVOS: Comparar as características clínicas do zumbido e sua interferência nas atividades diárias em pacientes com e sem perda auditiva. FORMA DE ESTUDO: coorte histórica. MATERIAL E MÉTODO: Entre 744 pacientes atendidos no Grupo de Pesquisa em Zumbido do HCFMUSP, avaliou-se retrospectivamente com um corte transversal os 55 indivíduos com audiometria tonal normal. O grupo controle correspondeu a 198 pacientes com zumbido e perda auditiva atendidos sob o mesmo protocolo. Analisou-se os dados dos pacientes, as características clínicas do zumbido e sua repercussão na vida do paciente. RESULTADOS: A idade média no grupo de estudo (43,1 ± 13,4 anos) foi significantemente menor do que a do grupo controle (49,9 ± 14,5 anos). Em ambos os grupos houve predomínio do sexo feminino e o zumbido foi predominantemente bilateral, único e constante, porém sem diferença entre os grupos. A interferência na concentração e no equilíbrio emocional foi significantemente menor no grupo de estudo (25,5% e 36,4%) do que no controle (46% e 61,6%), porém sem diferença quanto à interferência no sono e na atividade social. CONCLUSÕES: O grupo de pacientes com zumbido e audição normal apresentou características clínicas semelhantes em relação ao grupo com perda auditiva. Entretanto, a faixa etária acometida e a interferência sobre a concentração e o equilíbrio emocional foram significantemente menores nestes.
Resumo:
INTRODUÇÃO: A função do trato olivococlear medial é estudada pela supressão das emissões otoacústicas com o uso de uma estimulação contralateral e sofre influência da lateralidade do sistema nervoso central, não apresentando respostas iguais entre as orelhas. Uma disfunção neste trato pode implicar na geração do zumbido, porém isto ainda não foi confirmado. OBJETIVO: Estudar a supressão das emissões otoacústicas por produto de distorção em indivíduos com zumbido. MATERIAL E MÉTODO: Estudo caso-controle com 44 pessoas com zumbido, matriculadas no Ambulatório de Zumbido da Divisão de Clínica Otorrinolaringológica do Hospital das Clínicas da Universidade de São Paulo e 44 voluntários submetidos à emissão otoacústica por produto de distorção com e sem estimulação contralateral. Comparou-se os resultados das orelhas direita dos dois grupos. RESULTADOS: Houve associação entre zumbido e ausência de supressão em todas as freqüências estudadas (OR>2,1). CONCLUSÕES: Houve uma correlação entre menor efetividade do trato olivococlear medial e a presença de zumbido.