33 resultados para Spectrometer


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Simple experiments are proposed for measuring molecular absorption of chromate and dichromate ions using an atomic absorption spectrometer. The experiments can help undergraduate students in instrumental analysis courses understand important aspects involving conceptual and instrumental similarities and differences between frequently used analytical techniques. Hollow cathode lamps were selected with wavelengths in the region of molecular absorption of chromate and dichromate. Calibration curves were obtained and the linear dynamic range was evaluated. Results were compared with those obtained in a molecular absorption spectrometer. The molar absorptivities obtained were also compared.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new procedure to find the limiting range of the photomultiplier linear response of a low-cost, digital oscilloscope-based time-resolved laser-induced luminescence spectrometer (TRLS), is presented. A systematic investigation on the instrument response function with different signal input terminations, and the relationship between the luminescence intensity reaching the photomultiplier and the measured decay time are described. These investigations establish that setting the maximum intensity of the luminescence signal below 0.3V guarantees, for signal input terminations equal or higher than 99.7 ohm, a linear photomultiplier response.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The identification of the chemical compounds of the essential oil was performed with a gas chromatograph coupled to a mass spectrometer. The oil was left in the presence and absence of light and submitted to different temperatures to evaluate its stability. The yields of the major compounds were evaluated every fifteen days. Citral and myrcene, the major compounds of the essential oil, were degraded over time in both the presence and absence of light, but temperature only influenced the degradation of myrcene.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A procedure for determining of the isotope ratio 235U/238U in UF6 samples was established using a quadrupole mass spectrometer with ionization by electron impact. The following items were optimized in the spectrometer: the parameters in the ion source that provided the most intense peak, with good shape, for the most abundant isotope; the resolution that reduced the non linear effects and the number of analytical cycles that reduced the uncertainty in the results. The measurement process was characterized with respect to the effects of mass discrimination, linearity and memory effect.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and sensitive on-line flow injection system for determination of zinc with FAAS has been described. The method is based on the separation and preconcentration of zinc on a microcolumn of immobilized Alizarin Red S on alumina. The adsorbed analyte is then eluted with 250 µL of nitric acid (1 mol L-1) and is transported to flame atomic absorption spectrometer for quantification. The effect of pH, sample and eluent flow rates and presence of various cations and anions on the retention of zinc was investigated. The sorption of zinc was quantitative in the pH range of 5.5-8.5. For a sample volume of 25 mL an enrichment factor of 144 and a detection limit (3S) of 0.2 µg L-1 was obtained. The precision (RSD, n=7) was 3.0% at the 20 µg L-1 level. The developed system was successfully applied to the determination of zinc in water samples, hair, urine and saliva.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gas-phase SiCl3+ ions undergo sequential solvolysis type reactions with water, methanol, ammonia, methylamine and propylene. Studies carried out in a Fourier Transform mass spectrometer reveal that these reactions are facile at 10-8 Torr and give rise to substituted chlorosilyl cations. Ab initio and DFT calculations reveal that these reactions proceed by addition of the silyl cation to the oxygen or nitrogen lone pair followed by a 1,3-H migration in the transition state. These transition states are calculated to lie below the energy of the reactants. By comparison, hydrolysis of gaseous CCl3+ is calculated to involve a substantial positive energy barrier.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present work, a simple and rapid ligand-less, in situ, surfactant-based solid phase extraction for the preconcentration of copper in water samples was developed. In this method, a cationic surfactant (n-dodecyltrimethylammonium bromide) was dissolved in an aqueous sample followed by the addition of an appropriate ion-pairing agent (ClO4-). Due to the interaction between the surfactant and ion-pairing agent, solid particles were formed and subsequently used for the adsorption of Cu(OH)2 and CuI. After centrifugation, the sediment was dissolved in 1.0 mL of 1 mol L-1 HNO3 in ethanol and aspirated directly into the flame atomic absorption spectrometer. In order to obtain the optimum conditions, several parameters affecting the performance of the LL-ISS-SPE, including the volumes of DTAB, KClO4, and KI, pH, and potentially interfering ions, were optimized. It was found that KI and phosphate buffer solution (pH = 9) could extract more than 95% of copper ions. The amount of copper ions in the water samples varied from 3.2 to 4.8 ng mL-1, with relative standard deviations of 98.5%-103%. The determination of copper in water samples was linear over a concentration range of 0.5-200.0 ng mL-1. The limit of detection (3Sb/m) was 0.1 ng mL-1 with an enrichment factor of 38.7. The accuracy of the developed method was verified by the determination of copper in two certified reference materials, producing satisfactory results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the optimization of a multiresidue chromatographic analysis for the identification and quantification of 20 pesticides in bovine milk, including three carbamates, a carbamate oxime, six organophosphates, two strobilurins, a pyrethroid, an oxazolidinedione, an aryloxyphenoxypropionate acid/ester, a neonicotinoid, a dicarboximide, and three triazoles. The influences of different chromatographic columns and gradients were evaluated. Furthermore, four different extraction methods were evaluated; each utilized both different solvents, including ethyl acetate, methanol, and acetonitrile, and different workup steps. The best results were obtained by a modified QuEChERS method that lacked a workup step, and that included freezing the sample for 2 hours at -20 ºC. The results were satisfactory, yielding coefficients of variation of less than 20%, with the exception of the 50 µg L-1 sample of famoxadone, and recoveries between 70 and 120%, with the exception of acephate and bifenthrin; however, both analytes exhibited coefficients of variation of less than 20%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ni–W–P electrodeposits were synthesized in a Hull cell in order to simulate the obtainment under industrial conditions. Complete coverage of panels was accomplished by applying total currents of 1.0 and 2.0 A. Panels obtained with a current of 1.0 A appeared brighter. The best compositional uniformities, as determined by Energy Dispersive Spectrometer (EDS) occurred in the current density ranges of 0.6 to 3.0 A dm−2 and 1.6 to 6.0 A dm−2 obtained with 1.0 and 2.0 A, respectively. However, the best morphological characteristics, as determined by Scanning Electro Microscope (SEM), were observed in those obtained with a total current of 1.0 A. Analysis of corrosion resistance by Electrochemical Impedance Spectroscopy (EIS) and Potentiodynamic Linear Polarization (PLP) in NaCl have shown significant variations in the amount of corrosion potential, polarization resistance, and even total impedance. The alloys exhibited amorphous character (XRD) and crystallized above 400 °C to Ni and Ni3P phases, and possibly Ni–W, with a subsequent increase in hardness. The results suggest that under industrial conditions, current density variations due to the large and complex geometric shapes of substrates lead to formation of distinct alloys. Furthermore, these materials are potential substitutes for chromium deposits in many applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The leaf essential oils of Eugenia lutescens Cambess andEugenia langsdorffii O. Berg, collected in the rainy (RS) and dry seasons (DS), were extracted by hydrodistillation and then characterized by a gas chromatography-flame ionization detector and a gas chromatography-mass spectrometer. The potential acaricidal activity and oviposition deterrence of these oils were evaluated against Tetranychus urticae . The oil yields were higher in the RS for E. lutescens, while those forE. langsdorffii were higher in the DS. α-Pinene and β-pinene were determined to be the major constituents of the oils fromE. lutescens, while bicyclogermacrene, spathulenol, and β-caryophyllene predominated in E. langsdorffii . Seasonal variations in the oils were primarily related to chemical diversity, and E. lutescens was more affected than was E. langsdorffii . The E. langsdorffii oil collected in the DS was most toxic to the spider mite, while the oils of E. lutescens and E. langsdorffii collected in the RS drastically reduced its egg quantities. This study successfully determined the periods of greater oil production and acaricidal activity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses a rapid and sensitive method developed to determine trace levels of mercury in natural water samples by cold vapor atomic absorption spectrometry using a preconcentration system composed by mini-column packed with 100 mg of 2-aminothiazol modified silica gel (SiAT) coupled on-line with the spectrometer's cold vapor generator system. The optimum preconcentration conditions are also described here. The preconcentrated Hg(II) ions were eluted directly from the column to the spectrometer's cold vapor generator system using 100 µL of 2 mol L-1 hydrochloric acid and the retention efficiency achieved exceeded 95%. The enrichment factors determined were 29, 38 and 46 using 3, 4 and 5 mL of preconcentrated aqueous solutions containing 400 ng L-1 of Hg. The detection limit calculated was 5 ng L-1. The preconcentration procedure was applied to determine trace level mercury in spiked river water samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this work was to evaluate the translocation of glyphosate in C. bonariensis plants resistant and susceptible to that herbicide. The 14C-glyphosate was mixed with commercial gyhphosate (800 g ha-1) and applied on the center of the adaxial face of a third node leaf, using a micro syringe, and adding 10 µL of a solution with specific activity of 1,400 Bq, 45 days after plant emergence. The concentration of the glyphosate translocated in the plant was evaluated at time intervals of 6, 12, 36 and 72 hours after being applied on the application leaf, stem, roots and leaves. Ten hours after treatment application, the distribution of the product in the application leaf, divided into base, center and apex, was also evaluated by measuring the radiation emitted by 14C-glyphosate in a liquid scintillation spectrometer. Greater glyphosate retention was observed in the resistant biotype leaf, approximately 90% of the total absorbed up to 72 hours. In the susceptible biotype, this value was close to 70% in the same period. Susceptible biotype leaves, stem and roots showed greater concentration of glyphosate, indicating greater translocation efficiency in this biotype. In the resistant biotype, the herbicide accumulated in greater quantity at the apex and center of the application leaf, while in the susceptible biotype greater accumulation was observed at the base and center leaf. Thus, it can be stated that the resistance mechanism is related to the differential translocation of this herbicide in the biotypes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ABSTRACT The objective of this study was to evaluate the availability of herbicides clomazone and tebuthiuron in the solution in different kinds of soils saturated with water or vinasse. Samples of 30 soils with different characteristics were arranged on trays to the herbicides spraying. Then they were homogenized, placed in plastic cartridges and saturated with deionized water or vinasse, and remaining at rest during 18 hours. Two extractions were made, the first one quantified the presence of the herbicides in the soil solution and in the second one the total extraction of herbicide remaining in the soil was taken to determine the recovery percentage of each herbicide tested. For quantification, a LC-MS/MS system was used, a compound of a high performance liquid chromatograph (HPLC) coupled to a triple quadruple mass spectrometer. Tebuthiuron was more available in the soil with the vinasse addition when compared to water. Vinasse applications resulted in no significant difference in availability of clomazone between treatments. Tebuthiuron showed the highest availability frequencies, and on average of all samples 32.49% were extracted from total herbicide applied, while for clomazone this value was 16.50%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect of proton pump inhibitors and Helicobacter pylori infection on the bioavailability of antibiotics is poorly understood. We determined the effects of 5-day oral administration of 60 mg lansoprazole on the bioavailability of clarithromycin in individuals with and without H. pylori infection. Thirteen H. pylori-infected and 10 non-infected healthy volunteers were enrolled in a study with an open-randomized two-period crossover design and a 21-day washout period between phases. Plasma concentrations of clarithromycin in subjects with and without lansoprazole pre-treatment were measured by liquid chromatography coupled to a tandem mass spectrometer. Clarithromycin Cmax and AUC0-10 h were significantly reduced after lansoprazole administration. In addition, lansoprazole treatment of the H. pylori-positive group resulted in a statistically significant greater reduction in Cmax (40 vs 15%) and AUC0-10 h (30 vs 10%) compared to lansoprazole-treated H. pylori-negative subjects. Thus, treatment with lansoprazole for 5 days reduced bioavailability of clarithromycin, irrespective of H. pylori status. This reduction, however, was even more pronounced in H. pylori-infected individuals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The continuous intravenous administration of isotopic bicarbonate (NaH13CO2) has been used for the determination of the retention of the 13CO2 fraction or the 13CO2 recovered in expired air. This determination is important for the calculation of substrate oxidation. The aim of the present study was to evaluate, in critically ill patients with sepsis under mechanical ventilation, the 13CO2 recovery fraction in expired air after continuous intravenous infusion of NaH13CO2 (3.8 µmol/kg diluted in 0.9% saline in ddH2O). A prospective study was conducted on 10 patients with septic shock between the second and fifth day of sepsis evolution (APACHE II, 25.9 ± 7.4). Initially, baseline CO2 was collected and indirect calorimetry was also performed. A primer of 5 mL NaH13CO2 was administered followed by continuous infusion of 5 mL/h for 6 h. Six CO2 production (VCO2) measurements (30 min each) were made with a portable metabolic cart connected to a respirator and hourly samples of expired air were obtained using a 750-mL gas collecting bag attached to the outlet of the respirator. 13CO2 enrichment in expired air was determined with a mass spectrometer. The patients presented a mean value of VCO2 of 182 ± 52 mL/min during the steady-state phase. The mean recovery fraction was 0.68 ± 0.06%, which is less than that reported in the literature (0.82 ± 0.03%). This suggests that the 13CO2 recovery fraction in septic patients following enteral feeding is incomplete, indicating retention of 13CO2 in the organism. The severity of septic shock in terms of the prognostic index APACHE II and the sepsis score was not associated with the 13CO2 recovery fraction in expired air.