19 resultados para Spectral Difference Method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract: Fifty-five bursa of Fabricius (BF) were evaluated by optical microscopy for three different avian histopathologists (H1, H3 and H4) to determine the degree of lymphoid depletion. One histologist evaluated the same slides at two different times (H1 and H2) with four-months interval between the observations. The same BFs were evaluated using the system of Digital Lymphocyte Depletion Evaluation (ADDL), being performed by three differents operators of the system, not histopathologists. The results showed was a significant difference between the histopathologists and between the scores established by the same expert (H1 and H2). However, there were not significant differences between the scores with the ADDL system, obtained using ADDL. The results make clear the fragility of the subjective lymphocyte depletion score classification by the traditional histologic method, while the ADDL system proves to be more appropriated for the assessment of the lymphoid loss in the BF.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present report describes the development of a technique for automatic wheezing recognition in digitally recorded lung sounds. This method is based on the extraction and processing of spectral information from the respiratory cycle and the use of these data for user feedback and automatic recognition. The respiratory cycle is first pre-processed, in order to normalize its spectral information, and its spectrogram is then computed. After this procedure, the spectrogram image is processed by a two-dimensional convolution filter and a half-threshold in order to increase the contrast and isolate its highest amplitude components, respectively. Thus, in order to generate more compressed data to automatic recognition, the spectral projection from the processed spectrogram is computed and stored as an array. The higher magnitude values of the array and its respective spectral values are then located and used as inputs to a multi-layer perceptron artificial neural network, which results an automatic indication about the presence of wheezes. For validation of the methodology, lung sounds recorded from three different repositories were used. The results show that the proposed technique achieves 84.82% accuracy in the detection of wheezing for an isolated respiratory cycle and 92.86% accuracy for the detection of wheezes when detection is carried out using groups of respiratory cycles obtained from the same person. Also, the system presents the original recorded sound and the post-processed spectrogram image for the user to draw his own conclusions from the data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Heart rate variability (HRV) provides important information about cardiac autonomic modulation. Since it is a noninvasive and inexpensive method, HRV has been used to evaluate several parameters of cardiovascular health. However, the internal reproducibility of this method has been challenged in some studies. Our aim was to determine the intra-individual reproducibility of HRV parameters in short-term recordings obtained in supine and orthostatic positions. Electrocardiographic (ECG) recordings were obtained from 30 healthy subjects (20-49 years, 14 men) using a digital apparatus (sampling ratio = 250 Hz). ECG was recorded for 10 min in the supine position and for 10 min in the orthostatic position. The procedure was repeated 2-3 h later. Time and frequency domain analyses were performed. Frequency domain included low (LF, 0.04-0.15 Hz) and high frequency (HF, 0.15-0.4 Hz) bands. Power spectral analysis was performed by the autoregressive method and model order was set at 16. Intra-subject agreement was assessed by linear regression analysis, test of difference in variances and limits of agreement. Most HRV measures (pNN50, RMSSD, LF, HF, and LF/HF ratio) were reproducible independent of body position. Better correlation indexes (r > 0.6) were obtained in the orthostatic position. Bland-Altman plots revealed that most values were inside the agreement limits, indicating concordance between measures. Only SDNN and NNv in the supine position were not reproducible. Our results showed reproducibility of HRV parameters when recorded in the same individual with a short time between two exams. The increased sympathetic activity occurring in the orthostatic position probably facilitates reproducibility of the HRV indexes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

New microbiological methods have been developed and commercialized, but their performance must be guaranteed. The aim of the present study was to evaluate the PetrifilmTM and TEMPO® systems compared to the conventional method for counting microorganisms in pasteurized milk. A total of 141 samples of pasteurized milk were analyzed by counting mesophilic aerobic, Coliforms at 35 ºC, Coliforms at 45 ºC, and Escherichia coli microorganisms. High correlation was found between the methods for counting Coliforms at 35 ºC, but low correlation was found for counting mesophilic aerobic, Coliforms at 45 ºC, and Escherichia coli. No significant statistical difference was found among the three methods for counting Coliforms at 35 ºC; however, the mean counts of mesophilic aerobic, Coliforms at 45 ºC, and Escherichia coli showed significant statistical difference. PetrifilmTM and TEMPO® systems had satisfactory results for Coliforms at 35 ºC in pasteurized milk but low performance for mesophilic aerobic, Coliforms at 45 ºC and Escherichia coli.