246 resultados para Rapid test


Relevância:

60.00% 60.00%

Publicador:

Resumo:

We used a colorimetric reverse dot blot hybridization (CRDH) assay to detect the presence of mutations in a specific region of the rpoB gene, associated with rifampin (RIF) resistance, in a panel of 156 DNAs extracted from 103 RIF-sensitive and 53 RIF-resistant cultures of Mycobacterium tuberculosis. When compared with the antimicrobial susceptibility test (AST), the sensitivity and specificity of the CRDH were 92.3% and 98.1%, respectively. When compared with sequencing, the sensitivity and specificity of the CRDH were 90.6% and 100%, respectively. To evaluate the performance of the assay directly in clinical specimens, 30 samples from tuberculosis patients were used. For these samples, the results of the CRDH were 100% consistent with the results of the AST and sequencing. These results indicate that the rate of concordance of the CRDH is high when compared to conventional methods and sequencing data. The CRDH can be successfully applied when a rapid test is required for the identification of RIF resistance in M. tuberculosis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Human herpesvirus 6 (HHV-6) may cause severe complications after haematopoietic stem cell transplantation (HSCT). Monitoring this virus and providing precise, rapid and early diagnosis of related clinical diseases, constitute essential measures to improve outcomes. A prospective survey on the incidence and clinical features of HHV-6 infections after HSCT has not yet been conducted in Brazilian patients and the impact of this infection on HSCT outcome remains unclear. A rapid test based on real-time quantitative polymerase chain reaction (qPCR) has been optimised to screen and quantify clinical samples for HHV-6. The detection step was based on reaction with TaqMan® hydrolysis probes. A set of previously described primers and probes have been tested to evaluate efficiency, sensitivity and reproducibility. The target efficiency range was 91.4% with linearity ranging from 10-106 copies/reaction and a limit of detection of five copies/reaction or 250 copies/mL of plasma. The qPCR assay developed in the present study was simple, rapid and sensitive, allowing the detection of a wide range of HHV-6 loads. In conclusion, this test may be useful as a practical tool to help elucidate the clinical relevance of HHV-6 infection and reactivation in different scenarios and to determine the need for surveillance.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Simple and rapid latex-based diagnostic tests have been used for detecting specific antigens or antibodies in several diseases. In this article, we present the preliminary results obtained with a latex agglutination test (LAT) for diagnosing neurocysticercosis by detection of antibodies in CSF. A total of 43 CSF samples were assayed by the LAT: 19 CSF samples from patients with neurocysticercosis and 24 CSF samples from patients with other neurologic disorders (neurosyphilis, n = 8; neurotoxoplasmosis, n = 3; viral meningitis, n = 4, chronic headache, n = 9). The LAT exhibited 89.5% sensitivity and 75% specificity. The use of LAT seems to be an additional approach for the screening of neurocysticercosis with advantage of simplicity and rapidity. Further studies could be performed using purified antigens and serum samples.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The present study was carried out to evaluate the Malar-CheckTM Pf test, an immunochromatographic assay that detects Plasmodium falciparum Histidine Rich Protein II, does not require equipment, and is easy and rapid to perform. In dilution assays performed to test sensitivity against known parasite density, Malar-CheckTMwere compared with thick blood smear (TBS), the gold standard for diagnosis. Palo Alto isolate or P. falciparum blood from patients with different parasitemias was used. The average cut-off points for each technique in three independent experiments were 12 and 71 parasites/mm³ (TBS and Malar-CheckTM, respectively). In the field assays, samples were collected from patients with fever who visited endemic regions. Compared to TBS, Malar-CheckTMyielded true-positive results in 38 patients, false-positive results in 3, true-negative results in 23, and false-negative result in 1. Malar-CheckTMperformed with samples from falciparum-infected patients after treatment showed persistence of antigen up to 30 days. Malar-CheckTM should aid the diagnosis of P. falciparum in remote areas and improve routine diagnosis even when microscopy is available. Previous P. falciparum infection, which can determine a false-positive test in cured individuals, should be considered. The prompt results obtained with the Malar-CheckTM for early diagnosis could avoid disease evolution to severe cases.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study evaluated the whole blood immunochromatographic card test (ICT card test) in a survey performed in Northeastern Brazil. 625 people were examined by the thick blood film (TBF) and ICT card test. Residents of a non-endemic area were also tested by the whole blood card test and Og4C3. The sensitivity of the ICT card test was 94.7% overall, but lower in females than males, based on the reasonable assumption that TBF is 100% specific. However, since TBF and other methods have unknown sensitivity, the true specificity of the card test is unknown. Nevertheless, it is possible to estimate upper and lower limits for the specificity, and relate it to the prevalence of the disease. In the endemic area, the possible range of the specificity was from 72.4% to 100%. 29.6% of the card tests performed in the non-endemic area exhibited faint lines that were interpreted as positives. Characteristics of the method including high sensitivity, promptness and simplicity justify its use for screening of filariasis. However, detailed information about the correct interpretation in case of extremely faint lines is essential. Further studies designed to consider problems arising from imperfect standards are necessary, as is a sounder diagnostic definition for the card test.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to validate the rapid lateral flow Helicobacter pylori stool antigen test (One step H. pylori antigen test, ACON laboratories, San Diego, USA; Prime diagnostics, São Paulo), using 13C-Urea Breath Test as the gold standard for H. pylori infection diagnosis. A total of 98 consecutive patients, asymptomatic or dyspeptic, entered the study. Sixty-nine were women, with a mean age of 45.76 ± 14.59 years (14 to 79 years). In the H. pylori-positive group, the rapid stool antigen test detected H. pylori antigen in 44 of the 50 positive patients (sensitivity 88%; 95% CI: 75.7-95.5%), and six false-negative; and in the H. pylori-negative group 42 presented negative results (specificity 87.5%; 95% CI: 74.7-95.3%), and six false-positive, showing a substantial agreement (Kappa Index = 0.75; p < 0.0001; 95% CI: 0.6-0.9). Forty four of fifty patients that had positive stool antigen were H. pylori-positive, the PPV of the stool antigen test was 88% (95% CI: 75.7-95.5%), and 42 patients with negative stool antigen test were H. pylori-negative, the NPV of the stool antigen test was 87.5% (95% CI: 74.7-95.3%). We conclude that the lateral flow stool antigen test can be used as an alternative to breath test for H. pylori infection diagnosis especially in developing countries.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mycobaterium leprae infection was investigated in armadillos from the State of Espírito Santo, Brazil. The ML Flow test was performed on 37 nine-banded armadillos and positive results were found in 11 (29.7%). The ML Flow test may be used to identify possible sources of Mycobaterium leprae among wild armadillos.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction Rapid diagnostic tests (RDTs) may improve the early detection of visceral leishmaniasis (VL), but their real-world performance requires additional study. Therefore, we evaluated the performance of an rK39-based RDT (Kalazar Detect™) for the detection of VL in an endemic, large urban area. Methods Data were collected from a registry of rK39 RDT performed at 11 emergency care units in Belo Horizonte, Brazil, and from a national database of reportable communicable diseases of the Sistema de Informação de Agravos de Notificação (SINAN). Results The rapid rK39 test was performed in 476 patients, with 114 (23.9%) positive results. The analysis of rK39 RDT performance was based on 381 (80%) cases reported to the SINAN database, of which 145 (38.1%) were confirmed cases. Estimates for sensitivity and specificity were 72.4% (95% CI: 64.6-79%) and 99.6% (95%CI: 97.6-99.9%), respectively. Positive and negative predictive values were estimated at 99.1% (95%CI: 94.9-99.8%) and 85.5% (95%CI: 80.8-89.1%), respectively. In addition, close agreement between the rK39 RDT and indirect immunofluorescence was observed. Conclusions In summary, the rK39 RDT showed a high specificity but only moderate sensitivity. In endemic areas for VL, treatment may be considered in cases with clinical manifestations and a positive rK39 RDT, but those with a negative test should be subjected to further investigation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This article presents an improvement to the Kato-Katz (KK) method, making it faster and more efficient for the visualisation of fertile eggs in stool samples. This modified KK method uses sodium acetate formalin as a fixative and reveals the intensity of infection in less than 1 h, reducing the diagnostic time without increasing the cost. This modified method may contribute to future epidemiological studies in both hospitals and the field due to its rapid and precise diagnostic, which allow for immediate treatment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A qualitative spot-test and tandem quantitative analysis of dipyrone in the bulk drug and in pharmaceutical preparations is proposed. The formation of a reddish-violet color indicates a positive result. In sequence a quantitative procedure can be performed in the same flask. The quantitative results obtained were statistically compared with those obtained with the method indicated by the Brazilian Pharmacopoeia, using the Student's t and the F tests. Considering the concentration in a 100 µL aliquot, the qualitative visual limit of detection is about 5×10-6 g; instrumental LOD ≅ 1.4×10-4 mol L-1 ; LOQ ≅ 4.5×10-4 mol L-1.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A rapid conglutination test (RCT) with performance comparable to the indirect fluorescent antibody technique (IFAT) was developed to detect antibodies against Babesia bigemina (B. bigemina-RCT). The B. bigemina-RCT is a sensitive, specific, economical, and rapidly performed serological test suitable for field application or minimally equipped laboratories. This test had a sensitivity of 90.9%, and specificity of 97.6%, compared to IFAT, which showed for the same parameters respectively, 98.3% and 99.7%. The early detection of anti- B. bigemina immunoglobulins by RCT in experimental infections was nearly parallel to that of IFAT. Cross reactions were observed with sera from calves experimentally infected with Babesia bovis (1.8%) and with Anaplasma marginale (1.2%). RCT antigen prepared with non parasitized erythrocytes (negative antigen) showed 1.5%, 3.5% and 2.2% of positive reactions with sera from animals experimentally infected with B. bigemina, B. bovis and A. marginale. However, none of the sera from animals of endemic areas for babesia infection resulted in positive reactions with the negative antigen. Considering these results and shelf life over six months, the B. bigemina-RCT could be used for epidemiological surveys and evaluation of control measures against this species of Babesia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A passive haemagglutination test (PHA) for human neurocysticercosis was standardized and evaluated for the detection of specific antibodies to Cysticercus cellulosae in cerebrospinal fluid (CSF). For the assay, formaldehyde-treated group O Rh-human red cells coated with the cysticerci crude total saline extract (TS) antigen were employed. A total of 115 CSF samples from patients with neurocysticercosis was analysed, of these 94 presented reactivity, corresponding to 81.7% sensitivity, in which confidence limit of 95% probability (CL95%) ranged from 74.5% to 88.9%. Eighty-nine CSF samples derived from individuals of control group presented as nonreactive in 94.4% (CL95% from 89.6% to 99.2%). The positive and negative predictive values were 1.4% and 99.9%, respectively, considering the mean rate of that this assay provide a rapid, highly reproducible, and moderately sensitive mean of detecting specific antibodies in CSF samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the objective of standardizing a Dot Enzyme-Linked Immunosorbent Assay (Dot-ELISA) to detect antigens of fecal bacterial enteropathogens, 250 children, aged under 36 months and of both sexes, were studied; of which 162 had acute gastroenteritis. The efficacy of a rapid screening assay for bacterial enteropathogens (enteropathogenic Escherichia coli "EPEC", enteroinvasive Escherichia coli "EIEC", Salmonella spp. and Shigella spp.) was evaluated. The fecal samples were also submitted to a traditional method of stool culture for comparison. The concordance index between the two techniques, calculated using the Kappa (k) index for the above mentioned bacterial strains was 0.8859, 0.9055, 0.7932 and 0.7829 respectively. These values express an almost perfect degree of concordance for the first two and substantial concordance for the latter two, thus enabling this technique to be applied in the early diagnosis of diarrhea in infants. With a view to increasing the sensitivity and specificity of this immunological test, a study was made of the antigenic preparations obtained from two types of treatment: 1) deproteinization by heating; 2) precipitation and concentration of the lipopolysaccharide antigen (LPS) using an ethanol-acetone solution, which was then heated in the presence of sodium EDTA

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Candida albicans is often isolated from clinical samples, thus its presumptive differentiation from other species of the same genus can be based on its ability to form the germ tube in human serum. Nevertheless, there are two other species that share this characteristic: C. dubliniensis and C. africana. The aim of this study was to compare four different substrates to perform the germ tube (GT) test. The Candida spp. isolates were identified using a manual system (135 C. albicans, 24 C. tropicalis and one C. dubliniensis). The germ tube test was performed with fresh, previously frozen serum and Mueller-Hinton (MH) broth and agar. GT was observed in 96% (130/136) of the isolates through the fresh serum technique, 94% (128/136) through previously frozen serum, 92% (125/136) in MH agar, and 90% (122/136) in MH broth. The sensitivity of each test was higher than 90%, with 100% specificity. Both the MH agar and broth were able to identify the true positives, and false positives were not found. However, some C. albicans isolates were not identified. MH agar and broth may be used in laboratory for the rapid presumptive identification of C. albicans, as an alternative method for germ tube test.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A direct immunofluorescent antibody (DIFMA) test using a Leishmania genus- specific monoclonal antibody was evaluated in the routine diagnosis of cutaneous leishmaniasis (CL) in Ecuador. This test was compared with the standard diagnostic techniques of scrapings, culture and histology. Diagnostic samples were taken from a total of 90 active dermal ulcers from patients from areas of Ecuador known to be endemic for cutaneous leishmaniasis. DIFMA was positive in all lesions. It was shown to be significantly superior to standard diagnostic methods either alone or in combination. The sensitivity of DIFMA did not diminish with chronicity of lesions. This test proved to be extremely useful in the routine diagnosis of CL because it is highly sensitive, is easy to use and produces rapid results.