23 resultados para Order tracking


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The bioassay, first order derivative UV spectrophotometry and chromatographic methods for assaying fluconazole capsules were compared. They have shown great advantages over the earlier published methods. Using the first order derivative, the UV spectrophotometry method does not suffer interference of excipients. Validation parameters such as linearity, precision, accuracy, limit of detection and limit of quantitation were determined. All methods were linear and reliable within acceptable limits for antibiotic pharmaceutical preparations being accurate, precise and reproducible. The application of each method as a routine analysis should be investigated considering cost, simplicity, equipment, solvents, speed, and application to large or small workloads.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO A tomada de decisão é uma das dimensões essenciais da formação do profissional da saúde, como mencionado nas atuais Diretrizes Curriculares Nacionais do Curso de Graduação em Medicina. O processo decisório, no âmbito da saúde, envolve diferentes aspectos, incluindo os elementos (bio)éticos. Nesse sentido, pesquisas que investiguem a tomada de decisão em (bio)ética poderão elucidar passos ainda não completamente esclarecidos, permitindo uma construção mais efetiva das competências em (bio)ética, na graduação e na pós-graduação. Diante desta perspectiva, o objetivo deste estudo é explorar possibilidades de uso do Mobile Eye Tracking para o estudo do papel da atenção visual – durante a exibição de filmes de cinema – no processo decisório em (bio)ética.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement of cardiovascular features of wild animals is important, as is the measurement in pets, for the assessment of myocardial function and the early detection of cardiac abnormalities, which could progress to heart failure. Speckle tracking echocardiography (2D STE) is a new tool that has been used in veterinary medicine, which demonstrates several advantages, such as angle independence and the possibility to provide the early diagnosis of myocardial alterations. The aim of this study was to evaluate the left myocardial function in a maned wolf by 2D STE. Thus, the longitudinal, circumferential and radial strain and strain rate were obtained, as well as, the radial and longitudinal velocity and displacement values, from the right parasternal long axis four-chamber view, the left parasternal apical four chamber view and the parasternal short axis at the level of the papillary muscles. The results of the longitudinal variables were -13.52±7.88, -1.60±1.05, 4.34±2.52 and 3.86±3.04 for strain (%), strain rate (1/s), displacement (mm) and velocity (cm/s), respectively. In addition, the radial and circumferential Strain and Strain rate were 24.39±14.23, 1.86±0.95 and -13.69±6.53, -1.01±0.48, respectively. Thus, the present study provides the first data regarding the use of this tool in maned wolves, allowing a more complete quantification of myocardial function in this species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article deals with a contour error controller (CEC) applied in a high speed biaxial table. It works simultaneously with the table axes controllers, helping them. In the early stages of the investigation, it was observed that its main problem is imprecision when tracking non-linear contours at high speeds. The objectives of this work are to show that this problem is caused by the lack of exactness of the contour error mathematical model and to propose modifications in it. An additional term is included, resulting in a more accurate value of the contour error, enabling the use of this type of motion controller at higher feedrate. The response results from simulated and experimental tests are compared with those of common PID and non-corrected CEC in order to analyse the effectiveness of this controller over the system. The main conclusions are that the proposed contour error mathematical model is simple, accurate, almost insensible to the feedrate and that a 20:1 reduction of the integral absolute contour error is possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When two stimuli are presented simultaneously to an observer, the perceived temporal order does not always correspond to the actual one. In three experiments we examined how the location and spatial predictability of visual stimuli modulate the perception of temporal order. Thirty-two participants had to report the temporal order of appearance of two visual stimuli. In Experiment 1, both stimuli were presented at the same eccentricity and no perceptual asynchrony between them was found. In Experiment 2, one stimulus was presented close to the fixation point and the other, peripheral, stimulus was presented in separate blocks in two eccentricities (4.8º and 9.6º). We found that the peripheral stimulus was perceived to be delayed in relation to the central one, with no significant difference between the delays obtained in the two eccentricities. In Experiment 3, using three eccentricities (2.5º, 7.3º and 12.1º) for the presentation of the peripheral stimulus, we compared a condition in which its location was highly predictable with two other conditions in which its location was progressively less predictable. Here, the perception of the peripheral stimulus was also delayed in relation to the central one, with this delay depending on both the eccentricity and predictability of the stimulus. We argue that attentional deployment, manipulated by the spatial predictability of the stimulus, seems to play an important role in the temporal order perception of visual stimuli. Yet, under whichever condition of spatial predictability, basic sensory and attentional processes are unavoidably entangled and both factors must concur to the perception of temporal order.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present paper we discuss the development of "wave-front", an instrument for determining the lower and higher optical aberrations of the human eye. We also discuss the advantages that such instrumentation and techniques might bring to the ophthalmology professional of the 21st century. By shining a small light spot on the retina of subjects and observing the light that is reflected back from within the eye, we are able to quantitatively determine the amount of lower order aberrations (astigmatism, myopia, hyperopia) and higher order aberrations (coma, spherical aberration, etc.). We have measured artificial eyes with calibrated ametropia ranging from +5 to -5 D, with and without 2 D astigmatism with axis at 45º and 90º. We used a device known as the Hartmann-Shack (HS) sensor, originally developed for measuring the optical aberrations of optical instruments and general refracting surfaces in astronomical telescopes. The HS sensor sends information to a computer software for decomposition of wave-front aberrations into a set of Zernike polynomials. These polynomials have special mathematical properties and are more suitable in this case than the traditional Seidel polynomials. We have demonstrated that this technique is more precise than conventional autorefraction, with a root mean square error (RMSE) of less than 0.1 µm for a 4-mm diameter pupil. In terms of dioptric power this represents an RMSE error of less than 0.04 D and 5º for the axis. This precision is sufficient for customized corneal ablations, among other applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of aging on memory has been extensively studied, but the importance of short-term memory and recall sequence has not. The objective of the current study was to examine the recall order of words presented on lists and to determine if age affects recall sequence. Physically and psychologically healthy male subjects were divided into two groups according to age, i.e., 23 young subjects (20 to 30 years) and 50 elderly subjects (60 to 70 years) submitted to the Wechsler Adult Intelligence Scale-Revised and the free word recall test. The order of word presentation significantly affected the 3rd and 4th words recalled (P < 0.01; F = 14.6). In addition, there was interaction between the presentation order and the type of list presented (P < 0.05; F = 9.7). Also, both groups recalled the last words presented from each list (words 13-15) significantly more times 3rd and 4th than words presented in all remaining positions (P < 0.01). The order of word presentation also significantly affected the 5th and 6th words recalled (P = 0.05; F = 7.5) and there was a significant interaction between the order of presentation and the type of list presented (P < 0.01; F = 20.8). The more developed the cognitive functions, resulting mainly from formal education, the greater the cognitive reserve, helping to minimize the effects of aging on the long-term memory (episodic declarative).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to investigate the phenomenon of learning generalization of a specific skill of auditory temporal processing (temporal order detection) in children with dyslexia. The frequency order discrimination task was applied to children with dyslexia and its effect after training was analyzed in the same trained task and in a different task (duration order discrimination) involving the temporal order discrimination too. During study 1, one group of subjects with dyslexia (N = 12; mean age = 10.9 ± 1.4 years) was trained and compared to a group of untrained dyslexic children (N = 28; mean age = 10.4 ± 2.1 years). In study 2, the performance of a trained dyslexic group (N = 18; mean age = 10.1 ± 2.1 years) was compared at three different times: 2 months before training, at the beginning of training, and at the end of training. Training was carried out for 2 months using a computer program responsible for training frequency ordering skill. In study 1, the trained group showed significant improvement after training only for frequency ordering task compared to the untrained group (P < 0.001). In study 2, the children showed improvement in the last interval in both frequency ordering (P < 0.001) and duration ordering (P = 0.01) tasks. These results showed differences regarding the presence of learning generalization of temporal order detection, since there was generalization of learning in only one of the studies. The presence of methodological differences between the studies, as well as the relationship between trained task and evaluated tasks, are discussed.