23 resultados para On-line mathematics learning
Resumo:
A flow system coupled to a tungsten coil atomizer in an atomic absorption spectrometer (TCA-AAS) was developed for As(III) determination in waters, by extraction with sodium diethyldithiocarbamate (NaDDTC) as complexing agent, and by sorption of the As(III)-DDTC complex in a micro-column filled with 5 mg C18 reversed phase (10 µL dry sorbent), followed by elution with ethanol. A complete pre-concentration/elution cycle took 208 s, with 30 s sample load time (1.7 mL) and 4 s elution time (71 µL). The interface and software for the synchronous control of two peristaltic pumps (RUN/ STOP), an autosampler arm, seven solenoid valves, one injection valve, the electrothermal atomizer and the spectrometer Read function were constructed. The system was characterized and validated by analytical recovery studies performed both in synthetic solutions and in natural waters. Using a 30 s pre-concentration period, the working curve was linear between 0.25 and 6.0 µg L-1 (r = 0.9976), the retention efficiency was 94±1% (6.0 µg L-1), and the pre-concentration coefficient was 28.9. The characteristic mass was 58 pg, the mean repeatability (expressed as the variation coefficient) was 3.4% (n=5), the detection limit was 0.058 µg L-1 (4.1 pg in 71 µL of eluate injected into the coil), and the mean analytical recovery in natural waters was 92.6 ± 9.5 % (n=15). The procedure is simple, economic, less prone to sample loss and contamination and the useful lifetime of the micro-column was between 200-300 pre-concentration cycles.
Resumo:
A liquid chromatography-tandem mass spectrometry method with atmospheric pressure chemical ionization (LC-APCI/MS/MS) was validated for the determination of etoricoxib in human plasma using antipyrin as internal standard, followed by on-line solid-phase extraction. The method was performed on a Luna C18 column and the mobile phase consisted of acetonitrile:water (95:5, v/v)/ammonium acetate (pH 4.0; 10 mM), run at a flow rate of 0.6 mL/min. The method was linear in the range of 1-5000 ng/mL (r²>0.99). The lower limit of quantitation was 1 ng/mL. The recoveries were within 93.72-96.18%. Moreover, method validation demonstrated acceptable results for the precision, accuracy and stability studies.
Resumo:
A simple and sensitive on-line flow injection system for determination of zinc with FAAS has been described. The method is based on the separation and preconcentration of zinc on a microcolumn of immobilized Alizarin Red S on alumina. The adsorbed analyte is then eluted with 250 µL of nitric acid (1 mol L-1) and is transported to flame atomic absorption spectrometer for quantification. The effect of pH, sample and eluent flow rates and presence of various cations and anions on the retention of zinc was investigated. The sorption of zinc was quantitative in the pH range of 5.5-8.5. For a sample volume of 25 mL an enrichment factor of 144 and a detection limit (3S) of 0.2 µg L-1 was obtained. The precision (RSD, n=7) was 3.0% at the 20 µg L-1 level. The developed system was successfully applied to the determination of zinc in water samples, hair, urine and saliva.
Resumo:
The present work purposes the preparation of a silica gel sorbent organically modified with 2-aminoethyl-3-aminobutylmethyldimethoxysilane (AAMDMS) and imprinted with Cu2+ ions by means surface imprinting technique and its use for selective on-line sorbent preconcentration of Cu2+ ions with further UV-VIS spectrophotometric determination by flow injection analysis. The Cu2+-imprinted silica gel, when compared with non imprinted silica gel and silica gel, showed from the binary mixture of Cu2+/Ni2+ relative selectivity coefficient (k') of 6.84 and 5.43 and 6.64 and 19.83 for the mixture Cu2+/Pb2+, thus demonstrating higher selectivity of Cu2+-imprinted silica gel towards Cu2+ ions. Under optimized condition, the on-line preconcentration method provided detection limit of 3.4 μg L-1 and linear range ranging from 30.0 up to 300.0 μg L-1 (r = 0.995). The accuracy of method was successfully assessed by analyzing different kind of spiked water samples with recovery values ranging from 92.2 up to 103.0%.
Resumo:
A portable microcontrolled system is proposed to monitor conductivity, temperature and pH in on-line, in situ and remote way from a water reservoir faraway 200 m. The system comprises two modules: one for data reception (located in laboratory) and another for data acquisition/transmission (located near water reservoir). It uses a microcontroller and a transceiver to remote data transmission/reception by radio frequency. Variations of water parameters were simultaneously monitored without interruption during a period of ten hours with a relative error about 4.0 %. The developed system showed simple, stable, accurate, robust and low-cost to determine parameters of water in field.
Resumo:
OBJETIVO: Foi testar a validade e a confiabilidade de uma versão on-line do Female Sexual Function Index (FSFI). MÉTODOS: Uma versão on-line do FSFI foi comparada à versão tradicional, em papel. Para tanto, estudantes de Fisioterapia de três cidades foram alocadas randomicamente em dois grupos - G-pp/ol (n=126) e G-ol/pp (n=147). As mulheres do G-pp/ol responderam ao FSFI do modo tradicional, em papel e caneta, enquanto o G-ol/pp respondeu a uma versão on-line do mesmo questionário. Após 15 dias de intervalo, houve nova coleta, quando o G-pp/ol respondeu a versão on-line enquanto o G-ol/pp respondeu no papel. Todos os dados foram transportados para o software estatístico SPSS. Diferenças demográficas entre os dois grupos foram reveladas pelo teste t de Student ou pelo teste exato de Fischer (IC95%; p>0,05). A associação e a correlação entre as respostas entre G-pp/ol e G-ol/pp durante cada coleta foram acessadas pelo teste t e o coeficiente de Pearson. Estratégia idêntica foi utilizada para as comparações intragrupo. RESULTADOS: Um total de 273 mulheres participou do estudo e 28 (10,2%) desistiram da segunda coleta. Não houve diferenças demográficas entre os grupos. Houve associação entre 15 das 19 questões do FSFI entre os dois grupos, tanto no teste quanto no reteste. A análise intragrupo revelou que todas as questões e os escores do FSFI estiveram associados, mas fracamente correlacionados para um mesmo grupo durante as duas coletas. CONCLUSÃO: A versão on-line do FSFI apresentou validade e confiabilidade aceitáveis quando comparada à versão em papel, o que pode justificar a opção por essa modalidade, especialmente em estudos envolvendo sexualidade.
Resumo:
We studied the effects of chronic intoxication with the heavy metals lead (Pb2+) and zinc (Zn2+) on memory formation in mice. Animals were intoxicated through drinking water during the pre- and postnatal periods and then tested in the step-through inhibitory avoidance memory task. Chronic postnatal intoxication with Pb2+ did not change the step-through latency values recorded during the 4 weeks of the test (ANOVA, P>0.05). In contrast, mice intoxicated during the prenatal period showed significantly reduced latency values when compared to the control group (day 1: q = 4.62, P<0.05; day 7: q = 4.42, P<0.05; day 14: q = 5.65, P<0.05; day 21: q = 3.96, P<0.05, and day 28: q = 6.09, P<0.05). Although chronic postnatal intoxication with Zn2+ did not alter a memory retention test performed 24 h after training, we noticed a gradual decrease in latency at subsequent 4-week intervals (F = 3.07, P<0.05), an effect that was not observed in the control or in the Pb2+-treated groups. These results suggest an impairment of memory formation by Pb2+ when the animals are exposed during the critical period of neurogenesis, while Zn2+ appears to facilitate learning extinction.
Resumo:
INTRODUCTION: Neuroimaging studies suggest that obese people might show hyperactivity of brain areas regarding reward processing, and hypoactivity of brain areas concerning cognitive control, when exposed to food cues. Although the effects of bariatric surgery on the central nervous system and eating behavior are well known, few studies have used neuroimage techniques with the aim of investigating the central effects of bariatric surgery in humans. OBJECTIVES: This paper systematically and critically reviews studies using functional neuroimaging to investigate changes on the patterns of activation of central areas related to the regulation of eating behavior after bariatric surgery. METHOD: A search on the databases Medline, Web of Science, Lilacs and Science Direct on Line, was conducted in February 2013, using the keywords "Neuroimaging", "Positron-Emission Tomography", "Magnetic Resonance Imaging", "Gastric Bypass", "Gastroplasty", "Jejunoileal Bypass", "Bariatric Surgery". RESULTS: Seven manuscripts were included; the great majority studied the central effects of Roux en Y gastric bypass, using positron emission tomography or functional magnetic resonance. CONCLUSIONS: Bariatric surgery might normalize the activity of central areas concerned with reward and incentive salience processing, as the nucleus accumbens and mesencephalic tegmental ventral area, as well as circuitries processing behavioral inhibition, as the dorsolateral prefrontal cortex.