362 resultados para Orlando Costas


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents an overview of the development of analytical chemistry in Brazil in the last 25 years under the influence of Brazilian Chemical Society (SBQ). It is shown that the common sense that analytical chemistry is still an under-developed area is not true. Data from specialized literature show a significant contribution of Brazilian analytical chemists in high impact periodicals and for several areas there is a good adherence among works carried out in Brazil and abroad according to a comparison of studies presented in the 11th Brazilian Meeting on Analytical Chemistry (Campinas, September, 2001) and the XI European Conference on Analytical Chemistry (Lisboa, September, 2000). According to the opinion of investigators in this area, there are some topics that require a focused attention for proper evolution. However, there is an absolute consensus about the evolution of graduate programs and the need to improve and extend strategies to absorb newcomers in the area. Some suggestions are presented considering possible pathways of analytical chemistry in Brazil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Crude extracts of several vegetables such as peach (Prunus persica), yam (Alocasia macrorhiza), manioc (Manihot utilissima), artichoke (Cynara scolymus L), sweet potato (Ipomoea batatas (L.) Lam.), turnip (Brassica campestre ssp. rapifera), horseradish (Armoracia rusticana) and zucchini (Cucurbita pepo) were investigated as the source of peroxidase (POD: EC 1.11.1.7). Among those, zucchini (Cucurbita pepo) crude extract was found to be the best one. This enzyme in the presence of hydrogen peroxide catalyses the oxidation of paracetamol to N-acetyl-p-benzoquinoneimine which the electrochemical reduction back to paracetamol was obtained at a peak potential of ¾0.10V. A cyclic voltammetric study was performed by scanning the potential from + 0.5 to ¾ 0.5 V. The recovery of paracetamol from two samples ranged from 97.3 to 106% and a rectilinear calibration curve for paracetamol concentration from 1.2x10-4 to 2.5x10-3 mol L-1 (r=0.9965) were obtained. The detection limit was 6.9x10-5 mol L-1 and the relative standard deviation was less than 1.1% for a solution containing 2.5x10-3 mol L-1 paracetamol and 2.0x10-3 mol L-1 hydrogen peroxide (n=12). The results obtained for paracetamol in pharmaceutical products using the proposed biosensor and Pharmacopoeial procedures are in agreement at the 95% confidence level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, a spectrophotometric flow injection analysis system using a crude extract of avocado (Persea americana) as a source of polyphenol oxidase to dopamine determination was developed. The substrates and enzyme concentrations from 2.4x10-7 to 5.3x10-4 mol L-1 and 28 to 332 units mL-1 were evaluated, respectively. In addition, the FIA parameters such as sample loop (50 to 500 µL), flow rate (1.4 to 4.3 mL min-1) and reactor length (100 to 500 cm) were also evaluated in a 0.1 mol L-1 phosphate buffer solution (pH 7.0). Dopamine solution concentrations were determined using 277 units mL-1 enzyme solution, 400 mL enzyme loop, 375 µL sample loop, 2.2 mL min-1 flow rate and a reactor of 350 cm. The analytical curve showed a linearity from 5.3x10-5 to 5.3x10-4 mol L-1 dopamine with a detection limit of 1.3x10-5 mol L-1. The analytical frequency was 46 h-1 and the RSD lower than 0.5% for 5.3x10-4 mol L-1 dopamine solution (n=10). A paired t-test showed that all results obtained for dopamine in commercial formulations using the proposed flow injection procedure and a spectrophotometric procedure agree at the 95% confidence level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to analyse the content and the composition of the essential oil of five accesses of mentrasto (Ageratum conyzoides). Five accesses of mentrasto with three repetitions were used. The accesses were obtained in Mariana-MG (AMA), Piranga-MG (API), Visconde do Rio Branco (ARB) and Viçosa-MG (AVB and AVP). The essential oil was obtained by hydrodistillation and the identification of the oil components by CG and GC/MS. The ARB access presented the higher essential oil content, that is 0.70% (P < 0.05). Eleven chemical compounds were identified. The precocene I was the main constituent in the access API, and the precocene II was the main constituent in the accesses AMA, ARB, AVB and AVP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An experiment is proposed to introduce some fundamentals of flow analysis, chemiluminescence and kinetic monitoring of enzymatic reactions in undergraduate courses. Chemiluminescence detection is performed with a simple spectrophotometer equipped with a lab-made spiral flow cell constructed from a polyethylene tube. The hydrogen peroxide produced by the glucose oxidation in the presence of glucose oxidase is continuously monitored by the reaction with luminol in alkaline media in a flow injection system. The exercise allows also the discussion of important analytical features and the comparison with different optical methods of analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The construction and analytical evaluation of a coated graphite Al(III) ion-selective electrode, based on the ionic pair formed between the Al(F)n3-n anion and tricaprylylmethylammonium cation (Aliquat 336S) incorporated on a poly(vinylchloride) (PVC) matrix membrane are described. A thin membrane film of this ionic pair and dibutylphthalate (DBPh) in PVC was deposited directly on a cylindric graphite rod (2 cm length x 0.5 cm diameter) attached to the end of a glass tube using epoxy resin. The membrane solution was prepared by dissolving 40% (m/m) of PVC in 10 mL of tetrahydrofuran following addition of 45% (m/m) of DBPh and 15% (m/m) of the ionic pair. The effect of membrane composition, fluoride concentration, and several concomitants as potential interferences on the electrode response were investigated. The aluminium(III) ion-selective electrode showed a linear response ranging from 1.4 x 10-4 to 1.0 x 10-2 mol L-1, a detection limit of 4.0 x 10-5 mol L-1, aslope of -54.3±0.2mV dec-1 and a lifetime of more than 1 year (over 3000 determinations for each membrane). The slope indicates that the ion-selective electrode responds preferentially to the Al(F)4- species. Application of this electrode for the aluminium(III) determination in stomach anti-acid samples is reported.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and didactic experiment was developed for image monitoring of the browning of fruit tissues caused by the enzyme polyphenol oxidase. The procedure, easy and inexpensive, is a valuable tool to teach and demonstrate the redox reaction between the enzyme and the natural polyphenols. To obtain the browning percentage for apple, pear and banana, digital photographs were employed, and the images were analyzed by means of Monte Carlo methods and digital analysis programs. The effects of several experimental conditions were studied, such as pH, light, temperature and the presence of oxygen or anti-oxidants. It was observed that each fruit presented a different condition that better minimized the oxidation process. The absence of oxygen and the application of a bissulphite solution were sufficient to keep the quality of all fruits tested.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple flow injection procedure was developed for determining dipyrone (1-phenyl-2,3-dimethyl-4-methylaminomethano-5-pyrazolone sodium, metamizol, analgin) in pharmaceutical formulations. The determination is based on the reduction of Ag+ ions to Ag0 by dipyrone. A colloidal suspension of Ag0 produced was transported by carrier solution (0.01 mol L-1 NaOH) and turbidimetrically detected at 425 nm. The analytical curve for dipyrone was linear in the range from 5.0 x 10-4 to 2.5 x 10-3 mol L-1 with a correlation coefficient of 0.9990. The detection limit was 1.3 x 10-4 mol L-1 (3sigmaB/slope). The relative standard deviation for ten successive measurements was 1.8% and an analytical frequency of 45 h-1 was obtained. The recovery values from three samples ranged from 96.0 to 102%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An indirect flow injection spectrophotometric procedure is proposed for the determination of N-acetyl-L-cysteine in pharmaceutical formulations. In this system, ferroin ([Fe(II)-(fen)2]2+) in excess, with a strong absorption at 500 nm, is oxidized by cerium(IV) yielding cerium(III) and [Fe(III)-(fen)2]3+ (colorless), thus producing a baseline. When N-acetyl-L-cysteine solution is introduced into the flow injection system, it reacts with cerium(IV) increasing the analytical signal in proportion to the drug concentration. Under optimal experimental conditions, the linearity of the analytical curve for N-acetyl-L-cysteine ranged from 6.5x10-6 to 1.3x10-4 mol L-1. The detection limit was 5.0x10-6 mol L-1and recoveries between 98.0 and 106% were obtained. The sampling frequency was 60 determinations per hour and the RSD was smaller than 1.4% for 2.2x10-5 mol L-1 N-acetyl-L-cysteine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The construction and analytical evaluation of a coated graphite-epoxy electrode sensitive to the zinc-1,10-phenantroline complex based on the [Zn(fen)3][tetrakis(4-chlorophenyl)borate]2 incorporated into a poly(vinylchloride) (PVC) matrix are described. A thin membrane film of this ion-pair, dibutylphthalate (DBPh) and PVC were deposited directly onto an electrically conductive graphite-epoxy support located inside a Perspex® tube. The best PVC polymeric membrane contains 65% (m/m) DBPh, 30% (m/m) PVC and 5% (m/m) of the ion-pair. This electrode shows a response of 19.5 mV dec-1 over the zinc(II) concentration range of 1.0 x 10-5 to 1.0 x 10-3 mol L-1 in 1,10-phenantroline medium, at pH 6.0. The response time was less than 20 seconds and the lifetime of this electrode was more than four months (over 1200 determinations by each polymeric membrane). It was successfully used as an indicator electrode in the potentiometric precipitation titration of zinc(II) ions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow injection turbidimetric procedure exploiting merging zones is proposed for determining homatropine methylbromide (HMB) in pharmaceutical preparations. The determination is based on the precipitation reaction of homatropine methylbromide with AgNO3 solution to form a precipitate, which was measured at 410 nm. The analytical curve was linear in the HMB concentration range from 8.0x10-4 to 1.7x10-3 mol L-1, with a detection limit of 9.5x10-5 mol L-1. The recoveries ranged from 94.9 to 104 %, the sampling frequency was 75 h-1 and relative standard deviations were smaller than 2.0 % for solutions containing 1.2x10-3 and 1.5x10-3 mol L-1 HMB (n=10). The results obtained for commercial formulations using the FIA procedure were in good agreement with those obtained by using a comparative method (r= 0.9983).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A comparison of the phenolic content of several Chilean honeys showed great variations in flavonoid concentration among the samples analysed. Higher amounts of phenolics are found in honey from dry climates. The antioxidant effect of extracts, using ORAC analysis, did not correlate with the flavonoid content or with the total phenolic concentration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work a method was developed for removing metallic ions from wastewaters by co-precipitation of Cu2+, Pb2+, Cd2+, Cr3+ and Hg2+ with chitosan and sodium hydroxide solution. Solutions of these metallic ions in the range from 0.55 to 2160 mg L-1 were added to chitosan dissolved in 0.05 mol L-1 HCl. For the co-precipitation of metal-chitosan-hydroxide a 0.17 mol L-1 NaOH solution was added until pH 8.5-9.5. A parallel study was carried out applying a 0.17 mol L-1 NaOH solution to precipitate those metallic ions. Also, a chitosan solid phase column was used for removing those metallic ions from wastewaters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report a structural study on polycrystalline La0.86Sr0.14Mn1-y Cu yO3+delta samples (y = 0, 0.05, 0.10, 0.15, 0.20) using refinement of powder X-ray diffraction data and analysis of scanning electron microscopy images. It is found that the structure remains rhombohedral through the whole series, with a decrease in the average Mn-Mn bond distances, slight variations in Mn-O-Mn angle and reduction in the unit cell volume with increasing Cu amounts. The values of Mn-Mn distances suggest compact structures with d within ±1%. Scanning electron microscopy images reveal homogeneous microstructure in all samples, besides a trend for smaller grains and larger porosity with increasing Cu content.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electrochemical applications of a CPE modified with chitosan for the determination of Cu(II) in wastewater samples using anodic stripping voltammetry are described. The best voltammetric response was observed for a paste containing 25% m/m of chitosan. A 0.10 mol L-1 NaNO3 solution (pH 6.5) as supporting electrolyte, a pre-concentration potential of -0.20 V, pre-concentration time of 270 s and a scan rate of 25 mV s-1 were selected. The calibration graph was linear in the Cu(II) concentration range from 2.0 x 10-7 to 7.4 x 10-6 mol L-1, with a detection limit of 8.3 x 10-8 mol L-1.