281 resultados para Técnico Análises Clínicas
Resumo:
In the context of quality and good laboratory practices, the article recovers some historical data. From a specific Institutional situation (CPQBA/UNICAMP), is presented an experience of establishing and implementing a standard (NIT-DICLA-035) for good laboratory practice according to definitions of the Brazilian authority (INMETRO) responsible for regulating, monitoring, supervising and recognition in this area. The issue aims to focus on studies of pesticide residues in GLP parameters.
Resumo:
In order to evaluate the effects of environmental factors on the content of secondary metabolites, the chemical profiles of infusions from leaves of seven genotypes of Lippia gracilis Schauer, sourced from two locations (Sergipe and Bahia state) and collected during different seasons: summer (with and without irrigation) and winter, were determined by HPLC-DAD. The fingerprint chromatograms were analyzed by PCA to evaluate similarities and differences among the samples. Results revealed differences among genotypes collected and cultivated under the same conditions, suggesting that three genotypes have greater resistance to drought conditions.
Resumo:
This study validated a simple and applied method for determining mycotoxins aflatoxin B1, aflatoxin B2, ochratoxin A, zearalenone and deoxynivalenol, in water from the rice production chain. Five solvent combinations for extraction were tested, with quantification performed by TLC/HPTLC and confirmation by LC-MS/MS. Mycotoxins in water from field and rice industries were evaluated. Mycotoxin recovery levels were around 90%. Two samples from rice parboiling waste were contaminated (deoxynivalenol/aflatoxin B1, 110/9 ng mL-1; and deoxynivalenol, 100 ng mL-1). Zearalenone, deoxynivalenol and ochratoxin A (36, 30 and 28%) were carried to soaking water during parboiling.
Resumo:
A multi-commuted flow system was developed to determine propylthiouracil (PTU) based on the reaction of its thiol form with iminoquinone radical generated by the oxidation of N,N-dimethyl-p-phenylenediamine in an alkaline medium. PTU can be found in tautomeric forms and the tautomeric equilibrium was displaced to enhance the thiol form. However, the reaction product is unstable and its residence time in the flow path was carefully investigated. The proposed procedure showed good precision (< 1.5%) and a limit of detection (3s) of 0.11 mg L-1. High recoveries were obtained in the validation test. The procedure was employed for propylthiouracil determination in medications.
Resumo:
The need for effective and reliable quality control in products from pharmaceutical industries renders the analyses of their active ingredients and constituents of great importance. This study presents the theoretical basis of ¹H NMR for quantitative analyses and an example of the method validation according to Resolution RE Nº 899 by the Brazilian National Health Surveillance Agency (ANVISA), in which the compound paracetamol was the active ingredient. All evaluated parameters (selectivity, linearity, accuracy, repeatability and robustness) showed satisfactory results. It was concluded that a single NMR measurement provides structural and quantitative information of active components and excipients in the sample.
Resumo:
Two methods using headspace solid-phase microextraction and gas chromatography - mass spectrometry were developed for the determination of polycyclic aromatic hydrocarbons (PAH) and BTEX. Best results were obtained using DVB/CAR/PDMS fiber, with 10 min extraction at 25 °C and 0.15 min desorption at 260 °C (BTEX), and PDMS/DVB fiber, with 60 min extraction at 90 °C, 10% NaCl and 5 min desorption at 270 °C (PAH). LOD intervals were 3x10-2 - 5x10-2 µg L-1 (BTEX) and 1.6x10-3 - 1.4 µg L-1 (PAH). The methods were applied to forty-five groundwater samples from monitoring wells of gas stations and only benzene level exceeded the limit established by Brazilian regulations.
Resumo:
This paper describes the use of the open source hardware platform, denominated "Arduino", for controlling solenoid valves for solutions handling in flow analysis systems. System assessment was carried out by spectrophotometric determination of iron (II) in natural water. The sampling rate was estimated as 45 determinations per hour and the coefficient of variation was lower than 3%. Per determination, 208 µg of 1-10-phenanthroline and ascorbic acid were consumed, generating 1.3 mL of waste. "Arduino" proved a reliable microcontroller with low cost and simple interfacing, allowing USB communication for solenoid device switching in flow systems.
Resumo:
In this work, the spectroscopic properties of 5,10,15,20-tetrakis(4-methoxyphenyl)porphyrin (TMPP) in solvents of different polarities and water/ethanol mixtures were studied by electronic absorption spectroscopy and resonance light scattering associated with statistical analysis. The molar absorption coefficient and emission maximum of TMPP were dependent on solvent polarity. In the water/ethanol mixture, TMPP remained monomeric up to 25% of water, when it reaches its critical aggregation percentage. Oblique head-to-tail aggregate was found at intermediate water content (35 - 55%), while formation of a J-type aggregate was observed at higher water content (> 60%).
Resumo:
The conventional curriculum of Analytical Chemistry undergraduate courses emphasizes the introduction of techniques, methods and procedures used for instrumental analysis. All these concepts must be integrated into a sound conceptual framework to allow students to make appropriate decisions. Method calibration is one of the most critical parameters that has to be grasped since most analytical techniques depend on it for quantitative analysis. The conceptual understanding of calibration is not trivial for undergraduate students. External calibration is widely discussed during instrumental analysis courses. However, the understanding of the limitations of external calibration to correct some systematic errors is not directly derived from laboratory examples. The conceptual understanding of other calibration methods (standard addition, matrix matching, and internal standard) is imperative. The aim of this work is to present a simple experiment using grains (beans, corn and chickpeas) to explore different types of calibration methods.
Resumo:
Numerous investigations are dedicated to the research and development of new polymer materials destined for innovation in pharmaceutical forms. The application of these technological resources has allowed the commercialization of new therapeutic systems for modified drug release. This investigation aimed to evaluate the association of modified chondroitin sulfate with an insoluble polymer, Eudragit® RS 30 D, widely available in the pharmaceutical market. Isolated films were prepared by the evaporation process using a Teflon® plate. The aqueous dispersions (4% m/v) of synthetic polymer received the addition of modified chondroitin sulfate at different ratios. The interactions of the polymer chains in the blends were physicochemically characterized by means of Fourier transform infrared spectroscopy, thermal analyses, differential scanning calorimetry, thermogravimetry and scanning electron microscopy combined with hydration and assays in alkaline pH. The results showed appropriate properties of the coating materials for solid oral forms intended for drug deliver in specific environments.
Resumo:
AbstractA device comprising a lab-made chamber with mechanical stirring and computer-controlled solenoid valves is proposed for the mechanization of liquid-liquid extractions. The performance was demonstrated by the extraction of ethanol from biodiesel as a model of the extraction of analytes from organic immiscible samples to an aqueous medium. The volumes of the sample and extractant were precisely defined by the flow-rates and switching times of the valves, while the mechanic stirring increased interaction between the phases. Stirring was stopped for phase separation, and a precise time-control also allowed a successful phase separation (i.e., the absence of the organic phase in the aqueous extract). In the model system, a linear response between the analytical response and the number of extractions was observed, indicating the potential for analyte preconcentration in the extract. The efficiency and reproducibility of the extractions were demonstrated by recoveries of ethanol spiked to biodiesel samples within 96% and 100% with coefficients of variation lower than 3.0%.
Resumo:
Este trabalho descreve uma revisão a respeito do uso do ligante dietilditiofosfato de amônio em química analítica e suas potencialidades no campo da análise química espectrofotométrica (UV/VIS) e espectrométrica (AAS, ICP-AES, ICP-MS) em diferentes matrizes e meios. A discriminação de espécies químicas por meio de complexações seletivas de elementos químicos com dietilditiofosfato e a hifenação de técnicas espectroscópicas a etapas de separação como extração em fase sólida, extração líquido-líquido, extração por "cloud point", são outros assuntos abordados neste trabalho.
Resumo:
Algumas cepas de algas, em especial as cianobactérias, podem produzir toxinas como as microcistinas, as quais podem ocasionar intoxicação e morte de seres humanos e de animais. A literatura reporta a ocorrência de um acidente em uma clínica de hemodiálise de Caruaru, Pernambuco, aonde vieram a falecer 60 pacientes que faziam hemodiálise, devido à presença da toxina microcistina-LR na água. Nesse estudo foi desenvolvido e validado um método analítico, para a determinação e quantificação da microcistina-LR. A cromatografia líquida de alta performance com detector de UV foi empregada como técnica analítica para a determinação de microcistina-LR. Os parâmetros selecionados para a validação do método foram: linearidade, curva analítica, precisão, sensibilidade e ensaios de recuperação. A curva analítica foi construída com sete pontos a partir do padrão. O método apresentou uma linearidade no intervalo de 0,05 a 5 µg L-1, e o coeficiente de correlação foi superior a 0,99. Com base nestes resultados conclui-se que o método é eficiente e pode ser empregado, em futuras análises, para o monitoramento da microcistina-LR em água utilizada em clínicas de hemodiálise.
Resumo:
Descrevem-se duas experiências realizadas com o objetivo de verificar se estudantes de Medicina de etapas avançadas podem ser utilizados em Osce para avaliar habilidades clínicas básicas de alunos iniciantes. Na primeira experiência, 6 internos e 6 professores avaliaram 59 alunos do currículo tradicional em Osce com 6 estações focadas na anamnese, exame físico e comunicação com o paciente. As notas dadas pelos professores foram maiores que as dos estudantes em todas as estações, exceto uma (comunicação), mas não houve diferenças significantes entre elas, exceto numa estação de exame físico (p < 0,001) (teste de Wilcoxon). Na segunda experiência, 15 internos do currículo tradicional e 9 professores avaliaram 58 estudantes do 1º ano, currículo PBL, em Osce com 3 estações para avaliar anamnese, exame físico e manipulação de luvas esterilizadas. Os estudantes foram pareados aos professores, e cada um fez sua avaliação individualizada usando o mesmo protocolo. Em metade das estações, os valores médios das notas de professores e estudantes foram significativamente diferentes. Isso aparentemente se deveu à variação significativa entre as notas dos professores, o que não ocorreu com relação às notas dadas pelos estudantes avaliadores (p < 0,05) (teste de Wilcoxon e Anova - Turkey, Dunn). Conclui-se que estudantes em fase de treinamento podem ser utilizados como examinadores confiáveis em exame de habilidades clínicas de estudantes iniciantes, sendo que a variabilidade entre as notas que atribuem para a mesma tarefa parece ser inferior à que se verifica nas notas dos professores.
Resumo:
INTRODUÇÃO: As competências necessárias à formação do estudante de Medicina correspondem à aquisição de conhecimentos, habilidade clínica e atitudes que devem ser adquiridas durante o curso e avaliadas pela instituição formadora. Este trabalho objetiva identificar as competências essenciais ao médico para atender crianças e adolescentes e avaliar se os estudantes ao final do curso conseguem executá-las com autonomia e segurança. MÉTODO: As respostas aos quesitos do Questionário de Competências Específicas em Medicina, de 64 professores de Pediatria, 30 médicos e 428 internos, foram comparadas pelo teste t-student. Os internos foram avaliados pelo Osce, e suas notas comparadas com suas respostas ao questionário. A prova escrita e a avaliação em serviço, também utilizadas, foram correlacionadas com o Osce pelo coeficiente de correlação de Pearson. RESULTADOS: O questionário demonstrou boa consistência interna. A comparação das respostas dos três grupos revelou diferenças estatisticamente significativas apenas nos itens relacionados aos procedimentos (p = 0,003). A comparação das respostas dos estudantes com suas notas no Osce mostrou diferenças significativas nos itens sobre aquisição de habilidade clínica. Os estudantes foram bem avaliados na prova escrita e na avaliação em serviço, havendo boa correlação entre elas e o Osce. CONCLUSÕES: Estudantes, professores e médicos apresentam expectativas semelhantes frente às competências essenciais à prática pediátrica. Resultados divergentes nas avaliações demonstram a necessidade de sua utilização conjunta na certificação do estudante.