352 resultados para Tolerância a Pb e Zn
Resumo:
Este estudo teve como objetivo avaliar a divergência genética entre 23 genótipos de castanheira-do-gurgueia, com base em características físicas e químico-nutricionais do fruto. Os frutos foram coletados em áreas de ocorrência natural da espécie no cerrado do sudoeste piauiense. As características físicas analisadas foram: (a) fruto - massa média (MMF); comprimento (CF); largura (LF); espessura (EF), e massa média do pericarpo (MMP); e (b) castanha - massa média (MMC); comprimento (CC); largura (LC), e espessura (EC). As características químico-nutricionais da castanha analisadas foram: gordura (G); proteína bruta (PB); fibra bruta (FB); cinzas (CZ); carboidratos totais (CT); energia (E), e minerais (P, K, Ca, Mg, Mn, Fe, Cu e Zn). A divergência genética foi estimada utilizando a distância generalizada de Mahalanobis (D²) como medida de dissimilaridade. Estimou-se, também, a importância relativa das características na divergência genética. Os métodos de agrupamento utilizados foram de Tocher e UPGMA. Os genótipos apresentaram variabilidade para a maioria das características analisadas. Os genótipos G-17 e G-18 são os mais divergentes, e os genótipos G-3 e G-16 são os mais similares. As características que tiveram as maiores contribuições para a divergência entre os genótipos foram MMP, MMF, E, FB, CT e PB. A castanha-do-gurgueia é uma boa fonte de P, K, Mg, PB, FB, CT e E.
Resumo:
An automatic dispenser based on a flow-injection system used to introduce sample and analytical solution into an inductively coupled plasma mass spectrometer through a spray chamber is proposed. Analytical curves were constructed after the injection of 20 to 750 µL aliquots of a multielement standard solution (20.0 µg L-1 in Li, Be, Al, V, Cr, Mn, Ni, Co, Cu, Zn, As, Se, Sr, Ag, Cd, Ba, Tl, Pb) and the acquisition of the integrated transient signals. The linear concentration range could be extended to ca. five decades. The performance of the system was checked by analyzing a NIST 1643d reference material. Accuracy could be improved by the proper selection of the injected volume. Besides good precision (r.s.d. < 2%), the results obtained with the proposed procedure were closer to the certified values of the reference material than those obtained by direct aspiration or by injecting 125 µL of several analytical solutions and samples.
Resumo:
The multi-element determination of Al, Cr, Mn, Ni, Cu, Zn, Cd, Ba, Pb, SO4= and Cl- in riverine water samples was accomplished by inductively coupled plasma mass spectrometry (ICP-MS). The sample passed through a column containing the anionic resin AG1-X8 and the metals were determined directly. The retained anionic species were eluted and SO4= and Cl- were determined at m/z 48 and 35 correspondent to the ions SO+ and Cl+ formed at the plasma. Accuracy for metals was assessed by analysing the certified reference TM-26 (National Water Research Institute of Canada). Results for SO4= and Cl- were in agreement with those obtained by turbidimetry and spectrophotometry. LOD's of 0.1 µg l-1 for Cd, Ba and Pb; 0.2 µg l-1 for Al, Mn and Cu; 0.5 µg l-1 for Cr; 0.9 for Zn; 2.0 µg l-1for Ni , 60 µg l-1 for S and 200 µg l-1 Cl were attained.
Resumo:
The main obstacle to the use of compost from urban waste in agriculture is the presence of heavy metals. Once in the soil, their effect is accumulative and they may contaminate crops and water. The present study reports the evaluation of the chemical distributions of Cu, Pb, Mn and Zn in three different sized fractions (unsieved, < 1,18mm and > 1,18mm) of compost, by means of a sequencial extraction procedure and a chemometric analysis of the total content of all metals in each fraction. The pattern recognition methods showed significant differences in total heavy metal contents for the different fractions. The finest one was the most contaminated. Meanwhile, this fraction presented lower amounts of metals in avaliable forms. This behavior can be attributed to the presence of metal particles in their elemental states in this fraction.
Resumo:
A column packed with 5-(4-dimethylaminobenzylidene)rhodanine adsorbed on silica gel was used for the preconcentration of Cd, Ni and Zn at different spiked solutions prior to their determination by inductively coupled plasma atomic emission spectrometry. This column allowed recoveries over than 98% for the above elements and accurate analyses of coastal sea-water certified reference material were also achieved.
Resumo:
An on-line electrodissolution procedure implemented in a flow injection system for determination of copper, zinc and lead in brasses alloys by ICP-AES is described. Sample dissolution procedure was carried out by using a PTFE chamber and a DC power supply with constant current. Solid sample was attached to chamber as anode and a gold tubing coupled in the chamber was used as cathode. An electrolytic solution flowing through the gold tubing closed the electric circuit with sample, in order to provide condition for electric dissolution when the DC power supply was switched on. The best results were achieved by using a 1.5 mol l-1 nitric acid solution as electrolyte and a 2.5 A current intensity. The procedure presented a good performance characterized by a relative standard deviation better than < 5% (n=5) and a sample throughput of 180 determinations per hour for Cu, Zn and Pb. Results were in agreement with those obtained by conventional acid dissolution (99% confidence level).
Resumo:
In environmental studies it is necessary to know the adsorption behavior of metals by soils, since the unfavorable effects of heavy metals and even the micronutrients at high concentrations in the environment are related to these adsorbents' ability to immobilize them. A sample of a humic yellow red oxisol from Araponga region in the State of Minas Gerais, Brazil, was used to verify the adsorption behavior of Cu2+ ions in this substrate. The mathematical model described by Langmuir's adsorption equation in its linearized form was applied and the values of the maximum capacity b and those of the constant related to the bonding energy a were obtained. Aliquots of copper nitrate solutions containing several concentrations of this metal were added to soil samples, the pH being predetermined for developing the adsorption experiments. The chemical and physical characterization of soil sample were performed by determining the organic carbon, nitrogen and phosphorus concentrations, cation exchange capacity (CEC), pH, concentration of metals (Al, Fe, K, Mg, Ca, Zn, Cu, Ni, Cr, Co, Pb, and Cd), granulometric analysis and X-ray diffraction. Langmuir isotherms presented two distinct adsorption regions at both pH 4 and pH 5, showing that the adsorptive phenomenon occurs in two distinct stages. The adsorption sites for the lower part presented greater bonding energy and low adsorption capacity compared with the adsorption sites of the part of the curve corresponding to higher Cu concentrations in the equilibrating solution.
Resumo:
This work reviews recent studies of underpotential deposition (UPD) of several metals on Pt and Au substrates performed in the Grupo de Materiais Eletroquímicos e Métodos Eletroanalíticos (IQSC -- USP, São Carlos). The UPD Cu, Cd and Pb on Pt were analysed in terms of their influence in the oxygen evolution reaction. Partial blockage of surface active sites, promoted by Pb ad-atoms, resulted in a change from water to hydrogen peroxide as the final product. The Ag UPD on Pt and Au substrates was also discussed in this work. A detailed model of charge calculation for Ag monolayer was developed and confirmed by the rotating ring-disk data. The partial charge transfer in UPD studies was analysed in the Cd/Pt and Cd/Au systems and a value of 0.5 was found for the adsorption electrovalence of Cd ad-ions. The Sn/Pt UPD systems were studied from the point of view of the valences of metallic ions in solution. The deposition from Sn(IV) generates a full monolayer with a maximum occupation of approximately 40% of the surface active sites (340 µC cm-2) plus 105 µC cm-2 of Hads (half monolayer). Changing the metallic ion for Sn(II), it was possible to deposit a full monolayer (210 µC cm-2) without any detectable Hads. Finally, the effect of anions was discussed in the Zn/Pt and Zn/Au systems. Here, the hydrogen evolution reaction (her) and the hydrogen adsorption/desorption were used in order to investigate the maximum coverage of the surface with Zn ad-atoms. The full monolayer, characterised by the complete absence of Hads, was achieved only in 0.5 M HF solutions.
Resumo:
The aquatic humic substances (AHS) investigated in this study were conventionally isolated from Rio Negro waters - Amazonas State/Brazil by means of the collector XAD 8. A special five-stage tangential-flow ultrafiltration device was used for analytical fractionation of AHS. The fractionation patterns (6 fractions each) showed that metal traces remaining in AHS after their XAD 8 isolation have different size distributions. For instance, the major percentage of traces of Ni, Cu, Zn, Cd and Pb (determined using ICP-AES) was preferably complexed by molecules with relatively high molecular size (30-100 kDa) and the following complexation order was characterized: F2 >> F1 = F4 = F5 > F3 > F6. Moreover, the species formed between AHS and metals prepared by spiking, showed distribution patterns changing as a function of the complexation time (ageing process), indicating a slow transformation process and an inner rearrangements in the binding sites within the AHS molecules.
Resumo:
In order to demonstrate the feasibility of slurry sampling for environmental studies, different methodologies were developed for Cu and Zn in antarctic limpets and Ni in river sediment with FAAS detection. Studies focusing particle size, acid concentration, slurry stability, selectivity, among others were carried out in order to define the better conditions for slurry analysis. A study related to the depth profile for Ni in the Atibaia River sediment was made after optimization conditions for this element. For accuracy check, certified reference material was used as well as decomposition with microwave oven.
Resumo:
This work describes a factorial design for the optimization of pyrolysis and atomization temperatures in ETAAS. As examples, Cd and Pb were determined using lower pyrolysis and atomization temperatures and Al and Mo with higher pyrolysis and atomization temperatures. Good results were obtained for Cd employing Rh (m o = 1.4 pg) as a permanent modifier with pyrolysis and atomization temperatures of 640 and 1500 °C, respectively. For Zr, W or Zr+W, the Cd pyrolysis and atomization temperatures were 500 and 1500 °C, respectively, with m o = 1.4 pg using Zr or W and 1.5 pg using Zr+W. The best results for Pb were those using Rh, Zr, W and Zr+Rh, obtaining characteristic masses of 42, 37, 34 and 36 pg, respectively. Pyrolysis and atomization temperatures of 910 and 1850 °C, respectively, were achieved for this metal. For Al, the best results were obtained when Zr or Zr+W were used. Mo was also tested as a possible permanent modifier for Al, but the results were not satisfactory. The results obtained for Mo without modifier were similar to those with conventional modifiers (Mg or Pd+Mg) and the results obtained using permanent chemical modifiers were not satisfactory. In all situations, the experiments were performed faster than those using the univariate procedure.
Resumo:
The aim of this work was to explore the possibility of the application of a non-ionic resin obtained by impregnation of Alizarin Red S (VAS) in Amberlite XAD-7 for manganese, copper and zinc separation and preconcentration in saline matrices. For these system, the metals were quantitatively retained, in the pH range 8.5-10.0, by using 0.50 g of solid phase, stirring time of five minutes and a total mass up to 200 mug of each cation. The sorbed elements were subsequently eluted and a fifty-fold, ten-fold and ten-fold preconcentration factor for to Zn, Cu and Mn were obtained, respectively.
Resumo:
Some commercial samples of vermicompost from bovine manure (humus) were characterized by thermogravimetry with respect to humidity, organic matter and ash contents, the percentages of which range from 6.55 to 5.35%, 53.01 to 69.96% and 46.44 to 66,14%, respectively. The capacity of adsorption of Cu2+, Zn2+ and Co2+ ions by these samples has been evaluated as a function of pH and time. The contents of several metal ions in the original vermicompost samples have been determined by flame atomic absorption spectrometry after digestion in a microwave oven. The high nitrogen content suggests that the earthworms used in the maturation procedure lead to an efficient degradation of organic matter. The metal retention was affected by both pH and adsorption time. The results also show that adsorption follows the order Cu2+ > Zn2+ > Co2+.
Resumo:
Thermal decomposition of [Bu4N]2[Zn(imnt)2] and [M(NH3)2(imnt)] complexes with M = Zn and Cd, and imnt = (bis 1,1-dicyanoethylene-2,2 dithiolate) in inert atmosphere was investigated by thermogravimetric analysis (TG) and differential scanning calorimetry (DSC). Pyrolysis studies at different temperatures, 300, 400, 500, and 600 ºC, in N2 atmosphere were performed and the products were characterized by X-ray diffraction (XRD), infrared and Raman spectroscopy, and scanning electron microscopy (SEM). The products were identified as sulfide sub-micron particles, along with amorphous carbon. Particle sizes estimated by SEM were ca. 50 nm for the cationic complexes and 500 nm for the neutral complexes.
Resumo:
The construction and analytical evaluation of a coated graphite-epoxy electrode sensitive to the zinc-1,10-phenantroline complex based on the [Zn(fen)3][tetrakis(4-chlorophenyl)borate]2 incorporated into a poly(vinylchloride) (PVC) matrix are described. A thin membrane film of this ion-pair, dibutylphthalate (DBPh) and PVC were deposited directly onto an electrically conductive graphite-epoxy support located inside a Perspex® tube. The best PVC polymeric membrane contains 65% (m/m) DBPh, 30% (m/m) PVC and 5% (m/m) of the ion-pair. This electrode shows a response of 19.5 mV dec-1 over the zinc(II) concentration range of 1.0 x 10-5 to 1.0 x 10-3 mol L-1 in 1,10-phenantroline medium, at pH 6.0. The response time was less than 20 seconds and the lifetime of this electrode was more than four months (over 1200 determinations by each polymeric membrane). It was successfully used as an indicator electrode in the potentiometric precipitation titration of zinc(II) ions.