277 resultados para Heat-resistant Proteases
Resumo:
ABSTRACT Given the need to obtain systems to better control broiler production environment, we performed an experiment with broilers from 1 to 21 days, which were submitted to different intensities and air temperature durations in conditioned wind tunnels and the results were used for validation of afuzzy model. The model was developed using as input variables: duration of heat stress (days), dry bulb air temperature (°C) and as output variable: feed intake (g) weight gain (g) and feed conversion (g.g-1). The inference method used was Mamdani, 20 rules have been prepared and the defuzzification technique used was the Center of Gravity. A satisfactory efficiency in determining productive responses is evidenced in the results obtained in the model simulation, when compared with the experimental data, where R2 values calculated for feed intake, weight gain and feed conversion were 0.998, 0.981 and 0.980, respectively.
Resumo:
ABSTRACT Global warming increases the occurrence of events such as extreme heat waves. Research on thermal and air conditions affecting broiler-rearing environment are important to evaluate the animal welfare under extreme heat aiming mitigation measures. This study aimed at evaluating the effect of a simulated heat wave, in a climatic chamber, on the thermal and air environment of 42-day-old broilers. One hundred and sixty broilers were housed and reared for 42 days in a climatic chamber; the animals were divided into eight pens. Heat wave simulation was performed on the 42nd day, the period of great impact and data sampling. The analyzed variables were room and litter temperatures, relative humidity, concentrations of oxygen, carbon monoxide and ammonia at each pen. These variables were assessed each two hours, starting at 8 am, simulating a day heating up to 4 pm, when it is reached the maximum temperature. By the results, we concluded that increasing room temperatures promoted a proportional raise in litter temperatures, contributing to ammonia volatilization. In addition, oxygen concentrations decreased with increasing temperatures; and the carbon monoxide was only observed at temperatures above 27.0 °C, relative humidity higher than 88.4% and litter temperatures superior to 30.3 °C.
Resumo:
The animal reservoirs of vancomycin-resistant enterococci (VRE) have important role in the epidemiology of the bacteria and resistant genes. The present work searched fecal samples taken off nonhuman primates for the presence of VRE. Resistance profiles, virulence traits, and genetic variability among enterococci isolates were also analyzed. The samples included Capuchin monkeys (Cebus apella, n=28) and Common marmoset (Callithrix penicillata, n=37) housed in the Primate Center of the University of Brasília, Brazil. Most individuals were captive monkeys from the Central-West and South-East regions of Brazil (n=48). We collected rectal swabs and carried out selective isolation followed by multiplex Polymerase Chain Reaction (PCR) to identify species and resistance genes. No vanA or vanB-containing enterococci were found. The carriage rates ranged from 1.5% for the VanC-type E. casseliflavus and E. gallinarum until 12.3% (n=8) for Enterococcus faecalis. All E. faecalis isolates showed susceptibility to vancomycin, teicoplanin, ampicillin, gentamicin, and streptomycin. The virulence genes ace and esp were prevalent (100.0%, 87.5%). Multilocus variable number of tandem repeats (MLVA) revealed diversity in the number of repeats among E. faecalis isolates and targets, which was higher for espC, efa5, and efa6. We identified six different MLVA genotypes that were divergent from those described in human beings. Also, they were clustered into two genogroups that showed host-specificity for the species Cebus apella or Callithrix penicillata. In conclusion, no vanA- or vanB-containing enterococci were found colonizing those primate individuals. This finding suggested that the primate individuals investigated in our study are not directly involved in the epidemiological chain of high-level vancomycin-resistant genes vanA or vanB in Brazil. Our study also showed that E. faecalis isolated from nonhuman primates carry virulence traits and have ability to spread their lineages among different individuals.
Resumo:
Recent advances in anthelmintic resistant phenotype reversion by Pgp modulating drugs in ruminant nematodes indicate that this can be a useful tool to helminth control. The aim of the present study was to evaluate the efficacy of ivermectin (IVM) in combination with verapamil (VRP), in oil or water-based vehicle, against an IVM-resistant field isolate of Haemonchus contortus through a larval migration assay and experimental infection trial. In the in vitro assay was observed a phenotypic reversion of H. contortus resistance to ivermectin at a high concentration of VRP, increasing IVM efficacy from 53.1% to 94.3. In the in vivo trial, IVM + VRP demonstrated 36.02% efficacy compared to the 7.75% of IVM alone. The vehicle formulation showed no influence in efficacy. These are the first results demonstrating the effect of VRP as a partial IVM-resistance phenotype reverser in a field isolate of IVM-resistant H. contortus experimentally inoculated in sheep.
Resumo:
The aim was to evaluate for 75 days the impact on production of the remaining burden of ivermectin (IVM)-resistant parasites in naturally infected feedlot calves. The herds came from tick-infested areas of cattle breeding where the systematic use of IVM to control tick increases the gastrointestinal parasites resistant to this drug. This investigation was carried out in two commercial feedlots in Buenos Aires province. In feedlot A, two groups of 35 animal each received IVM 1% and the other received ricobendazole (RBZ) 10% respectively. The same was done in feedlot B. On day 0, two groups of 35 animals were made in feedlots A and B. Fecal samples were taken on days 0, 22, 54 and 75 pos-treatment (PT), and body weight was registered, from each animal. Fecal samples were processed for individual count of eggs per gram (EPG) and pooled fecal culture was carried out for identification of the parasite genus in each sampling. Fecal egg count reduction test (FECR) was calculated on day 22 PT. The study design used was a totally randomized block, with commercial feedlot and sex as block variables. For data analysis, a mixed model of the SAS statistical program was used. The FECR average on day 22 was 28.4% in the IVM group, and 94,2 % in the RBZ group . From this date on, significant differences in EPG were kept until day 54. EPG counts were only equal near the end of the trial, on day 75 (p=0.16). In both commercial feedlots, especially in the IVM group, Cooperia spp. was the most prevalent parasite in the fecal cultures. Significant differences in weight (P<0.01) on post-treatment day 75 was found between the average weight in the RBZ and the IVM group (246 vs. 238 kg respectively), what means a difference of 8.3% in gains. The importance for production in the antiparasite failure treatment in commercial feedlots was demonstrated, and the need of pos-treatment controls to evaluate the efficacy of the antiparasitic administered is emphasized.
Resumo:
The objective of the present work is the experimental determination of pressure drop coefficients (loss coefficients) for elliptic and circular sections in one, two and three-row arrangements of plate fin and tube heat exchangers. The experiments permitted to correlate the dimensionless loss coefficient with the flow Reynolds number in the rectangular channel formed by the plate fins. The experimental technique consisted of the measurement of the longitudinal pressure distribution along the flow channel, for several values of air mass flow rate. The total number of data runs, each one characterized by the flow Reynolds number, was 216. The present geometry is used in compact heat exchangers for air conditioning systems, heaters, radiators, and others. Also, it is verified the influence of the utilization of elliptic tubes, instead of circular ones, in the pressure drop. The measurements were performed for Reynolds numbers ranging from 200 to 1900.
Resumo:
Experiments were performed to determine average heat transfer coefficients and friction factors for turbulent flow through annular ducts with pin fins. The measurements were carried out by means of a double-pipe heat exchanger. The total number of pins attached to the inner wall of the annular region was 560. The working fluids were air, flowing in the annular channel, and water through the inner circular tube. The average heat transfer coefficients of the pinned air-side were obtained from the experimental determination of the overall heat transfer coefficients of the heat exchanger and from the knowledge of the average heat transfer coefficients of the circular pipe (water-side), which could be found in the pertinent literature. To attain fully developed conditions, the heat exchanger was built with additional lengths before and after the test section. The inner circular duct of the heat exchanger and the pin fins were made of brass. Due to the high thermal conductivity of the brass, the small tube thickness and water temperature variation, the surface of the internal tube was practically isothermal. The external tube was made of an industrial plastic which was insulated from the environment by means of a glass wool batt. In this manner, the outer surface of the annular channel can be considered adiabatic. The results are presented in dimensionless forms, in terms of average Nusselt numbers and friction factors as functions of the flow Reynolds number, ranging from 13,000 to 80,000. The pin fin efficiency, which depends on the heat transfer coefficient, is also determined as a function of dimensionless parameters. A comparison of the present results with those for smooth sections (without pins) is also presented. The purpose of such a comparison is to study the influence of the presence of the pins on the pressure drop and heat transfer rate.
Resumo:
This work studies the forced convection problem in internal flow between concentric annular ducts, with radial fins at the internal tube surface. The finned surface heat transfer is analyzed by two different approaches. In the first one, it is assumed one-dimensional heat conduction along the internal tube wall and fins, with the convection heat transfer coefficient being a known parameter, determined by an uncoupled solution. In the other way, named conjugated approach, the mathematical model (continuity, momentum, energy and K-epsilon equations) applied to tube annuli problem was numerically solved using finite element technique in a coupled formulation. At first time, a comparison was made between results obtained for the conjugated problem and experimental data, showing good agreement. Then, the temperature profiles under these two approaches were compared to each other to analyze the validity of the one-dimensional classical formulation that has been utilized in the heat exchanger design.
Resumo:
In nuclear reactors, the occurrence of critical heat flux leads to fuel rod overheating with clad fusion and radioactive products leakage. To predict the effects of such phenomenon, experiments are performed using electrically heated rods to simulate operational and accidental conditions of nuclear fuel rods. In the present work, it is performed a theoretical analysis of the drying and rewetting front propagation during a critical heat flux experiment, starting with the application of an electrical power step from steady state condition. After the occurrence of critical heat flux, the drying front propagation is predicted. After a few seconds, a power cut is considered and the rewetting front behavior is analytically observed. Studies performed with various values of coolant mass flow rate show that this variable has more influence on the drying front velocity than on the rewetting one.
Resumo:
This paper deals with the use of the conjugate gradient method of function estimation for the simultaneous identification of two unknown boundary heat fluxes in parallel plate channels. The fluid flow is assumed to be laminar and hydrodynamically developed. Temperature measurements taken inside the channel are used in the inverse analysis. The accuracy of the present solution approach is examined by using simulated measurements containing random errors, for strict cases involving functional forms with discontinuities and sharp-corners for the unknown functions. Three different types of inverse problems are addressed in the paper, involving the estimation of: (i) Spatially dependent heat fluxes; (ii) Time-dependent heat fluxes; and (iii) Time and spatially dependent heat fluxes.
Resumo:
In this work, we present the solution of a class of linear inverse heat conduction problems for the estimation of unknown heat source terms, with no prior information of the functional forms of timewise and spatial dependence of the source strength, using the conjugate gradient method with an adjoint problem. After describing the mathematical formulation of a general direct problem and the procedure for the solution of the inverse problem, we show applications to three transient heat transfer problems: a one-dimensional cylindrical problem; a two-dimensional cylindrical problem; and a one-dimensional problem with two plates.
Resumo:
In this work it is presented a systematic procedure for constructing the solution of a large class of nonlinear conduction heat transfer problems through the minimization of quadratic functionals like the ones usually employed for linear descriptions. The proposed procedure gives rise to an efficient and easy way for carrying out numerical simulations of nonlinear heat transfer problems by means of finite elements. To illustrate the procedure a particular problem is simulated by means of a finite element approximation.
Resumo:
In two-phase miniature and microchannel flows, the meniscus shape must be considered due to effects that are affected by condensation and/or evaporation and coupled with the transport phenomena in the thin film on the microchannel wall, when capillary forces drive the working fluid. This investigation presents an analytical model for microchannel condensers with a porous boundary, where capillary forces pump the fluid. Methanol was selected as the working fluid. Very low liquid Reynolds numbers were obtained (Re~6), but very high Nusselt numbers (Nu~150) could be found due to the channel size (1.5 mm) and the presence of the porous boundary. The meniscus calculation provided consistent results for the vapor interface temperature and pressure, as well as the meniscus curvature. The obtained results show that microchannel condensers with a porous boundary can be used for heat dissipation with reduced heat transfer area and very high heat dissipation capabilities.
Resumo:
Herbicide resistance was reported in Brazil almost ten years ago. One of the main weeds with herbicide resistance is wild poinsettia (Euphorbia heterophylla). This work evaluates the distribution of ALS-resistant E. heterophylla in two states in southern Brazil and determines the major contributing management causes for weed resistance selection in the area. E. heterophylla seeds from 148 sites located in Paraná and Rio Grande do Sul were sampled during 2001 and 2002. Farmers provided specific site data for weed control, tillage system, crop rotation and harvesting operations during previous years. ALS resistant E. heterophylla biotypes were found widely distributed in the survey area. Data analysis suggests seed dissemination is unlikely to explain the widespread distribution of resistance. The most probable factor for the selection of the resistant E. heterophylla is the persistent high use of ALS-inhibiting herbicides over time. Indirect evidence is presented demonstrating the need to educate legislators and farmers about the importance of herbicide mixtures as a strategy to prevent herbicide resistance.
Resumo:
The continuous use of ALS-inhibiting herbicides has led to the evolution of herbicide-resistant weeds worldwide. Greater beggarticks is one of the most troublesome weeds found in the soybean production system in Brazil. Recently, a greater beggarticks biotype that is resistant (R) to ALS inhibitors due to Trp574Leu mutation in the ALS gene was identified. Also, the adaptive traits between susceptible (S) and R to ALS inhibitors biotypes of greater beggarticks were compared. Specifically, we aimed to: (1) evaluate and compare the relative growth rates (RGR) between the biotypes; (2) analyze the seed germination characteristics of R and S biotypes under different temperature conditions; and (3) evaluate their competitive ability in a replacement series study. The experiments were conducted at the University of Arkansas, USA, in 2007 and at Universidade Federal do Rio Grande do Sul (Federal University of Rio Grande do Sul), Brazil, in 2008. Plant proportions for replacement series studies were respectively 100:0, 75:25, 50:50, 25:75 and 0:100, with a total population of 150 plants m-2. There was no difference in RGR between R and S biotypes. The R-biotype germination rate was lower than that of the S biotype. However, at low temperature conditions (15 ºC), the reverse was observed. In general, there is no difference in the competitive ability between R and S greater beggarticks biotypes.