287 resultados para Construção relativa


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A CPC (Compound Parabolic Concentrator) reactor was projected and constructed aiming to promote the degradation of the organic matter present in considerable volumes of aqueous effluents, under the action of solar radiation. The essays were done using a model effluent which consists of a mixture of fragments of a sodium salt of lignosulphonic acid possessing a mean molecular weigth of 52,000 Daltons, and a real effluent, from a chip board industry. The volume of effluent in each test was about 50 L. The tests involved heterogeneous (TiO2 P25 Degussa and formulations made from the association of TiO2 with a photosensitiser), and homogeneous (thermal and photochemical Fenton reactions) catalysis of the effluents. The results demonstrate the viability of application of this kind of reactor even when the load of organic pollutants is high.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The behaviour of Nafion® polymeric membranes containing acid-base dyes, bromothymol blue (BB) and methyl violet (MV), were studied aiming at constructing an optical sensor for pH measurement. BB revealed to be inadequate for developing sensing phases due to the electrostatic repulsion between negative groups of their molecules and the negative charge of the sulfonate group of the Nafion®, which causes leaching of the dye from the membrane. On the other hand, MV showed to be suitable due to the presence of positive groups in its structure. The membrane prepared from a methanolic solution whose Nafion®/dye molar ratio was 20 presented the best analytical properties, changing its color from green to violet in the pH range from 0.6 to 3.0. The membrane can be prepared with good reproducibility, presenting durability of ca. 6 months and response time of 22 s, making possible its use for pH determination in flow analysis systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we present a new parametrization in molecular mechanics for studying iron complexes. This force field was implemented in the FORCES 2000 program, developed in our group for studying in coordination compounds of interest in bioinorganic chemistry. Mononuclear and dinuclear iron complexes were studied using this program with good success.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new passive sampling system for monitoring NO2 in air has been developed to measure gas concentrations in indoor and outdoor air. The sampler is inexpensive, and easy to construct and operate. Nitrogen dioxide forms a derivative after reaction with a filter coated with triethanolamine and ethyleneglycol. The nitrogen dioxide derivative is extracted from the filter, and the concentration is determined by colorimetry. To test the sampler for measuring ambient level nitrogen dioxide, measurements were carried out inside homes and in a range of workplace environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biosensors were developed by immobilization of gilo (Solanum gilo) enzymatic extract on chitosan biopolymers using three different procedures: glutaraldehyde, carbodiimide/glutaraldehyde and epichlorohydrin/glutaraldehyde. The best biosensor performance was obtained after the immobilization of peroxidase on chitosan with epichlorohydrin/glutaraldehyde. Linear analytical curves for hydroquinone concentrations from 2.5x10-4 to 4.5x10-3 mol L-1 with a detection limit of 2.0x10-6 mol L-1 and recovery of hydroquinone ranging from 95.1 to 105% were obtained. The relative standard deviation was < 1.0 % for a solution of 3.0x10-4 mol L-1 hydroquinone and 2.0x10-3 mol L-1 hydrogen peroxide in 0.1 mol L-1 phosphate buffer solution at pH 7.0 (n=8). The lifetime of this biosensor was 6 months (at least 300 determinations).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The discussion among teachers, students, and technicians about the destination of residues from chemistry laboratories led to a research project whose results were incorporated into a course in its daily practices. The treatment of the residues from argentimetric practices allowed us to establish cognitive relations of technological basis and of those related to the rising of the level of awareness about environmental aspects and social responsibility of chemistry professionals. The techniques and the results, from the economic point of view, namely that of value aggregation (metallic silver) and the conversion of the residue into input (potassium chromate solution) are shown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and low-cost flow cell with 30 cm optical path for spectrophotometric measurements is described. It presents desirable characteristics such as low attenuation of the radiation beam and internal volume (75 µL) comparable to that of a 1-cm conventional cell (80 µL). Despite the increase in optical path, the effect on sample dispersion was also similar to that attained in the commercial cell. The performance of the cell was assessed by the determination of phosphate based on the molybdenum blue method, yielding a linear response range between 0.05 and 0.8 mg L-1 phosphorus (r=0.999). The increase in sensitivity (30.4-fold) in comparison with that obtained with a conventional 1-cm flow cell agreed with that estimated by the Lambert-Beer law.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The assembly of a photochemical reactor with six fluorescent lamps, used for photopolymerizations is described. This chamber presents a mobile support, allowing the placement of samples at different heights and a safety lock that interrupts the radiation, if it is opened during operation. The mirrored internal walls avoid the dispersion and non-uniform distribution of light. There is no high heating because the own character of the used lamps. All parts could be purchased in commerce with less than U$ 150,00. This reactor was successfully used for monolithic stationary phase photopolymerization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes a projection spectrograph for use in optical spectroscopy classrooms demonstrations. The apparatus is based on an overhead projector and permits the visualization of several phenomena such as, light dispersion by diffraction gratings, diffraction order, optical fluorescence, continuous and discrete optical emission spectra, and light absorption by liquids and solids. A historical survey about the optical spectroscopy development is also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vacuum pumps are very useful in physical, chemical and biological experiments. In this communication it is described the design of a compact and low cost water recirculating system employing a water-jet aspirator pump as the vacuum source. The system requires only a water pump, water-jet aspirator pump, commercial PVC water tubes and a drain connection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This works proposes a homemade construction of a lead(II) ISE of solid membrane (Ag2S/PbS) to determine Pb2+ ions in potentiometric titrations, using damaged combined glass electrodes. This electrode can be constructed in teaching laboratories, using it as a learning tool related to the theoretical principle of ISE. The analytical curve obtained (y = 27.056x + 337.58; R = 0.996) was linear on the range of 1 x 10-5 to 1 mol L-1 and has presented a very close behavior of the Nernstian. The homemade ISE has presented a similar selectivity to the commercial electrodes, showing to be a good alternative to the experimental activities on teaching laboratories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biosensors based on laccase immobilized on microparticles of chitosan crosslinked with tripolyphosphate (biosensor I) and glyoxal (biosensor II) obtained by spray drying for the determinations of rutin in pharmaceutical formulations were developed. Under optimized operational conditions (pH 4.0, frequency of 30 Hz, pulse amplitude of 40 mV and scan increment of 2.0 mV) two analytical curves were obtained for both biosensors showing a detection limit of 6.2x10-8 mol L-1 for biosensor (I) and 2.0x10-8 mol L-1 for biosensor (II). The recovery of rutin from pharmaceutical sample ranged from 90.7 to 105.0% and the lifetime of these biosensors were 4 months (at least 400 determinations).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The high cost of sensitivity commercial calorimeters may represent an obstacle for many calorimetric research groups. This work describes the construction and calibration of a batch differential heat conduction calorimeter with sample cells volumes of about 400 μL. The calorimeter was built using two small high sensibility square Peltier thermoelectric sensors and the total cost was estimated to be about US$ 500. The calorimeter was used to study the excess enthalpy of solution of binary mixtures of liquids, as a function of composition, for the following binary systems of solvents: water + 1,4-dioxane or + dimethylsulfoxide at 298,2 ± 0,5 K.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work describes a low-cost electrochemical "wall-jet" detector for flow analysis. The electrolytic solution enters into the cell through a tube of stainless steel (200 to 300 µm i.d), reaching to the center of the working electrode perpendicularly and then being mixed to the remaining solution in the cell, which flows under atmospheric pressure into a waste reservoir. The proposed electrochemical detector can be used with any type of working electrode, from commercial to home-made, such as glassy carbon and metallic electrodes (modified or unmodified), which enlarge the applications of the electrochemical detector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a project, construction and test of a low cost air pycnometer, developed to be used preferentially in pharmaceutical research. A complete discussion of the construction, test and calibration of this equipment is presented and some measurements are made using pharmaceutical powders and dry granulations. The equipment performance has been estimated through its calibration curve, and the obtained value to its volume resolution is about 1%. This equipment is accomplished at the Applied Nuclear Physics Laboratory of University of Sorocaba (LAFINAU) in Sorocaba, SP, Brazil and it was denominated "Picnômetro a Ar Uniso - PICNAU".