339 resultados para IPNV detection
Resumo:
Transmission electon microscopy has been employed for the rapid detection of mycoplasma in sera and cell cultures. High speed centrifugation of sera or low speed centrifugation of cell debris, followed by negative staining of the resuspended pellet, detected mycoplasma contamination more frequently than a culture method followed by direct fluorescence (DAPI), which was used as a control procedure. The appearance of the mycoplasma cell border and content gives some information about particle viability.
Resumo:
The presence of viral antigen in sections from formalin-fixed and paraffin-embedded human tissues was demonstrated by trypsin digestion followed by direct or indirect immunofluorescence. The specimens may be used for retrospective diagnosis. The immunofluorescence technique has to be adapted to the suspected virus infection on the basis of previous histopathology study. Variations of trypsin concentration time and temperature of incubation, expose different viral antigens and have to be previously tested for each unknown system. For measles virus detection in lung a stronger digestion has to be applied as compared to adenovirus or respiratory disease viruses in the same tisue. Flavivirus in liver tissue needs a weaker digestion. The reproducibility of the method makes it useful as a routine technique in diagnosis of virus infection.
Resumo:
This paper presents the evaluation of an enzyme immunoassay in which Mayaro virus-infected cultured cells ara used as antigen (EIA-ICC) and an IgM antibody capture ELISA (MAC-ELISA) for Mayaro serologic diagnosis using 114 human sera obtained during a Mayaro outbreak occurred in Bolivia, in 1987. Results were compared with those obtained by haemagglutination-inhibition test (HAI). MAC-ELISA was the most sensitive technique for anti-Mayaro IgM detection. MAC-ELISA was twice sensitive as IgM EIA-ICC. The data shows that MAC-ELISA is a practical and valid technique for diagnosis of recent mayaro infection. IgG-ICC showed hight sensitivity and high specificity compared to HAI. The combination of anti-Mayaro IgG and IgM EIA-ICC results presented the highest sensitivity of the study. Anti-Mayaro IgG and IgM simultaneous detection by ELISA-ICC can be used for recent infection diagnosis (in spite of a less sensitive IgM detection than by MAC-ELISA), for surveillance and sero-epidemiologic studies, and for studies of IgG and IgM responses to Mayaro infection.
Resumo:
A simple and rapid staphylococcal coagglutination test for the detection of Toxoplasma gondii antigens in mice urine is described. A suspension of protein-A containing Staphylococcus aureus coated with rabbit hyperimmune serum was used as reagent. The sensitivity of the antigen assay was found to be at least 118 ng of the antigen protein per ml. No coagglutination was observed when the reagent was challenged against antigenic solutions of other parasites. The suitability of the method for detecting antigens of T. gondii in urine samples was studied by experimental toxoplasma infection in mice. Before the staphylococcal test, the urine samples were double serially diluted in 0.1 M PBS. From the second day on all samples from infected mice were positive at 1/16 dilution. At this dilution, all samples from non infected mice were negative or did not produce coagglutination. This method might be used in the rapid etiological diagnosis also in human cases of acute toxoplasmosis.
Resumo:
Two practical field methods for indirect detection of simuliid populations resistant to temephos are proposed. The first is based on high esterase activity in resistant larvae and involves adaptations of a filter paper test in which faintly stained spots indicate susceptible populations and strongly stained ones reveal populations resistant to temephos. The second is based on the resistance to the larvicide when adults are topically exposed, and involves the use of diagnostic doses obtained by the comparison between the LD50 for susceptible and resistant populations. The relevance of such methods is discussed in order to help resistance detection in Simulium pertinax Kollar control programmes.
Resumo:
An indirect haemagglutination (IH) test is described for the detection of Clostridium perfringens type A enterotoxin, produced by strains isolated from human cases of food poisoning and from contaminated food. Though no strict relationship could be observed between titers in the IH test and the time it took mice to die from the intravenous inoculation of mice (IIM), results of the supernatants examined by both methods demonstrated that the IH test was more sensitive than the ILM one. No unspecific reaction was obtanined int he IH wirh a negative control and the inhibitions of the IH and IIM tests by specific antiserum against C. perfringens enterotoxin showed that the IH test is very spcific. The IH assay is recommended for its sensitivity and easy performance by less-equipped laboratories, by these and other data.
Resumo:
The passive haemagglutination (PHA) test, enzyme-linked immunosorbent assay (ELISA) and the dot enzyme-immunosorbent assay (DOT-ELISA) were used to detect the levels of IgG antibodies against the Fraction 1 (F1) antigen of Yersinia pestis in sera of plague-infected patients from Northeast Brazil. Twenty three selected PHA-positive sera of subjects with bacteriological confirmation of plague were also positive in the DOT-ELISA but only 19 were detected by the conventional ELISA technique. Another group of 186 serum samples from subjects diagnosed as plague-infected by clinical and epidemiological parameters, but PHA-negative, were screened with DOT-ELISA and 11 gave positive results. The specificity of the assays on the serological detection of plague was confirmed in inhibition tests using purified F1 antigen. These results suggest that DOT-ELISA can be an useful, simple and more sensitive alternative for the serodiagnosis of plague in Northeast Brazil.
Resumo:
Immunofluorescence and immunoperoxidase test directed against early viral antigens, and DNA-DNA hybridization were compared with viral isolation for their abilities to detect Cytomegalovirus (CVM) in the urine of 89 HIV infected patients. From the 100 urine samples collected, 70 were found positive by at least one method. Considering viral isolation as the "gold standard" technique, immunofluorescence and immunoperoxidase had a sensitivity of 92.3% and88% respectively, with a specificity in both cases of 95%. DNA-DNA hybridization showed a sensitivity of 90% but with lower (60%) specificity. All of the three assays were effective in detecting CVM from urine and the technical advantage of each is discussed.
Resumo:
The present report describes an alternative method for in vitro detection of HIV-1 -specific antibody secretion in 24h of culture employing as stimulant of peripheral blood mononuclear cells the disrupted inactivated whole virus adsorbed onto microwells in a commercial ELISA kit plates. The results obtained from this technique have showed high sensitivity and specificity since it was capable of detecting HIV-1 infection early after birth. There were neither false-positivity nor false-negativity when blood samples obtained from HIV-1 seronegative asymptomatic individuals, and HIV-1 seropositive adult patients were analized. This rapid, low cost, simple, highly sensitive and specific assay can be extremely useful for early diagnosis of pediatric HIV infection.