245 resultados para fluido oral


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Under the chromatographic point of view, the physico-chemical properties of a supercritical fluid are intermediate to those of the gases and liquids. Many times they approach the best features of each one, as for example, the solubilization power of liquids and low viscosity of gases. The thermodynamic definitions and main physico-chemical features of a supercritical fluid will be presented in this article. The use of supercritical fluids in analytical chemistry has been extremely modest in Brazil, even considering the enormous potential of their applications, and their use in several techniques, such as chromatography (SFC) and supercritical fluid extration (SFE). This article series is intended to discuss the historical evolution, instrumentation features and potential and limitations of the supercritical fluid use in analytical chemistry. A special focus will be centered on chromatography and extration techniques using supercritical fluids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Six supercritical fluid extraction (SFE) methods were tested, by varying the following operational parameters: CO2 pressure, time and temperature of extraction, type and proportion of static modifier, and Hydromatrix®/sample rate into cell. Firstly, insecticide carbamates were extracted from spiked potatoes samples (fortification level of 0,5 mg.Kg-1) by using SPE procedures, and then final extracts were analyzed HPLC/fluorescence. Good performance was observed with SFE methods that operated with values of temperature and CO2 pressure of 50 ºC and 350 bar, respectively. Best efficiency was obtained when it was used acetonitrile as a modifier (3% on the cell volume), and Hydromatrix®/sample rate of 2:1. Static time was of 1 min; total extraction time was of 35 min; dynamic extraction was performed with 15 mL of CO2, and it was used methanol (2 mL) for the dissolution of the final residue. In such conditions, pesticide recoveries varied from 72 to 94%, depending on the analyzed compound. In higher extraction temperatures, a rapid degradation was observed for some compounds, such as aldicarb and carbaryl; presence of their metabolites was further confirmed by HPLC-APCI/MS in positive mode. Detection limits for chromatographic analysis varied from 0,2 to 1,3 ng.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first paper in this series discussed the basic theory involved in supercritical fluid chromatography (SFC) and how the technique progressed from gas and liquid chromatography. The first SFC instruments were simple adaptations of the commercially available liquid chromatographs with packed columns followed by modifications in gas chromatographs using open tubular capillary columns. In this paper, the most important aspects regarding instrumentation are covered, including practical, simple, and the most important, inexpensive solutions to build a home-made SFC system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polysaccharide-based drilling fluids have been often applied in horizontal wells of petroleum reservoirs in Campos, Rio de Janeiro. The present study aimed to understand the mechanism of adsorption and desorption of the drill-in fluid, xanthan, modified starch and lubricant on SiO2 by means of ellipsometry. The effect of pH and brine on the mean thickness (D) of adsorbed layer was systematically investigated. The adsorption was mainly favored under alkaline conditions. A model has been proposed to explain this effect. The adsorption isotherms determined separately for xanthan and starch on SiO2 surfaces could be fitted with the Langmuir model, which yielded similar adsorption constant values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analytical method developed to evaluate tamoxifen in dog plasma samples was precise, accurate, robust and linear in the range of 5-200 ng/mL. The limits of detection and quantification were 0.981 ng/mL and 2.97 ng/mL, respectively. Besides, the intra-day precision and accuracy variations were 8.78 and 10.16%, respectively. Tamoxifen concentrations were analyzed by combined reversed phase liquid chromatography and UV detection (lambda=280 nm). The study was conducted using an open randomized 2-period crossover balanced design with a 1-week washout period between the doses. This simple, rapid and selective method is suitable for pharmacokinetic, bioavailability and bioequivalence studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to evaluate the antioxidant properties of ginger and rosemary extracts, obtained by supercritical extraction. The extracts were characterized by HPLC, GC-MS, phenolic compounds content and antioxidant activity. The main active compounds were identified and high content of phenolic compounds was observed. The extracts presented high antioxidant activity against the free radicals ABTS•+ (350 and 200 mM Trolox/g, for ginger and rosemary, respectively) and DPPH•+ (145 and 80 mM Trolox/g, for ginger and rosemary, respectively). These results suggested that the attained extracts are potential substitutes of synthetic antioxidants used in chemical, food and pharmaceutical industries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the construction of the phase diagrams, the method of the aqueous titration was used. There were prepared 5 ternary diagrams, varying the surfactant and the oil phase. The liquid-crystalline phases were identified by polarized light microscopy. The formulations prepared with silicon glycol copolymer, polyether functional siloxane (PFS) and water (S1) and with diisopropyl adipate, PFS and water (S4) presented liquid-crystalline phases with lamellar arrangement. Moreover, after 15 days in hot oven (37 ºC), the formulations presented hexagonal arrangement, evidencing the influence of the temperature in the organization of the system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reversed-phase liquid chromatographic (LC) and ultraviolet (UV) spectrophotometric methods were developed and validated for the assay of bromopride in oral and injectable solutions. The methods were validated according to ICH guideline. Both methods were linear in the range between 5-25 μg mL-1 (y = 41837x - 5103.4, r = 0.9996 and y = 0.0284x - 0.0351, r = 1, respectively). The statistical analysis showed no significant difference between the results obtained by the two methods. The proposed methods were found to be simple, rapid, precise, accurate, and sensitive. The LC and UV methods can be used in the routine quantitative analysis of bromopride in oral and injectable solutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alginate microparticles were prepared by an emulsion method aiming oral controlled release of antigens to fish. The effects of emulsification temperature and impeller type on particle morphology, average diameter, and size distribution were evaluated. Microparticles contaning formalin-killed Flavobacterium columnare cells (a model antigen) were prepared and characterized regarding bacterial release and particle stability when exposed to Nile tilapia (Oreochromis niloticus) typical gastrointestinal conditions. This methodology allowed the production of microparticles containing up to 14.3 g/L of bacterin, stable at a pH range from 2.0 to 9.0 for 12 h and smaller than 35 μm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fluid conducting composite material prepared from graphite powder, commercial epoxy resin Araldite®, and cyclohexanone has been developed. The composition was optimized considering the mechanical properties as conductivity and adhesiveness using response surface methodology. This work employed cyclic voltammetry and amperometry to investigate the characteristics of such composite electrodes without and with the insertion of Prussian blue in the electrode body (bulk modified electrode). The composite electrodes were also successfully used for the amperometric detection of hydrogen peroxide at 0.0V vs Ag/AgCl.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method using liquid chromatography has been developed and validated for determination of buclizine in pharmaceutical formulations and in release studies. Isocratic chromatography was performed on a C18 column with methanol:water (80:20 v/v, pH 2.6) as mobile phase, at a flow rate of 1.0 mL/min, and UV detection at 230 nm. The method was linear, accurate, precise, sensible and robust. The dissolution test was optimized and validated in terms of dissolution medium, apparatus agitation and rotation speed. The presented analytical and dissolution procedures can be conveniently adopted in the quality and stability control of buclizine in tablets and oral suspension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sulfasalazine is a prodrug used in the treatment of the Chron's disease and rheumatoid arthritis. Two analytical methods for analysis of sulfasalazine in oral suspension were validated using Spectrophotometric and HPLC. There is not any pharmacopoeic method to assay sulfasalazine in oral suspension. The methods are insurance and fast execution for the quality control. Both, suspension and tablets 500 mg (Azulfin®) had been analyzed by methods using UV/VIS and HPLC and the results were satisfactory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A selective and accurate stability-indicating gradient reverse phase ultra performance liquid chromatographic method has been developed and validated for the simultaneous determination of nizatidine, methylparaben and propylparaben in pharmaceutical oral liquid formulation. The separation was achieved on Acquity UPLC TM HSS T3 1.8 µm column by using mobile phase containing a gradient mixture of solvent A (0.02 Mol L-1 KH2PO4, pH 7.5) and B (60:40 v/v mixture of methanol and acetonitrile) at flow rate of 0.4 mL min-1. Drug product was exposed to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. The developed method was validated as per international ICH guidelines with respect to specificity, linearity, accuracy, precision and robustness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Serological techniques are of great importance for plant virus identification and characterization. The major limiting factor for using these techniques for plant virus identification is the requirement of a good virus purified preparation to be used in immunizing animals for antiserum production. In the present study, two New Zealand rabbits were orally immunized with extracts from cowpea (Vigna unguiculata) plants systemically infected with Cowpea severe mosaic virus (CPSMV) and with extracts from papaya (Carica papaya) infected with Papaya lethal yellowing virus (PLYV). The leaf extracts were prepared in saline solution 0.15 M in the rate of 1:1 (w/v) and clarified by a centrifugation of 10,000 g for 10 min. The clarified extracts containing the viruses were orally administered to the New Zealand rabbits in two series of five daily doses of 1.0 ml each. The obtained policlonal antisera were shown to be very specific to their respective viruses in double immunodiffusion and indirect ELISA. These seem to be the first antisera specific for plant virus obtained by rabbit oral immunization. The results open up some possibilities for producing antisera to plant viruses of difficult purification. It is a simple, fast and inexpensive method for production of antisera for plant viruses when compared to the traditional techniques that involve rabbit injections with purified virus preparations.