229 resultados para Progeny test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Proctor test is time-consuming and requires sampling of several kilograms of soil. Proctor test parameters were predicted in Mollisols, Entisols and Vertisols of the Pampean region of Argentina under different management systems. They were estimated from a minimum number of readily available soil properties (soil texture, total organic C) and management (training data set; n = 73). The results were used to generate a soil compaction susceptibility model, which was subsequently validated using a second group of independent data (test data set; n = 24). Soil maximum bulk density was estimated as follows: Maximum bulk density (Mg m-3) = 1.4756 - 0.00599 total organic C (g kg-1) + 0.0000275 sand (g kg-1) + 0.0539 management. Management was equal to 0 for uncropped and untilled soils and 1 for conventionally tilled soils. The established models predicted the Proctor test parameters reasonably well, based on readily available soil properties. Tillage systems induced changes in the maximum bulk density regardless of total organic matter content or soil texture. The lower maximum apparent bulk density values under no-tillage require a revision of the relative compaction thresholds for different no-tillage crops.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To express the negative effects of soil compaction, some researchers use critical values for soil mechanical strength that severely impair plant growth. The aim of this study was to identify this critical compaction depth, to test the functionality of a new, portable penetrometer developed from a spring dynamometer, and compare it to an electronic penetrometer traditionally used in compaction studies of agricultural soils. Three soils with distinct texture were conventionally tilled using a disk plow, and cultivated with different plant species. The critical soil resistance defined to establish critical compaction depth was equal to 1.5 MPa. The results of the new equipment were similar to the electronic penetrometer, indicating its viability as a tool for assessing the soil physical conditions for plant growth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this work were to estimate the genetic and phenotypic parameters and to predict the genetic and genotypic values of the selection candidates obtained from intraspecific crosses in Panicum maximum as well as the performance of the hybrid progeny of the existing and projected crosses. Seventy-nine intraspecific hybrids obtained from artificial crosses among five apomictic and three sexual autotetraploid individuals were evaluated in a clonal test with two replications and ten plants per plot. Green matter yield, total and leaf dry matter yields and leaf percentage were evaluated in five cuts per year during three years. Genetic parameters were estimated and breeding and genotypic values were predicted using the restricted maximum likelihood/best linear unbiased prediction procedure (REML/BLUP). The dominant genetic variance was estimated by adjusting the effect of full-sib families. Low magnitude individual narrow sense heritabilities (0.02-0.05), individual broad sense heritabilities (0.14-0.20) and repeatability measured on an individual basis (0.15-0.21) were obtained. Dominance effects for all evaluated characteristics indicated that breeding strategies that explore heterosis must be adopted. Less than 5% increase in the parameter repeatability was obtained for a three-year evaluation period and may be the criterion to determine the maximum number of years of evaluation to be adopted, without compromising gain per cycle of selection. The identification of hybrid candidates for future cultivars and of those that can be incorporated into the breeding program was based on the genotypic and breeding values, respectively. The prediction of the performance of the hybrid progeny, based on the breeding values of the progenitors, permitted the identification of the best crosses and indicated the best parents to use in crosses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to distinguish the parental source of alleles in heterozygous progeny using semiquantitative polymerase chain reaction (PCR) in maize endosperm. Endosperms derived from direct and reciprocal single-cross hybrids between maize inbred lines L3 and L1113-01 were genotyped by semiquantitative PCR methodology (SQ-PCR) using fluorescent microsatellite primers. The amplification products were evaluated by the ratios of fluorescence intensity (RFI), calculated between the peaks corresponding to the alleles derived from each parental line. Based on the statistically significant contrast between RFI mean values of direct and reciprocal single-cross hybrids, it was possible to distinguish the number of alleles received from each parental line and, ultimately, to determine the origin of the alleles of each cross. Thus, endosperm genotyping using SQ-PCR is a promising strategy to map QTL in maize outbred populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to evaluate the use of the conductivity test as a means of predicting seed viability in seven Passiflora species: P. alata, P. cincinnata, P. edulis f. edulis, P. edulis f. flavicarpa, P. morifolia, P. mucronata, and P. nitida. Conductivity of non-desiccated (control), desiccated, and non-desiccated cryopreserved seeds was determined and related to their germination percentage. The obtained results suggest that the electrical conductivity test has potential as a germination predictor for P. edulis f. flavicarpa seed lots, but not for the other tested species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A avaliação do processamento radiográfico utilizando o "STEP test" ("sensitometric test for the evaluation of processing") tem como objetivo a identificação de desvios importantes no sistema processadora-químicos-filmes. Neste tipo de avaliação são estabelecidas as condições ideais para o processamento. Um filme padrão é revelado de acordo com as condições do fabricante, ou seja, com padrão igual a 100. O filme é exposto à luz de um sensitômetro calibrado e os valores dos degraus são avaliados com o uso de um densitômetro, sendo obtida sua curva característica (densidade óptica × degrau). O desvio porcentual máximo deve ser de 20% quando comparado com a curva padrão. Este método é útil na identificação de problemas no processamento radiográfico. Várias processadoras de hospitais públicos/universitários foram avaliadas empregando este método, e verificou-se que aproximadamente 33% das instalações apresentam condições inadequadas de processamento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The present study was aimed at evaluating the viability of replacing 18F with 99mTc in dose calibrator linearity testing. Materials and Methods: The test was performed with sources of 99mTc (62 GBq) and 18F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical 99mTc and 18F sources activities were calculated and subsequently compared. Results: Mean deviations between experimental and theoretical 99mTc and 18F sources activities were 0.56 (± 1.79)% and 0.92 (± 1.19)%, respectively. The mean ratio between activities indicated by the device for the 99mTc source as measured with the equipment pre-calibrated to measure 99mTc and 18F was 3.42 (± 0.06), and for the 18F source this ratio was 3.39 (± 0.05), values considered constant over the measurement time. Conclusion: The results of the linearity test using 99mTc were compatible with those obtained with the 18F source, indicating the viability of utilizing both radioisotopes in dose calibrator linearity testing. Such information in association with the high potential of radiation exposure and costs involved in 18F acquisition suggest 99mTc as the element of choice to perform dose calibrator linearity tests in centers that use 18F, without any detriment to the procedure as well as to the quality of the nuclear medicine service.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The void structure of zeolites MCM-22, MCM-36 and ITQ-2 were discussed on the bases of catalytic reaction tests. The hydromerization of n-decane on bifunctional Pt/Zeolite Catalysts have been used as model reactions. Beta and ZSM-5 zeolites were used for comparison. It is concluded that all materials show features of 10MR zeolites and have also pores bigger than 12MR in this order MCM-22

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work is to develop and validate a dissolution test for glibenclamide tablets. Optimal conditions to carry out the dissolution test are 500 mL of phosphate buffer at pH 8.0, paddles at 75 rpm stirring speed, time test set to 60 min and using equipment with six vessels. The derivative UV spectrophotometric method for determination of glibenclamide released was developed, validated and compared with the HPLC method. The UVDS method presents linearity (r² = 0.9999) in the concentration range of 5-14 µg/mL. Precision and recoveries were 0.42% and 100.25%, respectively. The method was applied to three products commercially available on the Brazilian market.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we describe both a chromatographic purification procedure and a spot test for the enzyme peroxidase (POD: EC 1.11.1.7). The enzyme was obtained from crude extracts of sweet potatoes and the chromatographic enzyme purification procedure resulted in several fractions. Therefore a simple, fast and economic spot test for monitoring peroxidase during the purification procedure was developed. The spot test is based on the reaction of hydrogen peroxide and guaiacol, which is catalyzed by the presence of peroxidase yielding the colored tetraguaiacol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dissolution test for telithromycin tablets was validated and developed. In order to choose the most discriminatory one, the conditions to carry out are 900 mL of sodium phosphate buffer at pH 7.5, paddles at 50 rpm stirring speed, time test set to 60 min and using USP apparatus 2 with paddles. The UV spectrophotometric method for determination of telithromycin released was developed and validated. The method presents linearity (r = 1) in the concentration range of 20-60 µg/mL. Precision and recoveries were good, 100.62 and 97.06%, respectively. The method was successfully used for the dissolution test of telithromycin tablets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the development and validation of a dissolution test for 50 mg losartan potassium capsules using HPLC and UV spectrophotometry. A 2(4) full factorial design was carried out to optimize dissolution conditions and potassium phosphate buffer, pH 6.8 as dissolution medium, basket as apparatus at the stirring speed of 50 rpm and time of 30 min were considered adequate. Both dissolution procedure and analytical methods were validated and a statistical analysis showed that there are no significant differences between HPLC and spectrophotometry. Since there is no official monograph, this dissolution test could be applied for quality control routine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aimed the development and validation of a new dissolution test for ornidazole coated tablets. The dissolution conditions were determined after testing Sink conditions, dissolution medium, apparatus, stirring speed, 24 h stability and medium filtration influence. The best conditions were paddle at a stirring speed of 75 rpm and 900 mL of 0.1 M HCl. A new HPLC quantification method was developed and validated. The dissolution test and quantification method showed to be adequate for their purposes and could be applied for quality control of ornidazole coated tablets, since there is no official monograph.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dissolution test for in vitro evaluation of tablet dosage forms containing 10 mg of rupatadine was developed and validated by RP-LC. A discriminatory dissolution method was established using apparatus paddle at a stirring rate of 50 rpm with 900 mL of deaerated 0.01 M hydrochloric acid. The proposed method was validated yielding acceptable results for the parameters evaluated, and was applied for the quality control analysis of rupatadine tablets, and to evaluate the formulation during an accelerated stability study. Moreover, quantitative analyses were also performed, to compare the applicability of the RP-LC and the LC-MS/MS methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple liquid chromatographic method was optimized for the quantitative determination of terbinafine in pharmaceutical hydroalcoholic solutions and tablets, and was also employed for a tablet dissolution test. The analysis was carried out using a RP-C18 (250 mm × 4.6 mm, 5 μm) Vertical® column, UV-Vis detection at 254 nm, and a methanol-water (95:5, v/v) mobile phase at a flow-rate of 1.2 mL min-1. Method validation investigated parameters such as linearity, precision, accuracy, robustness and specificity, which gave results within the acceptable range. The tablets dissolution was quite fast: 80% of the drug was dissolved within 15 min.