426 resultados para Amostras
Resumo:
The sulphur take an essential role in plants and it is one of the main nutrients in several metabolic processes. The dry ash oxidation, using alkaline oxidizers agent, is the simplest and most economical form for the oxidation of Organic S to sulfate in plants. The objective of this work is to propose a method for sulfur determination in plants samples using dry ash oxidation and agent oxidizers alkaline. The quantification of S-SO4(2-) in samples was accomplished by turbidimetric method. The results demonstrated that the proposed method for oxidation alkaline was appropriate.
Resumo:
The influence of temperature, storage time and the addition of hydrochloride L-cysteine in the preservation of the fungicide mancozeb was studied under field conditions in the surface layer of a Cambisol collected in an area planted with cabbage in Nova Friburgo - RJ, Brazil. The results of this study showed an efficiency of up to 42% in the preservation of the fungicide in the samples treated with cysteine and stored at low temperatures compared to those not treated and kept at room temperature
Resumo:
A method based on enzymatic activities was developed using three enzymes (glycerokinase, glycerol-3-phosphate oxidase and peroxidase) and colorimetric detection for the determination of glycerol in biodiesel. The enzymatic conversion of glycerol produces H2O2 that is eliminated by the action of peroxidase, an oxygen acceptor and 4- aminoantipirine, producing water and a colored compound, which was analyzed. This method showed good linear correlation coefficient (r = 0.9937) in the concentration range of 4.95 x 10-5 to 3.96 x 10-4% (w/w) and had experimental limits of detection and quantitation of 7.10 x 10-6 and 2.10 x 10-5% (w/w), respectively.
Resumo:
Three samples of hydrotalcite-like materials (HTC) were synthesized and their structural characteristics were compared with two HTCs obtained commercially. Thermal analyses, FT-IR, PXRD and textural analyses were used to investigate the structural differences between commercial and synthetic samples. Particularly, the memory effect was observed at temperature higher than 600 ºC. The Rietveld refinements were obtained with expressive accuracy and the statistical parameters of goodness of fit are quite satisfactory. In conclusion, the procedures adopted in synthesis of HTC produced crystalline materials with high surface area materials.
Resumo:
In this work, the materials used in the recovery of estrogens from aqueous matrices by filtration and solid phase extraction were evaluated. The results showed that glass-fiber filters allow a recovery and repeatability compatible with this type of analysis, whereas cellulose esters lead to significant losses of the analytes, mainly due to adsorption processes. On the other hand, the transferring of the sample to the extraction cartridges should be carried out with glass or Teflon tubing, since the adsorption observed with other polymeric materials (eg. silicone, Tygon, polyethylene and PVC) dramatically reduces the recovery and repeatability of the extraction process.
Resumo:
In this paper studies based on Multilayer Perception Artificial Neural Network and Least Square Support Vector Machine (LS-SVM) techniques are applied to determine of the concentration of Soil Organic Matter (SOM). Performances of the techniques are compared. SOM concentrations and spectral data from Mid-Infrared are used as input parameters for both techniques. Multivariate regressions were performed for a set of 1117 spectra of soil samples, with concentrations ranging from 2 to 400 g kg-1. The LS-SVM resulted in a Root Mean Square Error of Prediction of 3.26 g kg-1 that is comparable to the deviation of the Walkley-Black method (2.80 g kg-1).
Resumo:
A sequential extraction procedure was applied to wheat and soybean seed samples. The total protein content (determined by two distinct methods: Bradford and bicinchoninic acid-BCA) and distribution of Cu, Fe, Mn and Zn in each fraction was determined. The sequential extraction employed four different solutions: water, 0.5 mol L-1 NaCl, ethanol/water (70:30 v v-1) and 0.5 mol L-1 NaOH. For both samples, the highest concentration of metals was observed in those extracts associated with globulin-type proteins using NaCl solution. Regarding protein content, higher levels were obtained using the BCA method.
Resumo:
The convenience of the multivariate optimization of SPME procedures through ANOVA calculated using Doehlert designs has been demonstrated for twelve PCBs in the complex matrix of milk. For this study, the main parameters of the extraction were selected and valued through univariate and multivariate optimization. In addition, the analysis of variance allowed identification of the statistically significant variables in this model: high temperature (95 ºC) and ionic strength (36% m/v) proved significant for all the PCBs while intermediate time (70 min) and low methanol concentration (5% v/v) also contributed to the extraction of the majority of these PCBs.
Resumo:
In this study, a method for determination of hexavalent chromium in aqueous samples using liquid-liquid microextraction (LLME) and detection by Flame Atomic Absorption Spectrometry (F AAS) was developed. The LLME procedure was based on the extraction of Cr (VI) by acetone at a sample pH of 1.2. The use of saturated ammonium sulphate solution allowed effective separation of the aqueous and organic phases and acetone extracted chromium. The sample pH, acetone volume and stirring time were optimized by a full factorial design.
Resumo:
Extraction/concentration is a crucial step for the analysis of organic compounds at trace level concentrations and dispersed in complex matrices. Solid-phase extraction (SPE) is one of the techniques used for this purpose. In this work, a low cost apparatus for SPE was developed that uses nitrogen under positive pressure and ensures the maintenance of the sample flow, while also allows the simultaneous extraction of different samples without cross-contamination and sample contact with plastic materials. For the system set up, easily accessible materials were used such as hypodermic needles, stainless steel tubes, rubber stoppers, and 3-way valves from serum delivery apparatus.
Resumo:
Ultraviolet radiation corresponds to a fraction of electromagnetic radiation, covering wavelengths between 1 and 400 nm. Methods based on UV irradiation have become popular because it is possible to treat samples simply by applying energy, avoiding procedures that require the use of toxic substances, thus contributing to the development of Green Chemistry. This study aimed to assess the main applications of UV radiation reported in the literature and thoroughly described the construction of an alternative and low-cost photochemical reactor to be used for the pretreatment of samples in the laboratory. The use of this new photochemical reactor in the clean-up of milk samples for spectrofluorimetric measurements was also reported.
Resumo:
Samples of whole fluid pasteurized, UHT and powdered milk were analyzed for the presence of organophosphorus pesticide residues (OPR) using the QuEChERS method with detection by GC-FPD and confirmation by UPLC-MS/MS. A total of 23% of fluid milk samples and 27% of powdered milk samples contained at least one organophosphorus residue. The OPR found in the samples showed these can reach the milk and remain even after pasteurization, sterilization and drying processes. Some domestic sanitary residues were also present in the powdered milk samples. These residues have no LMR in Brazilian food legislation and are therefore not taken into account in food intake evaluations. There was an unidentified chromatographic peak in 30% of all the liquid and powdered milk samples, indicating the presence of some other contaminant.
Resumo:
This paper describes the evaluation of a method for determination of Cd and Pb in xanthan gum samples by Graphite Furnace Atomic Absorption Spectrometry (GF AAS) using NH4H2PO4 as the chemical modifier. The sample preparation was performed using a reflux system adapted in the digestion tubes. With this system it was possible to increase the temperature of the digester block above the boiling point of the reaction medium, preventing loss of analyte and excessive evaporation of acids during heating. Samples were digested with HNO3 for 3 h in a digester block at 220 ºC. The limits of detection for Cd and Pb were 2.2 and 33.8 ng g-1, respectively. The RSDs for both analytes were, on average, lower than 5.0% and accuracy was verified by recovery tests, yielding values in the 83-100% range.
Resumo:
Knowing the mercury levels of an environment allows a diverse array of biogeochemical studies into the mercury cycle on a local or global scale. Among matrices commonly evaluated, water remains a challenge for research because its mercury levels can be very low, requiring development of complex analytical protocols. Currently, sample preservation methods, protocols that avoid contamination, and analytical techniques with low detection limits allow analysis of mercury in pristine waters. However, different protocols suggest different methods depending on a range of factors such as the characteristics of water sampled and storage time. In remote areas, such as oceanic and Amazonian regions, sample preservation and transport to a laboratory can be difficult, requiring processing of the water during the sampling expedition and the establishment of a field laboratory. Brazilian research on mercury in water can be limited due to difficulty obtaining reagents, lack of laboratory structure, qualified personnel, and financial support. Considering this complexity for analyzing water, we reviewed methodologies for sampling, preservation, and storage of water samples for analysis of the most commonly evaluated mercury species (dissolved gaseous mercury, reactive mercury, methylmercury and total mercury).