253 resultados para Aço de alta resistencia - Springback


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synthetic dyes were determined by high performance liquid chromatography in 76 samples of regular jelly and diet jelly powders, of several flavors produced by seven different manufacturers. Three sample of each product, from different batches, were analyzed. The same qualitative composition was observed for products of the same flavor from different manufacturers, but the quantitative composition varied markedly from one manufacturer to the other. There were no or few significant differences between batches from a given manufacturer, demonstrating good quality control in the use of these additives by the food industry. None of the samples exceeded the limit stipulated by Brazilian legislation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative GC-FID was evaluated for analysis of methylated copaiba oils, using trans-(-)-caryophyllene or methyl copalate as external standards. Analytical curves showed good linearity and reproducibility in terms of correlation coefficients (0.9992 and 0.996, respectively) and relative standard deviation (< 3%). Quantification of sesquiterpenes and diterpenic acids were performed with each standard, separately. When compared with the integrator response normalization, the standardization was statistically similar for the case of methyl copalate, but the response of trans-(-)-caryophyllene was statistically (P < 0.05) different. This method showed to be suitable for classification and quality control of commercial samples of the oils.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work reviews recent advances in the preparation of new reversed phase packing materials such as sterically protected, bidentate, hybrid organic-inorganic and monolithic phases and phases containing embedded polar groups. The bonding chemistry involved in the preparation of these phases as well as their advantages over conventional C8 and C18 reversed phases are discussed. Understanding the reasons behind the development of these newer column packings helps analysts select the best stationary phase for a given application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The violence derived from crimes involving firearms represents one of the main concerns of society. For this reason modern techniques have emerged in forensic science to identify suspects at crime scenes. This work describes a methodology to identify residues present in the hands of suspect by using a high resolution inductively coupled plasma mass spectrometry and collection procedure based on ethylenediaminetetraacetic acid (EDTA) solution as a complexing agent in moistened swabs. In order to distinguish real gunshot residues from others types of residues present in the hand of suspect, ternary ratio per cent diagrams were developed for antimony (Sb), barium (Ba) and lead (Pb) detected on the hands of volunteers, before and immediately after shooting tests, revealing a remarkable difference in both situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fuel cells are attracting much interest as efficient and clean energy conversion devices. The main components of low temperature fuel cells are the electrocatalysts used to promote the anodic and cathodic reactions, which are based on platinum and platinum alloys. These electrocatalysts are normally prepared in the form of metal nanoparticles supported on a conductive material, usually high surface area carbon, to improve catalyst utilization and reduce cost. This work presents and comments some methods used presently to produce these electrocatalysts. The performances of the produced electrocatalysts are compared to that of state-of-the-art commercial E-TEK electrocatalysts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The demand for analytical methods suitable for accurate and reproducible determination of drug enantiomers has increased significantly in the last years. High-performance liquid chromatography (HPLC) using chiral stationary phases and capillary electrophoresis (CE) are the most important techniques used for this purpose. In this paper, the fundamental aspects of chiral separations using both techniques are presented. Some important aspects for the development of enantioselective methods, particularly for the analysis of drugs and metabolites in biological samples, are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new solid phase microextraction (SPME) system, known as in-tube SPME, was recently developed using an open tubular fused-silica capilary column, instead of an SPME fiber, as the SPME device. On-line in-tube SPME is usually used in combination with high performance liquid chromatography. Drugs in biological samples are directly extracted and concentrated in the stationary phase of capillary columns by repeated draw/eject cycles of sample solution, and then directly transferred to the liquid chromatographic column. In-tube SPME is suitable for automation. Automated sample handling procedures not only shorten the total analysis time, but also usually provide better accuracy and precision relative to manual techniques. In-tube SPME has been demonstrated to be a very effective and highly sensitive technique to determine drugs in biological samples for various purposes such as therapeutic drug monitoring, clinical toxicology, bioavailability and pharmacokinetics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A high performance liquid chromatography method was developed to quantify lamivudine, stavudine and nevirapine combined in tablets. The separation was carried out in less than 10 min using a phosphate buffer of pH 3.0 and acetonitrile (75:25, v/v) as mobile phase, a LiChrospher ODS column and UV detection at 266 nm. The method was linear over the range of 15-135 µg/mL (lamivudine), 4-36 µg/mL (stavudine) and 20-180 µg/mL (nevirapine). The accuracy ranged from 98.56 to 102.04% and intra-day and inter-day precision was less than 1% for the three drugs. The method showed robustness, remaining unaffected by deliberate variations in relevant parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reverse phase liquid chromatography method was developed for simultaneous determination of trigonelline, caffeine, nicotinic and chlorogenic (5-CQA) acids in roasted coffee. A gradient of acetic acid/acetonitrile was used as mobile phase and detection was carried out in the UV. The samples were extracted with acetonitrile/water (5:95 v/v) at 80 ºC/10 min. Good recovery (89 to 104%), repeatability and linearity were obtained. Detection limits of 0.01, 0.15, 0.04 and 0.04 mg mL-1 were observed for nicotinic acid, trigonelline, 5-CQA and caffeine. The method, applied to arabica and robusta coffees with different degrees of roasting, was efficient and fast (~35 min) and also allowed identification of cinnamic acids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes the use of a conventional CRT monitor as a high voltage power supply for capillary electrophoresis. With this monitor, a 23-kV high voltage with a ripple of 1.32% was observed. The reproducibility of the applied high voltage was evaluated by measuring the standard deviations of peak area and migration time for five consecutive injections of a test mixture containing potassium, sodium, and lithium cations at 50 mmol L-1. The errors were about 2.5% and 0.6% for peak area and migration time, respectively. The maximum current tested was about 180 mA, which covers most capillary electrophoresis applications. This system has been successfully used for several months, maintaining the desired level of performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid and efficient method for the analysis of histamine in wines using HPLC with fluorescence detection after derivatization was developed and validated. The method LOD and LOQ values were 0.25 and 0.50 mg L-1 respectively. The repeatability and intermediary precision for the instrument and for the method presented RSD values of 3.7 and 2.9%, and 6.0 and 5.6%, respectively. The recoveries were 95.5 and 89.9% for the fortification levels of 2 and 10 mg L-1. The method was applied to determine the histamine content in Cabernet Sauvignon wines, which presented values between 1.2 and 5.7 mg L-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for HPLC determination of sulfadimethoxyne in milk is presented. The analyte isolation and concentration were performed by solid-phase extraction through a C-8 cartridge, pre-conditioned with hexane, methanol and water and eluted with MeOH. The recovery determination was done with a spiked solution of 20, 50 or 100 µg L-1. In this concentration range, the recovery was 83.2% with a RDS of 15.4%. For quantification, a Zorbax Eclipse XDB-C8 (4.6 mm x 150 mm, 5 µm), a mobile phase of MeCN: 0.01 mol L-1 KH2PO4 aq. (1:4), and a variable wavelength detector (275 nm) were used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synthetic dyes are much used in processed foods. HPLC was applied to different types of snacks, such as colored cereals, chocolate confetti, chewing gums and candies for the determination of those additives. In the case of artificially colored breakfast cereals, 71% of the samples exceeded the allowed limits. Regarding the portions recommended for consumption by the makers of two of the samples, the amounts exceeded those allowed by the Brazilian legislation. In the case of chocolate confetti and candies none of the samples showed higher amounts than those allowed. However 37% of the chewing gum samples presented larger contents than the authorized ones, and one sample contained five times more synthetic dyes than allowed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paclobutrazol is a plant growth retardant which is used world-wide for increasing the yield of cereal crops. However, this compound remains active in the soil for several years and can severely affect the growth and development of subsequent crops, mainly by reducing vegetative vigor. The aim of this work was to develop and validate methods for the determination of paclobutrazol concentrations by both high performance liquid chromatography and spectroscopy. Both methods were satisfactory and showed appropriately low quantification limits. The determination by spectroscopy has, however, the advantage of being a method significantly less expensive than high performance liquid chromatography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An HPLC method was validated to assay lamivudine and zidovudine combined in tablets. The chromatographic separation was carried out using methanol and acetate buffer pH 6.5 (50:50 v/v) and a RP-18 column, as mobile and stationary phase, respectively. The UV detection was at 270 nm. The method was linear in the range of 24 - 36 µg/mL (lamivudine) and 48 - 72 µg/mL (zidovudine). The recovery (accuracy) ranged from 101.35% to 103.04% and the precision (repeatability and intermediate precision) was less than 2%. The method can be also applied to the quantification of these drugs in the dissolution test of tablets containing both drugs.