129 resultados para fluorescence probe technique


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel Fe3+-selective and turn-on fluorescent probe 1 incorporating a rhodamine fluorophore and quinoline subunit was synthesized. Probe 1 displayed high selectivity for Fe3+ in CH3CN–H2O (95:5 v/v) in the presence of other relevant metal cations. Interaction with Fe3+ in 1:1 stoichiometry could trigger a significant fluorescence enhancement due to the formation of the ring-open form. The fluorescent response images were investigated by a novel Euclidean distance method based on red, green, and blue values. A linear relationship was observed between fluorescence intensity changes and Fe3+ concentrations from 7.3 × 10−7 to 3.6 × 10−5 mol L−1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two series of alkanediyl-a,w-bis (dimethylalkylammonium bromide (n-2-n and n-6-n; n=8, 10,12, and 16) have been synthesized and their micelles properties studied in aqueous solution using pyrene, pyrenecarboxaldehyde (PCA) and 1,8 anilinonaphtalene sulfonic acid sodium salt (ANS) as fluorescent probes. The micelles from these surfactants have been characterized on the basis of the information provided by micelle-solubilized fluorescent probes. The obtained results indicated that the surfactant concentration at which a marked decrease in l max parameter of pyrenecarboxaldehyde (PCA) occurs corresponds to the CMC determined by conductimetric measurements. Changes in the emission spectra of ANS and PCA observed in the submicellar range for both surfactants series (n-2-n and n-6-n) were interpreted as formation of pre-aggregates. It was found that the dimeric surfactants with long spacer (s= 6) form more hydrated aggregates when compared with those formed by the n-2-n and CnTAB surfactants series. This was attributed to a more difficult packing of n-6-n surfactant molecules to form micelles.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The binding of chlorpromazine (CPZ) and hemin to bovine serum albumin was studied by the fluorescence quenching technique. CPZ is a widely used anti-psychotic drug that interacts with blood components, influences bioavailability, and affects function of several biomolecules. Hemin is an important ferric residue of hemoglobin that binds within the hydrophobic region of albumin with high specificity. Quenching of the intrinsic fluorescence of bovine serum albumin (BSA) was observed by selectively exciting tryptophan residues at 290 nm. Emission spectra were recorded in the range from 300 to 450 nm for each quencher addition. Stern-Volmer graphs were plotted, and the quenching constant estimated for BSA solution titrated with hemin at 25ºC was 1.44 (± 0.05) x 10(5) M-1. Results showed that bovine albumin tryptophans are not equally accessible to CPZ, in agreement with the idea that polar or charged quenchers have more affinity for amino acid residues on the outer wall of the protein. Hemin added to albumin solution at a molar ratio of 1:1 quenched about 25% of their fluorescence. The quenching effect of CPZ on albumin-hemin solution was stronger than on pure BSA. This increase can be the result of combined conformational changes in the structure of albumin caused firstly by hemin and then by CPZ. Our results suggest that the primary binding site for hemin on bovine albumin may be located asymmetrically between the two tryptophans along the sequence formed by subdomains IB and IIA, closer to tryptophan residue 212.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The occurrence of green seeded soybeans [Glycine max (L.) Merrill] is a problem closely related to unfavorable climatic conditions, mainly drought, that occurs during the final stages of seed maturation. This problem causes serious losses to soybean seed quality in Brazil. In these seeds, chlorophyll is not properly degraded during maturation, drastically reducing seed quality. Using the chlorophyll fluorescence technique, it is possible to remove green seeds from the seed lot, improving seed quality in several species in which the occurrence of green seeds is also a problem. The objective of this research was to study the use of the chlorophyll fluorescence technique in sorting green seeds from soybean seed samples and its effects on quality. Five seed samples of soybean, cultivar TMG 113 RR, with 0%, 5%, 10%, 15%, and 20% of green seeds were used in this study. Seeds from each sample were sorted into two fractions based on the chlorophyll fluorescence signals and then compared to the control (non-sorted seeds). The sorting process showed great differences between the low and high chlorophyll fluorescence fractions. It was concluded that: green seeds of soybeans present high chlorophyll fluorescence and that this characteristic affects the quality of the seeds; it is possible to improve the quality of soybean seed by removing green seeds using the chlorophyll fluorescence sorting technique.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Due to source contamination and wearing of instrument components problems caused by the direct insertion probe technique, a new way of introduction of low volatile compounds into mass spectrometer was tested. This new scheme comprises the introduction of the low volatile compounds solutions via a six port valve connected to a particle beam interface. Solutions of isatin were injected into this system and the best results were obtained with CH2Cl2, CH3OH and CH3CN. The solution inlet system has shown to be advantageous over the conventional way of direct insertion probe introduction.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Rare earth ion doped solid state materials are the most important active media of near-infrared and visible lasers and other photonic devices. In these ions, the occurrence of Excited State Absorptions (ESA), from long lived electronic levels, is commonplace. Since ESA can deeply affect the efficiencies of the rare earth emissions, evaluation of these transitions cross sections is of greatest importance in predicting the potential applications of a given material. In this paper a detailed description of the pump-probe technique for ESA measurements is presented, with a review of several examples of applications in Nd3+, Tm3+ and Er3+ doped materials.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Compulsory in Brazil, toy certification aims to prevent possible risks in toy use. The Brazilian National Institute of Metrology (INMETRO) establishes the maximum concentration of toxic elements (TE) that may be present in toys. This study evaluates the presence of TE in different crayons, gouache and modeling clays using X-ray fluorescence. This technique is fast, has low operating cost and minimum sample pretreatment, resulting in a clean procedure without reagent consumption and waste generation. Bromine (in gouache) and Barium (in crayons) were the only potentially TE identified in the samples studied.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The binding of [RuCl2(L)] (L = N,N-bis(7-methyl-2-pyridylmethylene)-1,3-diiminopropane) to bovine and human serum albumin was investigated by the fluorescence quenching technique. The comparison of the quenching effect of serum albumin fluorescence by ruthenium complex allowed the estimation of subdomain IB in BSA and subdomain IIA in HSA as the binding sites for this complex. The results of fluorescence titration revealed that ruthenium complex quenches the intrinsic fluorescence of BSA through a dynamic quenching mechanism, while HSA has a static quenching mechanism. The thermodynamic parameters indicated that hydrophobic forces played a major role in the binding of ruthenium complex to proteins. The process of binding was a spontaneous process in which Gibbs free energy change was negative.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A digoxigenin-labeled probe was produced from the Pasteur virus strain for the detection of the rabies virus N gene. The probe hybridization was performed from amplified N gene obtained by reverse transcription polymerase chain reaction and the results by RT-PCR and hybridization showed 100% agreement. The hybridization, when carried out in products amplified by RT-PCR, increases the sensitivity of this technique even more and confers specificity to the diagnosis. The technique described in this work will be useful in rabies diagnosis laboratories, once the cost is compatible with traditional rabies diagnostic techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Williams-Beuren syndrome is a rare multiple anomalies/mental retardation syndrome caused by deletion of contiguous genes at chromosome region 7q11.23. The aim of this work was to determine the frequency and the types of renal and urinary tract anomalies in 20 patients with Williams-Beuren syndrome. METHODS: The fluorescence in situ hybridization test using a LSI Williams syndrome region DNA probe was performed for all 20 patients to confirm the diagnosis of Williams-Beuren syndrome. A prospective study was performed in order to investigate renal and urinary aspects using laboratory assays to check renal function, ultrasonography of the kidneys and urinary tract, voiding cystourethrogram and urodynamics. RESULTS: Deletion of the elastin gene (positive fluorescence in situ hybridization test) was found in 17 out of 20 patients. Renal alterations were diagnosed in 5 of 17 (29%) the patients with the deletion and in 1 of 3 patients without the deletion. Fourteen patients with the deletion presented dysfunctional voiding. Arterial hypertension was diagnosed in 3 patients with deletions and 1 of these presented bilateral stenosis of the renal arteries. CONCLUSIONS: Due to the high incidence of renal and urinary abnormalities in Williams-Beuren syndrome, performing a systematic laboratory and sonographic evaluation of the patients is recommended.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Volumetric soil water content (theta) can be evaluated in the field by direct or indirect methods. Among the direct, the gravimetric method is regarded as highly reliable and thus often preferred. Its main disadvantages are that sampling and laboratory procedures are labor intensive, and that the method is destructive, which makes resampling of a same point impossible. Recently, the time domain reflectometry (TDR) technique has become a widely used indirect, non-destructive method to evaluate theta. In this study, evaluations of the apparent dielectric number of soils (epsilon) and samplings for the gravimetrical determination of the volumetric soil water content (thetaGrav) were carried out at four sites of a Xanthic Ferralsol in Manaus - Brazil. With the obtained epsilon values, theta was estimated using empirical equations (thetaTDR), and compared with thetaGrav derived from disturbed and undisturbed samples. The main objective of this study was the comparison of thetaTDR estimates of horizontally as well as vertically inserted probes with the thetaGrav values determined by disturbed and undisturbed samples. Results showed that thetaTDR estimates of vertically inserted probes and the average of horizontally measured layers were only slightly and insignificantly different. However, significant differences were found between the thetaTDR estimates of different equations and between disturbed and undisturbed samples in the thetaGrav determinations. The use of the theoretical Knight et al. model, which permits an evaluation of the soil volume assessed by TDR probes, is also discussed. It was concluded that the TDR technique, when properly calibrated, permits in situ, nondestructive measurements of q in Xanthic Ferralsols of similar accuracy as the gravimetric method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To evaluate the utility of a new multimodal image-guided intervention technique to detect epileptogenic areas with a gamma probe as compared with intraoperative electrocorticography. Materials and Methods Two symptomatic patients with refractory epilepsy underwent magnetic resonance imaging, videoelectroencephalography, brain SPECT scan, neuropsychological evaluation and were submitted to gamma probe-assisted surgery. Results In patient 1, maximum radioactive count was initially observed on the temporal gyrus at about 3.5 cm posteriorly to the tip of the left temporal lobe. After corticotomy, the gamma probe indicated maximum count at the head of the hippocampus, in agreement with the findings of intraoperative electrocorticography. In patient 2, maximum count was observed in the occipital region at the transition between the temporal and parietal lobes (right hemisphere). During the surgery, the area of epileptogenic activity mapped at electrocorticography was also delimited, demarcated, and compared with the gamma probe findings. After lesionectomy, new radioactive counts were performed both in the patients and on the surgical specimens (ex-vivo). Conclusion The comparison between intraoperative electrocorticography and gamma probe-assisted surgery showed similarity of both methods. The advantages of gamma probe include: noninvasiveness, low cost and capacity to demonstrate decrease in the radioactive activity at the site of excision after lesionectomy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Molecular probe techniques have made important contributions to the determination of microstructure of surfactant assemblies such as size, stability, micropolarity and conformation. Conductivity and surface tension were used to determine the critical aggregation concentration (cac) of polymer-surfactant complexes and the critical micellar concentration (cmc) of aqueous micellar aggregates. The results are compared with those of fluorescent techniques. Several surfactant systems were examined, 1-butanol-sodium dodecylsulfate (SDS) mixtures, solutions containing poly(ethylene oxide)-SDS, poly(vinylpyrrolidone)-SDS and poly(acrylic acid)-alkyltrimethylammonium bromide complexes. We found differences between the cac and cmc values obtained by conductivity or surface tension and those obtained by techniques which use hydrophobic probe.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Here we report the validation of a derivatization method that makes use of fluorescamine as a selective reactant for the quantitative analysis of peptide and protein drugs in the dissolution profile from depot formulations. Typical current methods require separation of the nano/microparticles and time-consuming chromatographic runs. In this study we report a method which can be conducted without the need for complete physical separation of the particles or removal of the unreacted probe. This method was used here for the analysis of the release profile of octreotide in a depot formulation, with results in excellent agreement with reported chromatographic assays.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It has been shown for several DNA probes that the recently introduced Fast-FISH (fluorescence in situ hybridization) technique is well suited for quantitative microscopy. For highly repetitive DNA probes the hybridization (renaturation) time and the number of subsequent washing steps were reduced considerably by omitting denaturing chemical agents (e.g., formamide). The appropriate hybridization temperature and time allow a clear discrimination between major and minor binding sites by quantitative fluorescence microscopy. The well-defined physical conditions for hybridization permit automatization of the procedure, e.g., by a programmable thermal cycler. Here, we present optimized conditions for a commercially available X-specific a-satellite probe. Highly fluorescent major binding sites were obtained for 74oC hybridization temperature and 60 min hybridization time. They were clearly discriminated from some low fluorescent minor binding sites on metaphase chromosomes as well as in interphase cell nuclei. On average, a total of 3.43 ± 1.59 binding sites were measured in metaphase spreads, and 2.69 ± 1.00 in interphase nuclei. Microwave activation for denaturation and hybridization was tested to accelerate the procedure. The slides with the target material and the hybridization buffer were placed in a standard microwave oven. After denaturation for 20 s at 900 W, hybridization was performed for 4 min at 90 W. The suitability of a microwave oven for Fast-FISH was confirmed by the application to a chromosome 1-specific a-satellite probe. In this case, denaturation was performed at 630 W for 60 s and hybridization at 90 W for 5 min. In all cases, the results were analyzed quantitatively and compared to the results obtained by Fast-FISH. The major binding sites were clearly discriminated by their brightness