93 resultados para HISTOPATHOLOGIC VALIDATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The increasing proportion of older adults in the general population and the specific characteristics of this age group show the need for the development of specific instruments to measure quality of life in older adults. The study aimed at describing the development and validation of the Portuguese version of the World Health Organization Quality of Life for Older Persons (WHOQOL-OLD) module. METHODS: The WHOQOL-OLD instrument was administered in a sample of 424 older adults in the city of Porto Alegre, Southern Brazil, in 2005. The questionnaire comprises 24 items divided into six facets: sensory abilities; autonomy; past, present and future activities; social participation; death and dying; and intimacy. Besides the WHOQOL-OLD module, the WHOQOL-BREF, BDI and BHS instruments were also applied. The instrument's internal consistency was assessed using Cronbach's alpha coefficient. RESULTS: The instrument showed adequate internal consistency (Cronbach's coefficients ranging from 0.71 to 0.88), discriminant validity (p<0.01), concurrent validity (correlation coefficients ranging from -0.61 to -0.50) and test-retest reliability (correlation coefficients ranging from 0.58 to 0.82). Findings concerning criterion validity need further studies. CONCLUSIONS: The WHOQOL-Old module is a useful alternative with good psychometric performance in the investigation of quality of life in older adults.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Translate the Patient-centered Assessment and Counseling for Exercise questionnaire, adapt it cross-culturally and identify the psychometric properties of the psychosocial scales for physical activity in young university students.METHODS The Patient-centered Assessment and Counseling for Exercise questionnaire is made up of 39 items divided into constructs based on the social cognitive theory and the transtheoretical model. The analyzed constructs were, as follows: behavior change strategy (15 items), decision-making process (10), self-efficacy (6), support from family (4), and support from friends (4). The validation procedures were conceptual, semantic, operational, and functional equivalences, in addition to the equivalence of the items and of measurements. The conceptual, of items and semantic equivalences were performed by a specialized committee. During measurement equivalence, the instrument was applied to 717 university students. Exploratory factor analysis was used to verify the loading of each item, explained variance and internal consistency of the constructs. Reproducibility was measured by means of intraclass correlation coefficient.RESULTS The two translations were equivalent and back-translation was similar to the original version, with few adaptations. The layout, presentation order of the constructs and items from the original version were kept in the same form as the original instrument. The sample size was adequate and was evaluated by the Kaiser-Meyer-Olkin test, with values between 0.72 and 0.91. The correlation matrix of the items presented r < 0.8 (p < 0.05). The factor loadings of the items from all the constructs were satisfactory (> 0.40), varying between 0.43 and 0.80, which explained between 45.4% and 59.0% of the variance. Internal consistency was satisfactory (α ≥ 0.70), with support from friends being 0.70 and 0.92 for self-efficacy. Most items (74.3%) presented values above 0.70 for the reproducibility test.CONCLUSIONS The validation process steps were considered satisfactory and adequate for applying to the population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT OBJECTIVE To validate an instrument designed to assess health promotion in the school environment. METHODS A questionnaire, based on guidelines from the World Health Organization and in line with the Brazilian school health context, was developed to validate the research instrument. There were 60 items in the instrument that included 40 questions for the school manager and 20 items with direct observations made by the interviewer. The items’ content validation was performed using the Delphi technique, with the instrument being applied in 53 schools from two medium-sized cities in the South region of Brazil. Reliability (Cronbach’s alpha and split-half) and validity (principal component analysis) analyses were performed. RESULTS The final instrument remained composed of 28 items, distributed into three dimensions: pedagogical, structural and relational. The resulting components showed good factorial loads (> 0.4) and acceptable reliability (> 0.6) for most items. The pedagogical dimension identifies educational activities regarding drugs and sexuality, violence and prejudice, auto care and peace and quality of life. The structural dimension is comprised of access, sanitary structure, and conservation and equipment. The relational dimension includes relationships within the school and with the community. CONCLUSIONS The proposed instrument presents satisfactory validity and reliability values, which include aspects relevant to promote health in schools. Its use allows the description of the health promotion conditions to which students from each educational institution are exposed. Because this instrument includes items directly observed by the investigator, it should only be used during periods when there are full and regular activities at the school in question.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Female albino rats were used for the sequential histopathological study of experimental paracoccidioidomycosis. The animals were inoculated intraperitoneally with a strain of Paracoccidioides brasiliensis in the yeast-like phase, and sacrificed at given intervals from 1 to 168 days after inoculation; each animal received an inoculum of 4 x 10(6) cells in 0.8 ml of saline. The control group received saline containing scrapings of the culture medium. Tissue from the inoculation site was examined. The cellular population, the extracellular matrix, and the presence and characteristics of fungi were analysed in the inflammatory granulomatous process by light microscopy. The results allowed to separate the kinetic of the inflammatory response into three stages: 1) neutrophilic or macrophagic-neutrophilic; 2) pre-granulomatous; 3) granulomatous. Synthesis of the extracellular matrix began with the depositing of fibrin-like material, and increased gradually with deposits of collagen, proteoglycans, and glycoproteins. Parasites were present in all of the examined periods. Recurrences of the disease were clearly shown through the concurrence of recently-formed granulomas with older granulomas, implying that this type of granulomatous process does not eliminate the disease, nor is it able to limit fungal dissemination over a prolonged period of time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of infection with Trypanosoma cruzi on the electrocardiographic tracings of mice were studied in 4.groups of animals: (1) normal; (2) infected with a pathogenic T. cruzi strain (TS COB); (3) immunized with 3 intraperitoneal inocula of 10(6) attenuated T. cruzi epimastigotes (TCC) and (4) immunized-infected, which sequentially received the treatments of groups 3 and 2. Infection and protection were confirmed by xenodiagnosis and histopathology. Isolated alterations such as extrasystolia, 1st degree atrioventricular block, arrhythmia and ST elevation were observed in normal as well as infected mice. However, tracings taken repeatedly on each mouse over a 293 day period revealed a set of alterations which were more frequently seen in infected (14/22) than in normal (4/27) animals (p = 0.00048). These alterations consisted of supraventricular tachycardia, sinus bradycardia and persisting, first degree AV blocks, often associated to pacemaker changes. Inoculation of attenuated T. cruzi (group 3) did not increase these alterations (2/27 mice) but significantly prevented their development after challenge with the pathogenic strain (1/19 versus 14/22 mice, p = 0.000095). Thus, preimmunization reduced not only parasitemia but also a pathogenic consequence of T. cruzi infection. This evidence is relevant for immunoprevention studies against Chagas' disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to validate the 14C-urea breath test for use in diagnosis of Helicobacter pylori infection. Thirty H. pylori positive patients, based on histologic test and thirty H. pylori negative patients by histology and anti-H. pylori IgG entered the study. Fasting patients drank 5 uCi of 14C-urea in 20 ml of water. Breath samples were collected at 0, 5, 10, 15, 20 and 30 min. The difference of cpm values between the two groups was significant at all the time intervals, besides time 0 (p<0.0001). At 20 min, the test gave 100% sensitivity and specificity with a cut-off value of 562 cpm. Females were higher expirers than males (p=0.005). 14C-urea breath test is highly accurate for Helicobacter pylori diagnosis. It is fast, simple and should be the non-invasive test used after treating Helicobacter pylori infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to validate the rapid lateral flow Helicobacter pylori stool antigen test (One step H. pylori antigen test, ACON laboratories, San Diego, USA; Prime diagnostics, São Paulo), using 13C-Urea Breath Test as the gold standard for H. pylori infection diagnosis. A total of 98 consecutive patients, asymptomatic or dyspeptic, entered the study. Sixty-nine were women, with a mean age of 45.76 ± 14.59 years (14 to 79 years). In the H. pylori-positive group, the rapid stool antigen test detected H. pylori antigen in 44 of the 50 positive patients (sensitivity 88%; 95% CI: 75.7-95.5%), and six false-negative; and in the H. pylori-negative group 42 presented negative results (specificity 87.5%; 95% CI: 74.7-95.3%), and six false-positive, showing a substantial agreement (Kappa Index = 0.75; p < 0.0001; 95% CI: 0.6-0.9). Forty four of fifty patients that had positive stool antigen were H. pylori-positive, the PPV of the stool antigen test was 88% (95% CI: 75.7-95.5%), and 42 patients with negative stool antigen test were H. pylori-negative, the NPV of the stool antigen test was 87.5% (95% CI: 74.7-95.3%). We conclude that the lateral flow stool antigen test can be used as an alternative to breath test for H. pylori infection diagnosis especially in developing countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Leptospirosis is often mistaken for other acute febrile illnesses because of its nonspecific presentation. Bacteriologic, serologic, and molecular methods have several limitations for early diagnosis: technical complexity, low availability, low sensitivity in early disease, or high cost. This study aimed to validate a case definition, based on simple clinical and laboratory tests, that is intended for bedside diagnosis of leptospirosis among hospitalized patients. METHODS: Adult patients, admitted to two reference hospitals in Recife, Brazil, with a febrile illness of less than 21 days and with a clinical suspicion of leptospirosis, were included to test a case definition comprising ten clinical and laboratory criteria. Leptospirosis was confirmed or excluded by a composite reference standard (microscopic agglutination test, ELISA, and blood culture). Test properties were determined for each cutoff number of the criteria from the case definition. RESULTS: Ninety seven patients were included; 75 had confirmed leptospirosis and 22 did not. Mean number of criteria from the case definition that were fulfilled was 7.8±1.2 for confirmed leptospirosis and 5.9±1.5 for non-leptospirosis patients (p<0.0001). Best sensitivity (85.3%) and specificity (68.2%) combination was found with a cutoff of 7 or more criteria, reaching positive and negative predictive values of 90.1% and 57.7%, respectively; accuracy was 81.4%. CONCLUSIONS: The case definition, for a cutoff of at least 7 criteria, reached average sensitivity and specificity, but with a high positive predictive value. Its simplicity and low cost make it useful for rapid bedside leptospirosis diagnosis in Brazilian hospitalized patients with acute severe febrile disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To review the medical literature regarding the histopathologic and biochemical liver test abnormalities in chronic asymptomatic or oligosymptomatic alcoholics. METHODS: Review of articles in the MEDLINE and LILACS databases regarding serum levels and prevalence of alterations in aspartate-aminotransferase, alanine-aminotransferase, alkaline phosphatase, and total bilirubin, in relation to liver histopathology, with or without discrimination of types of histopathologic alteration. RESULTS: Global mean prevalence rates of aspartate-aminotransferase and alanine-aminotransferase alterations were 86.3% and 51.1%; in cases with steatosis they were 79.1% and 38.5%; and in cases of hepatitis, 90.1% and 58%. In all studies, prevalence rates of aspartate-aminotransferase alterations were significantly higher with lower variability than those of alanine-aminotransferase. Mean aspartate-aminotransferase levels were higher than 2N (N is the upper normal limit of the method employed) in all cases with hepatitis histopathology, while those of alanine-aminotransferase were 1.48N, in the same cases. Prevalence of alkaline phosphatase and total bilirubin abnormalities were 74.5% and 74.9% globally; in cases of steatosis, they were 70.9% and 67.9%; and in cases of hepatitis, 75.9% and 77.7%. Mean alkaline phosphatase levels were above the upper normal limit in all cases, but those of total bilirubin were above normal in 4 of 7 hepatitis studies. CONCLUSIONS: Prevalence of aspartate-aminotransferase alteration was consistently related to presence of histopathologic abnormalities; an enzyme level higher than 2N suggests the diagnosis of alcoholic hepatitis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This work was designed to validate the Portuguese version of the Contemplation Ladder, whose purpose is to assess the motivational phase to quit smoking among tobacco users using a telephone service. METHOD: A cross-sectional study was conducted in a nationwide drug use information hotline. In order to assess the convergent validation, the correlation between the Contemplation Ladder and the URICA Scale was calculated, which was previously validated. RESULTS: The study included 271 tobacco users. Statistically significant correlations were found between the Contemplation Ladder scores and the scores of the URICA precontemplation (r=-0.16; p<0.01), action (r=0.15; p<0.01) and maintenance (r=0.18; p<0.01) subscales. The correlation between the URICA Scale compound score and the Contemplation Ladder was also significant (r=0.31; p<0.01). CONCLUSION: The results of our study suggest that the Contemplation Ladder can be an efficient substitute for the URICA scale (whose application lasts at least 20 minutes), without submitting the interviewee to a heavy load of questions. The study presented evidences of convergent validity for the Contemplation Ladder when applied via telephone in tobacco users.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT Objective To perform the psychometric evaluation of the Disordered Eating Attitude Scale (DEAS) for adolescents. Methods Sample consisted of 1,119 Brazilian adolescents (12-18 years old; 59.6% female) studying at technical schools in São Paulo state-Brazil, who answered an online survey with the DEAS, the Eating Attitude Test (EAT-26), and the Restraint Scale (RS). The internal consistency of the DEAS was assessed using Cronbach’s alpha. The convergent validity of DEAS was evaluated by means of Pearson’s coefficient correlation with EAT-26 and RS. The test-retest reliability was evaluated using a sub-sample of 61 adolescents. Known-groups validity was determined by comparing female student mean scores with scores of 33 female adolescents with eating disorders. Results The reliability of the DEAS was 0.79. EAT-26 and RS scores were positively correlated with DEAS scores (EAT: 0.78 for females and 0.59 for males, p < 0.001; RS: 0.63 for females and 0.48 for males, p < 0.001). The DEAS total and subscale scores differentiated students and patients with eating disorders (p < 0.001). The intra-class correlation coefficient for test-retest reliability was 0.87. Conclusion Results indicate that the DEAS adolescent version showed good internal consistency, convergent validity, known-groups validity, and test-retest reliability, suggesting its potential in identifying disordered eating attitudes among adolescents. It could also be helpful in identifying adolescents at risk from eating disorders, assisting in prevention programs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.