7 resultados para Surgical Procedures, Operative.

em Digital Commons at Florida International University


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background During recent years laparoscopic cholecystectomy has dramatically increased, sometimes resulting in overtreatment. Aim of this work was to retrospectively analyze all laparoscopic cholecystectomies performed in a single center in order to find the percentage of patients whose surgical treatment may be explained with this general trend, and to speculate about the possible causes. Methods 831 patients who underwent a laparoscopic cholecystectomy from 1999 to 2008 were retrospectively analyzed. Results At discharge, 43.08% of patients were operated on because of at least one previous episode of biliary colic before the one at admission; 14.08% of patients presented with acute lithiasic cholecystitis; 14.68% were operated on because of an increase in bilirubin level; 1.56% were operated on because of a previous episode of jaundice with normal bilirubin at admission; 0.72% had gallbladder adenomas, 0.72% had cholangitis, 0.36% had biliodigestive fistula and one patient (0.12%) had acalculous cholecystitis. By excluding all these patients, 21.18% were operated on without indications. Conclusions The broadening of indications for laparoscopic cholecystectomy is undisputed and can be considered a consequence of new technologies that have been introduced, increased demand from patients, and the need for practice by inexperienced surgeons. If not prevented, this trend could continue indefinitely.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Magnesium alloys have been widely explored as potential biomaterials, but several limitations to using these materials have prevented their widespread use, such as uncontrollable degradation kinetics which alter their mechanical properties. In an attempt to further the applicability of magnesium and its alloys for biomedical purposes, two novel magnesium alloys Mg-Zn-Cu and Mg-Zn-Se were developed with the expectation of improving upon the unfavorable qualities shown by similar magnesium based materials that have previously been explored. The overall performance of these novel magnesium alloys has been assessesed in three distinct phases of research: 1) analysing the mechanical properties of the as-cast magnesium alloys, 2) evaluating the biocompatibility of the as-cast magnesium alloys through the use of in-vitro cellular studies, and 3) profiling the degradation kinetics of the as-cast magnesium alloys through the use of electrochemical potentiodynamic polarization techqnique as well as gravimetric weight-loss methods. As compared to currently available shape memory alloys and degradable as-cast alloys, these experimental alloys possess superior as-cast mechanical properties with elongation at failure values of 12% and 13% for the Mg-Zn-Se and Mg-Zn-Se alloys, respectively. This is substantially higher than other as-cast magnesium alloys that have elongation at failure values that range from 7-10%. Biocompatibility tests revealed that both the Mg-Zn-Se and Mg-Zn-Cu alloys exhibit low cytotoxicity levels which are suitable for biomaterial applications. Gravimetric and electrochemical testing was indicative of the weight loss and initial corrosion behavior of the alloys once immersed within a simulated body fluid. The development of these novel as-cast magnesium alloys provide an advancement to the field of degradable metallic materials, while experimental results indicate their potential as cost-effective medical devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Circadian rhythms, patterns of each twenty-four hour period, are found in most bodily functions. The biological cycles of between 20 and 28 hours have a profound effect on an individual's mood, level of performance, and physical well being. Loss of synchrony of these biological rhythms occurs with hospitalization, surgery and anesthesia. The purpose of this comparative, correlational study was to determine the effects of circadian rhythm disruption in post-surgical recovery. Data were collected during the pre-operative and post-operative periods in the following indices: body temperature, blood pressure, heart rate, urine cortisol level and locomotor activity. The data were analyzed by cosinor analysis for evidence of circadian rhythmicity and disruptions throughout the six day study period which encompassed two days pre-operatively, two days post-operatively, and two days after hospital discharge. The sample consisted of five men and five women who served as their own pre-surgical control. The surgical procedures were varied. Findings showed evidence of circadian disruptions in all subjects post-operatively, lending support for the hypotheses.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Biomaterials have been used for more than a century in the human body to improve body functions and replace damaged tissues. Currently approved and commonly used metallic biomaterials such as, stainless steel, titanium, cobalt chromium and other alloys have been found to have adverse effects leading in some cases, to mechanical failure and rejection of the implant. The physical or chemical nature of the degradation products of some implants initiates an adverse foreign body reaction in the tissue. Some metallic implants remain as permanent fixtures, whereas others such as plates, screws and pins used to secure serious fractures are removed by a second surgical procedure after the tissue has healed sufficiently. However, repeat surgical procedures increase the cost of health care and the possibility of patient morbidity. This study focuses on the development of magnesium based biodegradable alloys/metal matrix composites (MMCs) for orthopedic and cardiovascular applications. The Mg alloys/MMCs possessed good mechanical properties and biocompatible properties. Nine different compositions of Mg alloys/MMCs were manufactured and surface treated. Their degradation behavior, ion leaching, wettability, morphology, cytotoxicity and mechanical properties were determined. Alloying with Zn, Ca, HA and Gd and surface treatment resulted in improved mechanical properties, corrosion resistance, reduced cytotoxicity, lower pH and hydrogen evolution. Anodization resulted in the formation of a distinct oxide layer (thickness 5-10 μm) as compared with that produced on mechanically polished samples (~20-50 nm) under ambient conditions. It is envisaged that the findings of this research will introduce a new class of Mg based biodegradable alloys/MMCs and the emergence of innovative cardiovascular and orthopedic implant devices.^

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Intraoperative neurophysiologic monitoring is an integral part of spinal surgeries and involves the recording of somatosensory evoked potentials (SSEP). However, clinical application of IONM still requires anywhere between 200 to 2000 trials to obtain an SSEP signal, which is excessive and introduces a significant delay during surgery to detect a possible neurological damage. The aim of this study is to develop a means to obtain the SSEP using a much less, twelve number of recordings. The preliminary step involved was to distinguish the SSEP with the ongoing brain activity. We first establish that the brain activity is indeed quasi-stationary whereas an SSEP is expected to be identical every time a trial is recorded. An algorithm was developed using Chebychev time windowing for preconditioning of SSEP trials to retain the morphological characteristics of somatosensory evoked potentials (SSEP). This preconditioning was followed by the application of a principal component analysis (PCA)-based algorithm utilizing quasi-stationarity of EEG on 12 preconditioned trials. A unique Walsh transform operation was then used to identify the position of the SSEP event. An alarm is raised when there is a 10% time in latency deviation and/or 50% peak-to-peak amplitude deviation, as per the clinical requirements. The algorithm shows consistency in the results in monitoring SSEP in up to 6-hour surgical procedures even under this significantly reduced number of trials. In this study, the analysis was performed on the data recorded in 29 patients undergoing surgery during which the posterior tibial nerve was stimulated and SSEP response was recorded from scalp. This method is shown empirically to be more clinically viable than present day approaches. In all 29 cases, the algorithm takes 4sec to extract an SSEP signal, as compared to conventional methods, which take several minutes. The monitoring process using the algorithm was successful and proved conclusive under the clinical constraints throughout the different surgical procedures with an accuracy of 91.5%. Higher accuracy and faster execution time, observed in the present study, in determining the SSEP signals provide a much improved and effective neurophysiological monitoring process.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Exposure to certain bloodborne pathogens can prematurely end a person’s life. Healthcare workers (HCWs), especially those who are members of surgical teams, are at increased risk of exposure to these pathogens. The proper use of personal protective equipment (PPE) during operative/invasive procedures reduces that risk. Despite this, some HCWs fail to consistently use PPE as required by federal regulation, accrediting agencies, hospital policy, and professional association standards. The purpose of this mixed methods survey study was to (a) examine factors surgical team members perceive influence choices of wearing or not wearing PPE during operative/invasive procedures and (b) determine what would influence consistent use of PPE by surgical team members. Using an ex post facto, non-experimental design, the memberships of five professional associations whose members comprise surgical teams were invited to complete a mixed methods survey study. The primary research question for the study was: What differences (perceptual and demographic) exist between surgical team members that influence their choices of wearing or not wearing PPE during operative/invasive procedures? Four principal differences were found between surgical team members. Functional (i.e., profession or role based) differences exist between the groups. Age and experience (i.e., time in profession) differences exist among members of the groups. Finally, being a nurse anesthetist influences the use of risk assessment to determine the level of PPE to use. Four common themes emerged across all groups informing the two study purposes. Those themes were: availability, education, leadership, and performance. Subsidiary research questions examined the influence of previous accidental exposure to blood or body fluids, federal regulations, hospital policy and procedure, leaders’ attitudes, and patients’ needs on the use of PPE. Each of these was found to strongly influence surgical team members and their use of PPE during operative/invasive procedures. Implications based on the findings affect organizational policy, purchasing and distribution decisions, curriculum design and instruction, leader behavior, and finally partnership with PPE manufacturers. Surgical team members must balance their innate need to care for patients with their need to protect themselves. Results of this study will help team members, leaders, and educators achieve this balance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Exposure to certain bloodborne pathogens can prematurely end a person’s life. Healthcare workers (HCWs), especially those who are members of surgical teams, are at increased risk of exposure to these pathogens. The proper use of personal protective equipment (PPE) during operative/invasive procedures reduces that risk. Despite this, some HCWs fail to consistently use PPE as required by federal regulation, accrediting agencies, hospital policy, and professional association standards. The purpose of this mixed methods survey study was to (a) examine factors surgical team members perceive influence choices of wearing or not wearing PPE during operative/invasive procedures and (b) determine what would influence consistent use of PPE by surgical team members. Using an ex post facto, non-experimental design, the memberships of five professional associations whose members comprise surgical teams were invited to complete a mixed methods survey study. The primary research question for the study was: What differences (perceptual and demographic) exist between surgical team members that influence their choices of wearing or not wearing PPE during operative/invasive procedures? Four principal differences were found between surgical team members. Functional (i.e., profession or role based) differences exist between the groups. Age and experience (i.e., time in profession) differences exist among members of the groups. Finally, being a nurse anesthetist influences the use of risk assessment to determine the level of PPE to use. Four common themes emerged across all groups informing the two study purposes. Those themes were: availability, education, leadership, and performance. Subsidiary research questions examined the influence of previous accidental exposure to blood or body fluids, federal regulations, hospital policy and procedure, leaders’ attitudes, and patients’ needs on the use of PPE. Each of these was found to strongly influence surgical team members and their use of PPE during operative/invasive procedures. Implications based on the findings affect organizational policy, purchasing and distribution decisions, curriculum design and instruction, leader behavior, and finally partnership with PPE manufacturers. Surgical team members must balance their innate need to care for patients with their need to protect themselves. Results of this study will help team members, leaders, and educators achieve this balance.