39 resultados para superluminescent diode

em Aston University Research Archive


Relevância:

60.00% 60.00%

Publicador:

Resumo:

We describe the results of in-vivo trials of a portable fiber Bragg grating based temperature profile monitoring system. The probe incorporates five Bragg gratings along a single fiber and prevents the gratings from being strained. Illumination is provided by a superluminescent diode, and a miniature CCD based spectrometer is used for demultiplexing. The CCD signal is read into a portable computer through a small A/D interface; the computer then calculates the positions of the center wavelengths of the Bragg gratings, providing a resolution of 0.2°C. Tests were carried out on rabbits undergoing hyperthermia treatment of the kidney and liver via inductive heating of metallic implants and comparison was made with a commercial Fluoroptic thermometry system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We describe the results of in-vivo trials of a portable fiber Bragg grating based temperature profile monitoring system. The probe incorporates five Bragg gratings along a single fiber and prevents the gratings from being strained. Illumination is provided by a superluminescent diode, and a miniature CCD based spectrometer is used for demultiplexing. The CCD signal is read into a portable computer through a small A/D interface; the computer then calculates the positions of the center wavelengths of the Bragg gratings, providing a resolution of 0.2 °C. Tests were carried out on rabbits undergoing hyperthermia treatment of the kidney and liver via inductive heating of metallic implants and comparison was made with a commercial Fluoroptic thermometry system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Generation of picosecond pulses with a peak power in excess of 7W and a duration of 24ps from a gain-switched InGaN diode laser is demonstrated for the first time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: As light-emitting diodes become more common as the light source for low vision aids, the effect of illumination colour temperature on magnifier reading performance was investigated. Methods: Reading ability (maximum reading speed, critical print size, threshold near visual acuity) using Radner charts and subjective preference was assessed for 107 participants with visual impairment using three stand magnifiers with light emitting diode illumination colour temperatures of 2,700 K, 4,500 K and 6,000 K. The results were compared with distance visual acuity, prescribed magnification, age and the primary cause of visual impairment. Results: Reading speed, critical print size and near visual acuity were unaffected by illumination colour temperature (p > 0.05). Reading metrics decreased with worsening acuity and higher levels of prescribed magnification but acuity was unaffected by age. Each colour temperature was preferred and disliked by a similar number of patients and was unrelated to distance visual acuity, prescribed magnification and age (p > 0.05). Patients had better near acuity (p = 0.002), critical print size (p = 0.034) and maximum reading speed (p <0.001), and the improvement in near from distance acuity was greater (p = 0.004) with their preferred rather than least-liked colour temperature illumination. Conclusion: A range of colour temperature illuminations should be offered to all visually impaired individuals prescribed with an optical magnifier for near tasks to optimise subjective and objective benefits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis presents a detailed, experiment-based study of generation of ultrashort optical pulses from diode lasers. Simple and cost-effective techniques were used to generate high power, high quality optical short pulses at various wavelength windows. The major achievements presented in the thesis is summarised as follows. High power pulses generation is one of the major topics discussed in the thesis. Although gain switching is the simplest way for ultrashort pulse generation, it proves to be quite effective to deliver high energy pulses on condition that the pumping pulses with extremely fast rising time and high enough amplitude are applied on specially designed pulse generators. In the experiment on a grating-coupled surface emitting laser (GCSEL), peak power as high as 1W was achieved even when its spectral bandwidth was controlled within 0.2nm. Another experiment shows violet picosecond pulses with peak power as high as 7W was achieved when the intensive electrical pulses were applied on optimised DC bias to pump on InGaN violet diode laser. The physical mechanism of this phenomenon, as we considered, may attributed to the self-organised quantum dots structure in the laser. Control of pulse quality, including spectral quality and temporal profile, is an important issue for high power pulse generation. The ways to control pulse quality described in the thesis are also based on simple and effective techniques. For instance, GCSEL used in our experiment has a specially designed air-grating structure for out-coupling of optical signals; hence, a tiny flat aluminium mirror was placed closed to the grating section and resulted in a wavelength tuning range over 100nm and the best side band suppression ratio of 40dB. Self-seeding, as an effective technique for spectral control of pulsed lasers, was demonstrated for the first time in a violet diode laser. In addition, control of temporal profile of the pulse is demonstrated in an overdriven DFB laser. Wavelength tuneable fibre Bragg gratings were used to tailor the huge energy tail of the high power pulse. The whole system was compact and robust. The ultimate purpose of our study is to design a new family of compact ultrafast diode lasers. Some practical ideas of laser design based on gain-switched and Q-switched devices are also provided in the end.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Self-seeded, gain-switched operation of an InGaN multi-quantum-well diode laser is reported for the first time. Narrow-line, wavelength-tunable, picosecond pulses have been generated from a standard, uncoated diode laser with an external feedback.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Efficient suppression of relaxation oscillations in the output signal from an overdriven gain-switched laser diode was demonstrated. Several quantum-well distributed feedback laser diodes from different manufacturers were used for experimental analysis. A five-fold increase in the peak power was achieved for the tail-free operation. It was found that spectral filtering removed the nonlinearly chirped components resulting in pulse shortening by a factor of three.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on a theoretical study of an interferometric system in which half of a collimated beam from a broadband optical source is intercepted by a glass slide, the whole beam subsequently being incident on a diffraction grating and the resulting spectrum being viewed using a linear CCD array. Using Fourier theory, we derive the expression of the intensity distribution across the CCD array. This expression is then examined for non-cavity and cavity sources for different cases determined by the direction from which the slide is inserted into the beam and the source bandwidth. The theoretical model shows that the narrower the source linewidth, the higher the deviation of the Talbot bands' visibility (as it is dependent on the path imbalance) from the previously known triangular shape. When the source is a laser diode below threshold, the structure of the CCD signal spectrum is very complex. The number of components present simultaneously increases with the number of grating lines and decreases with the laser cavity length. The model also predicts the appearance of bands in situations not usually associated with Talbot bands.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the problems encountered when replacing a tungsten filament lamp with a laser diode in a set-up for displaying Talbot bands using a diffraction grating. It is shown that the band pattern is rather complex and strong interference signals may exist in situations where Talbot bands are not normally expected to appear. In these situations, the period of the bands increases with the optical path difference (OPD). The visibility of bands as dependence on path imbalance is obtained by suitably obstructing halfway into the arms of a Michelson interferometer using opaque screens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a technique applicable to interferometric systems illuminated by a laser diode, whereby the optical path difference is recovered by means of sinusoidal modulation of the laser emission frequency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interferometric sensors for slowly varying measurands, such as temperature or pressure, require a long term frequency stability of the source. We describe a system for frequency locking a laser diode to an atomic transition in a hollow cathode lamp using the optogalvanic effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present an imaging system based on light emitting diode (LED) illumination that produces multispectral optical images of the human ocular fundus. It uses a conventional fundus camera equipped with a high power LED light source and a highly sensitive electron-multiplying charge coupled device camera. It is able to take pictures at a series of wavelengths in rapid succession at short exposure times, thereby eliminating the image shift introduced by natural eye movements (saccades). In contrast with snapshot systems the images retain full spatial resolution. The system is not suitable for applications where the full spectral resolution is required as it uses discrete wavebands for illumination. This is not a problem in retinal imaging where the use of selected wavelengths is common. The modular nature of the light source allows new wavelengths to be introduced easily and at low cost. The use of wavelength-specific LEDs as a source is preferable to white light illumination and subsequent filtering of the remitted light as it minimizes the total light exposure of the subject. The system is controlled via a graphical user interface that enables flexible control of intensity, duration, and sequencing of sources in synchrony with the camera. Our initial experiments indicate that the system can acquire multispectral image sequences of the human retina at exposure times of 0.05 s in the range of 500-620 nm with mean signal to noise ratio of 17 dB (min 11, std 4.5), making it suitable for quantitative analysis with application to the diagnosis and screening of eye diseases such as diabetic retinopathy and age-related macular degeneration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Self-seeded, gain-switched operation of an InGaN multi-quantum-well laser diode has been demonstrated for the first time. An external cavity comprising Littrow geometry was implemented for spectral control of pulsed operation. The feedback was optimized by adjusting the external cavity length and the driving frequency of the laser. The generated pulses had a peak power in excess of 400mW, a pulse duration of 60ps, a spectral linewidth of 0.14nm and maximum side band suppression ratio of 20dB. It was tunable within the range of 3.6nm centered at a wavelength of 403nm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A high-power diode-cladding-pumped Ho-doped fluoride glass fiber laser operating in cascade mode is demonstrated. The 5|6 -> 5|7 and 5|7 -> 5|8 laser transitions produced 0:77W at a measured slope efficiency of 12.4% and 0:24Wat a measured slope efficiency of 5.2%, respectively. Using a long fiber length, which forced a large threshold for the 5|7 -> 5|8 transition, a wavelength of 3:002 µm was measured at maximum output power, making this system the first watt-level fiber laser operating in the mid-IR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A high-power diode-cladding-pumped Ho-doped fluoride glass fiber laser operating in cascade mode is demonstrated. The 5|6 -> 5|7 and 5|7 -> 5|8 laser transitions produced 0:77W at a measured slope efficiency of 12.4% and 0:24Wat a measured slope efficiency of 5.2%, respectively. Using a long fiber length, which forced a large threshold for the 5|7 -> 5|8 transition, a wavelength of 3:002 µm was measured at maximum output power, making this system the first watt-level fiber laser operating in the mid-IR.