33 resultados para spectrum sensing performance
em Aston University Research Archive
Resumo:
Highly sensitive and selective detection of volatile organic compounds (VOCs) with fast response time is imperative based on safety requirements, yet often remains a challenge. Herein, we propose an effective solution, preparing a novel gas sensor comprised of amorphous nanoflake arrays (a-NFAs) with specific surface groups. The sensor was produced via an extremely simple process in which a-NFAs of CdO were deposited directly onto an interdigital electrode immersed in a chemical bath under ambient conditions. Upon exposure to a widely used VOC, diethyl ether (DEE), the sensor exhibits excellent performance, more specifically, the quickest response, lowest detection limit and highest selectivity ever reported for DEE as a target gas. The superior gas-sensing properties of the prepared a-NFAs are found to arise from their open trumpet-shaped morphology, defect-rich amorphous nature, and surface CO groups.
Resumo:
IEEE 802.11 standard is the dominant technology for wireless local area networks (WLANs). In the last two decades, the Distributed coordination function (DCF) of IEEE 802.11 standard has become the one of the most important media access control (MAC) protocols for mobile ad hoc networks (MANETs). The DCF protocol can also be combined with cognitive radio, thus the IEEE 802.11 cognitive radio ad hoc networks (CRAHNs) come into being. There were several literatures which focus on the modeling of IEEE 802.11 CRAHNs, however, there is still no thorough and scalable analytical models for IEEE 802.11 CRAHNs whose cognitive node (i.e., secondary user, SU) has spectrum sensing and possible channel silence process before the MAC contention process. This paper develops a unified analytical model for IEEE 802.11 CRAHNs for comprehensive MAC layer queuing analysis. In the proposed model, the SUs are modeled by a hyper generalized 2D Markov chain model with an M/G/1/K model while the primary users (PUs) are modeled by a generalized 2D Markov chain and an M/G/1/K model. The performance evaluation results show that the quality-of-service (QoS) of both the PUs and SUs can be statistically guaranteed with the suitable settings of duration of channel sensing and silence phase in the case of under loading.
Resumo:
We propose a novel technique for optical liquid level sensing. The technique takes advantage of an optical spectrum spreading technique and directly measures liquid level with a digital format. The performance of the sensor does not suffer from changes of environmental variables and system variables. Due to its distinct measurement principle both high resolution and a large measurement range can be achieved simultaneously.
Resumo:
This thesis presents details on the fabrication of microwave transversal filters using fibre Bragg grating arrays and the building of fibre Bragg grating based magnetic-field sensors. Some theoretical background about fibre Bragg gratings, photosensitivity, fibre Bragg grating sensors and filters are presented. Fibre Bragg grating sensors in other industrial applications are highlighted. Some sensing principles are also introduced. Experimental work is carried out to demonstrate a magnetic-field sensor using an established fibre Bragg grating strain sensor. System performance and trade-off are discussed. The most important part of this thesis is on the fabrication of photonic transversal filter using fibre Bragg grating arrays. In order to improve the filter performance, a novel tap multiplexing structure is presented. Further improving approaches such as apodisation are also investigated. The basis of nonrecirculating filter, some structure and performance are introduced.
Resumo:
This thesis presents an experimental investigation into several applications of the Raman scattering effect in communication optical fibres as well as how some of these applications can be modified to enhance the resulting performance. The majority of the work contained within is based on laboratory results using many commercially available components. The results can be divided into and presented in three main parts: Firstly, a novel application of a known effect is used to broaden Raman pump light in order to achieve a more continuous distribution of gain with respect to wavelength. Multiple experimental results are presented, all based around the prior spreading of the pump spectrum before being used in the desired transmission fibre. Gathered results show that a notable improvement can be obtained from applying such a technique along with the scope for further optimisation work. Secondly, an investigation into the interaction between the well known effect of Four Wave Mixing (FWM) and Raman scattering is provided. The work provides an introduction to the effect as well commenting on previous literature regarding the effect and its mitigation. In response to existing research experimental results are provided detailing some limitations of proposed schemes along with concepts of how further alleviation from the deleterious effects maybe obtained. Lastly, the distributed nature of the Raman gain process is explored. A novel technique on how a near constant distribution of gain can be employed is implemented practically. The application of distributed gain is then applied to the generation of optical pulses with special mathematical properties within a laboratory setting and finally the effect of pump noise upon distributed gain techniques is acknowledged.
Resumo:
Through the application of novel signal processing techniques we are able to measure physical measurands with both high accuracy and low noise susceptibility. The first interrogation scheme is based upon a CCD spectrometer. We compare different algorithms for resolving the Bragg wavelength from a low resolution discrete representation of the reflected spectrum, and present optimal processing methods for providing a high integrity measurement from the reflection image. Our second sensing scheme uses a novel network of sensors to measure the distributive strain response of a mechanical system. Using neural network processing methods we demonstrate the measurement capabilities of a scalable low-cost fibre Bragg grating sensor network. This network has been shown to be comparable with the performance of existing fibre Bragg grating sensing techniques, at a greatly reduced implementation cost.
Resumo:
A series of surface plasmonic fibre devices were fabricated using multiple coatings deposited on a lapped section of a single mode fibre. Coupling from the guided mode to surface plasmons was promoted following UV laser irradiation of the coated region through a phase mask, which generated a surface relief grating structure. The devices showed high spectral sensitivities and strong coupling for low refractive indices as compared to other grating-type fibre devices. The plasmonic devices were used to detect the variation in the refractive indices of alkane gases with measured wavelength and coupling sensitivity to index of 3400 nm RIU-1 and 8300 dB RIU-1, respectively. As a demonstration of the performance of these gas sensors, a minimum concentration of 2% by volume of butane in ethane was achieved.
Resumo:
A novel biosensing system based on a micromachined rectangular silicon membrane is proposed and investigated in this paper. A distributive sensing scheme is designed to monitor the dynamics of the sensing structure. An artificial neural network is used to process the measured data and to identify cell presence and density. Without specifying any particular bio-application, the investigation is mainly concentrated on the performance testing of this kind of biosensor as a general biosensing platform. The biosensing experiments on the microfabricated membranes involve seeding different cell densities onto the sensing surface of membrane, and measuring the corresponding dynamics information of each tested silicon membrane in the form of a series of frequency response functions (FRFs). All of those experiments are carried out in cell culture medium to simulate a practical working environment. The EA.hy 926 endothelial cell lines are chosen in this paper for the bio-experiments. The EA.hy 926 endothelial cell lines represent a particular class of biological particles that have irregular shapes, non-uniform density and uncertain growth behaviour, which are difficult to monitor using the traditional biosensors. The final predicted results reveal that the methodology of a neural-network based algorithm to perform the feature identification of cells from distributive sensory measurement has great potential in biosensing applications.
Resumo:
A novel form of low coherence interferometric sensor is described. The channelled spectrum produced by illuminating a sensing interferometer with a broadband source is analysed directly using a CCD array. The system currently provides unambiguous measurement over a range of 1.5 mm with an accuracy of better than 6 µm.
Resumo:
Purpose: This cross-sectional study was designed to determine whether the academic performance of optometry undergraduates is influenced by enrolment status, learning style or gender. Methods: Three hundred and sixty undergraduates in all 3 years of the optometry degree course at Aston University during 2008–2009 were asked for their informed consent to participate in this study. Enrolment status was known from admissions records. An Index of Learning Styles (http://www4.nscu.edu/unity/lockers/users/f/felder/public/Learning-Styles.html) determined learning style preference with respect to four different learning style axes; active-reflective, sensing-intuitive, visual-verbal and sequential-global. The influence of these factors on academic performance was investigated. Results: Two hundred and seventy students agreed to take part (75% of the cohort). 63% of the sample was female. There were 213 home non-graduates (entrants from the UK or European Union without a bachelor’s degree or higher), 14 home graduates (entrants from the UK or European Union with a bachelor’s degree or higher), 28 international non-graduates (entrants from outside the UK or European Union without a bachelor’s degree or higher) and 15 international graduates (entrants from outside the UK or European Union with a bachelor’s degree or higher). The majority of students were balanced learners (between 48% and 64% across four learning style axes). Any preferences were towards active, sensing, visual and sequential learning styles. Of the factors investigated in this study, learning styles were influenced by gender; females expressed a disproportionate preference for the reflective and visual learning styles. Academic performance was influenced by enrolment status; international graduates (95% confidence limits: 64–72%) outperformed all other student groups (home non graduates, 60–62%; international non graduates, 55–63%) apart from home graduates (57–69%). Conclusion: Our research has shown that the majority of optometry students have balanced learning styles and, from the factors studied, academic performance is only influenced by enrolment status. Although learning style questionnaires offer suggestions on how to improve learning efficacy, our findings indicate that current teaching methods do not need to be altered to suit varying learning style preferences as balanced learning styles can easily adapt to any teaching style (Learning Styles and Pedagogy in Post-16 Learning: A Systematic and Critical Review. London, UK: Learning and Skills Research Centre, 2004).
Resumo:
Existing wireless systems are normally regulated by a fixed spectrum assignment strategy. This policy leads to an undesirable situation that some systems may only use the allocated spectrum to a limited extent while others have very serious spectrum insufficiency situation. Dynamic Spectrum Access (DSA) is emerging as a promising technology to address this issue such that the unused licensed spectrum can be opportunistically accessed by the unlicensed users. To enable DSA, the unlicensed user shall have the capability of detecting the unoccupied spectrum, controlling its spectrum access in an adaptive manner, and coexisting with other unlicensed users automatically. In this article, we propose a radio system Transmission Opportunity-based spectrum access control protocol with the aim to improve spectrum access fairness and ensure safe coexistence of multiple heterogeneous unlicensed radio systems. In the scheme, multiple radio systems will coexist and dynamically use available free spectrum without interfering with licensed users. Simulation is carried out to evaluate the performance of the proposed scheme with respect to spectrum utilisation, fairness and scalability. Comparing with the existed studies, our strategy is able to achieve higher scalability and controllability without degrading spectrum utilisation and fairness performance.
Resumo:
A real-time three-dimensional (3D) object sensing and reconstruction scheme is presented that can be applied on any arbitrary corporeal shape. Operation is demonstrated on several calibrated objects. The system uses curvature sensors based upon in-line fiber Bragg gratings encapsulated in a low-temperature curing synthetic silicone. New methods to quantitatively evaluate the performance of a 3D object-sensing scheme are developed and appraised. It is shown that the sensing scheme yields a volumetric error of 1% to 9%, depending on the object.
Resumo:
Minimal access procedures in surgery offer benefits of reduced patient recovery time and less pain, yet for the surgeon the task is more complex, as both tactile and visual perception of the working site is reduced. In this paper, experimental evidence of the performance of a novel sensing system embedded in an actuated flexible digit element is presented. The digit represents a steerable tip element of devices such as endoscopes and laparoscopes. This solution is able to discriminate types of contact and tissue interaction, and to feed back this information with the shape of the flexible digit. As an alternative to this information, force level, force distribution, and other quantifiable descriptors can also be evaluated. These can be used to aid perception in processes such as navigation and investigation of tissues through palpation. The solution is pragmatic, and by virtue of its efficient mechanical construction and a polymer construction, it offers opportunities for a disposable element with suitability for magnetic resonance imaging (MRI) and other scanning environments. By using only four photonics sensing elements, full perception of tissue contact and the shape of the actuated digit can be described in the feedback of this information. The distributive sensory method applied to the sensory signals relies on the coupled values of the sensory data transients of the four deployed sensing elements to discriminate tissue interaction directly in near real time.
Resumo:
A novel form of low coherence interferometric sensor is described. The channelled spectrum produced by illuminating a sensing interferometer with a broadband source is analysed directly using a CCD array. The system currently provides unambiguous measurement over a range of 1.5 mm with an accuracy of better than 6 µm.
Resumo:
Minimal access procedures in surgery offer benefits of reduced patient recovery time and less pain, yet for the surgeon the task is more complex, as both tactile and visual perception of the working site is reduced. In this paper, experimental evidence of the performance of a novel sensing system embedded in an actuated flexible digit element is presented. The digit represents a steerable tip element of devices such as endoscopes and laparoscopes. This solution is able to discriminate types of contact and tissue interaction, and to feed back this information with the shape of the flexible digit. As an alternative to this information, force level, force distribution, and other quantifiable descriptors can also be evaluated. These can be used to aid perception in processes such as navigation and investigation of tissues through palpation. The solution is pragmatic, and by virtue of its efficient mechanical construction and a polymer construction, it offers opportunities for a disposable element with suitability for magnetic resonance imaging (MRI) and other scanning environments. By using only four photonics sensing elements, full perception of tissue contact and the shape of the actuated digit can be described in the feedback of this information. The distributive sensory method applied to the sensory signals relies on the coupled values of the sensory data transients of the four deployed sensing elements to discriminate tissue interaction directly in near real time.