13 resultados para Validation of analytical methods
em Aston University Research Archive
Resumo:
Lipid peroxidation products like malondialdehyde, 4-hydroxynonenal and F(2)-isoprostanes are widely used as markers of oxidative stress in vitro and in vivo. This study reports the results of a multi-laboratory validation study by COST Action B35 to assess inter-laboratory and intra-laboratory variation in the measurement of lipid peroxidation. Human plasma samples were exposed to UVA irradiation at different doses (0, 15 J, 20 J), encoded and shipped to 15 laboratories, where analyses of malondialdehyde, 4-hydroxynonenal and isoprostanes were conducted. The results demonstrate a low within-day-variation and a good correlation of results observed on two different days. However, high coefficients of variation were observed between the laboratories. Malondialdehyde determined by HPLC was found to be the most sensitive and reproducible lipid peroxidation product in plasma upon UVA treatment. It is concluded that measurement of malondialdehyde by HPLC has good analytical validity for inter-laboratory studies on lipid peroxidation in human EDTA-plasma samples, although it is acknowledged that this may not translate to biological validity.
Resumo:
The involvement of oxidatively modified low density lipoprotein (LDL) in the development of CHD is widely described. We have produced two antibodies, recognizing the lipid oxidation product malondialdehyde (MDA) on whole LDL or ApoB-100. The antibodies were utilized in the development of an ELISA for quantitation of MDA-LDL in human plasma. Intra- and inter-assay coefficients of variation (% CV) were measured as 4.8 and 7.7%, respectively, and sensitivity of the assay as 0.04 μg/ml MDA-LDL. Recovery of standard MDA-LDL from native LDL was 102%, indicating the ELISA to be specific with no interference from other biomolecules. Further validation of the ELISA was carried out against two established methods for measurement of lipid peroxidation products, MDA by HPLC and F2-isoprostanes by GC-MS. Results indicated that MDA-LDL is formed at a later stage of oxidation than either MDA or F2- isoprostanes. In vivo analysis demonstrated that the ELISA was able to determine steady-state concentrations of plasma MDA-LDL (an end marker of lipid peroxidation). A reference range of 34.3 ± 8.8 μg/ml MDA-LDL was established for healthy individuals. Further, the ELISA was used to show significantly increased plasma MDA-LDL levels in subjects with confirmed ischemic heart disease, and could therefore possibly be of benefit as a diagnostic tool for assessing CHD risk. © 2003 Elsevier Inc.
Resumo:
Purpose: The use of PHMB as a disinfectant in contact lens multipurpose solutions has been at the centre of much debate in recent times, particularly in relation to the issue of solution induced corneal staining. Clinical studies have been carried out which suggest different effects with individual contact lens materials used in combination with specific PHMB containing care regimes. There does not appear to be, however, a reliable analytical technique that would detect and quantify with any degree of accuracy the specific levels of PHMB that are taken up and released from individual solutions by the various contact lens materials. Methods: PHMB is a mixture of positively charged polymer units of varying molecular weight that has maximum absorbance wavelength of 236 nm. On the basis of these properties a range of assays including capillary electrophoresis, HPLC, a nickelnioxime colorimetric technique, mass spectrophotometry, UV spectroscopy and ion chromatography were assessed paying particular attention to each of their constraints and detection levels. Particular interest was focused on the relative advantage of contactless conductivity compared to UV and mass spectrometry detection in capillary electrophoresis (CE). This study provides an overview of the comparative performance of these techniques. Results: The UV absorbance of PHMB solutions, ranging from 0.0625 to 50 ppm was measured at 236 nm. Within this range the calibration curve appears to be linear however, absorption values below 1 ppm (0.0001%) were extremely difficult to reproduce. The concentration of PHMB in solutions is in the range of 0.0002–0.00005% and our investigations suggest that levels of PHMB below 0.0001% (levels encountered in uptake and release studies) can not be accurately estimated, in particular when analysing complex lens care solutions which can contain competitively absorbing, and thus interfering, species in the solution. The use of separative methodologies, such as CE using UV detection alone is similarly limited. Alternative techniques including contactless conductivity detection offer greater discrimination in complex solutions together with the opportunity for dual channel detection. Preliminary results achieved by TraceDec1 contactless conductivity detection, (Gain 150%, Offset 150) in conjunction with the Agilent capillary electrophoresis system using a bare fused silica capillary (extended light path, 50 mid, total length 64.5 cm, effective length 56 cm) and a cationic buffer at pH 3.2, exhibit great potential with reproducible PHMB split peaks. Conclusions: PHMB-based solutions are commonly associated with the potential to invoke corneal staining in combination with certain contact lens materials. However this terminology ‘PHMBbased solution’ is used primarily because PHMB itself has yet to be adequately implicated as the causative agent of the staining and compromised corneal cell integrity. The lack of well characterised adequately sensitive assays, coupled with the range of additional components that characterise individual care solutions pose a major barrier to the investigation of PHMB interactions in the lenswearing eye.
Resumo:
This thesis is an exploration of the organisation and functioning of the human visual system using the non-invasive functional imaging modality magnetoencephalography (MEG). Chapters one and two provide an introduction to the ‘human visual system and magnetoencephalographic methodologies. These chapters subsequently describe the methods by which MEG can be used to measure neuronal activity from the visual cortex. Chapter three describes the development and implementation of novel analytical tools; including beamforming based analyses, spectrographic movies and an optimisation of group imaging methods. Chapter four focuses on the use of established and contemporary analytical tools in the investigation of visual function. This is initiated with an investigation of visually evoked and induced responses; covering visual evoked potentials (VEPs) and event related synchronisation/desynchronisation (ERS/ERD). Chapter five describes the employment of novel methods in the investigation of cortical contrast response and demonstrates distinct contrast response functions in striate and extra-striate regions of visual cortex. Chapter six use synthetic aperture magnetometry (SAM) to investigate the phenomena of visual cortical gamma oscillations in response to various visual stimuli; concluding that pattern is central to its generation and that it increases in amplitude linearly as a function of stimulus contrast, consistent with results from invasive electrode studies in the macaque monkey. Chapter seven describes the use of driven visual stimuli and tuned SAM methods in a pilot study of retinotopic mapping using MEG; finding that activity in the primary visual cortex can be distinguished in four quadrants and two eccentricities of the visual field. Chapter eight is a novel implementation of the SAM beamforming method in the investigation of a subject with migraine visual aura; the method reveals desynchronisation of the alpha and gamma frequency bands in occipital and temporal regions contralateral to observed visual abnormalities. The final chapter is a summary of main conclusions and suggested further work.
Resumo:
BACKGROUND: Gilles de la Tourette syndrome (GTS) is a chronic childhood-onset neuropsychiatric disorder with a significant impact on patients' health-related quality of life (HR-QOL). Cavanna et al. (Neurology 2008; 71: 1410-1416) developed and validated the first disease-specific HR-QOL assessment tool for adults with GTS (Gilles de la Tourette Syndrome-Quality of Life Scale, GTS-QOL). This paper presents the translation, adaptation and validation of the GTS-QOL for young Italian patients with GTS. METHODS: A three-stage process involving 75 patients with GTS recruited through three Departments of Child and Adolescent Neuropsychiatry in Italy led to the development of a 27-item instrument (Gilles de la Tourette Syndrome-Quality of Life Scale in children and adolescents, C&A-GTS-QOL) for the assessment of HR-QOL through a clinician-rated interview for 6-12 year-olds and a self-report questionnaire for 13-18 year-olds. RESULTS: The C&A-GTS-QOL demonstrated satisfactory scaling assumptions and acceptability. Internal consistency reliability was high (Cronbach's alpha > 0.7) and validity was supported by interscale correlations (range 0.4-0.7), principal-component factor analysis and correlations with other rating scales and clinical variables. CONCLUSIONS: The present version of the C&A-GTS-QOL is the first disease-specific HR-QOL tool for Italian young patients with GTS, satisfying criteria for acceptability, reliability and validity. © 2013 - IOS Press and the authors. All rights reserved.
Resumo:
Objective - The aim of the current study was to validate child (PFA-QL) and parent–proxy (PFA-QL-PF) versions of the scale in a specialist allergy clinic and in parents of children with food allergy. Methods - For the clinic sample, a generic QoL scale (PedsQL) and the PFA-QL were completed by 103 children (age 6–16 yrs) with peanut or tree nut allergy; test–retest reliability of the PFA-QL was tested in 50 stable patients. For the non-clinical sample, 756 parents of food allergic children completed the PFA-QL-PF, the Child Health Questionnaire (CHQ-PF50), Food Allergy Quality of Life Parental Burden Scale (FAQL-PB) and a Food Allergy Impact Measure. Results - The PFA-QL and PFA-QL-PF had good internal consistency (a's of 0.77–0.82), and there was moderate-to-good agreement between the generic- and disease-specific questionnaires. The PFA-QL was stable over time in the clinic sample, and in both samples, girls were reported to have poorer QoL than boys. Conclusions - The PFA-QL and PFA-QL-PF are reliable and valid scales for use in both clinical and non-clinical populations. Unlike other available tools, they were developed and validated in the UK and thus provide a culture-specific choice for research, clinical trials and clinical practice in the UK. Validation in other countries is now needed.
Resumo:
Purpose - Food allergy can have a profound effect on quality of life (QoL) of the family. The Food Allergy Quality of Life—Parental Burden Questionnaire (FAQL-PB) was developed on a US sample to assess the QoL of parents with food allergic children. The aim of this study was to examine the reliability and validity of the FAQL-PB in a UK sample and to assess the effect of asking about parental burden in the last week compared with parental burden in general, with no time limit for recall given. Methods - A total of 1,200 parents who had at least one child with food allergy were sent the FAQL-PB and the Child Health Questionnaire (CHQ-PF50); of whom only 63 % responded. Results - Factor analysis of the FAQL-PB revealed two factors: limitations on life and emotional distress. The total scale and the two sub-scales had high internal reliability (all a > 0.85). There were small to moderate but significant correlations between total FAQL-PB scores and health and parental impact measures on the CHQ-PF50 (p < 0.01). Significantly greater parental burden was reported for the no-time limited compared with the time-limited version (p < 0.01). Conclusions - The FAQL-PB is a reliable and valid measure for use in the UK. The scale could be used in clinic to assess the physical and emotional quality of life in addition to the impact on total quality of life.
Resumo:
Protein carbonyls are widely analysed as a measure of protein oxidation. Several different methods exist for their determination. A previous study had described orders of magnitude variance that existed when protein carbonyls were analysed in a single laboratory by ELISA using different commercial kits. We have further explored the potential causes of variance in carbonyl analysis in a ring study. A soluble protein fraction was prepared from rat liver and exposed to 0, 5 and 15 min of UV irradiation. Lyophilised preparations were distributed to six different laboratories that routinely undertook protein carbonyl analysis across Europe. ELISA and Western blotting techniques detected an increase in protein carbonyl formation between 0 and 5 min of UV irradiation irrespective of method used. After irradiation for 15 min, less oxidation was detected by half of the laboratories than after 5 min irradiation. Three of the four ELISA carbonyl results fell within 95% confidence intervals. Likely errors in calculating absolute carbonyl values may be attributed to differences in standardisation. Out of up to 88 proteins identified as containing carbonyl groups after tryptic cleavage of irradiated and control liver proteins, only seven were common in all three liver preparations. Lysine and arginine residues modified by carbonyls are likely to be resistant to tryptic proteolysis. Use of a cocktail of proteases may increase the recovery of oxidised peptides. In conclusion, standardisation is critical for carbonyl analysis and heavily oxidised proteins may not be effectively analysed by any existing technique.
Resumo:
OBJECTIVE: The authors developed and validated a clozapine-specific side-effects scale capable of eliciting the subjectively unpleasant side-effects of clozapine. METHODS: Questions from the original Glasgow Antipsychotic Side-effects Scale (GASS) were compared to a list of the most commonly reported clozapine side-effects and those with a significant subjective burden were included in the GASS for Clozapine (GASS-C). The original authors of the GASS and a group of mental health professionals from the UK and Ireland were enlisted to comment on the questions in the GASS-C based on their clinical experience. 110 clozapine outpatients from two sites completed the GASS-C, the original GASS and a repeat GASS-C. Statistical analyses were performed using SPSS for Windows version 19. RESULTS: The GASS-C was shown to have construct validity, in that Spearman's correlation coefficient was 0.816 (p<0.001) with the original GASS, whilst Cohen's kappa coefficient was >0.77 (p<0.001) for one question and >0.81 (p<0.001) for remaining relevant questions. GASS-C was also shown to have strong test-retest reliability, in that Cronbach's alpha coefficient was >0.907 (p<0.001), whilst Cohen's kappa coefficient was >0.81 (p<0.001) for 12 questions and >0.61 (p<0.001) for the remaining four questions. CONCLUSION: The GASS-C is a valid and reliable clinical tool to enable a systematic assessment of the subjectively unpleasant side-effects of clozapine. Future research should focus on how the scale can be utilised as a clinical tool to improve real-world outcomes such as adherence to clozapine therapy and quality of life.
Resumo:
A new mesoscale simulation model for solids dissolution based on an computationally efficient and versatile digital modelling approach (DigiDiss) is considered and validated against analytical solutions and published experimental data for simple geometries. As the digital model is specifically designed to handle irregular shapes and complex multi-component structures, use of the model is explored for single crystals (sugars) and clusters. Single crystals and the cluster were first scanned using X-ray microtomography to obtain a digital version of their structures. The digitised particles and clusters were used as a structural input to digital simulation. The same particles were then dissolved in water and the dissolution process was recorded by a video camera and analysed yielding: the overall dissolution times and images of particle size and shape during the dissolution. The results demonstrate the coherence of simulation method to reproduce experimental behaviour, based on known chemical and diffusion properties of constituent phase. The paper discusses how further sophistications to the modelling approach will need to include other important effects such as complex disintegration effects (particle ejection, uncertainties in chemical properties). The nature of the digital modelling approach is well suited to for future implementation with high speed computation using hybrid conventional (CPU) and graphical processor (GPU) systems.
Resumo:
This paper presents a theoretical model on the vibration analysis of micro scale fluid-loaded rectangular isotropic plates, based on the Lamb's assumption of fluid-structure interaction and the Rayleigh-Ritz energy method. An analytical solution for this model is proposed, which can be applied to most cases of boundary conditions. The dynamical experimental data of a series of microfabricated silicon plates are obtained using a base-excitation dynamic testing facility. The natural frequencies and mode shapes in the experimental results are in good agreement with the theoretical simulations for the lower order modes. The presented theoretical and experimental investigations on the vibration characteristics of the micro scale plates are of particular interest in the design of microplate based biosensing devices. Copyright © 2009 by ASME.
Resumo:
Background. The Scale for Psychosocial Factors in Food Allergy (SPS-FA) is based on the biopsychosocial model of health and was developed and validated in Chile to measure the interaction between psychological variables and allergy symptoms in the child. We sought to validate this scale in an English speaking population and explore its relationship with parental quality of life, self-efficacy, and mental health. Methods. Parents (n = 434) from the general population in the UK, who had a child with a clinical diagnosis of food allergy, completed the SPS-FA and validated scales on food allergy specific parental quality of life (QoL), parental self-efficacy, and general mental health. Findings. The SPS-FA had good internal consistency (alphas = .61-.86). Higher scores on the SPS-FA significantly correlated with poorer parental QoL, self-efficacy, and mental health. All predictors explained 57% of the variance in SPS-FA scores with QoL as the biggest predictor (β = .52). Discussion. The SPS-FA is a valid scale for use in the UK and provides a holistic view of the impact of food allergy on the family. In conjunction with health-related QoL measures, it can be used by health care practitioners to target care for patients and evaluate psychological interventions for improvement of food allergy management.