18 resultados para Speckle tracking liver motion correction contrast-enhanced ultrasound

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Blurred edges appear sharper in motion than when they are stationary. We have previously shown how such distortions in perceived edge blur may be explained by a model which assumes that luminance contrast is encoded by a local contrast transducer whose response becomes progressively more compressive as speed increases. To test this model further, we measured the sharpening of drifting, periodic patterns over a large range of contrasts, blur widths, and speeds Human Vision. The results indicate that, while sharpening increased with speed, it was practically invariant with contrast. This contrast invariance cannot be explained by a fixed compressive nonlinearity since that predicts almost no sharpening at low contrasts.We show by computational modelling of spatiotemporal responses that, if a dynamic contrast gain control precedes the static nonlinear transducer, then motion sharpening, its speed dependence, and its invariance with contrast can be predicted with reasonable accuracy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction - Monocytes, with 3 different subsets, are implicated in the initiation and progression of the atherosclerotic plaque contributing to plaque instability and rupture. Mon1 are the “classical” monocytes with inflammatory action, whilst Mon3 are considered reparative with fibroblast deposition ability. The function of the newly described Mon2 subset is yet to be fully described. In PCI era, fewer patients have globally reduced left ventricular ejection fraction post infarction, hence the importance of studying regional wall motion abnormalities and deformation at segmental levels using longitudinal strain. Little is known of the role for the 3 monocyte subpopulations in determining global strain in ST elevation myocardial infarction patients (STEMI). Conclusion In patients with normal or mildly impaired EF post infarction, higher counts of Mon1 and Mon2 are correlated with GLS within 7 days and at 6 months of remodelling post infarction. Adverse clinical outcomes in patients with reduced convalescent GLS were predicted with Mon1 and Mon2 suggestive of an inflammatory role for the newly identified Mon2 subpopulation. These results imply an important role for monocytes in myocardial healing when assessed by subclinical ventricular function indices. Methodology - STEMI patients (n = 101, mean age 64 ± 13 years; 69% male) treated with percutaneous revascularisation were recruited within 24 h post-infarction. Peripheral blood monocyte subpopulations were enumerated and characterised using flow cytometry after staining for CD14, CD16 and CCR2. Phenotypically, monocyte subpopulations are defined as: CD14++CD16-CCR2+ (Mon1), CD14++CD16+CCR2+ (Mon2) and CD14+CD16++CCR2- (Mon3). Phagocytic activity of monocytes was measured using flow cytometry and Ecoli commercial kit. Transthoracic 2D echocardiography was performed within 7 days and at 6 months post infarct to assess global longitudinal strain (GLS) via speckle tracking. MACE was defined as recurrent acute coronary syndrome and death. Results - STEMI patients with EF ≥50% by Simpson’s biplane (n = 52) had GLS assessed. Using multivariate regression analysis higher counts of Mon1 and Mon 2 and phagocytic activity of Mon2 were significantly associated with GLS (after adjusting for age, time to hospital presentation, and peak troponin levels) (Table 1). At 6 months, the convalescent GLS remained associated with higher counts of Mon1, Mon 2. At one year follow up, using multivariate Cox regression analysis, Mon1 and Mon2 counts were an independent predictor of MACE in patients with a reduced GLS (n = 21)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Blurred edges appear sharper in motion than when they are stationary. We (Vision Research 38 (1998) 2108) have previously shown how such distortions in perceived edge blur may be accounted for by a model which assumes that luminance contrast is encoded by a local contrast transducer whose response becomes progressively more compressive as speed increases. If the form of the transducer is fixed (independent of contrast) for a given speed, then a strong prediction of the model is that motion sharpening should increase with increasing contrast. We measured the sharpening of periodic patterns over a large range of contrasts, blur widths and speeds. The results indicate that whilst sharpening increases with speed it is practically invariant with contrast. The contrast invariance of motion sharpening is not explained by an early, static compressive non-linearity alone. However, several alternative explanations are also inconsistent with these results. We show that if a dynamic contrast gain control precedes the static non-linear transducer then motion sharpening, its speed dependence, and its invariance with contrast, can be predicted with reasonable accuracy. © 2003 Elsevier Science Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The work described in this thesis has been concerned with exploring the potential uses of ultrasound in Nuclear Magnetic Resonance (NMR) spectroscopy, The NMR spectra of liquids provide detailed structural information that may be deduced from the chemical shifts and spin-spin coupling, that are evident in the narrow resonances, arising from some of the nuclear broadening interactions being reduced to zero. In the solid state, all of the nuclear broadening interactions are present and broad lines in the NMR spectrum are observed. Current techniques employed to reduce the line widths in solids are based on coherent averaging techniques such as MAS NMR1,2 which can remove first order interactions. Recently DOR3 and DAS4 have become available to remove higher order interactions. SINNMR (Sonically Induced Narrowing of the NMR spectra of solids) has been reported by Homer et al5 and developed by Homer and Howard6 to reduce the line widths of solids. The basis of their work is the proposal that a colloidal suspension of solid particles can be made to move like large molecules by using ultrasonic agitation. The advantage of the technique is that the particles move incoherently removing all of the nuclear interactions responsible for broad lines. This thesis describes work on the extension of SINNMR by showing that the line width of 27AI and 11B for the glass Na20/B203/AI203 can be reduced by placing solid particles in a colloidal suspension. Further line width reduction is possible by applying ultrasound, at 2 MHz, of sufficient intensity. It is proposed that a cavitation field is responsible for imparting sufficient rotational motion to the solid particles to partially average the nuclear interactions responsible for broad lines. Rapid stirring of the colloidal suspension generates turbulent flow, however, the motion is insufficient to narrow the line widths for 27AI in the glass. Investigations of sonochemical reactions for in situ rate measurements by NMR have been made. 8y using the Weissler reaction7, it has been shown that ultrasonic cavitation is possible up to 10MHz. Preliminary studies have been carried out into the rate of ultrasonic polymerisation of methylmethacrylate by NMR. Long range order in liquid crystals can imposed when they are aligned in the presence a magnetic field. The degree of alignment can be monitored by NMR using, for example a deuterated solute added to the liquid crystal8. Ultrasonic streaming can then be employed to deflect the directors of the liquid crystal from their equilibrium position, resulting in a change In the NMR spectrum. The angle of deflection has been found for the thermotropic liquid crystal (I35) to be ca, 35° and for the lyotropic (ZLI-1167) to be ca, 20°, Mechanical stirring can used to re- orientate the liquid crystal but was found to give a smaller deflection, In a separate study, that did not use ultrasound, it has been found that the signal to noise ratio of 13C NMR signals can be enhanced by rapidly stirring a Iiquid. Accelerating the diffusion of nuclei out of the coil region enables M0 to be re-established more rapidly than the normal relaxation process. This allows the pulse repetition rate to be reduced without saturating the spin system. The influence of varying the relaxation delay, acquisition time and inter-pulse delay have been studied and parameters optimised. By studying cholesterol the technique was found to be most effective for nuclei with long relaxation times, such as quaternary carbon sites. Key Worde: NMR, Ulf.rasciund, 1,.lqi.fi!:l cryllltalt!h SCll1C1otlemlstryl I!r1hano~d algnflllf

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We sought to determine the extent to which red–green, colour–opponent mechanisms in the human visual system play a role in the perception of drifting luminance–modulated targets. Contrast sensitivity for the directional discrimination of drifting luminance–modulated (yellow–black) test sinusoids was measured following adaptation to isoluminant red–green sinusoids drifting in either the same or opposite direction. When the test and adapt stimuli drifted in the same direction, large sensitivity losses were evident at all test temporal frequencies employed (1–16 Hz). The magnitude of the loss was independent of temporal frequency. When adapt and test stimuli drifted in opposing directions, large sensitivity losses were evident at lower temporal frequencies (1–4 Hz) and declined with increasing temporal frequency. Control studies showed that this temporal–frequency–dependent effect could not reflect the activity of achromatic units. Our results provide evidence that chromatic mechanisms contribute to the perception of luminance–modulated motion targets drifting at speeds of up to at least 32°s-1. We argue that such mechanisms most probably lie within a parvocellular–dominated cortical visual pathway, sensitive to both chromatic and luminance modulation, but only weakly selective for the direction of stimulus motion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Blurred edges appear sharper in motion than when they are stationary. We proposed a model of this motion sharpening that invokes a local, nonlinear contrast transducer function (Hammett et al, 1998 Vision Research 38 2099-2108). Response saturation in the transducer compresses or 'clips' the input spatial waveform, rendering the edges as sharper. To explain the increasing distortion of drifting edges at higher speeds, the degree of nonlinearity must increase with speed or temporal frequency. A dynamic contrast gain control before the transducer can account for both the speed dependence and approximate contrast invariance of motion sharpening (Hammett et al, 2003 Vision Research, in press). We show here that this model also predicts perceived sharpening of briefly flashed and flickering edges, and we show that the model can account fairly well for experimental data from all three modes of presentation (motion, flash, and flicker). At moderate durations and lower temporal frequencies the gain control attenuates the input signal, thus protecting it from later compression by the transducer. The gain control is somewhat sluggish, and so it suffers both a slow onset, and loss of power at high temporal frequencies. Consequently, brief presentations and high temporal frequencies of drift and flicker are less protected from distortion, and show greater perceptual sharpening.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is widely supposed that things tend to look blurred when they are moving fast. Previous work has shown that this is true for sharp edges but, paradoxically, blurred edges look sharper when they are moving than when stationary. This is 'motion sharpening'. We show that blurred edges also look up to 50% sharper when they are presented briefly (8-24 ms) than at longer durations (100-500 ms) without motion. This argues strongly against high-level models of sharpening based specifically on compensation for motion blur. It also argues against a recent, low-level, linear filter model that requires motion to produce sharpening. No linear filter model can explain our finding that sharpening was similar for sinusoidal and non-sinusoidal gratings, since linear filters can never distort sine waves. We also conclude that the idea of a 'default' assumption of sharpness is not supported by experimental evidence. A possible source of sharpening is a nonlinearity in the contrast response of early visual mechanisms to fast or transient temporal changes, perhaps based on the magnocellular (M-cell) pathway. Our finding that sharpening is not diminished at low contrast sets strong constraints on the nature of the nonlinearity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We assessed summation of contrast across eyes and area at detection threshold ( C t). Stimuli were sine-wave gratings (2.5 c/deg) spatially modulated by cosine- and anticosine-phase raised plaids (0.5 c/deg components oriented at ±45°). When presented dichoptically the signal regions were interdigitated across eyes but produced a smooth continuous grating following their linear binocular sum. The average summation ratio ( C t1/([ C t1+2]) for this stimulus pair was 1.64 (4.3 dB). This was only slightly less than the binocular summation found for the same patch type presented to both eyes, and the area summation found for the two different patch types presented to the same eye. We considered 192 model architectures containing each of the following four elements in all possible orders: (i) linear summation or a MAX operator across eyes, (ii) linear summation or a MAX operator across area, (iii) linear or accelerating contrast transduction, and (iv) additive Gaussian, stochastic noise. Formal equivalences reduced this to 62 different models. The most successful four-element model was: linear summation across eyes followed by nonlinear contrast transduction, linear summation across area, and late noise. Model performance was enhanced when additional nonlinearities were placed before binocular summation and after area summation. The implications for models of probability summation and uncertainty are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of the research carried out in this report was to observe the first ever in-situ sonochemical reaction in the NMR Spectrometer in the megahertz region of ultrasound. Several reactions were investigated as potential systems for a sonochemical reaction followed by NMR spectroscopy. The primary problem to resolve when applying ultrasound to a chemical reaction is that of heating. Ultrasound causes the liquid to move and produces 'hot spots' resulting in an increase in sample temperature. The problem was confronted by producing a device that would counteract this effect and so remove the need to account for heating. However, the design of the device limited the length of time during which it would function. Longer reaction times were required to enable observations to be carried out in the NMR spectrometer. The fIrst and most obvious reactions attempted were those of the well-known ultrasonic dosimeter. Such a reaction would, theoretically, enable the author to simultaneously observe a reaction and determine the exact power entering the system for direct comparison of results. Unfortunately, in order to monitor the reactions in the NMR spectrometer the reactant concentrations had to be signifIcantly increased, which resulted in a notable increase in reaction time, making the experiment too lengthy to follow in the time allocated. The Diels-Alder Reaction is probably one of the most highly investigated reaction systems in the field of chemistry and it was this to which the author turned her attention. Previous authors have carried out ultrasonic investigations, with considerable success, for the reaction of anthracene with maleic anhydride. It was this reaction in particular that was next attempted. The first ever sonochemically enhanced reaction using a frequency of ultrasound in the megahertz (MHz) region was successfully carried out as bench experiments. Due to the complexity of the component reactants the product would precipitate from the solution and because the reaction could only be monitored by its formation, it was not possible to observe the reaction in the NMR spectrometer. The solvolysis of 2-chloro-2-methylpropane was examined in various solvent systems; the most suitable of which was determined to be aqueous 2-methylpropan-2-ol. The experiment was successfully enhanced by the application of ultrasound and monitored in-situ in the NMR spectrometer. The increase in product formation of an ultrasonic reaction over that of a traditional thermal reaction occurred. A range of 1.4 to 2.9 fold improvement was noted, dependent upon the reaction conditions investigated. An investigation into the effect of sonication upon a large biological molecule, in this case aqueous lysozyme, was carried out. An easily observed effect upon the sample was noted but no explanation for the observed effects could be established.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The work described in this thesis is directed to the examination of the hypothesis that ultrasound may be used to perturb molecular motion in the liquid phase. These changes can then be detected by nuclear magnetic resonance (NMR) in spin-lattice and spin-spin relaxation times. The objective being to develop a method capable of reducing the pulsed NMR acquisition times of slowly relaxing nuclei. The thesis describes the theoretical principles underlying both NMR spectroscopy and ultrasonics with particular attention being paid to factors that impinge on testing the above hypothesis. Apparatus has been constructed to enable ultrasound at frequencies between 1 and 10 mega-hertz with a variable power up to 100W/cm-2 to be introduced in the NMR sample. A broadband high frequency generator is used to drive PZT piezo-electric transducer via various transducer to liquid coupling arrangements. A commercial instrument of 20 kilo-hertz has also been employed to test the above hypothesis and also to demonstrate the usefulness of ultrasound in sonochemistry. The latter objective being, detection of radical formation in monomer and polymer ultrasonic degradation. The principle features of the results obtained are: Ultrasonic perturbation of T1 is far smaller for pure liquids than is for mixtures. The effects appear to be greater on protons (1H) than on carbon-13 nuclei (13C) relaxation times. The observed effect of ultrasonics is not due to temperature changes in the sample. As the power applied to the transducer is progressively increased T1 decreases to a minimum and then increases. The T1's of the same nuclei in different functional groups are influenced to different extents by ultrasound. Studies of the 14N resonances from an equimolar mixture of N, N-dimethylformamide and deuterated chloroform with ultrasonic frequencies at 1.115, 6, 6.42 and 10 MHz show that as the frequency is increased the NMR signal to noise ratio decreases to zero at the Larmor frequency of 6.42 MHz and then again rises. This reveals the surprising indication that an effect corresponding to nuclear acoustic saturation in the liquid may be observable. Ultrasonic irradiation of acidified ammonium chloride solution at and around 6.42 MHz appears to cause distinctive changes in the proton-nitrogen J coupling resonance at 89.56 MHz. Ultrasonic irradiation of N, N-dimethylacetamide at 2 KHz using the lowest stable power revealed the onset of coalescence in the proton spectrum. The corresponding effect achieved by direct heating required a temperature rise of approximately 30oC. The effects of low frequency (20 KHz) on relaxation times appear to be nil. Detection of radical formation proved difficult but is still regarded as the principle route for monomer and polymer degradation. The initial hypothesis is considered proven with the results showing significant changes in the mega-hertz region and none at 20 KHz.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present thesis investigates targeted (locally and systemically) delivery of a novel group of inhibitors of enzyme transglutaminases (TGs). TGs are a widely distributed group of enzymes that catalyse the formation of isopeptide bonds between the y-carboxamide group of protein-bound glutamines and the a-amino group of protein-bound lysines or polyamines. The first group of the novel inhibitors tested were the tluorescently labelled inhibitors of Factor XIIIa (FXIIIa). These small, non-toxic inhibitors have the potential to prevent stabilisation of thrombi by FXIIIa and consequently increase the natural rate of thrombolysis, in addition it reduces staphylococcal colonisation of catheters by inhibiting their FXIIIa¬mediated cross-linking to blood clot proteins on the central venous catheter (CVCs) surface. The aim of this work was to incorporate the FXIIIa inhibitor either within coating of polyurethane (PU) catheters or to integrate it into silicone catheters, so as to reduce the incidence of thrombotic occlusion and associated bacterial infection in CVCs. The initial work focused on the incorporation of FXIIIa inhibitors within polymeric coatings of PU catheters. After defining the key characteristics desired for an effective polymeric-coating, polyvinylpyrrolidone (PVP), poly(lactic-co-glycolic acid) (PLGA) or their combination were studies as polymers of choice for coating of the catheters_ The coating was conducted by dip-coating method in a polymer solution containing the inhibitor. Upon incubation of the inhibitor-and polymer-coated strips in buffer, PVP was dissolved instantly, generating fast and significant drug release, whilst PLGA did not dissolve, yielding a slow and an insufficient amount of drug release. Nevertheless, the drug release profile was enhanced upon employing a blend solution of PVP and PLGA. The second part of the study was to incorporate the FXIIIa inhibitor into a silicone elastomer; results demonstrated that FXIIIa inhibitor can be incorporated and released from silicone by using citric acid (CA) and sodium bicarbonate (SB) as additives and the drug release rate can be controlled by the amount of incorporated additives in the silicone matrix. Furthermore, it was deemed that the inhibitor was still biologically active subsequent to being released from the silicone elastomer strips. Morphological analysis confirmed the formation of channels and cracks inside the specimens upon the addition of CA and SB. Nevertheless, the tensile strength, in addition to Young's modulus of silicone elastomer strips, decreased constantly with an increasing amount of amalgamated CA/ SB in the formulations. According to our results, incorporation of FXIIIa inhibitor into catheters and other medical implant devices could offer new perspectives in preventing bio-material associated infections and thrombosis. The use of tissue transglutaminase (T02) inhibitor for treating of liver fibrosis was also investigated. Liver fibrosis is characterized by increased synthesis and decreased degradation of the extracellular matrix (ECM). Transglutaminase-mediated covalent cross-linking is involved in the stabilization of ECM in human liver fibrosis. Thus, TG2 inhibitors may be used to counteract the decreased degradation of the ECM. The potential of a liposome based drug delivery system for site specific delivery of the fluorescent TG2 inhibitor into the liver was investigated; results indicated that the TG2 inhibitor can be successfully integrated into liposomes and delivered to the liver, therefore demonstrating that liposomes can be employed for site-specific delivery of TG2 inhibitors into the liver and TG2 inhibitor incorporating liposomes could offer a new approach in treating liver fibrosis and its end stage disease cirrhosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Parkinson’s disease (PD) is a common disorder of middle-aged and elderly people in which degeneration of the extrapyramidal motor system causes significant movement problems. In some patients, however, there are additional disturbances in sensory systems including loss of the sense of smell and auditory and/or visual problems. This article is a general overview of the visual problems likely to be encountered in PD. Changes in vision in PD may result from alterations in visual acuity, contrast sensitivity, colour discrimination, pupil reactivity, eye movements, motion perception, visual field sensitivity and visual processing speeds. Slower visual processing speeds can also lead to a decline in visual perception especially for rapidly changing visual stimuli. In addition, there may be disturbances of visuo-spatial orientation, facial recognition problems, and chronic visual hallucinations. Some of the treatments used in PD may also have adverse ocular reactions. The pattern electroretinogram (PERG) is useful in evaluating retinal dopamine mechanisms and in monitoring dopamine therapies in PD. If visual problems are present, they can have an important effect on the quality of life of the patient, which can be improved by accurate diagnosis and where possible, correction of such defects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The search by many investigators for a solution to the reading problems encountered by individuals with no central vision has been long and, to date, not very fruitful. Most textual manipulations, including font size, have led to only modest gains in reading speed. Previous work on spatial integrative properties of peripheral retina suggests that 'visual crowding' may be a major factor contributing to inefficient reading. Crowding refers to the fact that juxtaposed targets viewed eccentrically may be difficult to identify. The purpose of this study was to assess the combined effects of line spacing and word spacing on the ability of individuals with age-related macular degeneration (ARMD) to read short passages of text that were printed with either high (87.5%) or low contrast (17.5%) letters. Low contrast text was used to avoid potential ceiling effects and to mimic a possible reduction in letter contrast with light scatter from media opacities. For both low and high contrast text, the fastest reading speeds we measured were for passages of text with double line and double word spacing. In comparison with standard single spacing, double word/line spacing increased reading speed by approximately 26% with high contrast text (p < 0.001), and by 46% with low contrast text (p < 0.001). In addition, double line/word spacing more than halved the number of reading errors obtained with single spaced text. We compare our results with previous reading studies on ARMD patients, and conclude that crowding is detrimental to reading and that its effects can be reduced with enhanced text spacing. Spacing is particularly important when the contrast of the text is reduced, as may occur with intraocular light scatter or poor viewing conditions. We recommend that macular disease patients should employ double line spacing and double-character word spacing to maximize their reading efficiency. © 2013 Blackmore-Wright et al.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To compare corneal thickness measurements using Orbscan II (OII) and ultrasonic (US) pachymetry in normal and in keratoconic eyes. Setting: Eye Department, Heartlands and Solihull NHS Trust, Birmingham, United Kingdom. Methods: Central corneal thickness (CCT) was measured by means of OII and US pachymetry in 1 eye of 72 normal subjects and 36 keratoconus patients. The apical corneal thickness (ACT) in keratoconus patients was also evaluated using each method. The mean of the difference, standard deviation (SD), and 95% limits of agreement (LoA = mean ± 2 SD), with and without applying the default linear correction factor (LCF), were determined for each sample. The Student t test was used to identify significant differences between methods, and the correlation between methods was determined using the Pearson bivariate correlation. Bland-Altman analysis was performed to confirm that the results of the 2 instruments were clinically comparable. Results: In normal eyes, the mean difference (± 95% LoA) in CCT was 1.04 μm ± 68.52 (SD) (P>.05; r = 0.71) when the LCF was used and 46.73 ± 75.40 μm (P = .0001; r = 0.71) without the LCF. In keratoconus patients, the mean difference (± 95% LoA) in CCT between methods was 42.46 ± 66.56 μm (P<.0001: r = 0.85) with the LCF, and 2.51 ± 73.00 μm (P>.05: r = 0.85) without the LCF. The mean difference (± 95% LoA) in ACT for this group was 49.24 ± 60.88 μm (P<.0001: r = 0.89) with the LCF and 12.71 ± 68.14 μm (P = .0077; r = 0.89) when the LCF was not used. Conclusions: This study suggests that OII and US pachymetry provide similar readings for CCT in normal subjects when an LCF is used. In keratoconus patients, OII provides a valid clinical tool for the noninvasive assessment of CCT when the LCF is not applied. © 2004 ASCRS and ESCRS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For more than a century it has been known that the eye is not a perfect optical system, but rather a system that suffers from aberrations beyond conventional prescriptive descriptions of defocus and astigmatism. Whereas traditional refraction attempts to describe the error of the eye with only two parameters, namely sphere and cylinder, measurements of wavefront aberrations depict the optical error with many more parameters. What remains questionable is the impact these additional parameters have on visual function. Some authors have argued that higher-order aberrations have a considerable effect on visual function and in certain cases this effect is significant enough to induce amblyopia. This has been referred to as ‘higher-order aberration-associated amblyopia’. In such cases, correction of higher-order aberrations would not restore visual function. Others have reported that patients with binocular asymmetric aberrations display an associated unilateral decrease in visual acuity and, if the decline in acuity results from the aberrations alone, such subjects may have been erroneously diagnosed as amblyopes. In these cases, correction of higher-order aberrations would restore visual function. This refractive entity has been termed ‘aberropia’. In order to investigate these hypotheses, the distribution of higher-order aberrations in strabismic, anisometropic and idiopathic amblyopes, and in a group of visual normals, was analysed both before and after wavefront-guided laser refractive correction. The results show: (i) there is no significant asymmetry in higher-order aberrations between amblyopic and fixing eyes prior to laser refractive treatment; (ii) the mean magnitude of higher-order aberrations is similar within the amblyopic and visually normal populations; (iii) a significant improvement in visual acuity can be realised for adult amblyopic patients utilising wavefront-guided laser refractive surgery and a modest increase in contrast sensitivity was observed for the amblyopic eye of anisometropes following treatment (iv) an overall trend towards increased higher-order aberrations following wavefront-guided laser refractive treatment was observed for both visually normal and amblyopic eyes. In conclusion, while the data do not provide any direct evidence for the concepts of either ‘aberropia’ or ‘higher-order aberration-associated amblyopia’, it is clear that gains in visual acuity and contrast sensitivity may be realised following laser refractive treatment of the amblyopic adult eye. Possible mechanisms by which these gains are realised are discussed.