10 resultados para Meaning of life assessment

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To design and validate a vision-specific quality-of-life assessment tool to be used in a clinical setting to evaluate low-vision rehabilitation strategy and management. METHODS: Previous vision-related questionnaires were assessed by low-vision rehabilitation professionals and patients for relevance and coverage. The 74 items selected were pretested to ensure correct interpretation. One hundred and fifty patients with low vision completed the chosen questions on four occasions to allow the selection of the most appropriate items. The vision-specific quality of life of patients with low vision was compared with that of 70 age-matched and gender-matched patients with normal vision and before and after low-vision rehabilitation in 278 patients. RESULTS: Items that were unreliable, internally inconsistent, redundant, or not relevant were excluded, resulting in the 25-item Low Vision Quality-of-Life Questionnaire (LVQOL). Completion of the LVQOL results in a summed score between 0 (a low quality of life) and 125 (a high quality of life). The LVQOL has a high internal consistency (α = 0.88) and good reliability (0.72). The average LVQOL score for a population with low vision (60.9 ± 25.1) was significantly lower than the average score of those with normal vision (100.3 ± 20.8). Rehabilitation improved the LVQOL score of those with low vision by an average of 6.8 ± 15.6 (17%). CONCLUSIONS: The LVQOL was shown to be an internally consistent, reliable, and fast method for measuring the vision-specific quality of life of the visually impaired in a clinical setting. It is able to quantify the quality of life of those with low vision and is useful in determining the effects of low-vision rehabilitation. Copyright (C) 2000 Elsevier Science Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The MacDQoL is an individualised measure of the impact of macular degeneration (MD) on quality of life (QoL). There is preliminary evidence of its psychometric properties and sensitivity to severity of MD. The aim of this study was to carry out further psychometric evaluation with a larger sample and investigate the measure's sensitivity to MD severity. Methods: Patients with MD (n = 156: 99 women, 57 men, mean age 79 ± 13 years), recruited from eye clinics (one NHS, one private) completed the MacDQoL by telephone interview and later underwent a clinic vision assessment including near and distance visual acuity (VA), comfortable near VA, contrast sensitivity, colour recognition, recovery from glare and presence or absence of distortion or scotoma in the central 10° of the visual field. Results: The completion rate for the MacDQoL items was 99.8%. Of the 26 items, three were dropped from the measure due to redundancy. A fourth was retained in the questionnaire but excluded when computing the scale score. Principal components analysis and Cronbach's alpha (0.944) supported combining the remaining 22 items in a single scale. Lower MacDQoL scores, indicating more negative impact of MD on QoL, were associated with poorer distance VA (better eye r = -0.431 p < 0.001; worse eye r = -0.350 p < 0.001; binocular vision r = -0.419 p < 0.001) and near VA (better eye r -0.326 p < 0.001; worse eye r = -0.226 p < 0.001; binocular vision r = -0.326 p < 0.001). Poorer MacDQoL scores were associated with poorer contrast sensitivity (better eye r = 0.392 p < 0.001; binocular vision r = 0.423 p < 0.001), poorer colour recognition (r = 0.417 p < 0.001) and poorer comfortable near VA (r = -0.283, p < 0.001). The MacDQoL differentiated between those with and without binocular scotoma (U = 1244 p < 0.001). Conclusion: The MacDQoL 22-item scale has excellent internal consistency reliability and a single-factor structure. The measure is acceptable to respondents and the generic QoL item, MD-specific QoL item and average weighted impact score are related to several measures of vision. The MacDQoL demonstrates that MD has considerable negative impact on many aspects of QoL, particularly independence, leisure activities, dealing with personal affairs and mobility. The measure may be valuable for use in clinical trials and routine clinical care. © 2005 Mitchell et al; licensee BioMed Central Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To determine the objective measures of visual function that are most relevant to subjective quality of vision and perceived reading ability in patients with acquired macular disease. METHODS: Twenty-eight patients with macular disease underwent a comprehensive assessment of visual function. The patients also completed a vision-related quality-of-life questionnaire that included a section of general questions about perceived visual performance and a section with specific questions on reading. RESULTS: Results of all tests of vision correlated highly with reported vision-related quality-of-life impairment. Low-contrast tests explained most of the variance in self-reported problems with reading. Text-reading speed correlated highly with overall concern about vision. CONCLUSIONS: Reading performance is strongly associated with vision-related quality of life. High-contrast distance acuity is not the only relevant measure of visual function in relation to the perceived visual performance of a patient with macular disease. The results suggest the importance of print contrast, even over print size, in reading performance in patients with acquired macular disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To investigate the MacDQoL test-retest reliability and sensitivity to change in vision over a period of one year in a sample of patients with age-related macular degeneration (AMD). DESIGN: A prospective, observational study. METHOD: Patients with AMD from an ophthalmologist's list (n = 135) completed the MacDQoL questionnaire by telephone interview and underwent a vision assessment on two occasions, one year apart. RESULTS: Among participants whose vision was stable over one year (n = 87), MacDQoL scores at baseline and follow-up were highly correlated (r = 0.95; P < .0001). Twelve of the 22 scale items had intraclass correlations of >.80; only two were correlated <.7. There was no difference between baseline and follow-up scores (P = .85), indicating excellent test-retest reliability. Poorer quality of life (QoL) at follow-up, measured by the MacDQoL present QoL overview item, was associated with deterioration in both the better eye and binocular distance visual acuity [VA] (r = 0.29; P = .001, r = 0.21; P = .016, respectively; n = 135). There was a positive correlation between deterioration in the Mac. DQoL average weighted impact score and deterioration in both binocular near VA and reading speed (r = 0.20; P = .019, r = 0.18; P = .041, respectively; n = 135). CONCLUSION: The MacDQoL has excellent test-retest reliability. Its sensitivity to change in vision status was demonstrated in correlational analyses. The measure indicates that the negative impact of AMD on QoL increases with increasing severity of visual impairment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The use of quality of life (QoL) instruments in menorrhagia research is increasing but there is concern that not enough emphasis is placed on patient-focus in these measurements, i.e. on issues which are of importance to patients and reflect their experiences and concerns (clinical face validity). The objective was to assess the quality of QoL instruments in studies of menorrhagia. STUDY DESIGN: A systematic review of published research. Papers were identified through MEDLINE (1966-April 2000), EMBASE (1980-April 2000), Science Citation Index (1981-April 2000), Social Science Citation Index (1981-April 2000), CINAHL (1982-1999) and PsychLIT (1966-1999), and by manual searching of bibliographies of known primary and review articles. Studies were selected if they assessed women with menorrhagia for life quality, either developing QoL instruments or applying them as an outcome measure. Selected studies were assessed for quality of their QoL instruments, using a 17 items checklist including 10 items for clinical face validity (issues of relevance to patients' expectations and concerns) and 7 items for measurement properties (such as reliability, responsiveness, etc.). RESULTS: A total of 19 articles, 8 on instrument development and 11 on application, were included in the review. The generic Short Form 36 Health Survey Questionnaire (SF36) was used in 12/19 (63%) studies. Only two studies developed new specific QoL instruments for menorrhagia but they complied with 7/17 (41%) and 10/17 (59%) of the quality criteria. Quality assessment showed that only 7/19 (37%) studies complied with more than half the criteria for face validity whereas 17/19 (90%) studies complied with more than half of the criteria for measurement properties (P = 0.0001). CONCLUSION: Among existing QoL instruments, there is good compliance with the quality criteria for measurement properties but not with those for clinical face validity. There is a need to develop methodologically sound disease specific QoL instruments in menorrhagia focussing both on face validity and measurement properties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Gilles de la Tourette syndrome (GTS) is a chronic childhood-onset neuropsychiatric disorder with a significant impact on patients' health-related quality of life (HR-QOL). Cavanna et al. (Neurology 2008; 71: 1410-1416) developed and validated the first disease-specific HR-QOL assessment tool for adults with GTS (Gilles de la Tourette Syndrome-Quality of Life Scale, GTS-QOL). This paper presents the translation, adaptation and validation of the GTS-QOL for young Italian patients with GTS. METHODS: A three-stage process involving 75 patients with GTS recruited through three Departments of Child and Adolescent Neuropsychiatry in Italy led to the development of a 27-item instrument (Gilles de la Tourette Syndrome-Quality of Life Scale in children and adolescents, C&A-GTS-QOL) for the assessment of HR-QOL through a clinician-rated interview for 6-12 year-olds and a self-report questionnaire for 13-18 year-olds. RESULTS: The C&A-GTS-QOL demonstrated satisfactory scaling assumptions and acceptability. Internal consistency reliability was high (Cronbach's alpha > 0.7) and validity was supported by interscale correlations (range 0.4-0.7), principal-component factor analysis and correlations with other rating scales and clinical variables. CONCLUSIONS: The present version of the C&A-GTS-QOL is the first disease-specific HR-QOL tool for Italian young patients with GTS, satisfying criteria for acceptability, reliability and validity. © 2013 - IOS Press and the authors. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Menorrhagia, or heavy menstrual bleeding (HMB), is a common gynaecological condition. As the aim of treatment is to improve women's wellbeing and quality of life (QoL), it is necessary to have effective ways to measure this. This study investigated the reliability and validity of the menorrhagia multi-attribute scale (MMAS), a menorrhagia-specific QoL instrument. Participants (n = 431) completed the MMAS and a battery of other tests as part of the baseline assessment of the ECLIPSE (Effectiveness and Cost-effectiveness of Levonorgestrel-containing Intrauterine system in Primary care against Standard trEatment for menorrhagia) trial. Analyses of their responses suggest that the MMAS has good measurement properties and is therefore an appropriate condition-specific instrument to measure the outcome of treatment for HMB. © 2011 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2011 RCOG.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The use of quality of life (QoL) instruments in menorrhagia research is increasing but there is concern that not enough emphasis is placed on patient-focus in these measurements, i.e. on issues which are of importance to patients and reflect their experiences and concerns (clinical face validity). The objective was to assess the quality of QoL instruments in studies of menorrhagia. STUDY DESIGN: A systematic review of published research. Papers were identified through MEDLINE (1966-April 2000), EMBASE (1980-April 2000), Science Citation Index (1981-April 2000), Social Science Citation Index (1981-April 2000), CINAHL (1982-1999) and PsychLIT (1966-1999), and by manual searching of bibliographies of known primary and review articles. Studies were selected if they assessed women with menorrhagia for life quality, either developing QoL instruments or applying them as an outcome measure. Selected studies were assessed for quality of their QoL instruments, using a 17 items checklist including 10 items for clinical face validity (issues of relevance to patients' expectations and concerns) and 7 items for measurement properties (such as reliability, responsiveness, etc.). RESULTS: A total of 19 articles, 8 on instrument development and 11 on application, were included in the review. The generic Short Form 36 Health Survey Questionnaire (SF36) was used in 12/19 (63%) studies. Only two studies developed new specific QoL instruments for menorrhagia but they complied with 7/17 (41%) and 10/17 (59%) of the quality criteria. Quality assessment showed that only 7/19 (37%) studies complied with more than half the criteria for face validity whereas 17/19 (90%) studies complied with more than half of the criteria for measurement properties (P = 0.0001). CONCLUSION: Among existing QoL instruments, there is good compliance with the quality criteria for measurement properties but not with those for clinical face validity. There is a need to develop methodologically sound disease specific QoL instruments in menorrhagia focussing both on face validity and measurement properties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background/Aims: To develop and assess the psychometric validity of a Chinese language Vision Health related quality-of-life (VRQoL) measurement instrument for the Chinese visually impaired. Methods: The Low Vision Quality of Life Questionnaire (LVQOL) was translated and adapted into the Chinese-version Low Vision Quality of Life Questionnaire (CLVQOL). The CLVQOL was completed by 100 randomly selected people with low vision (primary group) and 100 people with normal vision (control group). Ninety-four participants from the primary group completed the CLVQOL a second time 2 weeks later (test-retest group). The internal consistency reliability, test-retest reliability, item-internal consistency, item-discrimination validity, construct validity and discriminatory power of the CLVQOL were calculated. Results: The review committee agreed that the CLVQOL replicated the meaning of the LVQOL and was sensitive to cultural differences. The Cronbach's α coefficient and the split-half coefficient for the four scales and total CLVQOL scales were 0.75-0.97. The test-retest reliability as estimated by the intraclass correlations coefficient was 0.69-0.95. Item-internal consistency was >0.4 and item-discrimination validity was generally <0.40. The Varimax rotation factor analysis of the CLVQOL identified four principal factors. the quality-of-life rating of four subscales and the total score of the CLVQOL of the primary group were lower than those of the Control group, both in hospital-based subjects and community-based subjects. Conclusion: The CLVQOL Chinese is a culturally specific vision-related quality-of-life measure instrument. It satisfies conventional psychometric criteria, discriminates visually healthy populations from low vision patients and may be valuable in screening the local community as well as for use in clinical practice or research. © Springer 2005.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The impact of different levels of depression severity on quality of life (QoL) is not well studied, particularly regarding ICD-10 criteria. The ICD classification of depressive episodes in three levels of severity is also controversial and the less severe category, mild, has been considered as unnecessary and not clearly distinguishable from non-clinical states. The present work aimed to test the relationship between depression severity according to ICD-10 criteria and several dimensions of functioning as assessed by Medical Outcome Study (MOS) 36-item Short Form general health survey (SF-36) at the population level. METHOD: A sample of 551 participants from the second phase of the Outcome of Depression International Network (ODIN) study (228 controls without depression and 313 persons fulfilling ICD criteria for depressive episode) was selected for a further assessment of several variables, including QoL related to physical and mental health as measured with the SF-36. RESULTS: Statistically significant differences between controls and the depression group were found in both physical and mental markers of health, regardless of the level of depression severity; however, there were very few differences in QoL between levels of depression as defined by ICD-10. Regardless of the presence of depression, disability, widowed status, being a woman and older age were associated with worse QoL in a structural equation analysis with covariates. Likewise, there were no differences according to the type of depression (single-episode versus recurrent). CONCLUSIONS: These results cast doubt on the adequacy of the current ICD classification of depression in three levels of severity.