14 resultados para Catheter-related bacteremia

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microbiological diagnosis of catheter-related bloodstream infection (CR-BSI) is often based on isolation of indistinguishable micro-organisms from an explanted catheter tip and blood culture, confirmed by antibiograms. Whether phenotypic identification of coagulase-negative staphylococci (CoNS) allows an accurate diagnosis of CR-BSI to be established was evaluated. Eight patients with a diagnosis of CR-BSI had CoNS isolated from pure blood cultures and explanted catheter tips which were considered as indistinguishable strains by routine microbiological methods. For each patient, an additional three colonies of CoNS isolated from the blood and five from the catheter tip were subcultured and further characterized by antibiogram profiles, analytical profile index (API) biotyping and PFGE. PFGE distinguished more strains of CoNS compared to API biotyping or antibiograms (17, 10 and 11, respectively). By PFGE, indistinguishable micro-organisms were only isolated from pure blood and catheter tip cultures in four out of eight (50%) patients thus supporting the diagnosis of CR-BSI. In another patient, indistinguishable micro-organisms were identified in both cultures; however, other strains of CoNS were also present. The remaining three patients had multiple strains of CoNS, none of which were indistinguishable in the tip and blood cultures, thus questioning the diagnosis of CR-BSI. Phenotypic characterization of CoNS lacked discriminatory power. Current routine methods of characterizing a limited number of pooled colonies may generate misleading results as multiple strains may be present in the cultures. Multiple colonies should be studied using a rapid genotypic characterization method to confirm or refute the diagnosis of CR-BSI. © 2007 SGM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sixty coagulase-negative staphylococcus (CNS) isolates were recovered from the blood cultures or peritoneal dialysate effluent of 43 patients on renal dialysis. The patients had either renal dialysis catheter-related sepsis (CRS) or continuous ambulatory peritoneal dialysis (CAPD)-associated peritonitis. Isolates were characterized by biotyping, and genotyped by pulsed-field gel electrophoresis (PFGE). Phenotypic properties of the strains were also investigated. Several genotypes were identified with no one specific strain of CNS being associated with CRS. However, closely related strains were isolated from several patients within the units studied, suggesting horizontal transfer of micro-organisms. Genotypic macro-restriction profiles did not concur with phenotypic profiles or biotypes, confirming that genotyping is required for epidemiological studies. All staphylococcal strains were investigated for the production of phenotypic characteristics. Significant differences were predominantly seen in the production of lipase, esterase and elastase in strains isolated from the renal patients with CRS and CAPD-associated peritonitis, compared with a non-septic control group. These phenotypic characteristics may therefore have a role in the maintenance of CRS in renal patients. © 2003 The Hospital Infection Society. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Central venous catheters have become an integral part of patient management however they are associated with many complications including infection. Despite efforts being made to reduce the incidence of such infect ions the problem continues to increase and has resource implications for the Health Service. Studies relating to the source of microorganisms causing CVC-associated infection, the cost of such infections and the efficacy of an antimicrobial catheter have been undertaken. Thirty patients who required a CVC as part of their medical management and underwent cardiac surgery had the distal tips of their catheters sampled whilst in situ. Sampling took place within 1 h of catheter placement. Bacteria were isolated from 16% of the catheter distal tips sampled in situ. The guidewires used to insert the devices were also contaminated (50%). When CVC were inserted via a protective sheath, avoiding contact with the skin. the incidence of microbial contamination was reduced. These findings suggest that despite rigorous skin disinfection and strict aseptic technique, viable microorganisms are impacted onto the distal tip of CVC during the insertion procedure. Needleless intravascular access devices have been introduced in order to reduce the incidence of need1estick injury. However, it was unclear whether such connectors would act as a portal of entry for microorganisms to CVC. The efficacy of these devices was investigated. Within the controlled laboratory environment it was demonstrated that needleless devices, when challenged with microorganisms, did not allow the passage of microbes when flu id was injected. This therefore suggested that the devices should not increase the risk of catheter colonisation. When used in clinical practice however microbial contamination of the needleless connectors was 55 % in comparison to the routinely used luer connectors (23%). The cost of infections associated with CVC was determined. Twenty patients catheterised with a CVC designed for long term use who were admitted to hospital with a presumptive diagnosis of catheter-related infection were studied. The treatment given specifically for this infection was costed. The mean cost of such an infection was £ 1781.81. Throughout the UK this may amount to £1.565.906 per annum. The cost of infections associated with CVC designed for short term use was estimated to be between 5 and 7 million pounds per annum in the UK. In an attempt to reduce both the incidence and cost of catheter- related infection antimicrobial CVC have been developed. The efficacy of a novel polyurethane CVC impregnated on both the internal and external catheter surface with the quaternary ammonium compound benzalkonium chloride was investigated. Eighty eight patients received an antimicrobial catheter and 78 patients a conventional polyurethane CVC. The anti-microbial CVC resulted in a reduction in microbial colonisation of the external and internal polymer surfaces as compared to the control device. The observed reduction in microbial colonisation with the anti-microbial CVC may decrease the likelihood of subsequent infection offering a useful approach to the prevention of catheter-related infections.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The potential source of CVC colonisation was assessed. Isolates of coagulase-negative staphylococci (CoNS) recovered from the skin and CVC components of 3 cardiothoracic surgery patients were characterised by pulsed-field gel electrophoresis (PFGE). The genetic heterogeneity of CoNS isolated from the skin was demonstrated and specific genotypes implicated in catheter colonisation. In addition, phenotypic and genotypic typing techniques were assessed for their ability to characterise strains of CoNS recovered from 33 patients who developed catheter-related bloodstream infection (CR-BSI) on a bone marrow transplant (BMT) unit and Siaphylococcus aureus recovered from 6 cardiothoracic surgery patients with surgical site infection (SSI) following median sternotomy. This epidemiological investigation revealed that common strains of CoNS and 51 aureus where not associated with infection in patients with CR-BSI or sternal SSI during the study period. Furthermore, there was no correlation between phenotypic and genotypic characterisation results. The variable expression of phenotypic traits within strains of staphylococci was evident whilst PFGE and randomly amplified polymorphic DNA (RAPD) were highly discriminatory for the molecular characterisation of S. aureus and CoNS. This was highlighted in 8 stem cell transplant (SCT) patients whereby it was demonstrated that routine identification and characterisation of CoNS by phenotypic techniques may not be adequate for the diagnosis of CR-BSI by current guidelines. The potential of the lipid S ELISA to facilitate the diagnosis of CR-BSI in 38 haematology/SCT patients and sternal SSI in 57 cardiothoracic surgery patients was also assessed. The ELISA proved to be a sensitive test for the rapid serodiagnosis of infection due to staphylococci in immunocompetent patients. The acridine orange leucocyte cytospin test (AOLC) was also evaluated for the rapid diagnosis of CR-BSI in 16 haematology/SCT patients with Hickman CVC in situ. Although the sensitivity of the test was low, it may provide a useful adjunct to conventional methods for the in situ sampling of catheters to predict and diagnose CR-BSI, preventing the unnecessary removal of CVC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present thesis investigates targeted (locally and systemically) delivery of a novel group of inhibitors of enzyme transglutaminases (TGs). TGs are a widely distributed group of enzymes that catalyse the formation of isopeptide bonds between the y-carboxamide group of protein-bound glutamines and the a-amino group of protein-bound lysines or polyamines. The first group of the novel inhibitors tested were the tluorescently labelled inhibitors of Factor XIIIa (FXIIIa). These small, non-toxic inhibitors have the potential to prevent stabilisation of thrombi by FXIIIa and consequently increase the natural rate of thrombolysis, in addition it reduces staphylococcal colonisation of catheters by inhibiting their FXIIIa¬mediated cross-linking to blood clot proteins on the central venous catheter (CVCs) surface. The aim of this work was to incorporate the FXIIIa inhibitor either within coating of polyurethane (PU) catheters or to integrate it into silicone catheters, so as to reduce the incidence of thrombotic occlusion and associated bacterial infection in CVCs. The initial work focused on the incorporation of FXIIIa inhibitors within polymeric coatings of PU catheters. After defining the key characteristics desired for an effective polymeric-coating, polyvinylpyrrolidone (PVP), poly(lactic-co-glycolic acid) (PLGA) or their combination were studies as polymers of choice for coating of the catheters_ The coating was conducted by dip-coating method in a polymer solution containing the inhibitor. Upon incubation of the inhibitor-and polymer-coated strips in buffer, PVP was dissolved instantly, generating fast and significant drug release, whilst PLGA did not dissolve, yielding a slow and an insufficient amount of drug release. Nevertheless, the drug release profile was enhanced upon employing a blend solution of PVP and PLGA. The second part of the study was to incorporate the FXIIIa inhibitor into a silicone elastomer; results demonstrated that FXIIIa inhibitor can be incorporated and released from silicone by using citric acid (CA) and sodium bicarbonate (SB) as additives and the drug release rate can be controlled by the amount of incorporated additives in the silicone matrix. Furthermore, it was deemed that the inhibitor was still biologically active subsequent to being released from the silicone elastomer strips. Morphological analysis confirmed the formation of channels and cracks inside the specimens upon the addition of CA and SB. Nevertheless, the tensile strength, in addition to Young's modulus of silicone elastomer strips, decreased constantly with an increasing amount of amalgamated CA/ SB in the formulations. According to our results, incorporation of FXIIIa inhibitor into catheters and other medical implant devices could offer new perspectives in preventing bio-material associated infections and thrombosis. The use of tissue transglutaminase (T02) inhibitor for treating of liver fibrosis was also investigated. Liver fibrosis is characterized by increased synthesis and decreased degradation of the extracellular matrix (ECM). Transglutaminase-mediated covalent cross-linking is involved in the stabilization of ECM in human liver fibrosis. Thus, TG2 inhibitors may be used to counteract the decreased degradation of the ECM. The potential of a liposome based drug delivery system for site specific delivery of the fluorescent TG2 inhibitor into the liver was investigated; results indicated that the TG2 inhibitor can be successfully integrated into liposomes and delivered to the liver, therefore demonstrating that liposomes can be employed for site-specific delivery of TG2 inhibitors into the liver and TG2 inhibitor incorporating liposomes could offer a new approach in treating liver fibrosis and its end stage disease cirrhosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: A rapid random amplification of polymorphic DNA (RAPD) technique was developed to distinguish between strains of coagulase-negative staphylococci (CoNS) involved in central venous catheter (CVC)-related bloodstream infection. Its performance was compared with that of pulsed-field gel electrophoresis (PFGE). Methods: Patients at the University Hospital Birmingham NHS Foundation Trust, U.K. who underwent stem cell transplantation and were diagnosed with CVC-related bloodstream infection due to CoNS whilst on the bone marrow transplant unit were studied. Isolates of CoNS were genotyped by PFGE and RAPD, the latter employing a single primer and a simple DNA extraction method. Results: Both RAPD and PFGE were highly discriminatory (Simpson's diversity index, 0.96 and 0.99, respectively). Within the 49 isolates obtained from blood cultures of 33 patients, 20 distinct strains were identified by PFGE and 25 by RAPD. Of the 25 strains identified by RAPD, nine clusters of CoNS contained isolates from multiple patients, suggesting limited nosocomial spread. However, there was no significant association between time of inpatient stay and infection due to any particular strain. Conclusion: The RAPD technique presented allows CoNS strains to be genotyped with high discrimination within 4 h, facilitating real-time epidemiological investigations. In this study, no single strain of CoNS was associated with a significant number of CVC-related bloodstream infections. © 2005 Published by Elsevier Ltd on behalf of the British Infection Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intravascular catheters are one of the main causes of bacteraemia and septicaemia in hospitalised patients and continue to be associated with a significant morbidity and mortality. Two main types of infections occur, they can be either localised at the catheter insertion site of systemic with a septicaemia. The clinical parameters related to these infections are presented. The laboratory diagnosis of these infections is also extensively reviewed and recommendations are made as to the most appropriate diagnostic method to be used. © 2005 The British Infection Society. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To develop and evaluate a rapid enzyme linked immunosorbent assay (ELISA) for the diagnosis of intravascular catheter related sepsis caused by coagulase negative staphylococci. Methods: Forty patients with a clinical and microbiological diagnosis of intravascular catheter related sepsis and positive blood cultures, caused by coagulase negative staphylococci, and 40 control patients requiring a central venous catheter as part of their clinical management were recruited into the study. Serum IgG responses to a previously undetected exocellular antigen produced by coagulase negative staphylococci, termed lipid S, were determined in the patient groups by a rapid ELISA. Results: There was a significant difference (p = < 0.0001) in serum IgG to lipid S between patients with catheter related sepsis and controls. The mean antibody titre in patients with sepsis caused by coagulase negative staphylococci was 10 429 (range, no detectable serum IgG antibody to 99 939), whereas serum IgG was not detected in the control group of patients. Conclusions: The rapid ELISA offers a simple, economical, and rapid diagnostic test for suspected intravascular catheter related sepsis caused by coagulase negative staphylococci, which can be difficult to diagnose clinically. This may facilitate treatment with appropriate antimicrobials and may help prevent the unnecessary removal of intravascular catheters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Letter to the Editor

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Gram-positive microorganisms, specifically coagulase-negative staphylococci are the most common species recovered from clinical culture specimens of patients with end-stage renal disease. The propensity of coagulase-negative staphylococci (CNS) to cause infection in this patient group has been widely debated. However, it is still unclear how this usually avirulent commensal microorganism produces infection that contributes to high rates of morbidity and mortality in patients with end-stage renal disease. The aim of this thesis was to investigate the rate, geographical distribution, molecular and phenotypic mechanisms of Gram-positive microorganisms associated with infection in renal dialysis patients. In addition, it sought to assess the value of early serological diagnosis of dialysis catheter-associated infection and the effect of antimicrobial treatment regimens on the faecal carriage of enteric microorganisms. In this study, the incidence of haemodialysis catheter-associated infection was established with the Meditrend audit tool. This tool was used to assess the infection outcomes of catheter insertion and management procedures until the catheter was explanted. Introduction of a catheter management protocol decreased the incidence of catheter-related infection. Staphylococcal species recovered from episodes of haemodialysis catheter-associated infection and continuous ambulatory peritoneal dialysis (CAPD)-associated peritonitis were genotyped by determination of macrorestriction profiles with pulsed-field gel electrophoresis. This highlighted horizontal transfer of microorganisms between different patients and the environment. The phenotypic characteristics of these strains were also investigated to determine characteristics that could be used as markers for dialysis catheter-associated infection. The expression of elastase, lipase and esterase by CNS was significantly associated with infection. A rapid enzyme-linked immunosorbent assay incorporating a novel staphylococcal antigen (lipid S) was used to evaluate the early detection of anti-staphylococcal immunoglobulin gamma in patient sera. The comparison of culture positive and culture negative patients demonstrated a steady state of immune activation in both groups. However anti-lipid S serum antibody titres > 1000 were found to be a predictor of infection. The effect on faecal carriage of vancomycin resistant enterococci (VRE) and Clostridium difficile toxins in patients treated with CAPD when empiric cephalosporin therapy was substituted for piperacillin/tazobactam was investigated. The introduction of piperacillin/tazobactam demonstrated a decrease in the faecal carriage of VRE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The coagulase-negative staphylococci are the most frequent cause of sepsis associated with indwelling intravascular catheters. Current microbiological investigations to support the diagnosis of catheter-related sepsis (CRS) include the culture of blood and catheter tips, however positive results may reflect specimen contamination, or colonisation of the catheter rather than true sepsis. Previous serological approaches to assist in the diagnosis of CRS based on cellular staphylococcal antigens have been of limited value. In this current study, the serodiagnostic potential of an exocellular antigen produced by 7 strains of coagulase-negative staphylococci cultured in brain heart infusion broth was investigated. Antigenic material isolated by gel permeation from liquid culture was characterised by immunological techniques and chemical analysis. Characterisation of the exocellular antigen revealed a novel glycerophosphoglycolipid, termed lipid S. which shared antigenic determinants with lipoteichoic acid, but differed by comprising a glycerophosphate chain length of only 6 units. In addition, lipid S was immunologically distinct from diphosphatidyl glycerol, a constituent cell membrane phospho lipid. An indirect enzyme linked immunosorbent assay (ELISA) based on lipid S was subsequently developed and used to determine serum antibody levels (IgM and IgG) in 67 patients with CRS due to staphylococci, and 67 patients with a central venous catheter (CVC) in situ who exhibited no evidence of sepsis. The sensitivity and specificity of the lipid S IgG ELISA was 75% and 90% respectively whilst the IgM assay had sensitivity and specificity of 52% and 85%. The addition of GullSORereagent to the EL1SA procedure to remove competing serum IgG and rheumatoid factor did not significantly improve the performance of the IgM assay. The serological response in serial serum samples of 13 patients with CRS due to staphylococci was investigated. Elevated levels of antibody were detected at an early stage of infection, prior to the isolation of microorganisms by standard culture methods, and before the clinical presentation of sepsis in 3 patients. The lipid S ELISA was later optimised and a rapid 4-hour assay developed for the serodiagnosis of CRS. Serum IgG levels were determined in 40 patients with CRS due to staphylococci and 40 patients with a CVC in situ who exhibited no evidence of sepsis. The sensitivity and specificity of the rapid IgG assay was 70% and 100% respectively. Elevated serum antibody levels in patients with endocarditis, prosthetic joint infection and pyogenic spondylodiscitis due to Gram-positive cocci were also detected with the lipid S ELISA suggesting that the assay may facilitate the diagnosis of these infections. Unexpected increased levels of anti-lipid S IgG in 31% of control patients with sciatica suggested a possible microbial aetiology of this condition. Further investigation of some of these patients by culture of microdiscectomy tissue removed at operation, revealed the presence of low-virulent microorganisms in 37% of patients of which Propionibacterium aeries accounted for 85% of the positive culture isolates. The results suggested a previously unrecognised association between P. acnes and sciatica, which may have implications for the future management of the condition.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The microbial contamination rate of luers of central venous catheters (CVCs) with either PosiFlow® needleless connectors or standard caps attached was investigated. The efficacy of 70% (v/v) isopropyl alcohol, 0.5% (w/v) chlorhexidine in gluconate 70% (v/v) isopropyl alcohol and 10% (w/v) aqueous povidone-iodine to disinfect the intravenous connections was also assessed. Seventy-seven patients undergoing cardiac surgery who required a CVC as part of their clinical management were randomly allocated either needleless connectors or standard caps. Patients were also designated to receive chlorhexidine/alcohol, isopropyl alcohol or povidone-iodine for pre-CVC insertion skin preparation and disinfection of the connections. After 72 h in situ the microbial contamination rate of 580 luers, 306 with standard caps and 274 with needleless connectors attached, was determined. The microbial contamination rate of the external compression seals of 274 needleless connectors was also assessed to compare the efficacy of the three disinfectants. The internal surfaces of 55 out of 306 (18%) luers with standard caps were contaminated with micro-organisms, whilst only 18 out of 274 (6.6%) luers with needleless connectors were contaminated (P<0.0001). Of those needleless connectors disinfected with isopropyl alcohol, 69.2% were externally contaminated with micro-organisms compared with 30.8% disinfected with chlorhexidine/alcohol (P<0.0001) and 41.6% with povidone-iodine (P<0.0001). These results suggest that the use of needleless connectors may reduce the microbial contamination rate of CVC luers compared with the standard cap. Furthermore, disinfection of needleless connectors with either chlorhexidine/alcohol or povidone-iodine significantly reduced external microbial contamination. Both these strategies may reduce the risk of catheter-related infections acquired via the intraluminal route. © 2003 The Hospital Infection Society. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Needleless connectors are being increasingly used for direct access to intravascular catheters. However, the potential for microbial contamination of these devices and subsequent infection risk is still widely debated. In this study the microbial contamination rate associated with three-way stopcock luers with standard caps attached was compared to those with Y-type extension set luers with Clearlink® needleless connectors attached. Fifty patients undergoing cardiothoracic surgery who required a central venous catheter (CVC) as part of their peri- and postoperative management were studied for microbial contamination of CVC luers following 72 hrs in situ. Each patient's CVC was randomly designated to have either the three-way stopcocks with caps (control patients) or Clearlink® Y-type extension sets (test patients). Prior to, and following each manipulation of the three-way stopcock luers or Clearlink® devices, a 70% (v/v) isopropyl alcohol swab was used for disinfection of the connections. The microbial contamination of 393 luers, 200 with standard caps and 193 with Clearlink® attached, was determined. The internal surfaces of 20 of 200 (10%) three-way stopcock luers with standard caps were contaminated with micro-organisms whereas only one of 193 (0.5%) luers with Clearlink® attached was contaminated (P < 0.0001). These results demonstrate that the use of the Clearlink® device with a dedicated disinfection regimen reduces the internal microbial contamination rate of CVC luers compared with standard caps. The use of such needle-free devices may therefore reduce the intraluminal risk of catheter-related bloodstream infection and thereby supplement current preventive guidelines. © 2006 The Hospital Infection Society.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Central venous catheters (CVCs) are being utilized with increasing frequency in intensive care and general medical wards. In spite of the extensive experience gained in their application, CVCs are related to the long-term risks of catheter sheath formation, infection, and thrombosis (of the catheter or vessel itself) during catheterization. Such CVC-related-complications are associated with increased morbidity, mortality, duration of hospitalization, and medical care cost [1]. The present study incorporates a novel group of Factor XIIIa (FXIIIa, plasma transglutaminase) inhibitors into a lubricious silicone elastomer in order to generate an optimized drug delivery system whereby a secondary sustained drug release profile occurs following an initial burst release for catheters and other medical devices. We propose that the incorporation of FXIIIa inhibitors into catheters, stents, and other medical implant devices would reduce the incidence of catheter sheath formation, thrombotic occlusion, and associated staphylococcal infection. This technique could be used as a local delivery system for extended release with an immediate onset of action for other poorly aqueous soluble compounds. © 2012 Elsevier B.V. All rights reserved.