48 resultados para high-index


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A low cost interrogation scheme is demonstrated for a refractometer based on an in-line fiber long period grating (LPG) Mach–Zehnder interferometer. Using this interrogation scheme the minimum detectable change in refractive index of ?n ~ 1.8×10-6 is obtained, which is the highest resolution achieved using a fiber LPG device, and is comparable to precision techniques used in the industry including high performance liquid chromatography and ultraviolet spectroscopy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fabrication and characterization of long-period gratings (LPGs) in fiber tapers is presented alongside supporting theory. The devices possess a high sensitivity to the index of aqueous solutions due to an observed spectral bifurcation effect, yielding a limiting index resolution of ±8.5×10-5 for solutions with an index in the range 1.330-1.335.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new regime of waveguides consisting of aligned spheres of strongly changed refractive - index in fused silica are explored and their guiding properties are measured.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A series of surface plasmonic fibre devices were fabricated using multiple coatings deposited on a lapped section of a single mode fibre. Coupling from the guided mode to surface plasmons was promoted following UV laser irradiation of the coated region through a phase mask, which generated a surface relief grating structure. The devices showed high spectral sensitivities and strong coupling for low refractive indices as compared to other grating-type fibre devices. The plasmonic devices were used to detect the variation in the refractive indices of alkane gases with measured wavelength and coupling sensitivity to index of 3400 nm RIU-1 and 8300 dB RIU-1, respectively. As a demonstration of the performance of these gas sensors, a minimum concentration of 2% by volume of butane in ethane was achieved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Long-period fibre gratings (LPGs) have previously been used to detect quantities such as temperature, strain, and refractive index (RI). We report here, to the best of our knowledge, the first investigation on refractive index sensing properties of LPGs with sol–gel derived titanium and silicon oxide coatings. It is revealed that the RI sensitivity of an LPG is affected by both the thickness and the index value of the coating; a coating with higher index and thickness will enhance the LPG RI sensitivity significantly. The surrounding refractive index induced LPG resonance shift has been evaluated over the LPGs' most sensitive RI region from 1.42 to 1.44. We have identified that, in this region, the uncoated LPG has an RI sensitivity of (-673.0 ± 0.4) nm/uri (unit of refractive index) while the LPG coated with titanium oxide exhibits a sensitivity as high as (-1067.15 ± 0.04) nm/uri. The experimental results also reveal that, even in the RI insensitive region around 1.33, there still is a marked enhancement in RI sensitivity of the sol–gel coated LPG compared to the uncoated one. This is potentially significant as coated LPGs may be extended to low RI gas and semi-liquidized based sensing applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A low-cost high-resolution wavelength-division-multiplexing (WDM) interrogation system operating around 800 nm region with operational bandwidth up to 60 nm and resolution of 12.7 pm utilizing a tilted fiber Bragg grating (TFBG) and a CCDarray detector has been implemented. The system has been evaluated for interrogating fiber Bragg grating based strain, temperature sensors, giving sensitivities of 0.59 pm/µe and 5.6 pm/°C, which are in good agreement with previously reported values. Furthermore, the system has been utilized to detect the refractive index change of sample liquids, demonstrating a capability of measuring index change as small as 10¯5. In addition, the vectorial expression of phase match condition and fabrication of TFBG have been discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have experimentally investigated the mode dispersion property and refractive index sensitivity of dual-peak long-period fiber gratings (LPGs) that were sensitized by hydrofluoric acid (HF) etching. The nature of the coupled cladding modes close to the dispersion turning point makes the dual-peak LPGs ultrasensitive to cladding property, permitting a fine tailoring of the mode dispersion and index sensitivity by the light cladding etching method using HF acid of only 1% concentration. As an implementation of an optical biosensor, the etched device was used to detect the concentration of hemoglobin protein in a sugar solution, showing a sensitivity as high as 20 nm/1%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A series of waveguides was inscribed in a borosilicate glass (BK7) by an 11 MHz repetition rate femtosecond laser operating with pulse energies from 16 to 30 nJ and focused at various depths within the bulk material. The index modification was measured using a quantitative phase microscopy technique that revealed central index changes ranging from 5×10-3 to 10-2, leading to waveguides that exhibited propagation losses of 0.2 dB/cm at a wavelength of 633 nm and 0.6 dB/cm at a wavelength of 1550 nm with efficient mode matching, less than 0.2 dB, to standard optical fibers. Analysis of the experimental data shows that, for a given inscription energy, the index modification has a strong dependence on inscription scanning velocity. At higher energies, the index modification increases with increasing inscription scanning velocity with other fabrication parameters constant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report the implementation of a low-cost high-resolution WDM interrogation system operating around 800nm region with bandwidth up to 60 nm and resolution of 13 pm by utilising a tilted fibre Bragg grating as an out-coupling device and a CCD-array detector. The system has been evaluated for interrogating fibre Bragg grating based strain, temperature sensors, giving sensitivities of 0.6 pm/µe and 5.6 pm/°C which are in good agreement with previously reported values. Furthermore, the system has been utilised to detect refractive index change of sample liquids, demonstrating a capability of measuring index change as small as 10-5.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We propose the design of a novel ?-shaped fiber laser resonator and apply it to build a long-cavity normaldispersion mode-locked Er-fiber laser which features enhanced functionalities for management and optimization of pulsed lasing regimes. We report the generation of sub-nanosecond pulses with the energy of ~0.5 µJ at a kilohertz-scale repetition rate in an all-fiber system based on the new laser design. A combination of special design solutions in the laser, such as polarization instability compensation in the ultra-long arm of the resonator, intra-cavity spectral selection of radiation with a broadband fiber Bragg grating, and polarization selection by means of a tilted refractive index grating, ensures low amplified spontaneous emission (ASE) noise and high stability of the laser system output parameters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Point-probe optical fiber chem-sensors have been implemented using cladding etched fiber Bragg gratings. The sensors possess refractive index sensing capability that can be utilized to measure chemical concentrations. The Bragg wavelength shift reaches 8 nm when the index of surrounding medium changes from 1.33 to 1.44, giving maximum sensitivity more than 10 times higher than that of previously reported devices. More importantly, the dual-grating configuration of the point-probe sensors offers a temperature reference function, permitting accurate measurement of refractive index encoded chemical concentrations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We developed an alternative approach for measuring information and communication technology (ICT), applying Data Envelopment Analysis (DEA) using data from the International Telecommunications Union as a sample of 183 economies. We compared the ICT-Opportunity Index (ICT-OI) with our DEA-Opportunity Index (DEA-OI) and found a high correlation between the two. Our findings suggest that both indices are consistent in their measurement of digital opportunity, though differences still exist in different regions. Our new DEA-OI offers much more than the ICT-OI. Using our model, the target and peer groups for each country can be identified.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report the implementation of a low-cost high-resolution WDM interrogation system operating around 800nm region with bandwidth up to 60 nm and resolution of 13 pm by utilising a tilted fibre Bragg grating as an out-coupling device and a CCD-array detector. The system has been evaluated for interrogating fibre Bragg grating based strain, temperature sensors, giving sensitivities of 0.6 pm/µe and 5.6 pm/°C which are in good agreement with previously reported values. Furthermore, the system has been utilised to detect refractive index change of sample liquids, demonstrating a capability of measuring index change as small as 10-5.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently introduced surface nanoscale axial photonics (SNAP) makes it possible to fabricate high-Q-factor microresonators and other photonic microdevices by dramatically small deformation of the optical fiber surface. To become a practical and robust technology, the SNAP platform requires methods enabling reproducible modification of the optical fiber radius at nanoscale. In this Letter, we demonstrate superaccurate fabrication of high-Q-factor microresonators by nanoscale modification of the optical fiber radius and refractive index using CO laser and UV excimer laser beam exposures. The achieved fabrication accuracy is better than 2Å in variation of the effective fiber radius. © 2011 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Point-probe optical fiber chem-sensors have been implemented using cladding etched fiber Bragg gratings. The sensors possess refractive index sensing capability that can be utilized to measure chemical concentrations. The Bragg wavelength shift reaches 8 nm when the index of surrounding medium changes from 1.33 to 1.44, giving maximum sensitivity more than 10 times higher than that of previously reported devices. More importantly, the dual-grating configuration of the point-probe sensors offers a temperature reference function, permitting accurate measurement of refractive index encoded chemical concentrations.