7 resultados para time measurement
em DigitalCommons@The Texas Medical Center
Resumo:
A patient classification system was developed integrating a patient acuity instrument with a computerized nursing distribution method based on a linear programming model. The system was designed for real-time measurement of patient acuity (workload) and allocation of nursing personnel to optimize the utilization of resources.^ The acuity instrument was a prototype tool with eight categories of patients defined by patient severity and nursing intensity parameters. From this tool, the demand for nursing care was defined in patient points with one point equal to one hour of RN time. Validity and reliability of the instrument was determined as follows: (1) Content validity by a panel of expert nurses; (2) predictive validity through a paired t-test analysis of preshift and postshift categorization of patients; (3) initial reliability by a one month pilot of the instrument in a practice setting; and (4) interrater reliability by the Kappa statistic.^ The nursing distribution system was a linear programming model using a branch and bound technique for obtaining integer solutions. The objective function was to minimize the total number of nursing personnel used by optimally assigning the staff to meet the acuity needs of the units. A penalty weight was used as a coefficient of the objective function variables to define priorities for allocation of staff.^ The demand constraints were requirements to meet the total acuity points needed for each unit and to have a minimum number of RNs on each unit. Supply constraints were: (1) total availability of each type of staff and the value of that staff member (value was determined relative to that type of staff's ability to perform the job function of an RN (i.e., value for eight hours RN = 8 points, LVN = 6 points); (2) number of personnel available for floating between units.^ The capability of the model to assign staff quantitatively and qualitatively equal to the manual method was established by a thirty day comparison. Sensitivity testing demonstrated appropriate adjustment of the optimal solution to changes in penalty coefficients in the objective function and to acuity totals in the demand constraints.^ Further investigation of the model documented: correct adjustment of assignments in response to staff value changes; and cost minimization by an addition of a dollar coefficient to the objective function. ^
Resumo:
BACKGROUND: Few reports of the utilization of an accurate, cost-effective means for measuring HPV oncogene transcripts have been published. Several papers have reported the use of relative quantitation or more expensive Taqman methods. Here, we report a method of absolute quantitative real-time PCR utilizing SYBR-green fluorescence for the measurement of HPV E7 expression in cervical cytobrush specimens. RESULTS: The construction of a standard curve based on the serial dilution of an E7-containing plasmid was the key for being able to accurately compare measurements between cervical samples. The assay was highly reproducible with an overall coefficient of variation of 10.4%. CONCLUSION: The use of highly reproducible and accurate SYBR-based real-time polymerase chain reaction (PCR) assays instead of performing Taqman-type assays allows low-cost, high-throughput analysis of viral mRNA expression. The development of such assays will help in refining the current screening programs for HPV-related carcinomas.
Resumo:
DCE-MRI is an important technique in the study of small animal cancer models because its sensitivity to vascular changes opens the possibility of quantitative assessment of early therapeutic response. However, extraction of physiologically descriptive parameters from DCE-MRI data relies upon measurement of the vascular input function (VIF), which represents the contrast agent concentration time course in the blood plasma. This is difficult in small animal models due to artifacts associated with partial volume, inflow enhancement, and the limited temporal resolution achievable with MR imaging. In this work, the development of a suite of techniques for high temporal resolution, artifact resistant measurement of the VIF in mice is described. One obstacle in VIF measurement is inflow enhancement, which decreases the sensitivity of the MR signal to the presence of contrast agent. Because the traditional techniques used to suppress inflow enhancement degrade the achievable spatiotemporal resolution of the pulse sequence, improvements can be achieved by reducing the time required for the suppression. Thus, a novel RF pulse which provides spatial presaturation contemporaneously with the RF excitation was implemented and evaluated. This maximizes the achievable temporal resolution by removing the additional RF and gradient pulses typically required for suppression of inflow enhancement. A second challenge is achieving the temporal resolution required for accurate characterization of the VIF, which exceeds what can be achieved with conventional imaging techniques while maintaining adequate spatial resolution and tumor coverage. Thus, an anatomically constrained reconstruction strategy was developed that allows for sampling of the VIF at extremely high acceleration factors, permitting capture of the initial pass of the contrast agent in mice. Simulation, phantom, and in vivo validation of all components were performed. Finally, the two components were used to perform VIF measurement in the murine heart. An in vivo study of the VIF reproducibility was performed, and an improvement in the measured injection-to-injection variation was observed. This will lead to improvements in the reliability of quantitative DCE-MRI measurements and increase their sensitivity.
Resumo:
Purpose. The aim of this research was to evaluate the effect of enteral feeding on tonometric measurement of gastric regional carbon dioxide levels (PrCO2) in normal healthy volunteers. Design and methods. The sample included 12 healthy volunteers recruited by the University Clinical Research Center (UCRC). An air tonometry system monitored PrCO2 levels using a tonometer placed in the lumen of the stomach via orogastric intubation. PrCO2 was automatically measured and recorded every 10 minutes throughout the five hour study period. An oral dose of famotidine 40 mg was self-administered the evening prior to and the morning of the study. Instillation of Isocal® High Nitrogen (HN) was used for enteral feeding in hourly escalating doses of 0, 40, 60, and 80 ml/hr with no feeding during the fifth hour. Results . PrCO2 measurements at time 0 and 10 minutes (41.4 ± 6.5 and 41.8 ± 5.7, respectively) demonstrated biologic precision (Levene's Test statistic = 0.085, p-value 0.774). Biologic precision was lost between T130 and T140 40 when compared to baseline TO (Levene's Test statistic = 1.70, p-value 0.205; and 3.205, p-value 0.042, respectively) and returned to non-significant levels between T270 and T280 (Levene's Test statistic = 3.083, p-value 0.043; and 2.307, p-value 0.143, respectively). Isocal® HN significantly affected the biologic accuracy of PrCO2 measurements (repeated measures ANOVA F 4.91, p-value <0.001). After 20 minutes of enteral feeding at 40 ml/hr, PrCO2 significantly increased (41.4 ± 6.5 to 46.6 ± 4.25, F = 5.4, p-value 0.029). Maximum variance from baseline (41.4 ± 6.5 to 61.3 ± 15.2, F = 17.22, p-value <0.001) was noted after 30 minutes of Isocal® HN at 80 ml/hr or 210 minutes from baseline. The significant elevations in PrCO2 continued throughout the study. Sixty minutes after discontinuation of enteral feeding, PrCO2 remained significantly elevated from baseline (41.4 ± 6.5 to 51.8 ± 9.2, F = 10.15, p-value 0.004). Conclusion. Enteral feeding with Isocal® HN significantly affects the precision and accuracy of PrCO2 measurements in healthy volunteers. ^
Resumo:
Research has shown that physical activity serves a preventive function against the development of several major chronic diseases. However, studying physical activity and its health benefits is difficult due to the complexity of measuring physical activity. The overall aim of this research is to contribute to the knowledge of both correlates and measurement of physical activity. Data from the Women On The Move study were used for this study (n = 260), and the results are presented in three papers. The first paper focuses on the measurement of physical activity and compares an alternate coding method with the standard coding method for calculating energy expenditure from a 7-day activity diary. Results indicate that the alternative coding scheme could produce similar results to the standard coding in terms of total activity expenditure. Even though agreement could not be achieved by dimension, the study lays the groundwork for a coding system that saves considerable amount of time in coding activity and has the ability to estimate expenditure more accurately for activities that can be performed at varying intensity levels. The second paper investigates intra-day variability in physical activity by estimating the variation in energy expenditure for workers and non-workers and identifying the number of days of diary self-report necessary to reliably estimate activity. The results indicate that 8 days of activity are needed to reliably estimate total activity for individuals who don't work and 12 days of activity are needed to reliably estimate total activity for those who work. Days of diary self-report required by dimension for those who don't work range from 6 to 16 and for those who work from 6 to 113. The final paper presents findings on the relationship between daily living activity and Type A behavior pattern. Significant findings are observed for total activity and leisure activity with the Temperament Scale summary score. Significant findings are also observed for total activity, household chores, work, leisure activity, exercise, and inactivity with one or more of the individual items on the Temperament Scale. However, even though some significant findings were observed, the overall models did not reveal meaningful associations. ^
Resumo:
Arterial spin labeling (ASL) is a technique for noninvasively measuring cerebral perfusion using magnetic resonance imaging. Clinical applications of ASL include functional activation studies, evaluation of the effect of pharmaceuticals on perfusion, and assessment of cerebrovascular disease, stroke, and brain tumor. The use of ASL in the clinic has been limited by poor image quality when large anatomic coverage is required and the time required for data acquisition and processing. This research sought to address these difficulties by optimizing the ASL acquisition and processing schemes. To improve data acquisition, optimal acquisition parameters were determined through simulations, phantom studies and in vivo measurements. The scan time for ASL data acquisition was limited to fifteen minutes to reduce potential subject motion. A processing scheme was implemented that rapidly produced regional cerebral blood flow (rCBF) maps with minimal user input. To provide a measure of the precision of the rCBF values produced by ASL, bootstrap analysis was performed on a representative data set. The bootstrap analysis of single gray and white matter voxels yielded a coefficient of variation of 6.7% and 29% respectively, implying that the calculated rCBF value is far more precise for gray matter than white matter. Additionally, bootstrap analysis was performed to investigate the sensitivity of the rCBF data to the input parameters and provide a quantitative comparison of several existing perfusion models. This study guided the selection of the optimum perfusion quantification model for further experiments. The optimized ASL acquisition and processing schemes were evaluated with two ASL acquisitions on each of five normal subjects. The gray-to-white matter rCBF ratios for nine of the ten acquisitions were within ±10% of 2.6 and none were statistically different from 2.6, the typical ratio produced by a variety of quantitative perfusion techniques. Overall, this work produced an ASL data acquisition and processing technique for quantitative perfusion and functional activation studies, while revealing the limitations of the technique through bootstrap analysis. ^
Resumo:
The purpose of this investigation was to develop a reliable scale to measure the social environment of hospital nursing units according to the degree of humanistic and dehumanistic behaviors as perceived by nursing staff in hospitals. The study was based on a conceptual model proposed by Jan Howard, a sociologist. After reviewing the literature relevant to personalization of care, analyzing interviews with patients in various settings, and studying biological, psychological, and sociological frames of reference, Howard proposed the following necessary conditions for humanized health care. They were the dimensions of Irreplaceability, Holistic Selves, Freedom of Action, Status Equality, Shared Decision Making and Responsibility, Empathy, and Positive Affect.^ It was proposed that a scale composed of behaviors which reflected Howard's dimensions be developed within the framework of the social environment of nursing care units in hospitals. Nursing units were chosen because hospitals are traditionally organized around nursing care units and because patients spend the majority of their time in hospitals interacting with various levels of nursing personnel.^ Approximately 180 behaviors describing both patient and nursing staff behaviors which occur on nursing units were developed. Behaviors which were believed to be humanistic as well as dehumanistic were included. The items were classified under the dimensions of Howard's model by a purposively selected sample of 42 nurses representing a broad range of education, experience, and clinical areas. Those items with a high degree of agreement, at least 50%, were placed in the questionnaire. The questionnaire consisted of 169 items including six items from the Marlowe Crowne Social Desirability Scale (Short Form).^ The questionnaire, the Social Environment Scale, was distributed to the entire 7 to 3 shift nursing staff (603) of four hospitals including a public county specialty hospital, a public county general and acute hospital, a large university affiliated hospital with all services, and a small general community hospital. Staff were asked to report on a Likert type scale how often the listed behaviors occurred on their units. Three hundred and sixteen respondents (52% of the population) participated in the study.^ An item analysis was done in which each item was examined in relationship to its correlation to its own dimension total and to the totals of the other dimensions. As a result of this analysis, three dimensions, Positive Affect, Irreplaceability, and Freedom of Action were deleted from the scale. The final scale consisted of 70 items with 26 in Shared Decision Making and Responsibility, 25 in Holistic Selves, 12 in Status Equality, and seven in Empathy. The alpha coefficient was over .800 for all scales except Empathy which was .597.^ An analysis of variance by hospital was performed on the means of each dimension of the scale. There was a statistically significant difference between hospitals with a trend for the public hospitals to score lower on the scale than the university or community hospitals. That the scale scores should be lower in crowded, understaffed public hospitals was not unexpected and reflected that the scale had some discriminating ability. These differences were still observed after adjusting for the effect of Social Desirability.^ In summary, there is preliminary evidence based on this exploratory investigation that a reliable scale based on at least four dimensions from Howard's model could be developed to measure the concept of humanistic health care in hospital settings. ^