22 resultados para Treatment Effectiveness Evaluation

em DigitalCommons@The Texas Medical Center


Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study assessed if hospital-wide implementation of a needleless intravenous connection system reduces the number of reported percutaneous injuries, overall and those specifically due to intravenous connection activities.^ Incidence rates were compared before and after hospital-wide implementation of a needleless intravenous system at two hospitals, a full service general hospital and a pediatric hospital. The years 1989-1991 were designated as pre-implementation and 1993 was designated as post-implementation. Data from 1992 were not included in the effectiveness evaluation to allow employees to become familiar with use of the new device. The two hospitals showed rate ratios of 1.37 (95% CI = 1.22-1.54, p $\le$.0001) and 1.63 (95% CI = 1.34-1.97, p $\le$.0001), or a 27.1% and a 38.6% reduction in overall injury rate, respectively. Rate ratios for intravenous connection injuries were 2.67 (95% CI = 1.89-3.78, p $\le$.0001) and 3.35 (95% CI = 1.87-6.02, p $\le$.0001), or a 62.5% and a 69.9% reduction in injury rate, respectively. Rate ratios for all non-intravenous connection injuries were calculated to control for factors other than device implementation that may have been operating to reduce the injury rate. These rate ratios were lower, 1.21 and 1.44, demonstrating the magnitude of injury reduction due to factors other than device implementation. It was concluded that the device was effective in reduction of numbers of reported percutaneous injuries.^ Use-effectiveness of the system was also assessed by a survey of randomly selected device users to determine satisfaction with the device, frequency of use and barriers to use. Four hundred seventy-eight surveys were returned for a response rate of 50.9%. Approximately 94% of respondents at both hospitals expressed satisfaction with the needleless system and recommended continued use. The survey also revealed that even though over 50% of respondents report using the device "always" or "most of the time" for intravenous medication administration, flushing lines, and connecting secondary intravenous lines, needles were still being used for these same activities. Compatibility, accessibility and other technical problems were reported as reasons for using needles for these activities. These problems must be addressed, by both manufacturers and users, before the needleless system will be effective in prevention of all intravenous connection injuries. ^

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The Personal Response System Program at Huffington Center on Aging, Baylor College of Medicine, provides emergency call systems for elderly people living independently in Houston, Texas. The goal of the project was to complete a formative evaluation of the Personal Response System Program. The specific aims of the evaluation were three-fold. One aim was to evaluate participant health status and level of disability. The second aim was to develop a health care cost estimation strategy. Finally, a preliminary cost-effectiveness analysis was completed to evaluate the program's impact on health care costs and health status among the elderly target population. ^ The evaluation was a longitudinal, randomized experimental design. After the screening of 120 volunteers for eligibility, clients were asked to complete a written questionnaire and a monthly health service contact diary. Volunteers were contacted by telephone interviewers to collect health status information from 100 eligible clients (83%) on three occasions during the six months of follow-up. ^ Initially, volunteers were randomized to two experimental groups. The two groups were found to be comparable at the beginning of the study. No significant differences were detected related to health status, level of disability, or history of physician visits at baseline. However, the group with the Personal Response System (PRS) device had more adverse health events, higher IADL scores, more frequent use of walkers, lower average health status scores, and fewer community volunteers hours than the usual care comparison group. ^ The health care costs were estimated based on an algorithm adapted from the American Medical Association guidelines. Average total health care costs for the group with the PRS device ($912) were greater than the usual care group ($464). However, median health care values for the PRS group ($263) were similar to the usual care comparison group ($234). The preliminary findings indicated that the use of the PRS device was not associated with health care cost savings. ^ In the preliminary cost-effectiveness analysis, use of the personal response system was found to be associated with increased mental health status among elderly clients. The cost-effectiveness evaluation indicated that the associated cost for six months was $710 per unit increase in mental component score when the $150 PRS subscription was included. However, clients with the PRS device were found to have a greater decline in physical health status during the six-month follow-up. The beneficial effect on mental health status was found to be in contrast to negative findings associated with changes in physical health status. The implications for future research relate to the need to identify risk factors among geriatric populations to better target groups that would most likely benefit from PRS Program enrollment. ^

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Proton therapy is growing increasingly popular due to its superior dose characteristics compared to conventional photon therapy. Protons travel a finite range in the patient body and stop, thereby delivering no dose beyond their range. However, because the range of a proton beam is heavily dependent on the tissue density along its beam path, uncertainties in patient setup position and inherent range calculation can degrade thedose distribution significantly. Despite these challenges that are unique to proton therapy, current management of the uncertainties during treatment planning of proton therapy has been similar to that of conventional photon therapy. The goal of this dissertation research was to develop a treatment planning method and a planevaluation method that address proton-specific issues regarding setup and range uncertainties. Treatment plan designing method adapted to proton therapy: Currently, for proton therapy using a scanning beam delivery system, setup uncertainties are largely accounted for by geometrically expanding a clinical target volume (CTV) to a planning target volume (PTV). However, a PTV alone cannot adequately account for range uncertainties coupled to misaligned patient anatomy in the beam path since it does not account for the change in tissue density. In order to remedy this problem, we proposed a beam-specific PTV (bsPTV) that accounts for the change in tissue density along the beam path due to the uncertainties. Our proposed method was successfully implemented, and its superiority over the conventional PTV was shown through a controlled experiment.. Furthermore, we have shown that the bsPTV concept can be incorporated into beam angle optimization for better target coverage and normal tissue sparing for a selected lung cancer patient. Treatment plan evaluation method adapted to proton therapy: The dose-volume histogram of the clinical target volume (CTV) or any other volumes of interest at the time of planning does not represent the most probable dosimetric outcome of a given plan as it does not include the uncertainties mentioned earlier. Currently, the PTV is used as a surrogate of the CTV’s worst case scenario for target dose estimation. However, because proton dose distributions are subject to change under these uncertainties, the validity of the PTV analysis method is questionable. In order to remedy this problem, we proposed the use of statistical parameters to quantify uncertainties on both the dose-volume histogram and dose distribution directly. The robust plan analysis tool was successfully implemented to compute both the expectation value and its standard deviation of dosimetric parameters of a treatment plan under the uncertainties. For 15 lung cancer patients, the proposed method was used to quantify the dosimetric difference between the nominal situation and its expected value under the uncertainties.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The effectiveness of the Anisotropic Analytical Algorithm (AAA) implemented in the Eclipse treatment planning system (TPS) was evaluated using theRadiologicalPhysicsCenteranthropomorphic lung phantom using both flattened and flattening-filter-free high energy beams. Radiation treatment plans were developed following the Radiation Therapy Oncology Group and theRadiologicalPhysicsCenterguidelines for lung treatment using Stereotactic Radiation Body Therapy. The tumor was covered such that at least 95% of Planning Target Volume (PTV) received 100% of the prescribed dose while ensuring that normal tissue constraints were followed as well. Calculated doses were exported from the Eclipse TPS and compared with the experimental data as measured using thermoluminescence detectors (TLD) and radiochromic films that were placed inside the phantom. The results demonstrate that the AAA superposition-convolution algorithm is able to calculate SBRT treatment plans with all clinically used photon beams in the range from 6 MV to 18 MV. The measured dose distribution showed a good agreement with the calculated distribution using clinically acceptable criteria of ±5% dose or 3mm distance to agreement. These results show that in a heterogeneous environment a 3D pencil beam superposition-convolution algorithms with Monte Carlo pre-calculated scatter kernels, such as AAA, are able to reliably calculate dose, accounting for increased lateral scattering due to the loss of electronic equilibrium in low density medium. The data for high energy plans (15 MV and 18 MV) showed very good tumor coverage in contrast to findings by other investigators for less sophisticated dose calculation algorithms, which demonstrated less than expected tumor doses and generally worse tumor coverage for high energy plans compared to 6MV plans. This demonstrates that the modern superposition-convolution AAA algorithm is a significant improvement over previous algorithms and is able to calculate doses accurately for SBRT treatment plans in the highly heterogeneous environment of the thorax for both lower (≤12 MV) and higher (greater than 12 MV) beam energies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

With an increasing number of institutions offering proton therapy, the number of multi-institutional clinical trials involving proton therapy will also increase in the coming years. The Radiological Physics Center monitors sites involved in clinical trials through the use of site visits and remote auditing with thermoluminescent dosimeters (TLD) and mailable anthropomorphic phantoms. Currently, there are no heterogeneous phantoms that have been commissioned to evaluate proton therapy. It was hypothesized that an anthropomorphic pelvis phantom can be designed to audit treatment procedures (patient simulation, treatment planning and treatment delivery) at proton facilities to confirm agreement between the measured dose and calculated dose within 5%/3mm with a reproducibility of 3%. A pelvis phantom originally designed for use with photon treatments was retrofitted for use in proton therapy. The relative stopping power (SP) of each phantom material was measured. Hounsfield Units (HU) for each phantom material were measured with a CT scanner and compared to the relative stopping power calibration curve. The tissue equivalency for each material was calculated. Two proton treatment plans were created; one which did not correct for material SP differences (Plan 1) and one plan which did correct for SP differences (Plan 2). Film and TLD were loaded into the phantom and the phantom was irradiated 3 times per plan. The measured values were compared to the HU-SP calibration curve and it was found that the stopping powers for the materials could be underestimated by 5-10%. Plan 1 passed the criteria for the TLD and film margins with reproducibility under 3% between the 3 trials. Plan 2 failed because the right-left film dose profile average displacement was -9.0 mm on the left side and 6.0 mm on the right side. Plan 2 was intended to improve the agreements and instead introduced large displacements along the path of the beam. Plan 2 more closely represented the actual phantom composition with corrected stopping powers and should have shown an agreement between the measured and calculated dose within 5%/3mm. The hypothesis was rejected and the pelvis phantom was found to be not suitable to evaluate proton therapy treatment procedures.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: To estimate the costs and outcomes of rescreening for group B streptococci (GBS) compared to universal treatment of term women with history of GBS colonization in a previous pregnancy. STUDY DESIGN: A decision analysis model was used to compare costs and outcomes. Total cost included the costs of screening, intrapartum antibiotic prophylaxis (IAP), treatment for maternal anaphylaxis and death, evaluation of well infants whose mothers received IAP, and total costs for treatment of term neonatal early onset GBS sepsis. RESULTS: When compared to screening and treating, universal treatment results in more women treated per GBS case prevented (155 versus 67) and prevents more cases of early onset GBS (1732 versus 1700) and neonatal deaths (52 versus 51) at a lower cost per case prevented ($8,805 versus $12,710). CONCLUSION: Universal treatment of term pregnancies with a history of previous GBS colonization is more cost-effective than the strategy of screening and treating based on positive culture results.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Whole-body hypothermia reduced the frequency of death or moderate/severe disabilities in neonates with hypoxic-ischemic encephalopathy in a randomized, controlled multicenter trial. OBJECTIVE: Our goal was to evaluate outcomes of safety and effectiveness of hypothermia in infants up to 18 to 22 months of age. DESIGN/METHODS: A priori outcomes were evaluated between hypothermia (n = 102) and control (n = 106) groups. RESULTS: Encephalopathy attributable to causes other than hypoxia-ischemia at birth was not noted. Inotropic support (hypothermia, 59% of infants; control, 56% of infants) was similar during the 72-hour study intervention period in both groups. Need for blood transfusions (hypothermia, 24%; control, 24%), platelet transfusions (hypothermia, 20%; control, 12%), and volume expanders (hypothermia, 54%; control, 49%) was similar in the 2 groups. Among infants with persistent pulmonary hypertension (hypothermia, 25%; control, 22%), nitric-oxide use (hypothermia, 68%; control, 57%) and placement on extracorporeal membrane oxygenation (hypothermia, 4%; control, 9%) was similar between the 2 groups. Non-central nervous system organ dysfunctions occurred with similar frequency in the hypothermia (74%) and control (73%) groups. Rehospitalization occurred among 27% of the infants in the hypothermia group and 42% of infants in the control group. At 18 months, the hypothermia group had 24 deaths, 19 severe disabilities, and 2 moderate disabilities, whereas the control group had 38 deaths, 25 severe disabilities, and 1 moderate disability. Growth parameters were similar between survivors. No adverse outcomes were noted among infants receiving hypothermia with transient reduction of temperature below a target of 33.5 degrees C at initiation of cooling. There was a trend in reduction of frequency of all outcomes in the hypothermia group compared with the control group in both moderate and severe encephalopathy categories. CONCLUSIONS: Although not powered to test these secondary outcomes, whole-body hypothermia in infants with encephalopathy was safe and was associated with a consistent trend for decreasing frequency of each of the components of disability.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Intensity modulated radiation therapy (IMRT) is a technique that delivers a highly conformal dose distribution to a target volume while attempting to maximally spare the surrounding normal tissues. IMRT is a common treatment modality used for treating head and neck (H&N) cancers, and the presence of many critical structures in this region requires accurate treatment delivery. The Radiological Physics Center (RPC) acts as both a remote and on-site quality assurance agency that credentials institutions participating in clinical trials. To date, about 30% of all IMRT participants have failed the RPC’s remote audit using the IMRT H&N phantom. The purpose of this project is to evaluate possible causes of H&N IMRT delivery errors observed by the RPC, specifically IMRT treatment plan complexity and the use of improper dosimetry data from machines that were thought to be matched but in reality were not. Eight H&N IMRT plans with a range of complexity defined by total MU (1460-3466), number of segments (54-225), and modulation complexity scores (MCS) (0.181-0.609) were created in Pinnacle v.8m. These plans were delivered to the RPC’s H&N phantom on a single Varian Clinac. One of the IMRT plans (1851 MU, 88 segments, and MCS=0.469) was equivalent to the median H&N plan from 130 previous RPC H&N phantom irradiations. This average IMRT plan was also delivered on four matched Varian Clinac machines and the dose distribution calculated using a different 6MV beam model. Radiochromic film and TLD within the phantom were used to analyze the dose profiles and absolute doses, respectively. The measured and calculated were compared to evaluate the dosimetric accuracy. All deliveries met the RPC acceptance criteria of ±7% absolute dose difference and 4 mm distance-to-agreement (DTA). Additionally, gamma index analysis was performed for all deliveries using a ±7%/4mm and ±5%/3mm criteria. Increasing the treatment plan complexity by varying the MU, number of segments, or varying the MCS resulted in no clear trend toward an increase in dosimetric error determined by the absolute dose difference, DTA, or gamma index. Varying the delivery machines as well as the beam model (use of a Clinac 6EX 6MV beam model vs. Clinac 21EX 6MV model), also did not show any clear trend towards an increased dosimetric error using the same criteria indicated above.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Early Employee Assistance Programs (EAPs) had their origin in humanitarian motives, and there was little concern for their cost/benefit ratios; however, as some programs began accumulating data and analyzing it over time, even with single variables such as absenteeism, it became apparent that the humanitarian reasons for a program could be reinforced by cost savings particularly when the existence of the program was subject to justification.^ Today there is general agreement that cost/benefit analyses of EAPs are desirable, but the specific models for such analyses, particularly those making use of sophisticated but simple computer based data management systems, are few.^ The purpose of this research and development project was to develop a method, a design, and a prototype for gathering managing and presenting information about EAPS. This scheme provides information retrieval and analyses relevant to such aspects of EAP operations as: (1) EAP personnel activities, (2) Supervisory training effectiveness, (3) Client population demographics, (4) Assessment and Referral Effectiveness, (5) Treatment network efficacy, (6) Economic worth of the EAP.^ This scheme has been implemented and made operational at The University of Texas Employee Assistance Programs for more than three years.^ Application of the scheme in the various programs has defined certain variables which remained necessary in all programs. Depending on the degree of aggressiveness for data acquisition maintained by program personnel, other program specific variables are also defined. ^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Prostatic carcinoma is the most prevalent cancer detected in men. Bortezomib is the first proteasome inhibitor to undergo clinical trials for several forms of cancer. Although we know this class of agent preferentially kills cancer cells, our knowledge of proteasome inhibition mechanisms of induced death is far from complete. We investigated the effects of bortezomib on the LNCaP-Pro5 (Pro5) and PC-3-Pro4 (Pro4) human prostatic adenocarcinoma cells lines. We showed a reduction in proliferation and an increase in DNA fragmentation, caspase 3 activity, and cell surface phosphatidyl serine exposure. The bortezomib-treated tumors from both cell lines were dramatically reduced, and apoptosis was induced. There was also a reduction in proliferation in the treated tumors from both cells lines. We looked at changes in the levels of the proangiogenic factors VEGF, IL-8 and bFGF in vitro and in vivo. Although there was a reduction in the levels of VEGF produced by the Pro5 cell line and tumor due to bortezomib, no similar observations were made for the other angiogenic factors or in the Pro4 cells. We investigated the effects of bortezomib on p53 in the Pro5 cell line. Bortezomib induced strong stabilization of p53. It did not promote phosphorylation on serines 15 and 24 and p53 remained bound to its inhibitor, mdm2. Nonetheless, confocal microscopy revealed that bortezomib stimulated p53 translocation to the nucleus and enhanced p53 DNA binding, accumulation of p53-dependant transcripts, and activation of a p53-responsive reporter gene. Furthermore, stable transfectants of LNCaP-Pro5 expressing the p53 inhibitor, HPV-E6, displayed reduced bortezomib-induced p53 activation and cell death. Our data shows bortezomib to induce antitumor effects in the human Pro4 and Pro5 prostatic adenocarcinoma cell lines by the direct induction of apoptosis. The drug also causes a reduction in cell proliferation and mean vessel density while modulating the secretion of proangiogenic factors. Although we show that proteasome inhibition stimulates p53 activation via a novel mechanism in Pro5 cells, it is also toxic to p53 null cells as is seen in the Pro4 line. ^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background. Diabetes places a significant burden on the health care system. Reduction in blood glucose levels (HbA1c) reduces the risk of complications; however, little is known about the impact of disease management programs on medical costs for patients with diabetes. In 2001, economic costs associated with diabetes totaled $100 billion, and indirect costs totaled $54 billion. ^ Objective. To compare outcomes of nurse case management by treatment algorithms with conventional primary care for glycemic control and cardiovascular risk factors in type 2 diabetic patients in a low-income Mexican American community-based setting, and to compare the cost effectiveness of the two programs. Patient compliance was also assessed. ^ Research design and methods. An observational group-comparison to evaluate a treatment intervention for type 2 diabetes management was implemented at three out-patient health facilities in San Antonio, Texas. All eligible type 2 diabetic patients attending the clinics during 1994–1996 became part of the study. Data were obtained from the study database, medical records, hospital accounting, and pharmacy cost lists, and entered into a computerized database. Three groups were compared: a Community Clinic Nurse Case Manager (CC-TA) following treatment algorithms, a University Clinic Nurse Case Manager (UC-TA) following treatment algorithms, and Primary Care Physicians (PCP) following conventional care practices at a Family Practice Clinic. The algorithms provided a disease management model specifically for hyperglycemia, dyslipidemia, hypertension, and microalbuminuria that progressively moved the patient toward ideal goals through adjustments in medication, self-monitoring of blood glucose, meal planning, and reinforcement of diet and exercise. Cost effectiveness of hemoglobin AI, final endpoints was compared. ^ Results. There were 358 patients analyzed: 106 patients in CC-TA, 170 patients in UC-TA, and 82 patients in PCP groups. Change in hemoglobin A1c (HbA1c) was the primary outcome measured. HbA1c results were presented at baseline, 6 and 12 months for CC-TA (10.4%, 7.1%, 7.3%), UC-TA (10.5%, 7.1%, 7.2%), and PCP (10.0%, 8.5%, 8.7%). Mean patient compliance was 81%. Levels of cost effectiveness were significantly different between clinics. ^ Conclusion. Nurse case management with treatment algorithms significantly improved glycemic control in patients with type 2 diabetes, and was more cost effective. ^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background. Diets high in fat and calories are promoted by the toxic food environment in which high fat, high calorie foods are readily accessible, thus contributing to high rates of overweight and obesity.^ Hypothesis. Changing the food environment to make low-fat, low-calorie foods readily identifiable and accessible while simultaneously offering incentives for choosing those foods will result in increased consumption of targeted foods, thus decreasing caloric and fat intake and ultimately decreasing obesity rates.^ Objective. To conduct an outcome evaluation study on the effectiveness of The Fresh & Healthy Program, a health promotion project designed to promote healthy eating among The Methodist Hospital employees by labeling and promoting low calorie, low fat items in the hospital cafeteria. ^ Program. By promoting healthy eating, this program seeks to address unhealthy dietary behaviors, one of the most widely known and influential behavioral causes of obesity. Food items that are included in the program meet nutritional criteria for calories and fat and are labeled with a special logo. Program participants receive incentives for purchasing Fresh & Healthy items. The program was designed and implemented by a team of registered dietitians, two health education specialists, and retail foodservice managers at The Methodist Hospital in the Texas Medical Center in Houston and has been in existence since April 2006.^ Methods. The evaluation uses a non-randomized, one-group, time series design to evaluate the effect of the program on sales of targeted food items.^ Key words. point-of-purchase, menu labeling, environmental obesity interventions, food pricing interventions ^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This retrospective, case-control study investigated the effectiveness of the Houston, Texas Ask Your Nurse Advice Line (AYN) in diverting callers with non-emergent medical conditions away from the emergency department (ED). After asking callers a series of questions, AYN nurses evaluate the medical condition and make recommendations for appropriate care, e.g., home care, see a clinic physician, or visit the ED. To evaluate the AYN, the rate of caller ED visits before accessing the AYN for the first time was compared to the caller ED visit rate afterwards. The pre-post rate change was compared to that of a control group of similar caller age, race, gender, and insurance status drawn from a Harris County Hospital District HCHD database. ^ The treatment group (AYN caller) had a 66% reduction in ED visits after the first AYN call compared to an 18% drop in ED visits among control group subjects during the same time period. Study results were presented to HCHD staff on August 30th, 2007 and recommendations were made for future studies that would provide a basis for policy development. ^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Cardiovascular disease has been the leading cause of death in the United States for over fifty years. While multiple risk factors for cardiovascular disease have been identified, hypertension is one of the most commonly recognized and treatable. Recent studies indicate that the prevalence of hypertension among children and adolescents is between 3-5%, much higher than originally estimated and likely rising due to the epidemic of obesity in the U.S. In 2004, the National High Blood Pressure Education Program Working Group on High Blood Pressure in Children and Adolescents published new guidelines for the diagnosis and treatment of hypertension in this population. Included in these recommendations was the creation of a new diagnosis, pre-hypertension, aimed at identifying children at-risk for hypertension to provide early lifestyle interventions in an effort to prevent its ultimate development. In order to determine the risk associated with pre-hypertension for the development of incident HTN, a secondary analysis of a repeated cross-sectional study measuring blood pressure in Houston area adolescents from 2000 to 2007 was performed. Of 1006 students participating in the blood pressure screening on more than one occasion not diagnosed with hypertension at initial encounter, eleven were later found to have hypertension providing an overall incident rate of 0.5% per year. Incidence rates were higher among overweight adolescents–1.9% per year [IRR 8.6 (1.97, 51.63)]; students “at-risk for hypertension” (pre-hypertensive or initial blood pressure in the hypertensive range but falling on subsequent measures)–1.4% per year [IRR 4.77 (1.21, 19.78)]; and those with blood pressure ≥90th percentile on three occasions–6.6% per year [IRR 21.87 (3.40, 112.40)]. Students with pre-hypertension as currently defined by the Task Force did have an increased rate of hypertension (1.1% per year) but it did not reach statistical significance [IRR 2.44 (0.42, 10.18)]. Further research is needed to determine the morbidity and mortality associated with pre-hypertension in this age group as well as the effectiveness of various interventions for preventing the development of hypertensive disease among these at-risk individuals. ^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Diabetes Mellitus is not a disease, but a group of diseases. Common to all types of diabetes is high levels of blood glucose produced from a variety of causes. In 2006, the American Diabetes Association ranked diabetes as the fifth leading cause of death in the United States. The complications and consequences are serious and include nephropathy, retinopathy, neuropathy, heart disease, amputations, pregnancy complications, sexual dysfunction, biochemical imbalances, susceptibility and sensitivity to many other diseases and in some cases death. ^ The serious nature of diabetes mellitus and its complications has compelled researchers to devise new strategies to reach population segments at high risk. Various avenues of outreach have been attempted. This pilot program is not unique in using a health museum as a point of outreach. However health museums have not been a major source of interventions, either. Little information was available regarding health museum visitor demographics, visitation patterns, companion status and museum trust levels prior to this pilot intervention. This visitor information will improve planning for further interventions and studies. ^ This thesis also examined prevalence data in a temporal context, the populations at risk for diabetes, the collecting agencies, and other relevant collected data. The prevalence of diabetes has been rapidly increasing. The increase is partially explained by refinement of the definition of diabetes as the etiology has become better understood. Increasing obesity and sedentary lifestyles have contributed to the increase, as well as the burdensome increase on minority populations. ^ Treatment options are complex and have had limited effectiveness. This would lead one to conclude that prevention and early diagnosis are preferable. However, the general public has insufficient awareness and education regarding diabetes symptoms and the serious risks and complications the disease can cause. Reaching high risk, high prevalence, populations is challenging for any intervention. During its “free family Thursdays” The Health Museum (Houston, Texas) has attracted a variety of ethnic patrons; similar to the Houston and Harris County demographics. This research project explored the effectiveness of a pilot diabetes educational intervention in a health museum setting where people chose to visit. ^