7 resultados para Measurement tool
em DigitalCommons@The Texas Medical Center
Resumo:
Background. With the rapid rise in childhood obesity, physical activity participation among young children has become the subject of much recent attention. Physical education classes have been specifically targeted as a method of providing opportunities for all children to be active. Unfortunately, student participation in moderate-to-vigorous physical activity during these classes still falls far below the current recommendations. While some research to date has reported the levels of activity among elementary-aged children, research is limited on the relationship between these activity levels and the environmental characteristics that exist within the PE classroom. ^ Purpose. The purpose of this study is to examine the association between specific classroom characteristics and contextual characteristics (lesson context, class size, class location, teacher gender, and teacher encouragement for PA) with elementary aged children's moderate-to-vigorous activity during PE class. ^ Methods. A secondary analysis of 211 3rd, 4th and 5th grade physical education classes amongst 39 elementary schools in Harris County, TX and 35 elementary schools in Travis County, TX was conducted using cross-sectional data from the evaluation of a school-based health program. Lesson context and student activity levels were measured using a direct observation measurement tool. Additionally, these variables were further analyzed against a number of classroom characteristics to determine any significant associations. ^ Results. Overall, elementary PE classes are still participating in low levels of moderate-to-vigorous physical activity averaging only 38% of class time. Additionally, close to 25% of class time is spent in classroom management. Male directed classes spent significantly more time in game activities and female directed classes spent more time in fitness, knowledge, and skill activities. Classes that took place outdoors were more active and spent more time in games than those that took place indoors. Significant correlations were demonstrated between class size and time spent in management context. Time spent in management context was also correlated with time spent sitting and standing. Additionally, positive correlations were demonstrated between time very active and teachers that praised students and encouraged physical activity among their classes.^
Resumo:
BACKGROUND: Few reports of the utilization of an accurate, cost-effective means for measuring HPV oncogene transcripts have been published. Several papers have reported the use of relative quantitation or more expensive Taqman methods. Here, we report a method of absolute quantitative real-time PCR utilizing SYBR-green fluorescence for the measurement of HPV E7 expression in cervical cytobrush specimens. RESULTS: The construction of a standard curve based on the serial dilution of an E7-containing plasmid was the key for being able to accurately compare measurements between cervical samples. The assay was highly reproducible with an overall coefficient of variation of 10.4%. CONCLUSION: The use of highly reproducible and accurate SYBR-based real-time polymerase chain reaction (PCR) assays instead of performing Taqman-type assays allows low-cost, high-throughput analysis of viral mRNA expression. The development of such assays will help in refining the current screening programs for HPV-related carcinomas.
Resumo:
Introduction Commercial treatment planning systems employ a variety of dose calculation algorithms to plan and predict the dose distributions a patient receives during external beam radiation therapy. Traditionally, the Radiological Physics Center has relied on measurements to assure that institutions participating in the National Cancer Institute sponsored clinical trials administer radiation in doses that are clinically comparable to those of other participating institutions. To complement the effort of the RPC, an independent dose calculation tool needs to be developed that will enable a generic method to determine patient dose distributions in three dimensions and to perform retrospective analysis of radiation delivered to patients who enrolled in past clinical trials. Methods A multi-source model representing output for Varian 6 MV and 10 MV photon beams was developed and evaluated. The Monte Carlo algorithm, know as the Dose Planning Method (DPM), was used to perform the dose calculations. The dose calculations were compared to measurements made in a water phantom and in anthropomorphic phantoms. Intensity modulated radiation therapy and stereotactic body radiation therapy techniques were used with the anthropomorphic phantoms. Finally, past patient treatment plans were selected and recalculated using DPM and contrasted against a commercial dose calculation algorithm. Results The multi-source model was validated for the Varian 6 MV and 10 MV photon beams. The benchmark evaluations demonstrated the ability of the model to accurately calculate dose for the Varian 6 MV and the Varian 10 MV source models. The patient calculations proved that the model was reproducible in determining dose under similar conditions described by the benchmark tests. Conclusions The dose calculation tool that relied on a multi-source model approach and used the DPM code to calculate dose was developed, validated, and benchmarked for the Varian 6 MV and 10 MV photon beams. Several patient dose distributions were contrasted against a commercial algorithm to provide a proof of principal to use as an application in monitoring clinical trial activity.
Resumo:
Bipolar mixed states combine depressive and manic features, presenting diagnostic and treatment challenges and reflecting a severe form of the illness. DSM-IV criteria for a mixed state require combined depressive and manic syndromes, but a range of mixed states has been described clinically. A unified definition of mixed states would be valuable in understanding their diagnosis, mechanism and treatment implications. We investigated the manner in which depressive and manic features combine to produce a continuum of mixed states. In 88 subjects with bipolar disorder (DSM-IV), we evaluated symptoms and clinical characteristics, and compared depression-based, mania-based, and other published definitions of mixed states. We developed an index of the extent to which symptoms were mixed (Mixed State Index, MSI) and characterized its relationship to clinical state. Predominately manic and depressive mixed states using criteria from recent literature, as well as Kraepelinian mixed states, had similar symptoms and MSI scores. Anxiety correlated significantly with depression scores in manic subjects and with mania scores in depressed subjects. Discriminant function analysis associated mixed states with symptoms of hyperactivity and negative cognitions, but not subjective depressive or elevated mood. High MSI scores were associated with severe course of illness. For depressive or manic episodes, characteristics of mixed states emerged with two symptoms of the opposite polarity. This was a cross-sectional study. Mixed states appear to be a continuum. An index of the degree to which depressive and manic symptoms combine appears useful in identifying and characterizing mixed states. We propose a depressive or manic episode with three or more symptoms of the opposite polarity as a parsimonious definition of a mixed state.
Resumo:
Experience with anidulafungin against Candida krusei is limited. Immunosuppressed mice were injected with 1.3 x 10(7) to 1.5 x 10(7) CFU of C. krusei. Animals were treated with saline, 40 mg/kg fluconazole, 1 mg/kg amphotericin B, or 10 and 20 mg/kg anidulafungin for 5 days. Anidulafungin improved survival and significantly reduced the number of CFU/g in kidneys and serum beta-glucan levels.
Resumo:
This work aimed to create a mailable and OSLD-based phantom with accuracy suitable for RPC audits of HDR brachytherapy sources at institutions participating in NCI-funded cooperative clinical trials. An 8 × 8 × 10 cm3 prototype with two slots capable of holding nanoDot Al2O3:C OSL dosimeters (Landauer, Glenwood, IL) was designed and built. The phantom has a single channel capable of accepting all 192Ir HDR brachytherapy sources in current clinical use in the United States. Irradiations were performed with an 192Ir HDR source to determine correction factors for linearity with dose, dose rate, and the combined effect of irradiation energy and phantom construction. The uncertainties introduced by source positioning in the phantom and timer resolution limitations were also investigated. It was found that the linearity correction factor was where dose is in cGy, which differed from that determined by the RPC for the same batch of dosimeters under 60Co irradiation. There was no significant dose rate effect. Separate energy+block correction factors were determined for both models of 192Ir sources currently in clinical use and these vendor-specific correction factors differed by almost 2.6%. For Nucletron sources, this correction factor was 1.026±0.004 (99% Confidence Interval) and for Varian sources it was 1.000±0.007 (99% CI). Reasonable deviations in source positioning within the phantom and the limited resolution of the source timer had insignificant effects on the ability to measure dose. Overall measurement uncertainty of the system was estimated to be ±2.5% for both Nucletron and Varian source audits (95% CI). This uncertainty was sufficient to establish a ±5% acceptance criterion for source strength audits under a formal RPC audit program. Trial audits of eight participating institutions resulted in an average RPC-to-institution dose ratio of 1.000 with a standard deviation of 0.011.
Resumo:
Mistreatment and self-neglect significantly increase the risk of dying in older adults. It is estimated that 1 to 2 million older adults experience elder mistreatment and self-neglect every year in the United States. Currently, there are no elder mistreatment and self-neglect assessment tools with construct validity and measurement invariance testing and no studies have sought to identify underlying latent classes of elder self-neglect that may have differential mortality rates. Using data from 11,280 adults with Texas APS substantiated elder mistreatment and self-neglect 3 studies were conducted to: (1) test the construct validity and (2) the measurement invariance across gender and ethnicity of the Texas Adult Protective Services (APS) Client Assessment and Risk Evaluation (CARE) tool and (3) identify latent classes associated with elder self-neglect. Study 1 confirmed the construct validity of the CARE tool following adjustments to the initial hypothesized CARE tool. This resulted in the deletion of 14 assessment items and a final assessment with 5 original factors and 43 items. Cross-validation for this model was achieved. Study 2 provided empirical evidence for factor loading and item-threshold invariance of the CARE tool across gender and between African-Americans and Caucasians. The financial status domain of the CARE tool did not function properly for Hispanics and thus, had to be deleted. Subsequent analyses showed factor loading and item-threshold invariance across all 3 ethnic groups with the exception of some residual errors. Study 3 identified 4-latent classes associated with elder self-neglect behaviors which included individuals with evidence of problems in the areas of (1) their environment, (2) physical and medical status, (3) multiple domains and (4) finances. Overall, these studies provide evidence supporting the use of APS CARE tool for providing unbiased and valid investigations of mistreatment and neglect in older adults with different demographic characteristics. Furthermore, the findings support the underlying notion that elder self-neglect may not only occur along a continuum, but that differential types may exist. All of which, have very important potential implications for social and health services distributed to vulnerable mistreated and neglected older adults.^